• 제목/요약/키워드: CFD:Computational Fluid Dynamics

검색결과 2,015건 처리시간 0.025초

입자추적 유동해석을 이용한 초음파분무화학기상증착 균일도 예측 연구 (Uniformity Prediction of Mist-CVD Ga2O3 Thin Film using Particle Tracking Methodology)

  • 하주환;박소담;이학지;신석윤;변창우
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.101-104
    • /
    • 2022
  • Mist-CVD is known to have advantages of low cost and high productivity compared to ALD and PECVD methods. It is capable of reacting to the substrate by misting an aqueous solution using ultrasonic waves under vacuum-free conditions of atmospheric pressure. In particular, Ga2O3 is regarded as advanced power semiconductor material because of its high quality of transmittance, and excellent electrical conductivity through N-type doping. In this study, Computational Fluid Dynamics were used to predict the uniformity of the thin film on a large-area substrate. And also the deposition pattern and uniformity were analyzed using the flow velocity and particle tracking method. The uniformity was confirmed by quantifying the deposition cross section with an FIB-SEM, and the consistency of the uniformity prediction was secured through the analysis of the CFD distribution. With the analysis and experimental results, the match rate of deposition area was 80.14% and the match rate of deposition thickness was 55.32%. As the experimental and analysis results were consistent, it was confirmed that it is possible to predict the deposition thickness uniformity of Mist-CVD.

SiCl4 누출 시 수막설비의 방재효과에 대한 수치 해석 연구 (A Numerical Study on the Mitigation Effect of Water Curtain for SiCl4 Toxic Gas Release)

  • 류태인;이은미;김승하;강성미;신창현;조승범
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.43-50
    • /
    • 2023
  • Silicone tetrachloride (SiCl4) leak accidents cause enormous human and environmental damage because it is highly toxic. Some handling facilities use water curtains to reduce the impact range of SiCl4. Although the water curtain is known as one of the most efficient technologies for post-release mitigation, its effect on reducing SiCl4 concentration needs to be investigated scientifically and quantitatively. In this study, three-dimensional computational fluid dynamics (CFD) was used to investigate the physical and chemical effects of water curtains as a release-mitigation system for SiCl4. SiCl4 is released and dispersed five seconds prior to the operation of the water curtain. Once the water curtain works, the SiCl4 reacts chemically with the water and its concentration decreases rapidly; it reaches an emergency response planning guidelines level 2 (ERPG-2) of 5 parts per million (ppm) at about 570 m. We observed, however, that the physical effect of water curtains on reducing SiCl4 concentration is insignificant when the chemical effect is eliminated. These results are crucial since they can be a scientific and quantitative basis for the 'technical guidelines for estimating the accident affected range'. In order to protect the public from chemical accidents, more toxic gas mitigation technologies need to be developed.

The Impact of Double-Skin Façades on Indoor Airflow in Naturally Ventilated Tall Office Buildings

  • Yohan, Kim;Mahjoub M. Elnimeiri;Raymond J. Clark
    • 국제초고층학회논문집
    • /
    • 제12권2호
    • /
    • pp.129-136
    • /
    • 2023
  • Natural ventilation has proven to be an effective passive strategy in improving energy efficiency and providing healthy environments. However, such a strategy has not been commonly adopted to tall office buildings that traditionally rely on single-skin façades (SSFs), due to the high wind pressure that creates excessive air velocities and occupant discomfort at upper floors. Double-skin façades (DSFs) can provide an opportunity to facilitate natural ventilation in tall office buildings, as the fundamental components such as the additional skin and openings create a buffer to regulate the direct impact of wind pressure and the airflow around the buildings. This study investigates the impact of modified multi-story type DSFs on indoor airflow in a 60-story, 780-foot (238 m) naturally ventilated tall office building under isothermal conditions. Thus, the performance of wind effect related components was assessed based on the criteria (e.g., air velocity and airflow distribution), particularly with respect to opening size. Computational fluid dynamics (CFD) was utilized to simulate outdoor airflow around the tall office building, and indoor airflow at multiple heights in case of various DSF opening configurations. The simulation results indicate that the outer skin opening is the more influential parameter than the inner skin opening on the indoor airflow behavior. On the other hand, the variations of inner skin opening size help improve the indoor airflow with respect to the desired air velocity and airflow distribution. Despite some vortexes observed in the indoor spaces, cross ventilation can occur as positive pressure on the windward side and negative pressure on the other sides generate productive pressure differential. The results also demonstrate that DSFs with smaller openings suitably reduce not only the impact of wind pressure, but also the concentration of high air velocity near the windows on the windward side, compared to SSFs. Further insight on indoor airflow behaviors depending on DSF opening configurations leads to a better understanding of the DSF design strategies for effective natural ventilation in tall office buildings.

슬릿 노즐 내부 압력 분포와 코팅 박막 두께 균일도 간의 상관관계 연구 (Study on Correlation Between the Internal Pressure Distribution of Slit Nozzle and Thickness Uniformity of Slit-coated Thin Films)

  • 김기은;나정필;정모세;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.19-25
    • /
    • 2023
  • With an attempt to investigate the correlation between the internal pressure distribution of slit nozzle and the thickness uniformity of slot-coated thin films, we have performed computational fluid dynamics (CFD) simulations of slit nozzles and slot coating of high-viscosity (4,800 cPs) polydimethylsiloxane (PDMS) using a gantry slot-die coater. We have calculated the coefficient of variation (CV) to quantify the pressure and velocity distributions inside the slit nozzle and the thickness non-uniformity of slot-coated PDMS films. The pressure distribution inside the cavity and the velocity distribution at the outlet are analyzed by varying the shim thickness and flow rate. We have shown that the cavity pressure uniformity and film thickness uniformity are enhanced by reducing the shim thickness. It is addressed that the CV value of the cavity pressure that can ensure the thickness non-uniformity of less than 5% is equal to and less than 1%, which is achievable with the shim thickness of 150 ㎛. It is also found that as the flow rate increases, the average cavity pressure is increased with the CV value of the pressure unchanged and the maximum coating speed is increased. As the shim thickness is reduced, however, the maximum coating speed and flow rate decrease. The highly uniform PDMS films shows the tensile strain as high as 180%, which can be used as a stretchable substrate.

  • PDF

방제드론 전용노즐의 유효살포폭 내 액적분포 및 수치해석 시뮬레이션 (Simulation of The Effective Distribution of Droplets and Numerical Analysis of The Control Drone-Only Nozzle)

  • 임진택;유성구
    • 문화기술의 융합
    • /
    • 제10권2호
    • /
    • pp.531-536
    • /
    • 2024
  • 최근 농업분야의 스마트 농기계로 분류되고 있는 방제드론은 농촌지역의 고령화 시대를 맞이하여 작업 시간 단축과 방제효과를 높이기 위해 하드웨어 및 소프트웨어를 결합하여 스마트 방제 및 자동방제 시스템 구축을 위해 노력하고 있다. 본 논문에서는 관리관제 및 자동방제 시스템 구축을 위한 기초연구로 방제드론 전용노즐의 특성을 분석하였다. 다양한 드론 모델의 종류, 방제사, 바람, 비행속도, 비행고도, 날씨 조건, UAV 농약 종류 등 다양한 변수를 고려하기 위해서는 노즐의 특성파악과 범용성을 고려하여 약제살포 기준 제시가 가능한 관련 연구가 필요하다. 따라서 다양한 변수 고려가 가능하도록 자체 설계노즐을 기반으로 유동해석(CFD) 시뮬레이션을 실시하고 감수지 실험을 통하여 액적분포의 이론값과 실험값을 비교 분석하였다. 추후 드론운용에 따른 다양한 변수를 고려하여 정확한 비산을 산출하고 관리관제 및 자동방제 시스템에 활용하고자 한다.

ML-based prediction method for estimating vortex-induced vibration amplitude of steel tubes in tubular transmission towers

  • Jiahong Li;Tao Wang;Zhengliang Li
    • Structural Engineering and Mechanics
    • /
    • 제90권1호
    • /
    • pp.27-40
    • /
    • 2024
  • The prediction of VIV amplitude is essential for the design and fatigue life estimation of steel tubes in tubular transmission towers. Limited to costly and time-consuming traditional experimental and computational fluid dynamics (CFD) methods, a machine learning (ML)-based method is proposed to efficiently predict the VIV amplitude of steel tubes in transmission towers. Firstly, by introducing the first-order mode shape to the two-dimensional CFD method, a simplified response analysis method (SRAM) is presented to calculate the VIV amplitude of steel tubes in transmission towers, which enables to build a dataset for training ML models. Then, by taking mass ratio M*, damping ratio ξ, and reduced velocity U* as the input variables, a Kriging-based prediction method (KPM) is further proposed to estimate the VIV amplitude of steel tubes in transmission towers by combining the SRAM with the Kriging-based ML model. Finally, the feasibility and effectiveness of the proposed methods are demonstrated by using three full-scale steel tubes with C-shaped, Cross-shaped, and Flange-plate joints, respectively. The results show that the SRAM can reasonably calculate the VIV amplitude, in which the relative errors of VIV maximum amplitude in three examples are less than 6%. Meanwhile, the KPM can well predict the VIV amplitude of steel tubes in transmission towers within the studied range of M*, ξ and U*. Particularly, the KPM presents an excellent capability in estimating the VIV maximum amplitude by using the reduced damping parameter SG.

하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석 (CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO)

  • 조성환;이종현;김대영
    • 방사성폐기물학회지
    • /
    • 제18권2_spc호
    • /
    • pp.327-336
    • /
    • 2020
  • HANARO (High-flux Advanced Neutron Application Reactor)는 우라늄의 핵분열 연쇄반응에서 생성된 중성자를 이용하여 다양한 연구개발을 수행하는 열출력 30 MW 규모의 연구용 원자로이다. 탈기탱크는 HANARO의 부속시설에 설치되어 있다. 탈기탱크는 내부환경요인으로 인해 기체오염물질을 발생시킨다. 탈기탱크는 기체오염물질을 허용 가능한 수준 이하로 유지하기위해 필요하며 기체시료채취판넬의 분석기에 의해 모니터링 된다. 응축수가 발생하여 기체시료채취판넬의 분석기 내부로 유입된다면, 분석기의 측정 챔버 내부에 부식이 발생하여 고장을 야기한다. 응축수의 생성 원인은 탈기탱크에 존재하는 기체가 분석기로 유입되는 과정에서 탈기탱크와 분석기사이 온도 차이다. 응축수 생성을 억제하고 계통 내부에 생성된 응축수를 효율적으로 제거하기 위해 탈기탱크와 기체시료채취판넬 사이에 히팅시스템이 설치되었다. 이 연구에서 우리는 히팅시스템의 효율성을 알고자 한다. 또한 Wall Condensation Model을 이용하여 유체 입구온도, 외부온도 및 히팅 케이블 설정온도 변화에 따른 파이프 온도와 평균응축량의 변화를 모델링하였다.

코일형 PHC 에너지파일의 열적 거동 및 설계법에 관한 연구 (Study on Thermal Behavior and Design Method for Coil-type PHC Energy Pile)

  • 박상우;손정락;박용부;류형규;최항석
    • 한국지반공학회논문집
    • /
    • 제29권8호
    • /
    • pp.37-51
    • /
    • 2013
  • 에너지파일은 말뚝 내부에 열교환을 위한 순환파이프를 설치하여 파이프 내에 열전달 유체를 순환시킴으로써 주변 지반의 열에너지와 말뚝 간의 열교환을 가능하게 한 구조물이다. 에너지파일은 기존의 지중 열교환기와 비교하여 경제적, 시공적인 측면에서 많은 장점을 가지고 있다. 본 논문에서는 코일형 PHC 에너지파일을 시공하여 그 열적거동을 실험 및 수치해석을 통하여 평가하였으며, 해당 에너지파일의 예비설계를 수행하였다. 현장 시공된 코일형 PHC 에너지파일에 대한 현장 열응답시험(thermal response test, TRT)를 실시하고, 이 결과를 Man et al.(2010)이 제안한 개선된 원통형 열원 모델(solid cylinder source model) 결과와 비교하였다. 또한 현장 열응답 시험 결과를 FLUENT를 이용한 전산유체(computational fluid dynamics, CFD) 수치해석을 통해 모사함으로써, 대상 지반의 열전도도를 역해석을 통해 산정하였다. 코일형 PHC 에너지파일에 설치된 코일형 열교환 파이프의 파이프 루프 간 간격에 따른 열간섭을 평가하기 위하여 코일피치에 변화를 주며 수치해석을 수행하였으며, 결과를 통해 코일피치에 따른 에너지파일의 열거동 및 열교환 효율을 평가하였다. 마지막으로 수치해석을 통해 코일형 PHC 에너지파일과 일반적인 복합 U-형 열교환 파이프가 삽입된 PHC 에너지파일 간의 열교환 효율을 비교하여 코일형 PHC 에너지파일의 등가 열교환율(또는 등가 환산계수)을 제시하였고, 이를 PILESIM2를 이용한 설계 알고리즘에 적용함으로써 해당 에너지파일의 예비설계를 수행하였다.

다양한 배플 인자에 따른 셀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 수치해석 (Numerical analysis for heat transfer and pressure drop characteristics of )

  • 후영영;박형선;윤준규;임종한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.367-375
    • /
    • 2014
  • 셀-튜브 열교환기는 산업분야에서 가장 널리 사용되는 열교환기이다. 열교환기의 열적 성능을 개선하기 위하여 셀-튜브 열교환기에 대해 배플의 배치, 배플의 방향, 배플의 표면의 돌기형상 등의 인자를 변경하였으며, 유동의 박리 및 경계층해석에 적절히 이용되는 SST 난류모델을 적용하여 열전달특성을 고찰하였다. CFD해석시 경계조건는 셀측의 입구온도를 344K로 일정하게 하고, 물의 유량을 6, 12, 18, 24 l/min로 변화시켰다. 그 결과로는 지그재그형 배치가 열전달률 및 압력강하가 향상되는 것으로 나타났으며, 배플의 방향은 기존형보다 수직형 및 각도 $45^{\circ}$형이 열전달이 향상되는 것으로 나타났고, 압력강하는 거의 차이가 없었다. 또한 배플의 돌기형상은 열전달면적을 증가시킴으로써 열전달률 및 압력강하가 향상됨을 알 수 있었다. 해석결과를 통하여 열전달 증가가 유동의 박리, 유체의 체류시간, 튜브와의 접촉면적, 유량, 와류 등에 따라 크게 영향을 받는다는 것을 알 수 있었다.

반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I) (A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter)

  • 권영현;김진욱;정유진;김민철;이재정;이강우;손병현
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4656-4663
    • /
    • 2010
  • 본 연구에서는 복합 후처리장치의 최적 모델 개발을 위해 반응기 내부 유동 특성 및 유량 분배 수준, 공기 연령, 체류시간 등과 관련지어 3차원 전산유체역학(CFD)을 수행하였다. 백필터의 각 격실별로 유량 분배가 크게 차이가 발생해 반건식 반응기(SDR)에 편류현상이 발생할 것으로 예측되어 백필터에 균등한 유량 분배를 위한 구조 개선이 시급한 것으로 나타났다. 또한 SDR의 유입구 구조 변경을 통해 반응기 내부의 속도장과 체류시간 분포 특성을 개선할 수 있는 것으로 나타났다. 본 해석을 이용하여 수정 보완한 배가스 복합 후처리장치는, 반건식 반응기와 백필터 처리부가 일체화되어 있어 장치가 콤팩트하고 설치면적이 적으며 운영 및 관리가 매우 편리할 것으로 판단된다.