• Title/Summary/Keyword: CM Signal

Search Result 605, Processing Time 0.025 seconds

Analysis of Distances for MRI Scan to Maintain Pptimal Signal Intensity in a Surface Coil (MRI 검사 시 코일내 최적의 신호강도를 유지할 수 있는 거리의 기준 분석)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.10
    • /
    • pp.158-164
    • /
    • 2018
  • The purpose of this study is to statistically analyze the signal intensity pattern according distance from the surface coil center and to maintain optimal signal intensity under clinical circumstances where the surface coil centers are not correctly positioned due to various causes. The cylindrical fluid phantom was placed and moved from the coil center in vertical direction with 1 cm increments. The signal intensities were measured and compared. As a result, the signal intensity showed no significant difference within 4 cm and 1 cm from in T1 weighted images while in T2 weighted images the signal intensity was maintained up to 5 cm and lower 3 cm in the upper and lower direction from the coil center. In conclusion, to maintain the optimal signal intensity the target region should be located within the reference distances proposed in this study.

A Performance Comparison of CR-MMA and CM-MMA Equalization Algorithm in 2-dimensional QAM System (2차원 QAM 시스템에서 CR-MMA 와 CM-MMA 등화 알고리즘의 성능 비교)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.85-90
    • /
    • 2018
  • This paper compares the adaptive eualization performance of CR-MMA (Constellation Reduction-MMA) and CR-MMA (Constellation Matching-MMA) in order to minimization of intersymbol interference that is occur in channel for 2-dimensional QAM signal. For obtain the error signal in order to updating the tap coefficient of conventional adaptive equalization algorithm MMA, the CR-MMA converts the constellation reduction concept of high order 2-dimensional QAM nonconstant modulus signal to constant modulus signal and the CM-MMA use the constellation matchine error concept in order to force the matching the $2^{nd}$ and $4^{th}$ cumulant of equalizer output and transmitted signal constellation. By applying the different method for getting the error signal, these algorithm are possible to obtain the improved equalization performance compared to the conventional MMA algorithm, the improved performance of CR-MMA and CM-MMA were compared by computer simulation in this paper. As a result of simulation, the CM-MMA has more better performance in the equalizer internal performance than CR-MMA, but not in equalizer external performance as in SER.

A Performance Comparison of CM-MMA and RMMA Blind Equalization Algorithm in QAM Signal Transmission (QAM 신호 전송에서 CM-MMA와 RMMA 블라인드 등화 알고리즘의 성능 비교)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.79-84
    • /
    • 2019
  • This paper compare the performance of CM-MMA (Constellation Matching-MMA) and RMMA (Region-based MMA) blind equalization algorithm for improve the QoS by minimizing the intersymbol interference that is occurred in nonlinear communication channel when transmitting the QAM signal. In the tap coefficient update for adaptive, CM-MMA use the error of nonconstant modulus signal adding the current MMA cost fuction and constellation matching error terms of sinusoidal power function, and the RMMA use the error by transfoms the nonconstant modulus signal of equalizer output constellation to 4-QAM constant modulus signal. They has different equalization performance by these error signal, it were compared in this paper by simulation, and performance index such as output signal constellation of equalizer, residual isi, maximum distortion, SER curves are applied for this. As a result of computer simulation, the RMMA has more better performance in the every performance index, convergence speed, residual value, noise robustness compared to CM-MMA.

Measurements of Saturation Energy Denity and Small Signal Gain Coefficient Dependent on the Active Gas Pressure in XeCl Laser Amplifier (XeCl 레이저 증폭기의 활성기체 압력에 따른 포화 에너지 밀도와 소신호 이득계수 측정)

  • 김규옥;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.457-460
    • /
    • 1994
  • Dependence of saturation energy density and small signal gain coefficient on the active gas pressure in XeCl laser amplifier has been investigated. The saturation energy density was increased almost linearly as 1.3, 1.45, 2.0, and $2.3mJ/\textrm{cm}^2$ when the pressure of Xe and He were 30 and 2000 mb, and the pressure of HC] was varied as 34, 52, 73, and 92 mb. Whereas the small signal gain coefficient was measured to be 6.5, 7.5, 7.0, 7.0 %/cm, which shows that the small signal gain did not varies not so much.o much.

  • PDF

Simulation of Signal Amplitudes and Signal-to-noise Ratios of $1^{st}$ order and $2^{nd}$ order Gradiometers with Various Baselines (다양한 기저선을 갖는 1차 및 2차 미분계의 신호크기 및 신호 대 잡음비 조사)

  • Kang, C.S.;Yu, K.K.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.40-44
    • /
    • 2007
  • We investigated signal-to-noise ratios (SNRs) of magnetocardiography (MCG) signals using the first-order and the second-order gradiometers of different baselines. The MCG signals were recorded using a measurement system with 61 magnetometers which measured the normal magnetic component to the chest surface. The distance between the chest surface and the bottom of the dewar was changed from 0 cm to 15 cm, and the MCGs were measured for each distance. By subtracting the other signals (distance = 1 to 15 cm) from the reference signal (distance =0 cm), we could simulate the first-order and the second-order gradiometer signals with various baselines. In addition, to evaluate the reproducibility of the simulation, we fabricated the wire wound first-order and second-order gradiometers which measured a normal magnetic component to the chest surface. The baselines of the first-order gradiometers were, respectively, 50 mm, 70 mm and 100 mm and the baseline of the second-order gradiometer was 50 mm. Using these gradiometers, we recorded the MCG signal and compared the SNR between the simulation and the measurement.

  • PDF

Acoustic Signal Processing for ADCP using Zoom FFT Method to increase Frequency Resolution (주파수 해상도 증가를 위해 Zoom FFT 기법을 사용한 ADCP 음향신호처리)

  • Han, Jin-Hyun;Shim, Tae-Bo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.229-234
    • /
    • 2010
  • This paper proposed the acoustic signal processing techniques, which are applicable even in the shallow river, and will enhance the frequency resolution of the ADCP (Acoustic Doppler Current profiler). ADCP is a device that measures the velocity of a moving fluid. ADCP, in general, can be operated at ~300 Khz of center frequency due to no depth limit in the sea. However, it can hardly be used due to water depth of 30cm or shallower during the dry season in the river. Therefore, existing signal processing methods are not suitable to use in the shallow river. We are proposing an alternative acoustic signal processing method using Zoom FFT. Simulation results show that errors are reduced ${\pm}62\;cm/s$ in theory, and ${\pm}93\;cm/s$ in the experiment. The existing algorithm could not estimate the current speed at the shallow river below 30 cm, but proposed algorithm estimated the current speed that was faster than 20 cm/s at the shallow river below 30 cm.

Design of Software GPS L2 Civil Signal Generator (ICCAS 2003)

  • Seo, Sam-Suk;Cho, Deuk-Jae;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2632-2635
    • /
    • 2003
  • This paper designs a software signal generator for the new GPS L2 civil signal. The CM/CL code and the message structure of L2CS described in GPS ICD PPIRN-200C-007 are used in designing the signal generator. The output of the GPS signal generator is designed as the sampled IF data with the sampling frequency 5.7MHz and stored in the binary data format. By analyzing both the spectrum characteristics of the output signal and the correlation properties of the CM/CL code, the validation of the designed GPS signal generator is shown. It should be mentioned that the modeling of the GPS satellite constellation and the error sources remains for implementing the software space segment of GPS.

  • PDF

Ultra-Fast L2-CL Code Acquisition for a Dual Band GPS Receiver

  • Kim, Binhee;Kong, Seung-Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.4
    • /
    • pp.151-160
    • /
    • 2015
  • GPS L2C signal is a recently added civil signal to L2 frequency and is constructed by time division multiplexing of civil moderate (L2-CM) and civil long (L2-CL) code signals. While the L2-CM code is 20 ms-periodic and modulates satellite navigation message, the L2-CL code is 1.5s-periodic with 767,250 chips long code sequence and carries no data. Therefore, the L2-CL code signal allows receivers to perform a very long coherent integration. However, due to the length of the L2-CL code, the acquisition of the L2-CL code signal may take too long or require too much hardware resources. In this paper, we propose a three-step ultra-fast L2-CL code acquisition (TSCLA) technique for dual band GPS receivers. In the proposed TSCLA technique, a dual band GPS receiver sequentially acquires the coarse/acquisition (C/A) code signal at L1 frequency, the L2-CM code signal, and the L2-CL code signal to minimize mean acquisition time (MAT). The theoretical performance analysis and numerous Monte Carlo simulations show the significant advantage of the proposed TSCLA technique over conventional techniques introduced in the literature.

Signal Intensity Changes according to Coil Position Changes in MRI using 6 Channel SENSE Cardiac Array Coils (6채널 SENSE Cardiac Array 코일을 이용한 검사 시 코일의 위치 변화에 따른 신호강도)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.699-706
    • /
    • 2018
  • In this study, we measured signal intensities according to array coil position changes to provide reference data of coil directions and the distances as it deters image quality unless the coils are aligned properly. The multi-purpose MRI phantom was placed in body array coils, and it was moved to the top, bottom, left, and right directions by 2 cm from the center to 10 cm. After obtaining images, signal intensities were measured and compared. The results of this study were as follows: Except for the upward direction, the signal intensities of the reference signal was not significantly different from that of the reference signal intensity within 2cm in both T1 and T2-weighted images. In conclusion, in clinical circumstances which various challenges exist to align the coils exactly on the same lines, array coils should be positioned at least within 2 cm from the center except for the upward direction, on the same line to prevent the image qualities are lowered.

Correction of Fluctuation Pressure by Tube System (튜브시스템에서 변동풍압의 보정)

  • You, Ki-Pyo;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.1 s.3
    • /
    • pp.67-73
    • /
    • 2002
  • Measurement of fluctuating pressure by tube system is carefully designed due to the organ-pipe resonance. It is necessary to correct the pressure before analysis. The three method for correction the distortion fluctuation pressure short tube length and the frequency response functions and insert a restrictor in the tube to increase the damping. The first method is useful when the tube length is short. In second method, the distorted signal through the tubing transformed into the frequency domain, dividing by transfer function and inverse fourier transforming back into the time domain gives the required pressure signal. In this paper three types of tubing which have different length of 100cm, 150cm, 200cm were experimented the distorted signal and correct the distortion signal

  • PDF