• 제목/요약/키워드: CM Tools

검색결과 112건 처리시간 0.03초

청소년기 특발성 척추측만증 환자의 임상적 균형 평가지수와 균형 수행 모니터 측정값의 상관성 연구 (The study of correlations between clinical balance scales and balance performance monitor parameters in patients with adolescent idiopathic scoliosis)

  • 신승섭
    • PNF and Movement
    • /
    • 제8권3호
    • /
    • pp.39-47
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the correlations between clinical balance scales and Balance Performance Monitor parameters in patient with adolescent idiopathic scoliosis (AIS). Methods : Twenty AIS subjects (age, $14.26{\pm}1.93yrs$; height, $160.56{\pm}7.98cm$; weight, $47.54{\pm}6.94kg$)were participated in this study. Postural sway(mean balance, sway angle, sway area, sway path, maximal sway velocity) were were evaluated by balance performance monitor. Measurements for clinical balance scales were Functional reach test (both side), the Lateral reach test (both side) and One leg standing test (both legs). Results : The results were as follows. There were positive strong correlation between major curve direction and left-right sway angle, sway path, maximal sway velocity. There were negative strong correlation between the functional reach and left-right sway angle, sway area, sway path, maximal sway velocity. And the lateral reach were also showed negative strong correlation parameters of balance performance monitor. One leg standing were negatively correlated with left-right sway angle, sway path, maximal sway velocity. Conclusion : The clinical balance scales will be useful tools for balance measurements, and basic tools for clinical setting for patient with AIS.

  • PDF

유기농 시설엽채류의 유해미생물 오염평가 (Analysis of Pathogenic Microorganism's Contamination on Organic Leafy Vegetables at Greenhouse in Korea)

  • 오소영;남기웅;윤덕훈
    • 한국식품위생안전성학회지
    • /
    • 제33권1호
    • /
    • pp.31-37
    • /
    • 2018
  • 본 연구는 시설엽채류에서 재배농법별 미생물학적 안전성을 평가하기 위해서 깻잎과 상추를 대상으로 수행하였다. 유기농 및 관행 농가로부터 생산 및 수확 단계에서 식물체, 수확장갑, 수확비구니, 토양피복재 등으로부터 총 2,304개의 시료를 채취하여 Total aerobic bacteria, Coliforms, E.coli, Environmental Listeria, Yeast & mold 등의 위생지표세균과 Staphylococcus aureus, Bacillus cereus, Salmonella spp., Clostridium spp., L. monocytogenes등의 병원성미생물을 분석하였다. 시설엽채류의 생산과정에서는 재배농법에 상관없이 위행지표세균은 검출되지 않거나 $3.4\;Log\;CFU/100cm^2$ 이하로 검출되었다. 유기농법으로 생산되는 깻잎과 상추에서 B. cereus와 S. aureus가 0.22~1.55 Log CFU/g로 조사되었고, 관행농법에서는 S. aureus는 검출되지 않았으며 B. cereus는 0.42~2.19 Log CFU/g으로 조사되었으나 통계적 유의차는 없었다. 수확도구 및 멀칭필름에서도 재배농법과는 관계없이 위생지표세균과 유해균의 오염도는 낮았으며 차이는 없었다. 그러나 수확도구에서의 미생물 오염도가 높아질수록 식물체 표면의 미생물 오염도도 높아지는 정의 상관관계($R^2=0.4526$)가 있었다. 또한 유기농 시설엽채류 생산시 토양 피복시 위생지표세균과 병원성미생물이 검출되지 않거나 피복을 하지 않은 경우에 비하여 낮은 경향을 나타내었다. 본 연구결과, 시설엽채류 생산시 재배농법의 차이보다는 토양피복 및 수확과정의 미생물적 위생관리가 더욱 필요함을 알 수 있었다.

EPID의 적정관리 도구로서의 유용성에 관한 연구 (The useage of the EPID as a QA tools)

  • 조정희;방동완;윤성익;박재일
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

Clinical Features of Symptomatic Meckel's Diverticulum in Children: Comparison of Scintigraphic and Non-scintigraphic Diagnosis

  • Rho, Jung Hee;Kim, Jae Sook;Kim, Sang Yong;Kim, Soon Ki;Choi, Yoon Mi;Kim, Sung Min;Tchah, Hann;Jeon, In Sang;Son, Dong Woo;Ryoo, Eell;Cho, Kang Ho;Choi, Deok Young;Kim, Yoon Mi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제16권1호
    • /
    • pp.41-48
    • /
    • 2013
  • Purpose: Meckel's diverticulum (MD) has various clinical manifestations, and diagnosis or selectection of proper diagnostic tools is not easy. This study was conducted in order to assess the clinical differences of MD diagnosed by scintigraphic and non-scintigraphic methods and to find the proper diagnostic tools. Methods: We conducted a retrospective review ofthe clinical, surgical, radiologic, and pathologic findings of 34 children with symptomatic MD, who were admitted to Gachon University Gil Medical Center, Inha University Hospital, and The Catholic University of Korea, Incheon St. Mary's Hospital between January 2000 and December 2012. The patients were evaluated according to scintigraphic (12 cases; group 1) and non-scintigraphic (22 cases; group 2) diagnosis. Results: The male to female ratio was 7.5: 1. The most frequent chief complaint was lower gastrointestinal (GI) bleeding in group 1 and nonspecific abdominal pain in group 2, respectively. The most frequent pre-operative diagnosis was MD in both groups. Red blood cell (RBC) index was significantly lower in group 1. MD was located at 7 cm to 85 cm from the ileocecal valve. Four patients in group 1 had ectopic gastric tissues causing lower GI bleeding. The most frequent treatment modality was diverticulectomy in group 1 and ileal resection in group 2, respectively. Conclusion: To diagnose MD might be delayed unless proper diagnostic tools are considered. It is important to understand indications of scintigraphic and non-scintigraphic methods according to clinical and hematologic features of MD. Scintigraphy would be weighed in patients with anemia as well as GI symptoms.

안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가 (Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan)

  • 문세영;홍상우;서지숙;김영범;곽완신;이성영;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

비만 여성의 체형 특성 분석을 위한 비만 판정 지수의 비교 (A Comparative Study on Obesity Judgment Indices for Body Characteristics Analysis in Korean Obese Women)

  • 이경화
    • 복식문화연구
    • /
    • 제17권6호
    • /
    • pp.1141-1154
    • /
    • 2009
  • As a preliminary research of body characteristics analysis of Korean obese woman, this study aims to select optimal obesity judgment tools for reliable sampling of obese subjects from 2,425 female measurement data out of 2004 Size Korea project's raw data. From previous researches related to obesity, 7 obesity judgment tools were chosen. 2007 obesity rate(26.3%) of Korean female adults was refered in selecting optimal obesity judgment criteria in the study. The results are as follows. Firstly, it was verified that BMI was the most suitable in judging and sampling the obese subjects by the percentile analysis. R$\ddot{o}$hrer index was also reliable in grouping the obese subjects from a population. Secondly, it was concluded that the obesity ratios of relative weight 120 and higher group, R$\ddot{o}$hrer index 1.6 and higher group and waist girth 80cm and higher group were the most similar to obesity rate of Korean female adults by 2007 National Health & Nutrition Survey. Thirdly, 30 direct measurements, age, 2 drop values and 6 ratios of 7 groups by the obesity judgment tools showed the significance each other at p<0.001 level. On the other hand, "bust point to bust point" and "waist to hip length" measurements didn't show the significant differences among 7 groups. Conclusively, 4 to 5 satisfactions out of 7 obesity judgment criteria were adequate and sufficient in sampling the obese subjects. If it is needed the strict criteria for judging the obesity, 5 satisfactions and higher group will be the best choice as the obese subjects. However 4 satisfactions and higher group generally, will be adequate for sampling of the obese subjects.

  • PDF

Surface energy change and hydrophilic formation of PE, PS and PTFE films modification by hydrogen ion assisted reaction

  • Jung Cho;Ki Hyun;Koh, Seok-Keun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.202-202
    • /
    • 1999
  • The Polyethylene (PE), Polystyrene (PS) and Polytetrafluoroethylene (PTFE) surface modification was investigated by hydrogen io assisted reaction (H-IAR) in oxygen environment. The IAR is a kind of surface modification techniques using ion beam irradiation in reactive gas environment. The energy of hydrogen ion beam was fixed at 1keV, io dose was varied from 5$\times$1014 to 1$\times$1017 ions/$\textrm{cm}^2$, and amount of oxygen blowing gas was fixed 4ml/min. Wettability was measured by water contact angles measurement, and the surface functionality was analyzed by x-ray photoelectron spectroscopy. The contact angle of water on PE modified by argon ion beam only decrease from 95$^{\circ}$ to 52$^{\circ}$, and surface energy was not changed significantly. But, the contact angle using hydrogen ion beam with flowing 4ml/min oxygen stiffly decreased to 8$^{\circ}$ and surface energy to 65 ergs/cm. In case of PS, the contact angle and surface energy changes were similar results of PE, but the contact angle of PTEE samples decreased with ion dose up to 1$\times$1015 ions/$\textrm{cm}^2$, increased at higher dose, and finally increased to the extent that no wetting was appeared at 1$\times$1017 ions/$\textrm{cm}^2$. These results must be due to the hydrogen ion beam that cleans the surface removing the impurities on polymer surfaces, then hydrogen ion beam was activated with C-H bonding to make some functional groups in order to react with the oxygen gases. Finally, unstable polymer surface can be changed from hydrophobic to hydrophilic formation such as C-O and C=O that were confirmed by the XPS analysis, conclusionally, the ion assisted reaction is very effective tools to attach reactive ion species to form functional groups on C-C bond chains of PE, PS and PTFE.

  • PDF

폐경기 골다공증 환자의 골다공증 지식, 건강신념, 자기효능감이 칼슘섭취행위 빈도에 미치는 영향 (Effects of the Knowledge, Health Belief, and Self-Efficacy about Osteoporosis on Calcium Intake Behavior for Postmenopausal Osteoporosis Patients)

  • 송혜란;소희영
    • 성인간호학회지
    • /
    • 제19권5호
    • /
    • pp.80-91
    • /
    • 2007
  • Purposes: To identify the predictors of calcium intake behavior and examine the relationships among bone mineral density, osteoporosis knowledge, osteoporosis health belief, osteoporosis self efficacy and calcium intake behavior of postmenopausal osteoporosis patients. Methods: The subjects consisted of 94 patients. The measurement tools were osteoporosis knowledge test, osteoporosis health belief scale, osteoporosis self-efficacy and calcium intake frequency questionnaire. The data were analyzed using the SPSS WIN 11.0 program. Results: The bone mineral density of the lumbar were $0.75g/cm^2$, T-score -2.67 and the femur neck were $0.67g/cm^2$, T-score -2.30. There was statistically a significant correlation between calcium intake behavior and health motivation (r=0.449, p=0.000) among the osteoporosis health belief. In hierarchial multiple regression analysis, current spouse(12.8%) and health motivation(19.9%) of the osteoporosis health belief explained the 32.7% of variance in calcium intake behavior. Conclusion: Nursing intervention should be developed for increasing the calcium intake behavior through promoting health motivation for the postmenopausal osteoporosis women having no spouse currently.

  • PDF

에너지 절약형 공기압 시스템 특성에 관한 연구 (A Study on the Energy Saving Type Pneumatic System Characteristics)

  • 김형의;김동수;강보식;성백주
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.91-98
    • /
    • 1995
  • Recently, improving the energy efficiency of a pneumatic system and reducing the consumption of compressed air were a concern of scholars at domestic and abroad. The using fields of a pneumatic system are widely used in factory automation of manufacturing line, chemical factories with explosiveness danger and petroleum industries etc. In particular, pneumatic cylinder is applied to feeding work of workpiece. jig tools and press mechanism, reciprocation and rotary motion with rack and pinion. In this study, the experimental apparatus consisted to pneumatic cylinder, dual supply pressure regulator and solenoid valve. The dual supply pressure regulator connected to outlet port of solenoid valve. The supply pressure($4.5kg_f/cm^2$) of compressed air goes into the rodless chamber 1 to drive the piston rod forward which is named working stage. The supply pressure ($2kg_f/cm^2$) of compressed air goes into the rod chamber 2 to drive the piston rod backward which is named no-working stage. Accordingly, the research results of this study can be obtained to Energy-Saving Effects of the compressed air about 35%.

  • PDF

Good Agricultural Practices (GAP)모델 개발을 위한 부추 및 생산환경에서의 위해요소 조사 (Investigation of Microbiological Hazard from Korean Leeks and Cultivation Area to Establish the GAP Model)

  • 박상곤;최영동;이채원;정명진;김정숙;정덕화;심원보
    • 한국식품위생안전성학회지
    • /
    • 제30권1호
    • /
    • pp.28-34
    • /
    • 2015
  • 부추의 위해요소관리를 위한 GAP 모델 개발에 필요한 기초 자료로 활용하기 위해 부추 생산과정을 재배전 단계, 재배단계 및 수확 포장단계로 나누어 재배환경 (토양, 용수), 부추, 개인위생 시료에 대해 위생지표세균, 병원성 미생물, 곰팡이의 오염도를 조사하였다. 위생지표 세균 중 일반세균은 토양 6.4~6.7 log CFU/g, 부추 4.6~5.1 log CFU/g, 개인위생 중 손과 장갑에서 각각 최대 3.3 및 5.4 log CFU/hand or $cm^2$으로 검출되었고, 그 외의 시료에서는 2.7 log CFU/g (or mL, hand, $100cm^2$) 이하로 검출되었다. 대장균군은 토양 3.9~4.2 log CFU/g, 부추 4.8~5.0 log CFU/g으로 부추에서 더 높은 수준으로 검출되었고, 대장균은 모든 시료에서 불검출 되었다. 병원성 미생물의 경우 B. cereus만 용수를 제외한 시료에서 0.5~4.6 log CFU/g (or hand, $100cm^2$) 수준으로 검출되었다. 곰팡이의 경우도 용수와 일부 작업도구를 제외한 시료에서 2.1~3.8 log CFU/g (or hand, $100cm^2$) 수준으로 검출되었다. 전반적으로 토양과 닿아 있는 부추에서의 미생물 오염도가 높게 확인되었으며, 이는 비교적 미생물의 오염도가 높은 토양으로부터 교차오염이 발생하였기 때문인 것으로 판단된다. 따라서 부추의 생물학적 위해요소에 대한 안전성 확보를 위해서는 토양 관리가 중요할 것으로 생각 된다.