Measurements of Saturation Energy Denity and Small Signal Gain Coefficient Dependent on the Active Gas Pressure in XeCl Laser Amplifier

XeCl 레이저 증폭기의 활성기체 압력에 따른 포화 에너지 밀도와 소신호 이득계수 측정

  • 김규옥 (한국표준과학연구원 역학연구부 레이저그룹) ;
  • 김용평 (한국표준과학연구원 역학연구부 레이저그룹)
  • Published : 1994.12.01

Abstract

Dependence of saturation energy density and small signal gain coefficient on the active gas pressure in XeCl laser amplifier has been investigated. The saturation energy density was increased almost linearly as 1.3, 1.45, 2.0, and $2.3mJ/\textrm{cm}^2$ when the pressure of Xe and He were 30 and 2000 mb, and the pressure of HC] was varied as 34, 52, 73, and 92 mb. Whereas the small signal gain coefficient was measured to be 6.5, 7.5, 7.0, 7.0 %/cm, which shows that the small signal gain did not varies not so much.o much.

XeCl 레이저 증폭기의 포화 에너지 밀도와 소신호 이득계수를 활성기체의 압력을 변화시키면서 측정하였다. Xe이 30mb, He이 2000mb일 때, HCl이 34, 52, 73, 92으로 압력이 높아짐에 따라 포화 에너지 밀도는 1.3, 1.45, 2.0, $2.3mJ/\textrm{cm}^2$로 거의 선형적으로 증가하였지만 소신호 이득계수는 6.5, 7.5, 7.0, 7.0%/cm로 거의 변화하지 않았다.