• Title/Summary/Keyword: CM method

Search Result 6,970, Processing Time 0.047 seconds

Assessment of Positioning Accuracy of UAV Photogrammetry based on RTK-GPS (RTK-GPS 무인항공사진측량의 위치결정 정확도 평가)

  • Lee, Jae-One;Sung, Sang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.63-68
    • /
    • 2018
  • The establishment of Ground Control Points (GCPs) in UAV-Photogrammetry is a working process that requires the most time and expenditure. Recently, the rapid developments of navigation sensors and communication technologies have enabled Unmanned Aerial Vehicles (UAVs) to conduct photogrammetric mapping without using GCP because of the availability of new methods such as RTK (Real Time Kinematic) and PPK (Post Processed Kinematic) technology. In this study, an experiment was conducted to evaluate the potential of RTK-UAV mapping with no GCPs compared to that of non RTK-UAV mapping. The positioning accuracy results produced by images obtained simultaneously from the two different types of UAVs were compared and analyzed. One was a RTK-UAV without GCPs and the other was a non RTK-UAV with different numbers of GCPs. The images were taken with a Canon IXUS 127 camera (focal length 4.3mm, pixel size $1.3{\mu}m$) at a flying height of approximately 160m, corresponding to a nominal GSD of approximately 4.7cm. As a result, the RMSE (planimetric/vertical) of positional accuracy according to the number of GCPs by the non-RTK method was 4.8cm/8.2cm with 5 GCPs, 5.4cm/10.3cm with 4 GCPs, and 6.2cm/12.0cm with 3 GCPs. In the case of non RTK-UAV photogrammetry with no GCP, the positioning accuracy was decreased greatly to approximately 112.9 cm and 204.6 cm in the horizontal and vertical coordinates, respectively. On the other hand, in the case of the RTK method with no ground control point, the errors in the planimetric and vertical position coordinates were reduced remarkably to 13.1cm and 15.7cm, respectively, compared to the non-RTK method. Overall, UAV photogrammetry supported by RTK-GPS technology, enabling precise positioning without a control point, is expected to be useful in the field of spatial information in the future.

GFRs Measured by Gates' Method According to 5 Background Sites: Comparison with GFR Measured by I-125-Iothalamate Method (다양한 배후 방사능 설정에 따른 Cates 법 사구체 여과율의 차이: I-125-Iothalamate 측정법과의 비교)

  • Jung, Hyun-Seok;Chung, Yong-An;Kim, Sung-Hoon;Kim, Chung-Ho;Lee, Sung-Young;Sohn, Hyung-Seon;Baik, Jun-Hyun;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.306-310
    • /
    • 2004
  • Purpose: The aim was to assess how the background site affects the Gates' glomerular filtration rate(GFR) measurement using Tc-99m-DTPA in correlation with GFR by I-125-lothalamate method. Material and methods: The study populations were 63 adults with 39 men and 24 women aged from 20 to 59 yrs (mean=37.9 yrs). The fellowing five background regions of interest were used in measurement of GFR using Gates' method: 1) lower side of each kidney(subrenal), 2) around each kidney(circumferential), 3) upper side of each kidney(suprarenal), 4) lateral side of each kidney(lateral), 5) between the two kidneys(inter-renal). We also measured GFR using I-125-iothalamate in each subject. The two studies were separated by 1 to 3 weeks. The subjects were divided into two groups by renal depth. Group 1 with renal $depth{\geq}7cm$ and group 2 with renal depth<7cm. We calculated the means and standard deviations of the GFRs measured by two studies. And we statistically analyzed the correlation and differences among GFRs by Gates' method and the GFR by iothalamate method with correlation analysis. Results: The GFRs by Gates' method using suprarenal and inter-renal background correction showed better correlation with the GFR measured by I-125-iothalamate. And GFRs measured by Gates' method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm. But GFRs measured by Gates' method did not show statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal $depth{\geq}7cm$. Conclusion: GFRs measured with Gates' method showed higher correlation with the GFR measured by I-125-iothalamate when the regions of interest were plated over the suprarenal and inter-renal backgrounds. And GFRs measured with Gates method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm.

The effects of the powder packing density on the Bi-2223/Ag tape in PIT(powder-in-tube) method (PIT법에서 분말 충진밀도가 Bi-2223/Ag 선재에 미치는 효과)

  • 김성환;유재무;고재웅;박성창;박명제;정형식;김철진
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.101-104
    • /
    • 2002
  • The influences of the powder packing density on the Bi-2223/Ag tape have been investigated. For packing powder, both method of uniaxial press and packed rod form made by cold isostatic press(CIP) have been applied. As the pressure of cold isostatic press(CIP) is increased, fill factor and critical current (Ic) of Bi-2223/Ag tape is increased. At a pressure of 2000kgf/cm$^2$, fill factor reach ∼3l% and this sample has the engineering current density(Je) value of ∼8.5kA/cm$^2$(Ic ∼77A, Jc ∼ 30kA/cm$^2$). The tape sample packed by uniaxial press method shows more sawsaging effect than the sample processed by cold isostatic press(CIP), resulting from inhomogity of powder distribution produced by the process of uniaxial press.

  • PDF

Correction of Fluctuation Pressure by Tube System (튜브시스템에서 변동풍압의 보정)

  • You, Ki-Pyo;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.1 s.3
    • /
    • pp.67-73
    • /
    • 2002
  • Measurement of fluctuating pressure by tube system is carefully designed due to the organ-pipe resonance. It is necessary to correct the pressure before analysis. The three method for correction the distortion fluctuation pressure short tube length and the frequency response functions and insert a restrictor in the tube to increase the damping. The first method is useful when the tube length is short. In second method, the distorted signal through the tubing transformed into the frequency domain, dividing by transfer function and inverse fourier transforming back into the time domain gives the required pressure signal. In this paper three types of tubing which have different length of 100cm, 150cm, 200cm were experimented the distorted signal and correct the distortion signal

  • PDF

An Experimental Study on the Effect of Consolidation Improvement Using Horizontal Drains (수평배수재를 이용한 압밀개량효과에 대한 실험연구)

  • 김지용;김정기;장연수;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.33-40
    • /
    • 2000
  • The horizontal drain method is one of the soil improvement methods in reclamation works using dredged soils. In this method, plastic drain boards are installed horizontally in the ground, and a seepage pressure or negative pressure is applied through one end of these drains. In this study, a basic consolidation test using horizontal drains was conducted to investigate the effectiveness of this method. The configuration of soil box which was used in this test is 100cm(B)${\times}$100cm(L)${\times}$85cm(H). The drain board was reduced to 25mm${\times}$5mm. The variations in settlement and volume of drain water during the consolidation process were measured, and the distribution of water content and the transpormation of horizontal drain were investigated.

  • PDF

Electrochemical Potentiostatic Activation & Its Application for Enhancing blue LED Efficiency

  • Kim, Bong-Jun;Kim, Hak-Jun;Lee, Yeong-Gon;Baek, Gwang-Seon;Lee, Jun-Gi;Kim, Jin-Hyeok;Sadasivam, Karthikeyan Giri
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.56.1-56.1
    • /
    • 2010
  • A novel electrochemical potentiostatic method has been examined in order to enhance the hole concentration of p-type GaN thin films using KOH and HCl electrolyte. The hole concentration was increased more than 2 times by the electric voltge apply with the mobility of $10{\sim}12cm^2/V.s$. At optimum condition of 3V apply, hole concentration was enhanced more than reference sample from $1.7{\times}10^{-17}cm^{-3}$ to $4.1{\times}10^{-17}cm^{-3}$. Application of this activation method to blue-LED fabrication improved optical output from 18.4mW to 20.6mW, that is ~12% increase. SIMS analysis indicates that nearly 70% of hydrogen atoms could be removed by this method.

  • PDF

Development of a Pants Pattern for Chinese Women in Their 20s Using a Virtual Fitting Method

  • Wu, Nan;Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.986-1003
    • /
    • 2021
  • This study was conducted to develop a basic pants pattern reflecting the average body shape of Chinese women in their 20s by using a virtual fitting method. A formula for the research pattern was derived by applying the measured value based on the drafting method of existing patterns. The final pattern was presented through two actual fitting processes. The suitability of the final pattern was then verified through a functional evaluation and an appearance evaluation based on an actual fitting and a virtual fitting. As a result of the evaluations, the final pattern reflected the body shape of Chinese women in their 20s and was evaluated as a higher quality pattern compared to existing patterns. The final pattern was based on the omphalion waist circumference. Ease amounts were set to be the omphalion waist circumference + 1.0 cm, hip circumference + 2.0 cm, and the pants length was set to 94 cm.

Dielectrical and Pyroelectrical Properties of $Pb(Zn_{1/3}Nb_{2/3})O_3-Pb(Zr_xTi_{1-x})O_3$ Compound Ceramics ($Pb(Zn_{1/3}Nb_{2/3})O_3-Pb(Zr_xTi_{1-x})O_3$세라믹의 유전 및 초전 특성)

  • 이성갑;조현무
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.10
    • /
    • pp.796-801
    • /
    • 2001
  • Ferroelectric 0.05PZN-xPZT(90/10)-(0.95-x)PZT(10/90) (x=0.65, 0.85) specimens were fabricated by the solid-state reaction method, and especially PZT(90/10) and PZT(10/90) powders were derived by the sol-gel method. All specimens showed a uniform ferroelectric grain without the presence of the pyrocholre phase. Average grain size increased with an increased in sintering temperature, the values for the x=0.65 and x=0.85 specimens sintered at 125$0^{\circ}C$ were 14.4$\mu$m and 9.8$\mu$m, respectively. The dielectric constant and dielectric loss of the x=0.65 specimen sintered at 125$0^{\circ}C$ were 1247. 2.06%, respectively. The coercive field and the remanent polarization of x=0.65 and x=0.85 specimens sintered at 125$0^{\circ}C$ were 8.5kV/cm, 13$\mu$C/$\textrm{cm}^2$ and 17.2kV/cm, 28 $\mu$C/$\textrm{cm}^2$, respectively. The pyroelectric coefficient of the x=0.65 and x=0.85 specimens sintered at 125$0^{\circ}C$ were 5.64$\times$10$^{-8}$ C/$\textrm{cm}^2$K and 2.76$\times$10$^{-8}$ C/$\textrm{cm}^2$K, respectively.

  • PDF

Characteristics of Field Uplift Tests of Continuous Greenhouse using the Load Control Method (하중 제어법을 이용한 파이프 줄기초의 현장 인발저항 특성)

  • Lim, Seong-Yoon;Kim, Myeong-Hwan;Kim, Yu-Yong;Yu, Seok-Chul;Kim, Seok-Jin;Lim, Jae-Sam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.4
    • /
    • pp.105-111
    • /
    • 2018
  • Institutional inertia anti-disaster standard was presented mainly on the upper surface, it is necessary to improve to the soil type standard and uplift the resistance standard greenhouse that are vulnerable to strong winds. In this study, we carried out a field test using the load control method in order to evaluate the uplift resistance of continuous foundation of greenhouse with different depths of the rafters. Institutional inertia anti-disaster standard of greenhouse foundation did not protect the greenhouse structure from the damages caused by strong winds and heavy snow. Therefore, field tests for behavior characteristics of continuous greenhouse foundation were carried out to ensure stable facility cultivation. The field test condition was evaluated using different embedded depth as follows: 30cm, 40cm, 50cm and spacing 50cm, 60cm, 70 cm. As a result of the uplift resistance field tests using the load control method, the minimum uplift resistance was found to be over 90kg and uplift resistance displacement was 9.4mm. Uplift resistance of the continuous greenhouse foundation was in the range of 90-180 kg according to embedded depth and spacing. Using the test condition, there was no constant trend in the uplift resistance.

Growth of 6H-SiC Single Crystals by Sublimation Method (승화법에 의한 6H-SiC 단결정 성장)

  • 신동욱;김형준
    • Korean Journal of Crystallography
    • /
    • v.1 no.1
    • /
    • pp.19-28
    • /
    • 1990
  • 6H-SiC is a promising material (Eg=3.0eV) for blue light-emitting doide and high-temperature semiconducting device. In the experiment, single crystals of a-SiC have been grown by the sublimation method to fabricate blue light~emitting diode. During the growth of a-SiC single crystals, a temperature Vadient, yonh temperature and pressure ranges were kept 44℃/cm , 1800-1990℃ and 50-1000 mTorr, respectively. Single crystals obtained in Acheson furnace were used as seed crystals. Polarizing microscopy and back-reflection X-ray Laue diffraction showed that the a-SiC crystal was epitaxially and on the seed crytal. It was found by XRD analysis that when other growth conditions were the same, a-SiC was grown at the temperature above 1840℃ and 3C-SiC was gown at lower temperature or under low supersaturation of vapor. The carrier type. concentration and mobility were measured be hole(p-type), 7.6x1014cm-3 and 19cm2V-1sec-1, respectively, by van der Pauw method.

  • PDF