• 제목/요약/키워드: CM-wire

검색결과 252건 처리시간 0.027초

발신자정보표시(CID)용 무선 송수신 모듈 구현 (The Implementation of Radio Transceiver Modules For CID)

  • 황인태;장태원;강민구;이효종
    • 한국정보통신학회논문지
    • /
    • 제7권1호
    • /
    • pp.50-58
    • /
    • 2003
  • 발신자 정보표시 서비스가 전화번호를 표시하는 차원을 넘어 무선인터넷처럼 단문 메시지 서비스와 e-메일 등을 이용할 수 있는 데이터 송수신으로 자리잡게 될 것이다. 따라서 본 논문은 이러한 신규 서비스에 이용될 발신자 정보표시 기능의 데이터 처리과정상의 에러 발생요소를 분석하고, 기존의 CID시스템의 성능개선 방법을 채택한 무선 송수신 모듈을 구현하는 방법을 제안하고자 한다.

The Treatment of Gunshot Wound with Maxillofacial Fracture in a Dog

  • Kim, Young-ung;Lee, Dong-bin;Heo, Su-young;Kim, Nam-soo
    • 한국임상수의학회지
    • /
    • 제35권5호
    • /
    • pp.215-217
    • /
    • 2018
  • A one-year-old, intact male, 24 kg, mixed breed dog was referred to the Animal Medical Center, Iksan, Chonbuk, Korea for treatment of a gunshot wound to the head. Physical examinations revealed bilateral nasal bleeding and open-mouth breathing. Radiographic examination showed fracture of the right maxilla bone and multiple fractures of the nasal bone. A $1cm{\times}1cm{\times}1.8cm$ region of mineral opacity material was observed in the right-cranial ventralnasal cavity and a $6mm{\times}6mm{\times}9mm$ region of mineral opacity material was present in the left-cranial dorsal-nasal cavity. The surgical procedure involved removal of bone fragments and the lodged bullet as well as the installation of three intraosseous wires. At two weeks after surgery, the patient exhibited no complications and had a good prognosis.

실리카흄 혼입한 SFRS의 리반운드율에 관한 실험적 연구 (An Experimental Study on the Rebound Ratios of SFRS with Silica Fume)

  • 손영현;변형균;조용복
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.429-434
    • /
    • 1994
  • In this study, an experiment in the field was performed to analyze the variations of rebound ratios of SFRS with silica fume after fabricating the panels and placing the plain concrete of simulting a base rock with thickness 7cm. And the experimental parameters which are the reinforcing methods(steel fiber, wire mesh), steel fiber contents(0.0%, 0.5%, 0.75%, 1.0%), silica fume contents(0.0%, 10.0%), and the three parts(lower, middle, upper part) were chosen. According to the results of the lower part in this test, the larger the fiber contents are in case of steel fiber reinforced shotcrete, the less the rebound ratios are within the range of 20~35%, compared to the wire-mesh reinforced shotcrete with silica fume content of 10%, and these results are true of the middle and upper part, respectively. In addition, the four-stage phenomena of the rebound of SFRS were estimated on the base of a series of the test results.

  • PDF

수송전류에 따른 Bi-2223 선재의 특성연구 (The characteristic research of a Bi-2223 wires by the Various Transport Current)

  • 오정훈;배덕권;강형구;안민철;이상진;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.220-223
    • /
    • 2003
  • High-Tc superconducting(HT S) systems are commercialized by many study on high-Tc superconductor. For the successful commercialization of superconducting systems using Bi-2223 wires, the database on the degradation of critical current is essentially needed. In this paper, critical current variation of Bi-2223 wires according to the transport time was investigated. The degradation rate of critical current was also calculated. Solenoid type specimens have the length of 190cm Bi-2223 wire and double-pancake type specimens have the length of l0m wire were tested. Tested Bi-2223 wires are commercialized products of AMSC (American Superconductor) and Innost. When the transportation current was 95% of critical current, the degradation of critical current was appeared after 5 hours of transport time.

  • PDF

코어 변화에 대한 자계 특성 (Magnetic Field Properties About Core Change)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제25권2호
    • /
    • pp.159-164
    • /
    • 2012
  • In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.

Non-cracking YBCO Films on Silver Wire

  • Soh, Dea-Wha;Korobova, N.;Li, Young-Mae
    • 동굴
    • /
    • 제76호
    • /
    • pp.1-13
    • /
    • 2006
  • Electrophoretic deposition (EPD) of alcohol YBCO suspensions on the Ag wire electrode is studied. Poly(ethylene glycol) was coordinated to a structure formed by the EPD process with YBCO particles. The suspension is characterized in terms of zeta potential and conductivity. The d.c electric fields of 200-300 V/cm are applied for 1-10 min. The optimal condition for the EPD allows modifying the properties and microstructure of the deposited films. Superconducting coatings with nanometer-sized pores and a preferred orientation along the c-axis were prepared from the result with chemically modified precursor solution. In contrast, YBCO coatings of submicrometer-sized pores and randomly orientated grains were prepared from the solution without PEG.

High Temperature Superconducting (HTS) Films by EPD Method addition with $BaF_2$ and PEG

  • Soh, Deawha;Korobova, N.;Park, Jung-Cheul;Jeun, Yong-Woo
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.250-254
    • /
    • 2000
  • High temperature superconducting films deposited on metal Ag wire were prepared with YBCO powders by electrophoretic deposition method. $I_2$was used as additives for surface charge of YBCO particles. When 2~3 wt.% $BaF_2$ was added in the YBCO suspension, the pores and cracks of film surface were decreased and film density could be increased. In case of YBCO films, the critical current density ($J_{c}$) was calculated at the value of $1458{\;}A/\textrm{cm}^2$ (77K, 0K) by 4 point prove method.

  • PDF

코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공 (Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment)

  • 홍영기
    • 한국염색가공학회지
    • /
    • 제25권3호
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

브래지어 총(總) 길이 적합성(適合性)에 관(關)한 연구(硏究)(II) (A Study on the adaptedness of brassiere underbust length)

  • 박유신;최영순
    • 패션비즈니스
    • /
    • 제10권1호
    • /
    • pp.31-40
    • /
    • 2006
  • We studied relation between the clothing pressure applied by types of brassiere, postures, feeling of tightness. The main results were summerized as follows; 1. The research subjects of this study were 9 who rate of body fat was borderline and degree of fatness was normal. As a result of clothing pressure, the most prefered value was $36.86g/cm^2$ on sensor 2 in standing position and the next was $34.76g/cm^2$ on sitting position. Furthermore, The maximum value of sensor 2 was $59.08g/cm^2$ (in standing), $57.93g/cm^2$ (in sitting). On the other hand, The average clothing pressure of bra C type was $23.67g/cm^2$ 2. The study of feeling of tightness applied by bra type was high in order of C

$C_4H_6O_5$ 도핑된 $MgB_2/Fe$ 선재의 임계특성에 대한 열처리 온도의 영향 (Influence of the Heat-treatment Temperature on the Critical Properties of $C_4H_6O_5$-doped $MgB_2/Fe$ Wire)

  • 전병혁;김정호;;김찬중
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.62-67
    • /
    • 2007
  • The effects of the heat-treatment temperature on the carbon (C) substitution amount, full width at half maximum (FWHM) value, critical temperature ($T_c$), critical current density ($J_c$) have been investigated for 10 wt % malic acid ($C_4H_6O_5$)-doped $MgB_2/Fe$ wires. All the samples were fabricated by the in-situ powder-in-tube (PIT) method and heat-treated within a temperature range of $650^{\circ}C$ to $1000^{\circ}C$. As the heat-treatment temperature increased, it seemed that the lattice distortion was increased by a more active C substitution into the boron sites from the malic acid addition. These increased electron scattering defects seemed to enhance the $J_c-H$ properties in spite of an improvement in the crystallinity, such as a decrease of the FWHM value and an increase of the $T_c$. Compared to the un-doped wire heat-treated at $650^{\circ}C$ for 30 min, the $J_c$ was enhanced by the C doping in a high-field regime. The wire heat-treated at $900^{\circ}C$ resulted in a higher magnetic $J_c$ of approximately $10^4\;A/cm^2$ at 5 K and 8 T.

  • PDF