• 제목/요약/키워드: CIP System

검색결과 74건 처리시간 0.025초

한국형 CIP 제도의 도입방안에 관한 연구 (Designing Korean Cataloging in Publication System)

  • 오동근;여지숙
    • 한국문헌정보학회지
    • /
    • 제35권2호
    • /
    • pp.59-74
    • /
    • 2001
  • 이 연구에서는 한국형 CIP 제도의 도입과 관련하여, 주요국을 중심으로 CIP의 등장배경과 역사, 현황, CIP의 도입필요성과 효과, 도입방안을 종합적으로 고찰하였다. 아울러 한국형 CIP의 기본적인 개념과 모델을 제시하고, CIP의 도입시에 고려해야 할 주요 사항들을 정책 및 예산상의 문제와 업무 및 기술상의 문제로 나누어 분석하였다.

  • PDF

CIP 도체 압축기술에 따른 구리도체 저항변화 (Variation of Electric Resistance under the CIP process of Strended Copper Conductors)

  • 정승;양훈철;최아름
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1428-1429
    • /
    • 2011
  • This paper variation of stranded cable conductor with CIP(Cold Isostatic Press) technology. Conductor as cable material takes majority costs. Thus many experiments have been done on conductor compaction. The core technology is to maintain the resistance of circular stranded conductor after compaction process, while reducing the weight of conductor diameter, but by increasing filling factor. Testing by varying the compaction ratio using 300SQ conductor, conductor after CIP process shows lower resistance rather than conductor before CIP process.

  • PDF

CIP-CSL2법에 의한 다상유동 경계포획 시뮬레이션 (Interface-tracking simulation of multi-phase flow using CIP-CSL2 scheme)

  • 임효남
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.25-30
    • /
    • 2011
  • In this study, it is performed numerical simulation on multi-phase flow by means of CIP-CSI2 scheme. It is applied In a two-phase free surface flow problem at a high density ratio equivalent to that of an air-water system, for examining the computational capability. The method that is being developed and improved is a CIP(Constrained Interpolation Profile) and CSL2(Conservative Semi-Lagrangian) based Cartesian Grid Method.

  • PDF

직매형 앵커기초의 전단설계를 위한 ACI 349 Code의 평가 (An Evaluation of ACI 349 Code for Shear Design of CIP Anchor)

  • 장정범;황경민;서용표
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.464-470
    • /
    • 2005
  • The numerical analysis is carried out to identify the influence of design factors to shear capacity of cast-in-place (CIP) anchor in ACI 349 Code that is available for the design of fastening system at Nuclear Power Plant (NPP) in this study. The MASA program is used to develop the numerical analysis model and the developed numerical analysis model is verified on a basis of the various test data of CIP anchor. Both $l/d_o$ and $c_1/l$ we considered as design factors. As a result, the variation of $l/d_o$ has no influence on the shear capacity of CIP anchor but $c_1/l$ has a large influence on the shear capacity of CIP anchor, Therefore, it is proved that ACI 349 Code may give a non-conservative results compared with real shear capacity of CIP anchor according to $c_1/l$.

  • PDF

CIP 방법을 사용한 해석법 (A NUMERICAL ANALYSIS USING CIP METHOD)

  • 이정희;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.211-217
    • /
    • 2009
  • The numerical program has been developed for the purpose of the complicate geometries application using CIP method. The non-staggered, non-orthogonal, and unstructured grid system can be also used for the various geometries in the program. For validating CIP solver, the lid-driven cavity flow and solitary wave propagation flow are carried out. Test results show a good agreement with the verified results. The dynamic solver was used for the behavior of moving body. Interface process between the two solvers is introduced. The research was performed on the flow problem around torpedo and log and the flow problem in a tank in order to analyze the three phase flow problem Although the comparison to the verified results was not quantitatively performed, the trend of the results was reasonable.

  • PDF

CIP 기반의 지능형 전동기 제어 시스템 (Intelligent Motor Control System Based on CIP)

  • 김온;최성진
    • 한국전자통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.307-312
    • /
    • 2020
  • 본 논문에서는 산업 현장에서 효율적인 전동기 제어를 수행하도록 전동기 보호 릴레이, 스마트 회로 차단기 및 가변 속도 드라이브 등의 스마트 전동기 장치를 하나의 통합 모듈로 대체한 지능형 전동기 제어 시스템을 제안하였다. 제안된 지능형 전동기 제어 시스템은 CIP(Common Industrial Protocol)기반의 네트워크를 통하여 지능형 전동기 제어 시스템에 연결된 각각의 전동기 또는 부하에 대한 중요 데이터를 쉽게 모니터링할 수 있으므로 언제나 정확한 프로세스 제어가 가능하고, 고장 정보 및 기록에 실시간으로 액세스하여 진단을 간소화하며, 장비 가동 중단 시간을 최소화할 수 있다.

CIP법을 이용한 구 좌표계에서의 천수 방정식 해석 (NUMERICAL ANALYSIS FOR THE SHALLOW WATER EQUATIONS ON THE SPHERE BY CIP METHOD)

  • 윤성영;김수연;김현철
    • 한국전산유체공학회지
    • /
    • 제10권2호
    • /
    • pp.7-14
    • /
    • 2005
  • In this study, the shallow water equations on the sphere is simulated by the proposed method which has high spatial resolution and is based on the CIP(Cubic Interpolated Pseudoparticle) method. The governing equations are approximated on the longitude-latitudinal coordinate system. To avoid the problems resulting from the convergence of the meridians toward high-latitude and singularities on the poles, the semi-Lagrangian and finite volume method are employed. in addition, the CIP method is employed to solve the advection equations and is extended to apply on the equations in the polar coordinate system. The mathematical formulation and numerical results are also described. To verify of the efficiency, accuracy and capability of proposed algorithm, the standard test cases proposed bv Williamson et. al are simulated and the results are compared with other results. As a result, it is found that the present scheme gives a good properties in preserving shapes of solution and settles the pole problems in solving the shallow water equations on the sphere.

목장형 유가공장의 미생물 분석 및 저감기술 적용 평가 (Evaluation of Microbial Analysis and Application of Reduction Technology in a Dairy Factory)

  • 김종희;이은선;김부민;함준상;오미화
    • Journal of Dairy Science and Biotechnology
    • /
    • 제41권4호
    • /
    • pp.203-210
    • /
    • 2023
  • Bacterial contamination negatively affects the quality, functionality, and safety of dairy products. Adherent populations of bacteria, referred to as biofilms, grow on the surfaces of dairy processing equipment and are the primary cause of dairy contamination. In addition, microorganisms present in the farm environment and dairy factory can contaminate the Clear-In-Place (CIP) line through raw milk transport pipes; therefore, exhaustive management is required. In dairy manufacturing facilities, biofilm formation is controlled using CIP systems that primarily require sodium hydroxide and nitric acid. However, the leakage or incomplete removal of these potently active compounds can be harmful to humans. In the present study, we compared the eradication of Escherichia coli and other bacteria using commercially available combinations of sodium hypochlorite (NaClO) and citric acid, which are recognized by the Korean Ministry of Food and Drug Safety (MFDS) as food disinfectants. When considered in the CIP system of the field manufacturing process, E. coli was not detected (compared to detection before treatment), and other bacteria were detected at 0-32 culture-forming units (CFU)/cm2. The residual amount of chlorine ions after CIP treatment was similar to that in tap water, and there was no significant difference in the overall components of the fermented dairy products. Therefore, the NaClO/citric acid CIP system can be safely applied in dairy manufacturing processes.

STUDY OF NEW CAST-IN-PLACE MORTAR WALL FOR HOUSE CONSTRUCTION COMPARED TO BRICK AND MORTAR-BLOCK SYSTEM (A SIMULATION IN DIFFERENT AREAS)

  • Arief Setiawan Budi Nugroho;Shin-ei Takano
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.196-202
    • /
    • 2009
  • Study from Yogyakarta earthquake reconstruction program, cast-in-place wall using fix-size formwork system (Old-CIP) has offered a good alternative for house construction. A simulation has also confirmed that this system using mortar as the main material can provide cheapest cost and lowest total man power compared to conventional wall construction technique: brick or mortar-block wall. This paper presents the new wall construction technique: full size cast-in-place wall (New-CIP). The detail of how this new technique implemented is described. In addition, considering that material and labor cost in one area is different to others, cost analysis for different resources prices and wages of three cities are taken into a simulation. The analysis is aimed to distinguish the implementation feasibility of New-CIP system compared to the four common wall systems. Finally, its implementation resistance is also discussed.

  • PDF

Soroban grid 기반 CIP법을 이용한 자유표면 유동해석 (FREE SURFACE FLOW ANALYSIS BY SOROBAN GRID BASED CIP MEHTOD)

  • 임효남
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.326-334
    • /
    • 2010
  • In this study, we provide a comprehensive review of the CIP(Constrained Interpolation Pro file/Cubic Interpolated Propagation) method with a pressure-based algorithm that is known as a general numerical solver for soled liquid, gas and plasmas. And also we introduce a body-fitted grid system(Soroban grid) for computation of strongly nonlinear marine hydrodynamic problems such as slamming water on deck, wave impact by green water. This grid system can keep the third-order accuracy in time and space with the help of the CIP method. The grid system consists of the straight lines and grid points. In the 2-dimensional grid case, each grid points moving in these lines like abacus - Soroban in Japanese. The length of each line can be different and the number of grid points in each line can be different. Mesh generation and searching of upstream departure point are very simple and possible to mesh-free treatment. To optimize computation of free-surface and multi-fluid flows, We adopt the C-CUP method. In most of the earlier computations, the C-CUP method was used with a staggered-grid approach. Here, because of the mesh free nature of the Soroban grid, we use the C-CUP method with a collocated-grid approach.

  • PDF