• Title/Summary/Keyword: CFL

Search Result 85, Processing Time 0.028 seconds

Numerical Study on Turbulent Flow Inside a Channel with an Extended Chamber (난류 경계층에 놓인 공동 내부유동에 관한 수치해석적 연구)

  • Lee, Young-Tae;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.925-931
    • /
    • 2010
  • The paper describes a Large Eddy Simulation (LES) study of turbulent flow around a cavity. A series of three-dimensional cavities placed in a turbulent boundary layer are simulated at a Reynolds number of $1.0{\times}10^5$ by considering U and h, which represent the velocity at the top and the depth of the cavity, respectively. In order to obtain the appropriate solution for the filtered Navier-Stokes equation for incompressible flow, the computational mesh forms dense close to the wall of the cavity but relatively coarse away from the wall; this helps reduce computation cost and ensure rapid convergence. The Boussinesq hypothesis is employed in the subgrid-scale turbulence model. In order to determine the subgrid-scale turbulent viscosity, the Smagorinsky-Lilly SGS model is applied and the CFL number for time marching is set as 1.0. The results show the flow variations inside cavities of different sizes and shapes.

Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression (발목관절 VISTA 자기공명영상에서 정량평가와 인대의 Traceability: 지방억제 대비 지방억제기법)

  • Cho, Kyung Eun;Yoon, Choon-Sik;Song, Ho-Taek;Lee, Young Han;Lim, Daekeon;Suh, Jin-Suck;Kim, Sungjun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.110-122
    • /
    • 2013
  • Purpose : To compare the image quality and ligament traceability in ankle images obtained using Volume Isotropic Turbo Spin Echo Acquisition (VISTA) MRI with and without fat suppression. Materials and Methods: The signal-to-noise ratios (SNRs) in images from a phantom and from the ankle of a volunteer were compared. Ten ankles from 10 non-symptomatic volunteers were imaged for comparisons of contrast ratio (CR) and ligament traceability. All examinations were performed using VISTA sequences with and without fat suppression on a 3T MRI scanner. The SNRs were obtained from images with subjects and without subjects (noise-only). Contrast ratios from images of the 10 ankles were acquired between fluid and tendon (F-T), F-cartilage (C), F-ligament (L), fat (f)-T, f-C and f-L. Two musculoskeletal radiologists independently scored the traceability of 7 ligaments, in sagittal, axial and coronal images respectively, based on a 4-point scale (1 as not traceable through 4 as clearly traceable). The Wilcoxon signed-rank test was used to compare the CR. Fisher's exact test and Pearson's chi-squared test were used to compare the ligament traceability. Results: The SNRs did not differ significantly between the two sequences except in bone marrow. VISTA SPAIR showed the higher CR only in F-T (p = 0.04), whereas VISTA showed higher CR in f-T (p = 0.005), f-C (p = 0.005) and f-L (p = 0.005). The calcaneofibular ligament traceability with VISTA was superior to that obtained with VISTA SPAIR (p < 0.05) in all planes. Conclusion: VISTA showed significant superiority to VISTA SPAIR in tracing CFL due to the superior CR between fat and ligament.

Fermented Crataegi fructus Vinegar Improves Lipid Metabolism in Rats Fed High Fat Diet (산사발효초가 고지방식이를 급여한 흰쥐의 지질대사에 미치는 영향)

  • Chon, Jeong-Woo;Park, Jin-Kyung;Lee, Mi-Ae;Jeong, Mi-Ran;Han, Jong-Hyun;Park, Yoo-Kyoung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.8
    • /
    • pp.1024-1031
    • /
    • 2009
  • Crataegi fructus has been used as an oriental medicine and a folk remedy for the treatment of scurvy, constipation and stomach ailment. This study was aimed to investigate the effect of fermented Crataegi fructus vinegar (FCV) on the improvement of lipid metabolism in rats fed high fat diet (40% kcal% fat, fat source; beef tallow). Sprague-Dawley rats (n=32) were randomly divided into four groups [normal diet (ND), high fat diet (HD), and high fat diet supplemented with low (CFL; 1.5% wt/wt) and high (CFH; 3.0% wt/wt) doses of fermented Crataegi fructus vinegar] and were fed experimental diets for 6 weeks. At the end of the experiment, the body weight in high fat diet groups was higher than that of normal diet group, while the body weights of CFL and CFH group were significantly reduced by 7.2% and 10.0%, respectively, as compared with that of HD group. Moreover, liver and kidney weights in CFL and CFH group were significantly lower than that of HD group (p<0.05). The levels of serum triglyceride, total cholesterol, LDL-C, atherogenic index and hepatic triglyceride, total cholesterol in CFH group were significantly decreased as compared with HD group whereas it increased the serum level of HDL-C than HD group (p<0.05). CFL and CFH groups showed significantly decreased AST, ALT and ALP of serum as compared with HD group. Excretions of fecal saturated fatty acid in CFH group was significantly increased compared with ND and HD groups. These results imply that fermented Crataegi fructus vinegar can be used as possible food resources and functional food materials.

Comparative Analysis on Heat Radiation of LED Luminaires (LED 등기구의 발열량 비교분석)

  • Kim, Dong-Geon;Kim, Il-Kwon;Yu, Seon-Young;Kwon, Wook;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1530-1535
    • /
    • 2011
  • Heat radiation of LED luminaires has risen a problem when applied indoor. LEDs can save energy with higher efficacy than other light sources. However, their heat radiation may increase power consumption for air-conditioning. Therefore, this paper carried out a comparative analysis on the amount of heat radiation for MR16, E26 bulb, and down-light which will be replaced to LED luminaires. Heat amount of LED-MR16 and LED-downlight was 48% and 87.5% lower than that of conventional lamps, halogen MR16 and E26 CFL, respectively. Consequently, the heat amount and indoor temperature were proportional to the power consumption of luminaire. Therefore, the use of LED luminaire can reduce the amount of heat radiation as well as power consumption.

  • PDF

EFFICIENT NUMERICAL METHODS FOR THE KDV EQUATION

  • Kim, Mi-Young;Choi, Young-Kwang
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.15 no.4
    • /
    • pp.291-306
    • /
    • 2011
  • We consider the second order Strang splitting method to approximate the solution to the KdV equation. The model equation is split into three sets of initial value problems containing convection and dispersal terms separately. TVD MUSCL or MUSCL scheme is applied to approximate the convection term and the second order centered difference method to approximate the dispersal term. In time stepping, explicit third order Runge-Kutta method is used to the equation containing convection term and implicit Crank-Nicolson method to the equation containing dispersal term to reduce the CFL restriction. Several numerical examples of weakly and strongly dispersive problems, which produce solitons or dispersive shock waves, or may show instabilities of the solution, are presented.

An Alternating Implicit Block Overlapped FDTD (AIBO-FDTD) Method and Its Parallel Implementation

  • Pongpaibool, Pornanong;Kamo, Atsushi;Watanabe, Takayuki;Asai, Hideki
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.137-140
    • /
    • 2002
  • In this paper, a new algorithm for two-dimensional (2-D) finite-difference time-domain (FDTD) method is presented. By this new method, the maximum time step size can be increased over the Courant-Friedrich-Levy (CFL) condition restraint. This new algorithm is adapted from an Alternating-Direction Implicit FDTD (ADI-FDTD) method. However, unlike the ADI-FDTD algorithm. the alternation is performed with respect to the blocks of fields rather than with respect to each respective coordinate direction. Moreover. this method can be efficiently simulated with parallel computation. and it is more efficient than the conventional FDTD method in terms of CPU time. Numerical formulations are shown and simulation results are presented to demonstrate the effectiveness and efficiency of our proposed method.

  • PDF

DEVELOPMENT OF A 2-D UNSTEADY FLOW SIMULATION CODE USING CARTESIAN MESHES (직교격자를 이용한 2차원 비정상 유동해석 코드 개발)

  • Jung, Min-Kyu;Lee, Jae-Eun;Park, Se-Youn;Kwon, Oh-Joon;Kwon, Jang-Hyuk;Shin, Ha-Yong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.116-120
    • /
    • 2009
  • A two-dimensional unsteady inviscid flow solver has been developed for the simulation of complex geometric configurations on adaptive Cartesian meshes. Embedded condition was used for boundary condition and a predictor-corrector explicit time marching scheme was used for time-accurate numerical simulation. The Cartesian mesh generator, which was previously developed for steady problem, was used grid generation for unsteady flow. The solver was based on ALE formulation for body motion. For diminishing the effects of cut-cells, the cell merging method was used. Using cell merging method, it was eliminated the CFL constraints. The conservation problem, which is caused cell-type variation around region swept by solid boundary, was also solved using cell merging method. The results are presented for 2D circular cylinder and missile launching problem.

  • PDF

Analysis of Series Arc-Fault Signals Using Wavelet Transform (웨이블렛 변환을 이용한 직렬 아크고장 신호 분석)

  • Bang, Sun-Bae;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.494-500
    • /
    • 2008
  • This paper presents the analyzed result of the series arc fault current by using the discrete wavelet transform. The series arcing is caused by a loose connection in series with the load circuit. The series arc current is limited to a moderate value by the resistance of the device connected to the circuit, such as an appliance or a lighting system. The amount of energy in the sparks from the series arcing is less than in the case of parallel arcing but only a few amps are enough to be a fire hazard. Therefore, it is hard to detect the distinctive difference between a normal current and a intermittent arc current. This paper, presents the variation of the ratio of peak values and RMS values of the series arc fault current, and proposes the novel series arc fault detecting method by using the discrete wavelet transform. Loads such as a CFL lamp, a vacuum cleaner, a personal computer, and a television, which has the very similar normal current with the arc current, were selected to confirm the novel method.

An implicit velocity decoupling procedure for the incompressible Navier-Stokes equations (비압축성 Navier-Stokes 방정식에 대한 내재적 속도 분리 방법)

  • Kim KyounRyoun;Baek Seunr-Jin;Sung Hyunn Jin
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.129-134
    • /
    • 2000
  • An efficient numerical method to solve the unsteady incompressible Navier-Stokes equations is developed. A fully implicit time advancement is employed to avoid the CFL(Courant-Friedrichs-Lewy) restriction, where the Crank-Nicholson discretization is used for both the diffusion and convection terms. Based on a block LU decomposition, velocity-pressure decoupling is achieved in conjunction with the approximate factorization. Main emphasis is placed on the additional decoupling of the intermediate velocity components with only n th time step velocity The temporal second-order accuracy is Preserved with the approximate factorization without any modification of boundary conditions. Since the decoupled momentum equations are solved without iteration, the computational time is reduced significantly. The present decoupling method is validated by solving the turbulent minimal channel flow unit.

  • PDF

Fully-Implicit Decoupling Method for Incompressible Navier-Stokes Equations (비압축성 나비어-스톡스 방정식의 완전 내재적 분리 방법)

  • Kim, Kyoung-Youn;Baek, Seung-Jin;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1317-1325
    • /
    • 2000
  • A new efficient numerical method for computing three-dimensional, unsteady, incompressible flows is presented. To eliminate the restriction of CFL condition, a fully-implicit time advancement in which the Crank-Nicolson method is used for both the diffusion and convection terms, is adopted. Based on an approximate block LU decomposition method, the velocity -pressure decoupling is achieved. The additional decoupling of the intermediate velocity components in the convection term is made for the fully -implicit time advancement scheme. Since the iterative procedures for the momentum equations are not required, the velocity components decouplings bring forth the reduction of computational cost. The second-order accuracy in time of the present numerical algorithm is ascertained by computing decaying vortices. The present decoupling method is applied to minimal channel flow unit with DNS (Direct Numerical Simulation).