• Title/Summary/Keyword: CI Performance

Search Result 627, Processing Time 0.024 seconds

Development of Measuring Technique for Milk Composition by Using Visible-Near Infrared Spectroscopy (가시광선-근적외선 분광법을 이용한 유성분 측정 기술 개발)

  • Choi, Chang-Hyun;Yun, Hyun-Woong;Kim, Yong-Joo
    • Food Science and Preservation
    • /
    • v.19 no.1
    • /
    • pp.95-103
    • /
    • 2012
  • The objective of this study was to develop models for the predict of the milk properties (fat, protein, SNF, lactose, MUN) of unhomogenized milk using the visible and near-infrared (NIR) spectroscopic technique. A total of 180 milk samples were collected from dairy farms. To determine optimal measurement temperature, the temperatures of the milk samples were kept at three levels ($5^{\circ}C$, $20^{\circ}C$, and $40^{\circ}C$). A spectrophotometer was used to measure the reflectance spectra of the milk samples. Multilinear-regression (MLR) models with stepwise method were developed for the selection of the optimal wavelength. The preprocessing methods were used to minimize the spectroscopic noise, and the partial-least-square (PLS) models were developed to prediction of the milk properties of the unhomogenized milk. The PLS results showed that there was a good correlation between the predicted and measured milk properties of the samples at $40^{\circ}C$ and at 400~2,500 nm. The optimal-wavelength range of fat and protein were 1,600~1,800 nm, and normalization improved the prediction performance. The SNF and lactose were optimized at 1,600~1,900 nm, and the MUN at 600~800 nm. The best preprocessing method for SNF, lactose, and MUN turned out to be smoothing, MSC, and second derivative. The Correlation coefficients between the predicted and measured fat, protein, SNF, lactose, and MUN were 0.98, 0.90, 0.82, 0.75, and 0.61, respectively. The study results indicate that the models can be used to assess milk quality.

Favorable Outcome in Elderly Asian Patients with Metastatic Renal Cell Carcinoma Treated with Everolimus: The Osaka Urologic Oncology Group

  • Inamoto, Teruo;Azuma, Haruhito;Nonomura, Norio;Nakatani, Tatsuya;Matsuda, Tadashi;Nozawa, Masahiro;Ueda, Takeshi;Kinoshita, Hidefumi;Nishimura, Kazuo;Kanayama, Hiro-Omi;Miki, Tsuneharu;Tomita, Yoshihiko;Yoshioka, Toshiaki;Tsujihata, Masao;Uemura, Hirotsugu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1811-1815
    • /
    • 2014
  • Background: In clinical trials with no upper age limit, the proportion of older patients is usually small, probably reflecting the more conservative approach adopted by clinicians when treating the elderly. An exploratory analysis of elderly patients in the RECORD-1 Trial showed that patients ${\geq}$ 65 y.o. had superior median PFS than overall RECORD-1 population (5.4 months and 4.9 months, respectively). We investigated the efficacy, relative benefit and safety of Everolimus (EVE) as sequential therapy after failure of VEGFr-TKI therapy for older patients with metastatic renal cell cancer (mRCC), in daily practice. Materials and Methods: 172 consecutive IRB approved patients with mRCC (median age 65, M:F 135/37, 78% clear cell) who received salvage EVE at 39 tertiary institutions between October 2009 and August 2011 were included in this analysis. Some 31% had progressed on sunitinib, 22% on sorafenib, 1% on axitinib, 41% on sequential therapy, and 5% had received other therapy. Patients with brain metastases were not included and 95% of the patients had a ECOG (Eastern Cooperative Oncology Group) performance status (PS) of 0 or 1. Previous radiotherapy was an exclusion criterion, but prior chemotherapy was permitted. Adequate organ function and hematologic parameters were mandatory. EVE administration was approved by the institutional review board at each participating institution and signed informed consent was obtained from all patients. Results: Median time of the whole cohort to last follow-up was 3.5 months (range 0.4-15.2 months). Forty four percent were continuing to take EVE at last followup. There were 86 (50%) patients ${\geq}$ 65 y.o. and 86 (50%) <65 y.o. The percentage of patients who showed PR/SD was higher in the older group than in the younger one (5.9%/61.2% vs 1.2%/46.5%, respectively). Median survival of older patients was also significantly longer (3.5 +/- 0.31 vs 3.1 +/- 0.34, hazard ratio=0.45, CI; 0.255-0.802). Analysis using Cox regression model adjusted for gender, PS, number of metastases, site of metastases, histology, smoking history and age detected an association between age and PFS (p=0.011). The frequency of adverse events in elderly patients treated with EVE was no greater than that in younger patients, although such toxicity may have had a greater impact on their quality of life. Conclusions: Older patients should not generally be excluded from accepted therapies (mTOR inhibitors after failure of VEGFr-TKI therapy) for mRCC.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Nutrition of Calcium and Phosphorus in Poultry Diets (닭에 대한 칼슘과 인의 영양)

  • 한인규;오상집
    • Korean Journal of Poultry Science
    • /
    • v.8 no.2
    • /
    • pp.55-68
    • /
    • 1981
  • Calcium and phosphorus are not only indispensable for the bone formation and body fluids equilibrium but also are major components of egg shell. It is nutritionally important, therefore, to investigate the metabolism of calcium and phosphorus and to search for optimum requirement of calcium and phosphorus and the availability of various sources of calcium an4 phosphorus by poultry. An attempt was made to review the nutrition of calcium and phosphorus in poultry diets. 1, Calcium and phosphorus have great interrelationship with vitamin D in their metabolisms. 2. Most of the plant-origin phosphorus are existing in phytic form and it leads to low availability when used in poultry rations, although calcium and phosphorus present in animal-origin or mineral supplements are highly available in general. 3. Calcium and phosphorus requirement from existing information indicated that 1.0% calcium and 0.7% phosphorus for broiler and egg-type chicks, and 3.5% calcium and 0.4% phosphorus for laying hen. 4. It has been recommended that calcium and phosphorus level should be increased when the feed intake was decreased or when the egg Production rate was higher or when the hens are old. 5. Mono-, ci-, tri-, calcium phosphate, calcium carbonate, bone meal, limestone and oyster shell u the most readily available among various sources of calcium phosphorus supplements. Soft rock phosphate, deflourinated phosphate and gypsum are somewhat inferior to the previous ones in bioavailability. 6. The effect of particle size of calcium supplements on egg shell quality and egg production rate is not yet clearly defined but recent works showed that oyster shell is more available when it was coarse and limestone is more available when it was fine in panicle. size. 7. Present data indicated that mixed feeding of oyster shell and limestone is superior to the single feeding of each on laying performance. 8. Significant interaction between phosphorus and sodium was observed, that is, excessive sodium decreased egg production in layer and body weight growth in broiler in the low phosphorus diets but increased them in the high phosphorus diets.

  • PDF

Robust Eye Localization using Multi-Scale Gabor Feature Vectors (다중 해상도 가버 특징 벡터를 이용한 강인한 눈 검출)

  • Kim, Sang-Hoon;Jung, Sou-Hwan;Cho, Seong-Won;Chung, Sun-Tae
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.1
    • /
    • pp.25-36
    • /
    • 2008
  • Eye localization means localization of the center of the pupils, and is necessary for face recognition and related applications. Most of eye localization methods reported so far still need to be improved about robustness as well as precision for successful applications. In this paper, we propose a robust eye localization method using multi-scale Gabor feature vectors without big computational burden. The eye localization method using Gabor feature vectors is already employed in fuck as EBGM, but the method employed in EBGM is known not to be robust with respect to initial values, illumination, and pose, and may need extensive search range for achieving the required performance, which may cause big computational burden. The proposed method utilizes multi-scale approach. The proposed method first tries to localize eyes in the lower resolution face image by utilizing Gabor Jet similarity between Gabor feature vector at an estimated initial eye coordinates and the Gabor feature vectors in the eye model of the corresponding scale. Then the method localizes eyes in the next scale resolution face image in the same way but with initial eye points estimated from the eye coordinates localized in the lower resolution images. After repeating this process in the same way recursively, the proposed method funally localizes eyes in the original resolution face image. Also, the proposed method provides an effective illumination normalization to make the proposed multi-scale approach more robust to illumination, and additionally applies the illumination normalization technique in the preprocessing stage of the multi-scale approach so that the proposed method enhances the eye detection success rate. Experiment results verify that the proposed eye localization method improves the precision rate without causing big computational overhead compared to other eye localization methods reported in the previous researches and is robust to the variation of post: and illumination.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Analysis of Prognostic Factors Related to Survival Time for Patients with Small Cell Lung Cancer (소세포폐암 환자의 생존기간에 관련된 인자 분석)

  • Kim, Hee-Kyoo;Yook, Dong-Seung;Shin, Ho-Sik;Kim, Eun-Seok;Lim, Hyun-Jeung;Lim, Tae-Kwan;Ok, Chul-Ho;Cho, Hyun-Myung;Jung, Maan-Hong;Jang, Tae-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.1
    • /
    • pp.57-70
    • /
    • 2003
  • Background : Small cell lung cancer represents approximately 20% of all carcinomas of the lung, and is recognized as having a poor long term outcome compared to non-small cell lung cancer. Therefore, this study investigated the prognostic factors in small cell lung cancer patients in order to improved the survival rate by using the proper therapeutic methods. Material and method : The clinical data from 394 patients who diagnosed with small cell lung cancer and treated from 1993 to 2001 at the Kosin University Gospel Hospital, were analyzed. Result : There were 314 male patients (79.7%), and 80 female patients (20.3%). The number of those with limited disease was 177 (44.9%), and the number of those with extensive disease was 217 (55.1%). Overall, 366 out of 394 enrolled patients had died. The median survival time was 215 days (95% CI : 192-237days). The disease stage, Karnofsky performance state, 5% body weight loss for the recent 3 months, chemotherapy regimens, and the additive chest radiotherapy were identified as being statistically significant factors for the survival time. The median survival times of the supportive care group, one anticancer therapy, and two or more treatment groups were 17 days, 211 days, and 419 day, respectively (p<0.001). These data emphasize the importance of anticancer treatment to improve survival time for patients. The group of concurrent chemoradiotherapy (30 patients) showed significantly longer survival time than the group given sequential chemoradiotherapy (55 patients) (528 days versus 373 days, p=0.0237). The favorable prognostic factors of laboratory study were groups of leukocyte =8,000/mm3, ALP=200 U/L, LDH=450 IU/L, NSE=15 ng/mL, s-GOT=40 IU/L. In extensive disease, there was no difference according to the number of metastatic site. However, the median survival time of patients with ipsilateral pleural effusion had longer than patients having other metastatic sites. According to the survey periods, three groups were divided into 1993-1995, 1996-1998, and 1999-2001. The median survival time was significantly prolonged after 1999 in comparison to previous groups (177 days, 194 days, 289 days, p=0.001, 0.002, respectively). Conclusion: Disease stage and 5% body weight loss for recent 3 months at diagnostic state were significant prognostic factors. In addition, the performance status, serum ALP, LDH, NSE, CEA levels also appear to be prognostic factors. The survival time of those patients with small cell lung cancer has been prologned in recent years. It was suggested that the used of the EP (etoposied and cisplatin) chemotherapy method and concurrent chemoradiotherapy for patients with a limited stage contributed to the improved survival time.