• Title/Summary/Keyword: CD64

Search Result 227, Processing Time 0.026 seconds

A Correlation between the Fractionation of Heavy Metals in the Paddy Soil of the Mangyeong River Basin and their Uptake by Rice Plants Grown on it (만경강 유역 논 토양 중 중금속 형태분류와 수도체의 흡수량과의 관계)

  • Kim, Seong-Jo;Baek, Seung-Hwa;Moon, Kwang-Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.3
    • /
    • pp.372-382
    • /
    • 1996
  • In order to elucidate the relationship between the mobility of heavy metals in soil and their uptake by plants, the soil samples collected from the Mangyeong River area were analyzed for the contents and existing forms of the heavy metals and the correlation between the contents of heavy metals in the soil and those in various parts of rice plants therefrom. The soil samples were collectes from ten sites in the paddy fields in 1982 and 1990, respectively, and the analysis on heavy metals including Cd, Zn, Cu and Pb was performed. The results are as follows: Total contents of heavy metals in the samples of 1990 were higher than those of 1982. The extent of increase was that Cd, Zn, Cu and Pb were 3, 29, 59 and 8% in top soil and 8, 50, 91 and 8% in sub-soil, respectively. The order of increasing ratio was Cu > Zn > Pb > Cd and the variation of Cd content by sequentially different extraction was organically bound > dilute acid-extractable=Fe-Mn oxide bound > exchangeable > residual fractions and the content of Cd with organically bound was $46.62{\sim}48.08$ and $41.18{\sim}50.18%$ of total Cd in top and sub-soil, respectively. The ratios of immobile heavy metals, Cd, Pb, Cu and Zn, bound within an oxide or silicate matrix of Fe-Mn oxide in top-soil were 21.25, 35.98, 74.18 and 82.12%, respectively, and consequently their mobile ratios of exchangeable, dilute acid-extractable and organically bound were more than 17.88%. Those of mobile Cd, Pb, Cu and Zn were 78.25, 64.02, 25.82 and 17.88%, respectively. Except for Pb a correlation between the contents of Cd, Zn, and Cu of exchangeable and dilute acid-extractable in top-soil and those in leaf blade, stem and panicle axis was significant, but was not significant in sub-soil.

  • PDF

Enantioselective electrophoretic behavior of lipoic acid in single and dual cyclodextrin systems

  • Le, Thi-Anh-Tuyet;Nguyen, Bao-Tan;Phan, Thanh Dung;Kang, Jong-Seong;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.143-152
    • /
    • 2021
  • Capillary electrophoresis (CE) is an effective technique to study chiral recognition because it offers flexibility in adjusting vital factors. Currently, various available cyclodextrins (CDs) can be employed for the chiral separation of numerous analytes. Herein, we investigate the enantioseparation behavior of lipoic acid enantiomers in various types of single and dual CD systems through CE. Additionally, several impacted CE parameters were optimized through the systematic investigation based on the design of experiment (DoE) concept for a single system comprising a heptakis (2,3,6-tri-O-methyl)-β-CD and a dual system containing the combination of the single CD with a sulfated-β-CD. Consequently, absolute enantioresolution was obtained within 15 min on a common standard bare fused-silica capillary (64.5/56 cm in total/effective length, 50/365 ㎛ inner/outer diameter), maintained at 15 ℃ and at an applied voltage of 24 kV. The optimal background electrolyte consisted of 6 mM heptakis (2,3,6-tri-O-methyl)-β-CD dissolved in the solution of 58 mM borate buffer at pH 10. Furthermore, the results of apparent binding constant experiments indicated that the S-enantiomer-heptakis (2,3,6-tri-O-methyl)-β-CD complex exhibited a stronger affinity than its R-enantiomer counterpart. The obtained electrophoretic mobility values could be utilized to interpret the resolution achieved at various CD concentrations and the mobility behavior of the complexes elucidated the migration order of the enantiomers in an electropherogram.

Study on the Hazardous Heavy Metals from Porcelain Dinnerwares (주방용 도자기에서의 유해중금속 용출에 관한 조사연구)

  • 이광호;권기성;전대훈;정동윤;최병희;이선희;이철원
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.4
    • /
    • pp.324-327
    • /
    • 2000
  • The analysis of hazardous heavy metals, such as Pb, Cd and As, was conducted from the porcelain dinnerwares. Total 374 samples of those products in the domestic market were purchased for the study. All the samples were extracted by 4% acetic acid solution, followed by the analysis with AAS(Atomic Absorption Spectroscopy). As a result, Pb and As were detected maximum 8.63$\mu\textrm{g}$/ml, 2.58 ng/ml, respectively. Cd was fecund in a sample as 0.10$\mu\textrm{g}$/ml.

  • PDF

A Study on the Heavy Metal Contents of Common Salts in Korea (우리나라 일부 소금의 중금속 함량에 대한 조사연구)

  • Hwang, Seong-Hi
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.73-86
    • /
    • 1988
  • In order to determine the content levels of trace metals in common salts, 64 bay salt samples were collected from three producing districts and 33 bay salt samples, 32 remade salt samples and 5 fine salt samples were collected from 7 major cities in Korea, from August to September 1987. These were analysed for content levels of Pb, Cd, Cu, Zn and Mn using Atomic Absorption Spectrophotometer. The results were as follows: 1. Lead contents in three type salts were N.D. - 1081.9 $\mu$g/kg and fourteen percent of the 114 samples exceeded the World Health Organization(WHO) criteria of 100$\mu$g/kg. Cadmium contents of samples were N.D.- 382C.5 $\mu$g/kg and five percent of the 114 samples were over the Spanish criteria of 500 $\mu$g/kg. Copper contents of samples were 8,9-214.9 $\mu$g/kg and there was not a sample over the World Health Organization(WHO) criteria of 500 $\mu$g/kg. Zinc contents ranged N.D. - 342.9 $\mu$g/kg and Manganese contents ranged N.D.- 8.31 mg/kg. 2. The comparison of heavy metal contents among the bay salts from three producing districts was significantly different in Pb, Cd and Cu contents. 3. The comparison of heavy metal contents between the bay salts and remade salts was not significantly different in Pb, Cd and Cu contents. 4. The contents of Pb, Cd, Zn and Mn in fine salts were much lower than those of bay salts and remade salts.

  • PDF

A Study on the Levels of Trace Elements in Livestock Products (축산식품중의 미량원소 함량에 관한 연구 - 우, 돈, 계, 계란 및 우유를 중심으로 -)

  • 박향미;김순재;손봉환
    • Korean Journal of Veterinary Service
    • /
    • v.13 no.1
    • /
    • pp.1-20
    • /
    • 1990
  • In order to determine the levels of trace elements in livestock products surveys have been conducted in Inchon area. The samples were obtained from cattle organs, swine organs, chicken organs, eggs and milk. The levels of nine harmful trace elements(As, Cd, Cr, Cu, Fe, Hg, Mn, Pb, Zn) and three trace elements(Ca, Co, Na) were determined by ICP spectrometry, 1. In the survey on 9 harmful metals with 20 cattle, the highest level was 56.90ppm(Fe, liver) and the lowest level was 0.10ppm (Cd, muscle). 2. In the survey on 9 harmful metals with 31 swine, the highest level was 169.71ppm(Fe, lung) and the lowest level was 0.02ppm(Cd, heart). 3. In the survey on 9 harmful metals with 20 chickens, the highest level was 42.64ppm(Fe, liver) and the lowest level was 0.00ppm (Hg, entire organs). 4. In the survey on 9 harmful metals with 23 eggs, the highest level was 26.08ppm(Fe, yolk) and the lowest level was 0.00ppm (Hg, yolk and white). 5. In the survey on 9 harmful metals with 20 cases of milk, the highest level was 6.02ppm(Zn) and the lowest level was 0.04ppm(Cd). 6. In cattle the mean concentrations were highest in seven elements and in milk the mean concentrations were lowest in five elements.

  • PDF

Correlation of Heavy Metal Concentrations between Total Digestion and Aqua Regia Digestion for Sediments from Yeongsan and Seomjin Watersheds (완전분해와 전분해 방법에 의한 영산강.섬진강수계 퇴적물의 중금속농도 상관관계)

  • Oh, Da-Yeon;Choi, Kyoung-Kyoon;Huh, In-Ae;Hwang, In-Seong;Kim, Young-Hoon;Hur, Jin;Shin, Hyun-Sang;Oh, Jeong-Eun;Shin, Won-Sik;Park, Jeong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.32-38
    • /
    • 2011
  • In this study, the correlations of concentrations in sediment heavy metals between two pretreatment methods, total digestion and aqua regia digestion, have been investigated. Total 43 samples had been collected from streams and lakes in Yeongsan and Seomjin watersheds. They were decomposed in two pretreatment methods and five metal components (Cd, Cr, Ni, Pb, Zn) were analyzed. Overall average concentrations of heavy metals were Zn>Cr>Pb>Ni>Cd in the order. The concentrations of aqua regia digestion were 35.0% (Cd), 53.8% (Cr), 66.2% (Ni), 64.4% (Pb) and 76.4% (Zn) of the concentrations of total digestion and heavy metal concentrations of total digestion were higher. Heavy metal concentrations in sediments from lakes were higher than those from streams. The correlation equations between the concentrations of total digestion and aqua regia digestion were obtained. The concentrations of Zn and Ni, which showed strong linear correlations, increased in aqua regia digestion as the concentration in total digestion increased. The linear correlation coefficients between two digestion methods for most analyzed metals were above the average correlation. However, these results can be applied with limitations due to heterogeneity of sediments.

Current Occurrence and Heavy Metal Contamination Assessment of Seepage from Mine Waste Dumping Sites in Korea (국내 광산폐기물 적치장 침출수 발생 현황 및 중금속 오염도 평가)

  • Park, Chang Koo;Kim, Jeong Wook;Jung, Myung Chae;Park, Hyun Sung;Kim, Dong Kwan;Oh, Youn Soo
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.588-595
    • /
    • 2018
  • This study has focused on evaluation of heavy metal contamination in seepage from 23 mine waste dumping sites in Korea. Seepage samples from the sites were taken and analyzed for heavy metals. The maximum levels (mg/L) in the samples were Al 53.98, As 16.19, Cd 1.15 Cu 37.30, Fe 28.64, Mn 39.00, Ni 0.097, Pb 0.750, and Zn 80.18. Among the sites, six mines were selected as continuous monitoring sites. As results of three months' monitoring of the sites, over the water guidelines for As, Cd, Cu, Fe, Mn, Zn and Al in seepage samples were found at two abandoned Au-Ag mines, Cd, Mn, Zn and Al at two Pb-Zn mines, and As, Fe and Mn at two other Fe-W mines. Therefore, those six mines need continuous monitoring on contamination assessment of seepage due to mining activities.

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

A Study on an Intergrated OPAC Model (통합 OPAC의 모형구축에 관한 연구)

  • 김자영;정영미
    • Proceedings of the Korean Society for Information Management Conference
    • /
    • 1994.12a
    • /
    • pp.61-64
    • /
    • 1994
  • 정보봉사의 패러다임이 소유중심에서 접근서비스로 변하는 추세에 기인하여 도서관자동화의 미래 경향은 기존의 소장목록정보와 같은 자체제작 DB외에도 CD-ROM이나 마그네틱테잎으로 구입된 외부제작 DB, 인터넷을 비롯한 네트워크를 통한 외부정보를 제공하고, 더나아가 상업적 온라인서비스까지도 제공하는 통합 OPAC으로 발전하게 될 것이다.

  • PDF