• Title/Summary/Keyword: CM Tools

Search Result 112, Processing Time 0.022 seconds

A CT Simulator Phantom for Geometrica1 Test (CT 시뮬레이터의 기하학적 성능평가용 팬톰)

  • Min, Chul-Kee;Yi, Byong-Yong;Ahn, Seung-Do;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.337-344
    • /
    • 2000
  • Purpose :To design and test test CT simulator phantom for geometrical test. Materials and Methods : The PMMA phantom was designed as a cylinder which is 20 cm in diameter and 24 cm in length, along with a 25$\times25\times31cm^{3}$ rectangular parallelepiped. Radio-opaque wires of which diameter is 0.8 mm are attached on the other surface of the phantom as a spiral. The rectangular phantom was made of four 24$\times24\times0.5 cm^{3}$ square plates and each plate had a 24$\times24 cm^{2}$, 12$\times12cm^{2}$, 6$\times6 cm$^{2}$ square line. The squares were placed to face the cylinder at angles 0 $^{\circ}$ , 15 $^{\circ}$ , 30 $^{\circ}$ ,respectively. The rectangular phantom made it possible to measure the field size, couch angle, the collimator angle, the isocenter shift and the SSD, the measurements of the gantry angle from the cylindrical part. A virtual simulation software, AcOSim, offered various conditions to perform virtual simulations and these results were used to perform the geometrical Quality assurance of CT simulator. Results : A 0.3$\~$0.5 mm difference was found on the 24 cm field size which was created with the DRR measurements obtained by scanning of the rectangular phantom. The isocenter shift, the collimator rotation, the couch rotation, and the gantry rotation test showed 0.5$\~$1 mm, 0.5$\~$l$^{\circ}$ 0.5$\~$ 1$^{\circ}$ , and 0.5-1 $^{\circ}$ differences, respectively. We could not find any significant differences between the results from the two scanning methods. Conclusion :The geometrical test phantom developed in the study showed less than 1 mm (or 1 $^{\circ}$ ) differences. The phantom could be used as a routine geometrical QC/QA tools, since the differences are within clinically acceptable ranges.

  • PDF

Development of a Model Instrument of Thermal Power Plant for Understanding of Air Pollutant Generation

  • Yamamoto, Mariko;Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.3
    • /
    • pp.156-161
    • /
    • 2016
  • In order to deal with current environmental issues and their backgrounds, further development of current teaching methods and tools are essential. The result of questionnaire performed in this study indicates that the effect and the change of the perception of power generation in Japan after the great disaster of East Japan have caused many students (both high school and college students) to become interested in the energy situation. In the present study, we made an attempt to develop a model instrument of a thermal power plant that can be applied as a teaching tool for understanding of air pollutant forming as well as power generation. Our novel model tool consists of a body (30 cm width, 21 cm depth, and 41 cm height), a combustion chamber, two motors, a boiler, a voltmeter, and a chimney for measurement of exhaust gas. Using our novel hand-made power plant, we carried out some model experiments with learners (i.e. high school and college students). Through model experiments, students can be experienced not only about power generation but also about generation of air pollutants. In order to estimate the applicability of our novel instrument as an educational tool, we carried out the questionnaires before and after model experiments. More than 80% of educatees reported that it was very useful as a teaching tool for energy and environmental education. The results of questionnaires indicated that learners achieved a very deep understanding of the principles of power generation and the forming of air pollutants.

Inhibitory effects of ultraviolet-C light and thermal treatment on four fungi isolated from pig slaughterhouses in Korea

  • Lee, Eun-Seon;Kim, Jong-Hui;Kang, Sun Moon;Kim, Bu-Min;Oh, Mi-Hwa
    • Journal of Animal Science and Technology
    • /
    • v.64 no.2
    • /
    • pp.343-352
    • /
    • 2022
  • Pig slaughterhouses harbor high humidity because of the necessary cleaning that takes place simultaneously with slaughter, which facilitates the existence of mold. Due to the enclosed space, there are several limitations to the control of mold growth with respect to cleaning, ventilation, and drying. In this study, the prevalence of fungi was investigated in four pig slaughterhouses in Korea. Four fungi (Aspergillus niger, Penicillium commune, Penicillium oxalicum, and Cladosporium cladosporioides) were detected with the highest frequency. These four strains were subjected to various treatments to reduce their growth. The fungi were inoculated onto stainless steel (SS) chips and treated with ultraviolet (UV)-C irradiation and hot water. Individual treatments with UV-C (15, 30, 90, 150, 300, and 600 mJ/cm2), and hot water (60, 65, 70, and 83℃) were performed to sanitize the SS chips. Simultaneous cleaning with 60℃ hot water and more than 150 mJ/cm2 of UV-C reduced the fungal incidence by > 6.5 Log from 6.6-7.0 Log CFU/cm2 (initial count). Our results demonstrate that a combined treatment of UV-C and hot water is the most economical and convenient way to prevent microbiological contamination of small tools (such as knives and sharpeners) and steel surfaces in slaughterhouses.

Localized necking condition of sheet metals is subjected to out-of plane force (면외압을 받는 판재의 국부네킹 발생 조건)

  • 정태훈
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.579-584
    • /
    • 2002
  • In press forming of sheet metals, the material sheet is usually subjected to very large plastic strain under in-plane stressing. Moreover, the sheet also very often is subjected to out-of-plane compressive force between tools such as the upper and lower dies, the blank holder and the die, and so forth. In this paper, it is clearly demonstrated theoretically that out-of-plane stress may notably raise the forming limit strain and thus it cm be effectively utilized to avoid earlier fracture of the sheet in press forming.

  • PDF

RSFQ DFFC Circuit Design for Usage in developing ALU (ALU의 개발을 위한 RSFQ DFFC 회로의 설계)

  • 남두우;김규태;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.123-126
    • /
    • 2003
  • RSFQ (Rapid Single Flux Quantum) circuits are used in many practical applications. RSFQ DFFC (Delay Flip-Flop with complementary outputs) circuits can be used in a RAM, an ALU (Arithmetic Logic Unit), a microprocessor, and many communication devices. A DFFC circuit has one input, one switch input, and two outputs (output l and output 2). DFFC circuit functions in such way that output 1 follows the input and output 2 is the complement of the input when the switch input is "0." However, when there is a switch input "1."the opposite output signals are generated. In this work, we have designed an RSFQ DFFC circuit based on 1 ㎄/$\textrm{cm}^2$ niobium trilayer technology. As circuit design tools, we used Xic, WRspice, and Lmeter After circuit optimization, we could obtain the bias current margins of the DFFC circuit to be above 32%.

  • PDF

Optimal Design of GaN Power MOSFET Using Al2O3 Gate Oxide (Al2O3 게이트 절연막을 이용한 GaN Power MOSFET의 설계에 관한 연구)

  • Nam, Tae-Jin;Chung, Hun-Suk;Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.9
    • /
    • pp.713-717
    • /
    • 2011
  • This paper was carried out design of 600 V GaN power MOSFET Modeling. We decided trench gate type one for design. we carried out device and process simulation with T-CAD tools. and then, we have extracted optimal device and process parameters for fabrication. we have analysis electrical characteristics after simulations. As results, we obtained 600 V breankdown voltage and $0.4\;m{\Omega}cm^2ultra$ low on resistance. At the same time, we carried out field ring simulation for obtaining high voltage.

Physical Property Analysis of Composite Electrodes with Different Active Material Sizes and Densities using 3D Structural Modeling (3차원 구조 모델링을 이용한 활물질 입자 크기 및 전극 밀도에 따른 복합 전극 내 물리적 특성 분석)

  • Yang, Seungwon;Park, Joonam;Byun, Seoungwoo;Kim, Nayeon;Ryou, Myung-Hyun;Lee, Yong Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.2
    • /
    • pp.39-46
    • /
    • 2020
  • Composite electrodes for rechargeable batteries generally consist of active material, electric conductor, and polymeric binder. And their composition and distribution within the composite electrode determine the electrochemical activity in the electrochemical systems. However, it is not easy to quantify the physical properties of composite electrodes themselves using conventional experimental analysis tools. So, 3D structural modeling and simulation can be an efficient design tool by looking into the contact areas between particles and electric conductivity within the composite electrode. In this study, while maintaining the composition (LiCoO2 : Super P Li® : Polyvinylidene Fluoride (PVdF) = 93 : 3 : 4 by wt%) and loading level (13 mg cm-2) of the composite electrode, the effects of LiCoO2 size (10 ㎛ and 20 ㎛) and electrode density (2.8 g cm-3, 3.0 g cm-3, 3.2 g cm-3, 3.5 g cm-3, 4.0 g cm-3) on the physical properties are investigated using a GeoDict software. With this tool, the composite electrode can be efficiently designed to optimize the contact area and electric conductivity.

Clinical Features of Symptomatic Meckel's Diverticulum (증후성 멕켈 게실의 임상적 고찰)

  • Lee, Young Ah;Seo, Ji Hyun;Youn, Hee Sang;Lee, Gyeong Hun;Kim, Jae Young;Choi, Gwang Hae;Choi, Byung Ho;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.2
    • /
    • pp.193-199
    • /
    • 2006
  • Purpose: The proper diagnosis of Meckel's diverticulum (MD) is difficult and delayed because of the variety of clinical manifestations. We reviewed clinical characteristics of symptomatic MD to facilitate early detection. Methods: We analyzed retrospectively the clinical manifestations, diagnostic tools, histopathological findings, and operative findings in 58 patients with symptomatic MD. Results: The male to female ratio was 2.8 : 1. The most common symptom of MD was bleeding. Others symptoms included: vomiting, abdominal pain, irritability, abdominal distension and fever in the order of frequency. The clinical manifestations of symptomatic MD were lower gastrointestinal bleeding, intestinal obstruction, perforation, diverticulitis and hemoperitoneum, in the order of frequency. The causes of intestinal obstruction were intussusception, internal hernia, band, volvulus, invagination, in the order of frequency. Seventy five percent of patient with MD were diagnosed prior to 5 years of age. The most frequently used diagnostic tool was the Meckel's scan. The diverticulum was located 2 cm to 120 cm proximal to the ileocecal valve. The length of the diverticulum ranged from 1 cm to 10 cm and 94% were less than 5 cm. The most common ectopic tissue found in the MD was gastric mucosa. Ileal resection was more frequently performed than diverticulectomy. Conclusion: In cases of unexplained gastrointestinal bleeding, obstruction and repeated intussusception, the meckel's scan, ultrasound and computed tomography shoud be considered to rule out MD, and if clinically necessary, an exploratory laparotomy when needed.

  • PDF

Synthesis of SiNx:H films in PECVD using RF/UHF hybrid sources

  • Shin, K.S.;Sahu, B.B.;Lee, J.S.;Hori, M.;Han, Jeon G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.136.1-136.1
    • /
    • 2015
  • In the present study, UHF (320 MHz) in combination with RF (13.56 MHz) plasmas was used for the synthesis of hydrogenated silicon nitride (SiNx:H) films by PECVD process at low temperature. RF/UHF hybrid plasmas were maintained at a fixed pressure of 410 mTorr in the N2/SiH4 and N2/SiH4/NH3 atmospheres. To investigate the radical generation and plasma formation and their control for the growth of the film, plasma diagnostic tools like vacuum ultraviolet absorption spectroscopy (VUVAS), optical emission spectroscopy (OES), and RF compensated Langmuir probe (LP) were utilized. Utilization of RF/UHF hybrid plasmas enables very high plasma densities ~ 1011 cm-3 with low electron temperature. Measurements using VUVAS reveal the UHF source is quite effective in the dissociation of the N2 gas to generate more active atomic N. It results in the enhancement of the Si-N bond concentration in the film. Consequently, the deposition rate has been significantly improved up to 2nm/s for the high rate synthesis of highly transparent (up to 90 %) SiNx:H film. The films properties such as optical transmittance and chemical composition are investigated using different analysis tools.

  • PDF

Comparison of Effects of Transcutaneous Electrical Nerve Stimulation (TENS) and San-Yin-Jiao (SP6) Acupressure on Primary Dysmenorrhea (경피신경전기자극(TENS)과 삼음교 지압이 원발성 월경통에 미치는 효과 비교)

  • Oh, Yeong-Taek
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.415-424
    • /
    • 2014
  • PURPOSE: This study examined the effect of high-frequency transcutaneous electrical nerve stimulation (TENS) and San-Yin-Jiao (SP6) acupressure on primary dysmenorrhea. Furthermore, the difference in effectiveness between the two methods were compared. METHODS: Twenty-six students participated in this study, and were randomly assigned to a high-frequency TENS group(experimental 1, n=9), a San-Yin-Jiao (SP6) acupressure group(experimental 2, n=9), and no treatment group(control, n=8). They were assessed and treated on the first day of their menstruation. The TENS protocol included applying 20 minutes of stimulation with a frequency of 100Hz, $100{\mu}sec$ pulse width. Four electrodes were placed on the skin 3 cm from midline at T12-L1 and S2-3 paravertebral muscles. San-Yin-Jiao (SP6) acupressure should be applied with the thumb for 10 minutes(8 seconds pressure and 2 seconds rest) on the SP6 acupoint. This procedure should be repeated for the other foot. Dysmenorrheal pain measured two pain assessment tools (VAS, DPT) pre-treatment; immediate post-treatment; 30minutes, 1, 2hours; and 3, 4, 5, 6, 24 hours after the VAS test were added. RESULTS: The results showed significant differences in pain assessments (VAS, DPT) after treatment for subjects of experimental group1 (p<.05) and experimental group2 (p<.05), whereas the between-group comparison found no statistically significant differences. CONCLUSION: This result supports the idea that using two methods could be effective in pain reduction among students who suffered from primary dysmenorrhea.