• Title/Summary/Keyword: CFC

Search Result 272, Processing Time 0.024 seconds

Study of Muffler for Rotary Compressor by Taguchi Method Viewpoint (회전형 압축기용 머플러의 연구 (1) : 다꾸찌 기법 관점에서)

  • 박성근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.542-547
    • /
    • 1998
  • As the concern for a global energy conservation and environmental protection are increasing, it has been more important thing to correspond with CFC depletion. Alternate refrigerants have merit such as lower global warming effect, but also have demerits such as lower efficiency, miscibility, increasing noise and poor reliability problems. Then we have to develop more efficient, silent and robust compressors to satisfying world-wide demand. In this paper, parametric study on rotary compressor muffler for a room air-conditioner was carried out to investigate the effect of important design variables on noise by using Taguchi robust design method with signal-to-noise(S/N) ratio. Taguchi method seems to be helpful for finding optimum value of design variables for noise level. We also applied neural network to find optimal value of design variables.

  • PDF

A Study on Optical Analysis and Overprinting Sequence in 2-Color Solid Overprints (2색 중첩 민인쇄의 광학적 해석과 중첩인쇄 순서에 관한 연구)

  • 강상훈
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.15 no.2
    • /
    • pp.1-4
    • /
    • 1997
  • Existing cleaning solvent using screen printing are the organic solvents including aromatic compounds carried with poisonous and stench. besides, Cleaning method of current screen printing are for the most part mixed cleaning method of dipping and polish. Using 1,1,1-TCE, CFC-113 alternative system cleaning solvent be substituted for existing cleaning solvent against screen printing ink measured the cleaning efficiency according to gravimetric analysis method and property change of gassamer according to Image Analyzer. Also, Cleaning process system carry with excellent cleaning efficiency studied which was proposed new cleaning process including ultrasonic cleaning process be substituted for existing mixed cleaning method of dipping and polish.

  • PDF

Experimental study on heat transfer inside inclined thermosyphon with low integral-fins (낮은 핀을 가진 경사 써모사이폰의 열전달 성능에 관한 실험적 연구)

  • 조동현;권혁홍
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.165-172
    • /
    • 1998
  • An experimental study on the heat transfer of the inclined thermosyphon with low integral-fins in which boiling and condensation occurred is performed to investigate its heat transfer performance. Water and CFC-30 have been used as the working fluids. The operating temperature and the inclination angle of thermosyphon have been used as the experimental parameters. The heat flux input and the inclination angle $\theta$ towards the vertical position were varied in steps. The heat transfer rate in the thermosyphon was depended upon the inclination angle. In addition, it is to obtain the overall heat transfer coefficients and the characteristics as a operating temperature for the practical applications.

  • PDF

Desiccant Air Conditioning System market and Prospect (데시칸트 공조시장 및 전망)

  • Park, Seung-Tae;Chung, Kwang-Seop;Kim, Young-Il;Park, Jong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.230-235
    • /
    • 2009
  • The Desiccant air conditioning system has been designed as the industrial dehumidifier under the leadership of developed countries, considering CFC problems in 1990, indoor air quality(IAQ) and outdoor air intake rates. This could make the technical differences between them and us. Nowadays, domestic technology has been developed in some parts but there still remain many challenges to be managed. In this study, these tasks would be handled according to the desiccant air conditioning system market and prospects.

  • PDF

Two-Phase Flow Patterns of $CO_{2}$ in a Heated Narrow Rectangular Channel (미세사각채널에서 $CO_{2}$의 이상유동 양식에 관한 연구)

  • Kim Yongchan;Yun Rin;Chung Jin Taek
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.2
    • /
    • pp.66-72
    • /
    • 2004
  • The heat transfer and pressure drop characteristics of $CO_{2}$ are substantially different from those for CFC and HCFC refrigerants. In addition, geometric effects on two-phase flow patterns of $CO_{2}$ are also very significant in many respects. Therefore, two-phase flow patterns of $CO_{2}$ in a narrow rectangular channel or a small diameter tube whose gap size or hydraulic diameter is less than 2 mm are very important to understand heat transfer characteristics and to develop an appropriate heat transfer correlation. In the present study, the evaporation process of $CO_{2}$ in a narrow rectangular channel is visualized at various test conditions, and then the effects of operating conditions are analyzed.

  • PDF

접촉압력을 고려한 R-134a용 냉도기유의 윤활성 평가 연구

  • 나병철;전경진;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.145-151
    • /
    • 1997
  • PAG(Polyalkylene Glycol) and esters are tested with HFC-134a as a refrigeration oil. This investigation enhances the testing method by taking the compressor's environment into account. A testing environment charged with refrigerant gas more closely simulates the conditions of a compressor. The friction coetTicient of the PAG/HFC-134a system is similar to that of the mineral oil/CFC-12 system at operating conditions. Ester oils are preferable at the start & stop condition in the lubricity aspect. PAG shows good lubricity in conditions of extreme contact pressure. Consequently, this test provides reliable results on compressor lubricity of refrigeration oils with HFC-134a. It suggests a methodological way for the proper selection of refrigeration oils that may improve the durability and performance of a compressor.

  • PDF

Effect of heat Leak on Cycle Characteristics of Refrigerator (냉장고 사이클 특성에 미치는 열손실량의 영향)

  • 신진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.871-879
    • /
    • 1998
  • The refrigerator consists of many components such as compressor condenser expansion valve evaporator and the cabinet which filled by urethane foam. In this paper the heat leakage of refriger-ator is measured by the new experiment method which is different from a present method, The devi-ation of the UA(overall heat transfer coefficient times area) between the simulation and experiments is about 7-8%. Using the modeling of various components of refrigeration system a performance analysos of CFC 12 and HFC 134a is performed numerically on the UA. As the results of this study according to increase the heat leakage the refrigeration load and mass flow rate of refrigerant are increased. And the increase of the mass flow rate results in the increase of the condensing and evapo-rating temperature. Therefore according to increase of the heat leakage the COP leads to increase because the increase of refrigeration capacity is larger than the increase if compressor power.

  • PDF

Measurements of $CH_4$ Flux from Landfill Surface and Theoretical Estimation in Its Emission (매립지 표면으로부터의 $CH_4$ 배출량 측정과 이론적 장래배출량 예측)

  • 김득수;오진만;고현석;두강진;장영기;전의찬
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.200-202
    • /
    • 2000
  • 온실가스의 배출자료는 기후변화협약 참여협상 및 저감대책 수립에 없어서는 안될 중요한 기초자료이다. 그러나 국내에서는 현재 에너지와 농업 분야를 제외하고는 온실가스의 배출원 및 배출량 조사가 미미한 실정이다. 이번 연구에서는 기후변화와 관련된 온실효과에 커다란 기여를 하고 있는 메탄($CH_4$)의 매립지 표면으로부터의 국내 배출량을 조사하고자 한다. $CO_2$, $CH_4$, $N_{2}O$, $O_3$, CFC 등의 주요 온실가스들은 여러 경로를 통해서 대기로 배출되고 있으며, 온실가스의 배출기여도를 보면 도시쓰레기의 매립이 전체 배출량에 약 3%정도 기여하는 것으로 보고되었다. (중략)

  • PDF

Simulation of Refrigerator Characteristics (냉장고 특성 시뮬레이션)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.181-189
    • /
    • 1998
  • A general steady-state model for simulation on domastic refrigerator has been developed. The system model consists of various standard components such as evaporator compressor condenser capillary tube and cabinet. Cabinet is not system component but influence characteristic on domastic refrigerator. The purpose of this paper is to compare between characteristics of HFC 134a with CFC 12 in the domastic refrigerator and to predict the steady state cycle performance which is various specifications of cycle components under the continuous running conditions. As the results of simulation the coefficient of performance of both condenser and evaporator increases with increasing UA the increasing rate for condenser is greater than for evaporator.

  • PDF