• 제목/요약/키워드: CM Noise

검색결과 431건 처리시간 0.025초

전원선 전도잡음 분리기 설계에 관한 연구 (A Study on the Design of Conducted Noise Separator for Power Line Noise)

  • 권준혁;이응주
    • 한국전자파학회논문지
    • /
    • 제9권4호
    • /
    • pp.552-559
    • /
    • 1998
  • Conducted noise in power line contains both the common mode(CM) and differential mode(DM) noise. These two modes of noise are caused by different noise sources and paths. Therefore, CM/DM noise must be deal with individually in EMI filter. In this paper the technique to separate power line noise is presented, which can be used to measure both the CM and the DM noise from total generated noise. Also, noise-separator is designed and experimental results showed 30 dB above of separation performance in 10 kHz~10 MHz.

  • PDF

Balance Winding Scheme to Reduce Common-Mode Noise in Flyback Transformers

  • Fu, Kaining;Chen, Wei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.296-306
    • /
    • 2019
  • The flyback topology is being widely used in power adapters. The coupling capacitance between primary and secondary windings of a flyback transformer is the main path for common-mode (CM) noise conduction. A Y-cap is usually used to effectively suppress EMI noise. However, this results in problems in space, cost, and the danger of safety leakage current. In this paper, the CM noise behaviors due to the electric field coupling of the transformer windings in a flyback adapter with synchronous rectification are analyzed. Then a scheme with balance winding is proposed to reduce the CM noise with a transformer winding design that eliminates the Y-cap. The planar transformer has advantages in terms of its low profile, good heat dissipation and good stray parameter consistency. Based on the proposed scheme, with the help of a full-wave simulation tool, the key parameter influences of the transformer PCB winding design on CM noise are further analyzed. Finally, a PCB transformer for an 18W adapter is designed and tested to verify the effectiveness of the balance winding scheme.

급수압에 따른 대변기 설비소음에 관한 연구 (A study on the Plumbing system noise of closet bowl by water supply pressure)

  • 김항;최은석;고광필;기노갑;이태강;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.11-16
    • /
    • 2006
  • It appraises that use an indoor noise standard, a NC value which is a noise appraisal, a dB(A) value, a N value in foreign country because it doesn't yet ready an appraisal standard in domestic. Also, It appraises that the supply and drainage noise which could change water supply pressure, $4kg/cm^2,\;3kg/cm^2,\;2kg/cm^2,\;1.5kg/cm^2,\;1kg/cm^2$, bring about a noise and inquires how does noise level indicates according to each instruments. In case of a water supply pressure standard, $3kg/cm^2$, a C-605is $3{\sim}5dB(A)$ lower than another instruments in directly overhead stories. It appears that all of them is similar to level in directly under level except c-407(2)Analyzed the NC value, c-605is the lowest level, NC-50, of a water supply pressure, $4.0kg/cm^2$, c-407 is the highest level, NC-55.(3) In case of N value, which is one of water supply methods in Japan, it is the lowest level, N-55, of a water supply pressure, $4.0kg/cm^2$ same as NC value and C-407is the highest level, N-60.(4) In case of water supply that is likely to noise level, It appears 6dB(A) level gap each instruments, and C-605 is the lowest level, 63.9dB(A).

  • PDF

선박소음에 관한 연구 -방음실에 의한 소음제어효과실험- (THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms-)

  • 박중희
    • 한국수산과학회지
    • /
    • 제9권3호
    • /
    • pp.215-221
    • /
    • 1976
  • 1976년 6월 10일부터 동년 8월 30일까지 본학 해양과학 연구소 하층 실험실에서 실험하였고 1975년 6월 7일에서 동년 8월 11일까지 약 2개월 동안에 풍양호, 척양호, 관악산호 등의 선박소음을 녹음한 테프로서 재생방음한 것을 음원으로 이용하였다. 이때 소음제어의 효과를 찾기 위해 A,B,C,D형의 실험용 직육면체인 방음실을 제작하여 실험실내에 배치하고 기관실소음과 발진기에 스피커를 연결해서 방음된 음압이 각방음제어실에 투과되는 음압 100분률과 또 각 방음제어실내에서 같은 조건으로 방음되는 경우에 자재와 형상이 다른 방음실내부 구조물에 따른 흡음효과를 조사 비교한 결과를 요약하면 다음과 같다. 1. 소음투과율은 실험실 외부음압이 60dB 일때 A형은 $69.7\%$였고 계속 10dB 증가함에 따라 $3.3\%$씩 증가하였고 D형에서는 $53.9\%$인 것이 10dB 증가함에 따라 $4.5\%$씩 증가했다. 2. 실험실인 외부음압이 100dB일 때 A,B,C,D형의 음압투과율은 81.6, 78.9, 75.3, $71.0\%$의 순으로 D형의 투과율이 낮아서 방음실로서는 D형이 가장 좋았다. 3. 대화에 지장이 없는 소음압은 75dB 이하이므로 A,B형을 제외하고 C,D형은 선박소음 제어실로서 유효했다. 4. 방음제어실내부 구조에 따른 흡음효과를 A,D형에서 비교하면 A형은 발진음일 때 거리 20cm에서 82dB로 가장 높고 80cm에서 76dB로 가장 낮았으며 100cm에서 77dB였고 140cm에서 78dB 정도 다시 증가해 반사음 현상이 일어났다. D형은 발진음일 때 거리 20cm에서 A와 같이 82dB였는데 80cm에서 72.5dB, 100cm에서 73dB, 140cm서에는 67dB로 A보다 12dB가 낮았다. 선박소음도 거리 20cm에서 A형은 77.5dB, D형은 77dB였는데 140cm에서는 A형이 74dB, D형이 63dB로 11dB의 차이로 D형이 낮아 역시 흡음효과가 A형 보다 D형이 좋았고 완벽한 무향실로서 반사음의 영향은 찾아 볼 수 없었다. 5. 매우 낮은 발진음일 때 흡음관계를 1000Hz를 기준삼아 보면 거리 20cm에서 C형은 44.7dB, D형은 45.4dB로 C형이 0.3dB로 악간 낮았으나 140cm에서 C,D형 모두가 44.3dB로서 같았다. 값싼 자재로서도 C형이 가장 흡음효과가 좋았다.

  • PDF

직립식 산란계사 내의 소음 진동 발생 현황 조사연구 (Study on the Characteristics of Noise/Vibration in the Upright Laying Hen House)

  • 이승주;장동일;장홍희
    • 한국축산시설환경학회지
    • /
    • 제12권1호
    • /
    • pp.21-28
    • /
    • 2006
  • 국민의 소득 증대로 인해 육류 및 계란의 소비량이 점차적으로 증가하는 추세에 있다. 이로 인해 산란계사의 규모가 대형화됨에 따라 기계화되었고, 이 연구에서는 고단 직립식 케이지를 사용하는 무창계사에서 기계시설이 작동 시 발생되는 소음 및 진동이 산란계의 생산성에 미치는 영향을 구명하고자 산란계사내의 소음/진동 수준을 측정 분석하였다. 전국의 13개 산란계 농장을 대상으로 하여 평상시 및 기계시설(사료급이기, 사료분배기, 집란시스템, 환기장치, 계분벨트)의 작동시에 발생되는 소음/진동을 측정하였다. (1) 평상시 소음 최대 82dB, 진동 최대 0.2072 cm/s, (2) 사료급이기 작동 시 소음 최대 90dB, 최대 진동 2.8560cm/s, (3) 사료분배기 작동시 소음 최대 90dB, 최대 진동 2.022cm/s, (4) 집란시스템 작동 시 최대 소음 87dB, 최대 진동 0.1865cm/s, (5) 환기장치 작동 시 케이지에 미치는 최대 88dB, 계사 후면 벽면에 미치는 최대 진동 2.5364cm/s, (6) 계분벨트 작동 시 최대 소음 88dB, 최대 진동 0.2387cm/s 이었다. 따라서 산란계에게 직접적이고 가장 크게 영향을 미치는 장치는 급이 시스템이였다. 이 때의 소음은 최대 90dB로 가장 높게 발생하였으며, 진동은 최대 2.8560 cm/s 발생하였다.

  • PDF

Adaptive group of ink drop spread: a computer code to unfold neutron noise sources in reactor cores

  • Hosseini, Seyed Abolfazl;Afrakoti, Iman Esmaili Paeen
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1369-1378
    • /
    • 2017
  • The present paper reports the development of a computational code based on the Adaptive Group of Ink Drop Spread (AGIDS) for reconstruction of the neutron noise sources in reactor cores. AGIDS algorithm was developed as a fuzzy inference system based on the active learning method. The main idea of the active learning method is to break a multiple input-single output system into a single input-single output system. This leads to the ability to simulate a large system with high accuracy. In the present study, vibrating absorber-type neutron noise source in an International Atomic Energy Agency-two dimensional reactor core is considered in neutron noise calculation. The neutron noise distribution in the detectors was calculated using the Galerkin finite element method. Linear approximation of the shape function in each triangle element was used in the Galerkin finite element method. Both the real and imaginary parts of the calculated neutron distribution of the detectors were considered input data in the developed computational code based on AGIDS. The output of the computational code is the strength, frequency, and position (X and Y coordinates) of the neutron noise sources. The calculated fraction of variance unexplained error for output parameters including strength, frequency, and X and Y coordinates of the considered neutron noise sources were $0.002682{\sharp}/cm^3s$, 0.002682 Hz, and 0.004254 cm and 0.006140 cm, respectively.

360° 전방위 화각을 가진 Dash Camera의 EMI 대응을 위한 Board 개발 (Development of Board for EMI on Dash Camera with 360° Omnidirectional Angle)

  • 이희열;이선구;이승호
    • 전기전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.248-251
    • /
    • 2017
  • 본 논문에서는 $360^{\circ}$ 전방위 화각을 가진 Dash Camera의 EMI 대응을 위한 보드 설계를 제안한다. 제안된 보드는 DM 및 CM 입력 노이즈 감소회로를 설계하고 능동 EMI 필터 결합회로를 적용하여 개발한다. DM 및 CM 입력 노이즈 감소회로 설계부분에서는 기생적 커패시턴스(CP)을 통해 입력 신호로 커플링된 DM 잡음을 얻기 위한 차동연산 증폭기 회로를 사용한다. 능동 EMI 필터 결합회로를 적용하여 설계하는 부분에서는 회로의 간략화를 위하여 EMI 소스의 노이즈를 분리하여 보상해 주기 위하여 노이즈 분리기를 설치하여 CM과 DM 능동필터를 동시에 보상한다. 제안된 EMI 대응을 위한 보드의 성능을 평가하기 위하여 공인 인정기관에서 실험한 결과, 각각의 주파수 대역에 따른 전자파 인증규격이 만족됨을 확인하였다.

새로운 능동EMI필터의 결합회로에 관한 연구 (A Study on the Combining Circuit of New Active EMI Filter)

  • 최민환;신동석;이동호;박종연
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.78-89
    • /
    • 2015
  • Conventional EMI filters have tried to use an active EMI filter as a series by the series connection of two EMI filters for CM and DM noise. However, the proposed filter is formed into one circuit by using the active EMI filter which is able to filter CM and DM noise components together. As a result, the active EMI filter showed the outstanding quality in mass and volume under 50% and electric characteristics have been compared to the passive EMI filter in approximately 150kHz~10MHz. Furthermore, the proposed circuit has simple circuit components by comparing with the series EMI filters, and electrical characteristics are similar. The noise have been attenuated to maximum 20dBuV.

모드 분리 기법을 이용한 스위치 컨버터의 전도잡음 분석 및 대책에 관한 연구 (Study on the analysis and suppression of conducted noise from switching converter by the mode separation technique)

  • 김진성;권준혁;김양모
    • 전자공학회논문지S
    • /
    • 제35S권4호
    • /
    • pp.128-138
    • /
    • 1998
  • This paper describes a principle of the conducted noise separator which can separate the conducted noise to the common mode and differential mode(normal mode), and presents the transfer characteristics of the separator designed and manufactured. We separated the conducted noise generated from switched mode converter to the CM and DM conducted noise, and also analyzed the source and path of conducted noise in the converter by the conducted noise separator. Since we could easily get the characteristics of the CM and DM conducted noise by the separator, we could efficiently determine the contermeasures for the reduction of the conducted noise and establish the foundation of the systematic procedure for the design of low pass filter.

  • PDF

소음.진동에 따른 참전복(Haliotis discus hannai)의 전중량 및 먹이섭식량 변화 (The Change of Total Weight and Food Consumption of Abalone, Haliotis discus hannai under a Vibration and Noise)

  • 정형택;김영식;최상덕
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.581-589
    • /
    • 2004
  • This paper describes the amount of food consumption and the change of total weight of abalone under a vibration with noise that can be occurred due to piling work. This experiment was conducted in the aquarium in Yosu National University. In normal situation the juvenile stage shell's(total length is 1~1.5cm) amount of food consumption was 0.81g, the middle stage shell(total length is 3~3.5cm) was 13.61g, and the adult stage shell (Total length is 7~7.5cm) was 43.l9g per 5 organisms in 24 hours, while the experimental group was observed low numerical value compared normal groups. The abalones' food consumption and total weight in both groups, the intermittent and continuance impact with noise and vibration, was reduced during this experiment. The abalones' food consumption and total weight in the experimental groups without vibration were recorded slightly high numerical value than the experimental groups with noise and vibration. Based on this experimental data we could conjecture the noise and vibration are harmful factors to bring up a physiological stress to abalones. Especially, the vibration impact by piling works could produce a considerably unfavorable effect to the abalones than noise impact.