• 제목/요약/키워드: CF-11

검색결과 283건 처리시간 0.022초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

암환자를 위한 호스피스 케어에 관한 탐색적 연구 (An Exploratory Study of Hospice Care to Patients with Advanced Cancer)

  • 박혜자
    • 대한간호
    • /
    • 제28권3호
    • /
    • pp.52-67
    • /
    • 1989
  • True nursing care means total nursing care which includes physical, emotional and spiritual care. The modern nursing care has tendency to focus toward physical care and needs attention toward emotional and spiritual care. The total nursing care is mandatory for patients with terminal cancer and for this purpose, hospice care became emerged. Hospice case originated from the place or shelter for the travellers to Jerusalem in medieval stage. However, the meaning of modem hospice care became changed to total nursing care for dying patients. Modern hospice care has been developed in England, and spreaded to U.S.A. and Canada for the patients with terminal cancer. Nowaday, it became a part of nursing care and the concept of hospice care extended to the palliative care of the cancer patients. Recently, it was introduced to Korea and received attention as model of total nursing care. This study was attempted to assess the efficacy of hospice care. The purpose of this study was to prove a difference in terms of physical, emotional a d spiritual aspect between the group who received hospice care and who didn't receive hospice care. The subject for this study were 113 patients with advanced cancer who were hospitalized in the S different hospitals. 67 patients received hospice care in 4 different hospitals, and 46 patients didn't receive hospice care in another 4 different hospitals. The method of this study was the questionaire which was made through the descriptive study. The descriptive study was made by individual contact with 102 patients cf advanced cancer for 9 months period. The measurement tool for questionaire was made by author through the descriptive study, and included the personal religious orientation obtained from chung(originated R. Fleck) and 5 emotional stages before dying from Kubler Ross. The content ol questionaire consisted in 67 items which included 11 for general characteristics, 10 for related condition with cancer, 13 for wishes far physical therapy, 13 for emotional reactions and 20 for personal religious orientation. Data for this study was collected from Aug. 25 to Oct. 6 by author and 4 other nurse's who received education and training by author for the collection of data. The collected data were ana lysed using descriptive statistics, $X^2-test$, t-test and pearson correlation coefficient. Results of the study were as follows: "H.C Group" means the group of patient with cancer who received hospice care. "Non H.C Group" means the group of patient with cancer who did not receive hospice care. 1. There is a difference between H.C Group and Non H.C Group in term of the number of physical symptoms, subjective degree of pain sensation and pain control, subjective beliefs in physical cure, emotional reaction, help of present emotional and spiritual care from other personal, needs of emotional and spiritual care in future, selection of treatment method by patients and personal religious orientation. 2. The comparison of H.C Group and Non H.C Group 1) There is no difference in wishes for physical therapy between two groups(p=.522). Among Non H.C Group, a group, who didn't receive traditional therapy and herb medicine was higher than a group who received these in degree of belief that the traditional therapy and herb medicine can cure their disease, and this result was higher in comparison to H.C Group(p=.025, p=.050). 2) Non H.C Group was higher than H.C Group in degree of emotional reaction(p=.050). H.C Group was higher than Non H.C Group in denial and acceptant stage among 5 different emotional stages before dying described by Kubler Ross, especially among the patient who had disease more than 13 months(p=.0069, p=.0198). 3) Non H.C Group was higher than H. C Group in demanding more emotional and spiritual care to doctor, nurse, family and pastor(p=. 010). 4) Non H.C Group was higher than H.C Group in demanding more emotional and spiritual care to each individual of doctor, nurse and family (p=.0110, p=.0029, P=. 0053). 5) H.C Group was higher th2.n Non H.C Group in degree of intrinsic behavior orientation and intrinsic belief orientation of personal religious orientation(p=.034, p=.026). 6) In H.C Group and Non H.C Group, the degree of emotional demanding of christians was significantly higher than non christians to doctor, nurse, family and pastor(p=. 000, p=.035). 7) In H.C Group there were significant positive correlations as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and: the degree of intrinsic behavior orientation in personal religious orientation(r=. 5512, p=.000). (2) Between the degree of emotional demandings to doctor, nurse. family & pastor and the degree of intrinsic belief orientation in personal religious orientation(r=.4795, p=.000). (3) Between the degree of intrinsic behavior orientation and the degree of intrinsic: belief orientation in personal religious orientation(r=.8986, p=.000). (4) Between the degree of extrinsic religious orientation and the degree of consensus religious orientation in personal religious orientation (r=. 2640, p=.015). In H.C. Group there were significant negative correlations as following; (1) Between the degree of intrinsic behavior orientation and extrinsic religious orientation in personal religious orientation (r=-.4218, p=.000). (2) Between the degree or intrinsic behavior orientation and consensus religious orientation in personal religious orientation(r=-. 4597, p=.000). (3) Between the degree of intrinsic belief orientations and the degree of extrinsic religious orientation in personal religious orientation(r=-.4388, p=.000). (4) Between the degree of intrinsic belief orientation and the degree of consensus religious orientation in personal religious orientation(r=-. 5424, p=.000). 8) In Non H.C Group there were significant positive correlation as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of intrinsic behavior orientation in personal religious orientation(r= .3566, p=.007). (2) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of intrinsic belief orientation in personal religious orientation(r=.3430, p=.010). (3) Between the degree of intrinsic behavior orientation and the degree of intrinsic belief orientation in personal religious orientation(r=.9723, p=.000). In Non H.C Group there were significant negative correlation as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of extrinsic religious orientation in personal religious orientation(r= -.2862, p=.027). (2) Between the degree of intrinsic behavior orientation and the degree of extrinsic religious orientation in personal religious orientation(r=-. 5083, p=.000). (3) Between the degree of intrinsic belief orientation and the degree of extrinsic religious orientation in personal religious orientation(r=-. 5013, p=.000). In conclusion above datas suggest that hospice care provide effective total nursing care for the patients with terminal cancer, and hospice care is mandatory in all medical institutions.

  • PDF

환경개선(環境改善)을 위한 녹화수목재배(綠化樹木裁培)의 현황(現況) 및 경영분석(經營分析)과 전망(展望) (A Study on the Present Situation, Management Analysis, and Future Prospect of the Ornamental Tree Cultivation with respect to Environmental Improvement)

  • 박태식;김태욱
    • 한국산림과학회지
    • /
    • 제34권1호
    • /
    • pp.31-46
    • /
    • 1977
  • 관상수재배(觀賞樹栽培)의 현황(現況), 생산(生產), 유통과정(流通過程), 문제점(問題點), 전망(展望)과 개선방안(改善方案)을 조사(調査)한 결과(結果)를 요약(要約)하면 다음과 같다. 1. 관상수재배(觀賞樹栽培)의 일반현황(一般現況) (1) 전국(全國)(서울제외(除外))의 관상수재배면적(觀賞樹栽培面積)과 재배자수(栽培者數)는 각각 1,872.02ha, 2,717명(名)으로서 농수산부(農水產部) 집계(集計)와 많은 차이(差異)가 있는데, 이것은 재배업자(栽培業者)들이 조세부담등(租稅負擔等)의 이유(理由)때문에 정확(正確)한 답(答)을 하지 않은 것으로 보여진다. (2) 직업(職業)은 원예(園藝)(관상수포함(觀賞樹包含)), 농업(農業)을 비롯한 일차산업분야(一次產業分野)의 종사자(從事者)들이 대부분이었으며, 공무원(公務員), 회사원(會社員)도 약간 있었다. (3) 관상수재배자(觀賞樹栽培者)는 학력(學歷)이 높을수록 그 수(數)가 많은 경향(傾向)을 보였으며, 연령(年齡)은 청년층(青年層)보다 장년(壯年)에서 노년층(老年層)이 많은 분포(分布)를 보였다. (4) 관상수재배동기(觀賞樹栽培動機)는 취미(趣味)로 시작, 수익(收益)이 높아서 자산저축적(資產貯蓄的)인 취지(趣旨)에서 공한지활용등(空閑地活用等)의 순(順)으로 나타났으며 재배경력(栽培經歷)은 5~10년(年)이 가장 많고, 대체로 5~15년(年)까지의 재배경력(栽培經歷)을 가진 자가 전체(全體)의 약 $\frac{2}{3}$정도를 차지하고 있었다. (5) 관상수재배장소(觀賞樹栽培場所)는 전(田)이 반이상(半以上)이었으며 그밖에 임야(林野), 답(畓), 하천부지등(河川敷地等)의 순(順)으로 전(田)과 답(畓)을 합(合)하면 66.1%로서 전체(全體) 재배장소(栽培場所)의 2/3나 되었다. (6) 관상수(觀賞樹)의 재배면적(栽培面積)은 1,000~3,000평(坪)의 재배자수(栽培者數)가 가장 많고 그 다음이 3,000~10,000평(坪), 10,000평(坪) 이상(以上), 300~1,000평(坪), 300평미만(坪未滿)의 순(順)으로 1정보(町步)(3,000평(坪))이상(以上)의 재배자(栽培者)가 44.3%로 나타났다. 2. 관상수(觀賞樹)의 생산(生產) (1) 관상수원(觀賞樹園)의 경영형태(經營形態)는 부업(副業), 주업(主業), 겸업순(兼業順)이었으며, 경영방식(經營方式)은 기업경영(企業經營), 반자영(半自營), 자영순(自營順)으로서 관상수재배(觀賞樹栽培)에는 고용노동(雇傭勞動)을 많이 사용(使用)하는 것으로 나타났다. (2) 관상수(觀賞樹)의 재배수종(栽培樹種)은 다양한데 30종(種) 미만(未滿)의 재배자(栽培者)가 전체(全體)의 약 3/4, 30종(種) 이상(以上)의 재배자(栽培者)가 전체(全體)의 약 l/4로 나타났다. (3) 1977년(年) 3월말(月末) 현재(現在) 관상수재배자(觀賞樹栽培者)들이 재배(栽培)하고 있는, 10가지 주요관상수종(主要觀賞樹種)은 (1) 향나무류, (2) 철죽류, (3) 회양목, (4) 은행나무, (5) 단풍나무, (6)목련류, (7) 잣나무류, (8) 주목, (9) 사철나무류, (10) 히말라야시다로 나타났다. (4) 출하(出荷)가 곧 가능(可能)한 수종(樹種)은 (1) 향나무류, (2) 회양목, (3) 철죽류, (4) 단풍나무류, (5) 목련류등이었다. 3. 관상수(觀賞樹)의 유통(流通) (1) 관상수(觀賞樹)의 처분(處分)은 주(主)로 중간상인(中間商人)에게 판매(販賣)하고 있었으며, 관상수유통과정(觀賞樹流通過程)은 5가지로 나누어 볼 수 있는데 대부분 중간상인(中間商人)과 하청자(下請者)를 거치며 심지어는 3~4단계의 중간단계(中間段階)를 거치는 유통경로(流通經路)도 실재(實在)하고 있음이 밝혀졌다. 그러므로 관상수(觀賞樹) 거래가격(去來價格)이 마구 조작되고 있어 피해(被害)와 손해(損害)를 입는 것은 생산자(生產者)와 실수요자(實需要者)들이다. 따라서 생산자(生產者)를 보호육성(保護育成)하고 실수요자(實需要者)들에게 보다 싼 적정가격(適正價格)으로 관상수(觀賞樹)를 공급(供給)할 수 있는 단일유통체제(單一流通體制)의 수립(樹立)이 시급히 강구(講究)되어야 할 것이다. (2) 관상수생산자(觀賞樹生產者)들의 관상수판매가격(觀賞樹販賣價格)은 조사결과(調査結果) 입찰가격(入札價格)의 1/2~1/3, 심지어는 수종(樹種)에 따라 1/41~1/5에 불과한 예(例)도 있음이 나타났다. (3) 중간상인(中間商人)들이 얻는 중간이익(中間利益)은 20~50%정도(程度)를 얻는 사람이 대부분인 것으로 본조사결과(本調査結果) 밝혀졌다. 그러므로 관상수유통(觀賞樹流通)의 합리화(合理化)를 기(期)하기 위해서는 중간상인(中間商人)과 하청자(下請者)를 배제(排除)한 생사자(生產者)가 실수요자(實需要者)에게 직매(直賣)할 수 있는 유통경로(流通經路)의 모색(摸索)이 절실히 요청(要請)되며, 생산자(生產者)의 권리(權利)를 보장할 수 있는 방안(方案)도 아울러 검토(檢討)되어야 할 것이다. 4. 관상수(觀賞樹)에 대한 제반(諸般) 문제점(問題點) (1) 최근(最近) 대기업(大企業)에서 관상수재배(觀賞樹栽培) 진출(進出)을 하고 있는데 대해서 관상수재배자(觀賞樹栽培者)들은 (1) 과잉생산(過剩生產)의 초래(招來), (2) 농가(農家)의 부업적(副業的)인 재배(栽培)에 압박(壓迫)을 주기때문 등등의 이유(理由)로 반대의견(反對意見)이 지배적(支配的)이었는데 관계기관(關係機關)에서는 이에 대한 적절(適切)한 대응책(對應策)을 강구(講究)하지 않으면 안될 것이다. (2) 관상수(觀賞樹)의 평탄지(平坦地) 재배금지(栽培禁止)에 대한 반응(反應)은 반대(反對)한다가 지배적(支配的)인 견해(見解)로서 그 이유(理由)를 (1) 신규(新規) 재배자(栽培者)만 규제(規制)해도 법(法)의 목적(目的)이 달성(達成)된다는 것과, (2) 과거(過去)에 합법적(合法的)으로 식재(植栽)한 관상수(觀賞樹)를 무보상(無補賞)으로 옮겨 심게 하는 것은 위법(違法)이 라는 점(點)을 들고 있다. 한편 "농지(農地)의 보전(保全) 및 이용(利用)에 관한 법률(法律)"에 의하여 농수산부(農水產部)가 집계(集計)한 농지환원대상면적(農地還元對象面積)은 전(田)과 답(畓)을 합(合)하여 1,176.39ha로서 이 법(法) 시행(施行)에 앞서 관상수재배자(觀賞樹栽培者)들에 대한 대책(對策)을 강구(講究)한 후(後) 실시(實施)함이 당연(當然)한 처사(處事)요 정당(正堂)한 절차(節次)라고 생각된다. (3) 관상수(觀賞樹)의 대외수출(對外輸出)은 1970년(年) 최초로 편백, 산수유, 오동나무를 수출하기 시작하여 2~3년간 호조(好調)를 보여오다가 최근 부진(不振)현상을 겪고 있는데, 재배업자(栽培業者)들은 그 이유(理由)를 (1) 정보(情報)가 빈약(貧弱)하고 장려책(裝勵策)이 없기 때문, (2) 수입국(輸入國)의 경제불황(經濟不況), (3) 기호(嗜好)에 맞는 신수종(新樹種)의 개발(開發)이 없기 때문 등등으로 보고 있다. 그러나 관상수수출(觀賞樹輸出)은 이제 대일의존(對日依存)에서 구미제국(歐美諸國)쪽으로 돌려야 할 것이며 관상수(觀賞樹)도 새로운 양묘기술(養苗技術)과 번식기술(繁殖技術)을 요(要)하는 특이수종(特異樹種)을 개발(開發)하는 것이 관상수(觀相樹) 수출진흥방안책(輸出振興方案策)이라 생각된다. (4) 관상수(觀賞樹)를 식재(植栽)하여 수입(收入)이 있기 전(前) 을류농지세(乙類農地稅) 납부여부(納付與否)에 대한 관상수(觀賞樹) 재배업자(栽培業者)들의 반응(反應)은 납부(納付)하지 않았다가 납부(納付)하였다는 반응(反應)보다 많았다. 한편 전반적(全般的)인 관상수재배지(觀賞樹栽培地에) 대한 을류농지세액(乙類農地稅額)은 대체로 적당하다는 반응(反應)보다는 세액(稅額)이 너무 많다고 응답(應答)한 사람이 많이 있는 것으로 보아 관계기관(關係機關)에서는 을류농지세(乙類農地稅)의 과세기준(課稅基準)에 대한 재검토(再檢討)를 하여 적정과세(適正課脫)를 하여야 할 것으로 사료(思料)된다. 5. 관상수재배(觀賞樹栽培)에 대한 전망(展望) 및 개선방안(改善方案) (1) 관상수(觀賞樹)의 경기(景氣)는 짧으면 앞으로 2~3년(年), 길면 5~10년내(年內)에 좋아질 것으로 비교적 낙관적(樂觀的) 반응(反應)을 보이고 있는 반면, 앞으로 회복될 가능성이 없다고 비관적 반응(反應)을 보인 예도 약간 있었다. (2) 관상수생산전환(觀賞樹生產轉換)에 대한 반응은 현상유지, 현보유량처분후(現保有量處分後) 전환(轉換), 염가라도 정리(定理)하겠다는 순(順)이었으며, 장기적(長期的)인 안목(眼目)으로 계속 확장(擴張)하고자 한다는 반응(反應)은 그리 많지 않았다. (3) 관상수(觀賞樹)의 규격표준화(規格標準化)에 대한 반응(反應)은 찬성(贊成)한다는 반응(反應)이 지배적(支配的)이나 반대(反對)한다는 사람들도 약간 있었다. 그들은 그 이유(理由)를 (1) 동일규격(同一規格)이라도 재배기술(栽培技術)에 의한 수형상황(樹形狀況)에 따라 가격차(價格差)가 크기 때문, (2) 조림묘목(造林苗木)과 달라 규격통일(規格統一)이 어렵기 때문이라고 하였다. (4) 관상수유통과정(觀賞樹流通過程)의 정비책(整備策)으로 유통기관(流通機關)에서 계통적(系統的)으로 관상수(觀賞樹)를 판매(販賣), 처분(處分)하는데 대해서 찬성(贊成)한다는 반응(反應)이 훨씬 많았으며, 반대자들은 (1) 유통전담기관(流通專擔機關)이 독점(獨占)할 경우의 횡포와, (2) 유통전담기관(流通專擔機關)이 영리화(營利化) 되기 쉽다는 것을 우려하고 있었다. (5) 관상수(觀賞樹)의 과잉생산(過剩生產)을 방지(防止)하고 우량관상수(優良觀賞樹)를 생산(生產)하기 위한 방편으로 관상수재배(觀賞樹栽培)의 허가제(許可制) 또는 인가제(認可制)가 대두(擡頭)되고 있는데 대해서 반대(反對)한다가 찬성(贊成)한다는 반응(反應)보다 약간 높게 나타났으며, 반대이유(反對理由)로는 (1) 부업적(副業的) 관상수재배(觀賞樹栽培)가 불가능(不可能)하다는 것과, (2) 권력(權力)과 결탁한 부조리(不條理)를 초래(招來)하기 쉽다는 것을 들고 있었다.

  • PDF