• Title/Summary/Keyword: CC-data

Search Result 494, Processing Time 0.028 seconds

Feasibility Study of Beta Detector for Small Leak Detection inside the Reactor Containment

  • Jang, JaeYeong;Schaarschmidt, Thomas;Kim, Yong Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.154-159
    • /
    • 2018
  • Background: To prevent small leakage accidents, a real-time and direct detection system for small leaks with a detection limit below that of existing systems, e.g. $0.5gpm{\cdot}hr^{-1}$, is required. In this study, a small-size beta detector, which can be installed inside the reactor containment (CT) building and detect small leaks directly, was suggested and its feasibility was evaluated using MCNPX simulation. Materials and Methods: A target nuclide was selected through analysis of radiation from radionuclides in the reactor coolant system (RCS) and the spectrum was obtained via a silicon detector simulated in MCNPX. A window was designed to reduce the background signal caused by other nuclides. The sensitivity of the detector was also estimated, and its shielding designed for installation inside the reactor CT. Results and Discussion: The beta and gamma spectrum of the silicon detector showed a negligible gamma signal but it also contained an undesired peak at 0.22 MeV due to other nuclides, not the $^{16}N$ target nuclide. Window to remove the peak was derived as 0.4 mm for beryllium. The sensitivity of silicon beta detector with a beryllium window of 1.7 mm thickness was derived as $5.172{\times}10^{-6}{\mu}Ci{\cdot}cc^{-1}$. In addition, the specification of the shielding was evaluated through simulations, and the results showed that the integrity of the silicon detector can be maintained with lead shielding of 3 cm (<15 kg). This is a very small amount compared to the specifications of the lead shielding (600 kg) required for installation of $^{16}N$ gamma detector in inside reactor CT, it was determined that beta detector would have a distinct advantage in terms of miniaturization. Conclusion: The feasibility of the beta detector was evaluated for installation inside the reactor CT to detect small leaks below $0.5gpm{\cdot}hr^{-1}$. In future, the design will be optimized on specific data.

The Research Trends of Pharmacopuncture Therapy on Cervical Pain Caused by Traffic Accidents

  • Kim, Dong-young;Hong, Seung-hyo;Han, Soo-yeon;Kim, Won-young;Oh, Seo-hye;Lee, Hyung-woo;Woo, Hyun-su
    • Journal of Pharmacopuncture
    • /
    • v.23 no.4
    • /
    • pp.201-211
    • /
    • 2020
  • Objectives: The purpose of this study is to comprehensively review Korean domestic studies and investigate the research trends of pharmacopuncture therapy on cervical pain caused by traffic accidents. Methods: Domestic studies between February 1999 and May 2020 from four Korean databases were searched with combinations of keywords 'cervical pain', 'traffic accident', 'whiplash injury', and 'pharmacopuncture'. Results: 17 studies were selected for review, including 7 randomized controlled trials, 5 retrospective observational studies, 3 case reports, and 2 non-randomized controlled trials. Each study was reviewed by published year, study type, types of pharmacopuncture solutions, selected acupuncture points, dosage of pharmacopuncture solutions, frequency of treatment, concurrent treatments, outcome measurements, and the effectiveness of pharmacopuncture therapy. The results are as follows: (1) It showed that the total number of published studies had increased slightly in the last 10 years compared to the previous decade. (2) The pharmacopuncture solutions used in the studies were in the following order: Bee-Venom (蜂毒), Jungsongouhyul (中性瘀血), Hwangryunhaedoktang (黃連解毒湯) and Soyeom (消炎). Frequently used acupuncture points were GB20, GV21, A-shi point, GV16, EX-B2, and SI15 in order. (3) The most commonly used total injection dosage was 1.0 cc at a time, and the frequency of treatment was twice a week. (4) Concurrent treatments such as acupuncture, herbal medication, physical therapy and Chuna manual therapy were performed in all 17 studies. (5) Pharmacopuncture therapy showed positive effects on cervical pain caused by traffic accidents in all 17 studies reviewed. Conclusion: Pharmacopuncture therapy was effective in cervical pain caused by traffic accidents in all 17 studies selected. Further studies will be needed using more larger scales and more objective data to confirm the effectiveness of pharmacopuncture therapy and to generalize its application.

Prophylactic Mastectomy and Implant-Based Breast Reconstruction of BRCA1/2 Mutation-Positive Patients in Korea

  • Lee, Joon Seok;Lee, Jeeyeon;Park, Ho Yong;Yang, Jung Dug
    • Journal of Interdisciplinary Genomics
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • Purpose: Mastectomy is performed as a surgical treatment for patients with breast cancer who have the BRCA 1/2 mutation. In this study, we have reported the trends in Korea for both immediate breast reconstruction and prophylactic mastectomy. Methods: This retrospective study was conducted from 2019 to 2021. Both skin-sparing mastectomy and immediate implant-based breast reconstruction with prepectoral and/or subpectoral techniques were performed in five patients with BRCA 1/2 mutations. Data on age; body mass index; cancer stage; BRCA 1/2 mutation; estrogen receptor, progesterone receptor, and human epidermal growth factor receptor 2 expression; diagnosis; and complications were collected. Results: The average (±standard deviation [SD]) age was 44.0±6.48 years old; BMI 24.5±2.25 kg/m2; and breast volumes were 365.8±70.34 and 382.4±96.33 cc for right and left ones, respectively. The BRCA 1 and 2 were diagnosed in four and one patients, respectively. The estrogen and progesterone receptors and human epidermal growth factor receptor 2 were detected in one (20%), one (20%), and three (60%) patients, respectively. The applied implant-based breast reconstruction techniques for ten breasts were subpectoral technique (n=7, 70%) and prepectoral technique (n=3, 30%). For the cancer stage, those with I, II, and III stages were one (20%), two (40%), and one (20%), respectively. There were no major complications such as Infection, seroma. Conclusion: When mastectomy is performed as surgical treatment in BRCA 1/2 mutation positive breast cancer patients, it is possible to obtain a better outcome with both implant-based breast reconstruction and different circumstances between breast cancer and contralateral breast.

Evaluating flexural strength of concrete with steel fibre by using machine learning techniques

  • Sharma, Nitisha;Thakur, Mohindra S.;Upadhya, Ankita;Sihag, Parveen
    • Composite Materials and Engineering
    • /
    • v.3 no.3
    • /
    • pp.201-220
    • /
    • 2021
  • In this study, potential of three machine learning techniques i.e., M5P, Support vector machines and Gaussian processes were evaluated to find the best algorithm for the prediction of flexural strength of concrete mix with steel fibre. The study comprises the comparison of results obtained from above-said techniques for given dataset. The dataset consists of 124 observations from past research studies and this dataset is randomly divided into two subsets namely training and testing datasets with (70-30)% proportion by weight. Cement, fine aggregates, coarse aggregates, water, super plasticizer/ high-range water reducer, steel fibre, fibre length and curing days were taken as input parameters whereas flexural strength of the concrete mix was taken as the output parameter. Performance of the techniques was checked by statistic evaluation parameters. Results show that the Gaussian process technique works better than other techniques with its minimum error bandwidth. Statistical analysis shows that the Gaussian process predicts better results with higher coefficient of correlation value (0.9138) and minimum mean absolute error (1.2954) and Root mean square error value (1.9672). Sensitivity analysis proves that steel fibre is the significant parameter among other parameters to predict the flexural strength of concrete mix. According to the shape of the fibre, the mixed type performs better for this data than the hooked shape of the steel fibre, which has a higher CC of 0.9649, which shows that the shape of fibers do effect the flexural strength of the concrete. However, the intricacy of the mixed fibres needs further investigations. For future mixes, the most favorable range for the increase in flexural strength of concrete mix found to be (1-3)%.

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF

Treatment and Follow-up of Human Papillomavirus Infected Women in a Municipality in Southern Brazil

  • Ruggeri, Joao Batista;Agnolo, Catia Millene Dell;Gravena, Angela Andreia Franca;Demitto, Marcela de Oliveira;Lopes, Tiara Cristina Romeiro;Delatorre, Silvana;Carvalho, Maria Dalva de Barros;Consolaro, Marcia Edilaine Lopes;Pelloso, Sandra Marisa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6521-6526
    • /
    • 2015
  • Background: This study aimed toanalyze the risk behavior for cervical cancer (CC) and the human papillomavirus (HPV) prevalence and resolution among women who received care through the private healthcare network of a municipality in southern Brazil. Materials and Methods: This descriptive and retrospective study was conducted with 25 women aged 20 to 59 years who received care through the private healthcare network and were treated at a specialty clinic in the period from January to December 2012 in a municipality in Northwest Parana, Southern Brazil. Data from medical records with cytological and HPV results were used. Following treatment, these women were followed-up and reassessed after 6 months. Data were statistically analyzed using the t-test and chi-squared test at a 5% significance level. Results: The mean age of the studied women was $27.8{\pm}7.75$ years old, and the majority were married, with paid employment and were non-smokers. The mean age at menarche was $13.0{\pm}0.50$ years old, and the mean age at first intercourse was $17.5{\pm}1.78$ years, with only 8.0% (2) initiating sexual activity at an age ${\leq}15$ years old. The majority had 1 to 2 children (60.0%), while 88.0% reported having had one sexual partner in their lifetime, and all the women were sexually active. A total of 68.0% used a hormonal contraceptive method. All the women had leukorrhea and pain and were infected by a single HPV type. Regarding the lesion grade, 80.0% showed high risk and 20.0% low risk. The most prevalent high-risk HPV strain was 16. Conclusions: These findings provide relevant information on HPV risk factors and infection, as well as the treatment and 6-month follow-up results, in economically and socially advantaged women with no traditional risk factors, corroborating previous reports that different risk factors may be described in different populations. Thus, this study reinforces the fact that even women without the traditional risk factors should undergo HPVmonitoring and assessment to determine the persistence of infection, promoting early diagnosis of the lesions presented and appropriate treatment to thus prevent the occurrence of CC.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

A Study on the Predictability of Hospital's Future Cash Flow Information (병원의 미래 현금흐름 정보예측)

  • Moon, Young-Jeon;Yang, Dong-Hyun
    • Korea Journal of Hospital Management
    • /
    • v.11 no.3
    • /
    • pp.19-41
    • /
    • 2006
  • The Objective of this study was to design the model which predict the future cash flow of hospitals and on the basis of designed model to support sound hospital management by the prediction of future cash flow. The five cash flow measurement variables discussed in financial accrual part were used as variables and these variables were defined as NI, NIDPR, CFO, CFAI, CC. To measure the cash flow B/S related variables, P/L related variables and financial ratio related variables were utilized in this study. To measure cash flow models were designed and to estimate the prediction ability of five cash flow models, the martingale model and the market model were utilized. To estimate relative prediction outcome of cash flow prediction model and simple market model, MAE and MER were used to compare and analyze relative prediction ability of the cash flow model and the market model and to prove superiority of the model of the cash flow prediction model, 32 Regional Public Hospital's cross-section data and 4 year time series data were combined and pooled cross-sectional time series regression model was used for GLS-analysis. To analyze this data, Firstly, each cash flow prediction model, martingale model and market model were made and MAE and MER were estimated. Secondly difference-test was conducted to find the difference between MAE and MER of cash flow prediction model. Thirdly after ranking by size the prediction of cash flow model, martingale model and market model, Friedman-test was evaluated to find prediction ability. The results of this study were as follows: when t-test was conducted to find prediction ability among each model, the error of prediction of cash flow model was smaller than that of martingale and market model, and the difference of prediction error cash flow was significant, so cash flow model was analyzed as excellent compare with other models. This research results can be considered conductive in that present the suitable prediction model of future cash flow to the hospital. This research can provide valuable information in policy-making of hospital's policy decision. This research provide effects as follows; (1) the research is useful to estimate the benefit of hospital, solvency and capital supply ability for substitution of fixed equipment. (2) the research is useful to estimate hospital's liqudity, solvency and financial ability. (3) the research is useful to estimate evaluation ability in hospital management. Furthermore, the research should be continued by sampling all hospitals and constructed advanced cash flow model in dimension, established type and continued by studying unified model which is related each cash flow model.

  • PDF

Assessment of Contribution of Climate and Soil Factors on Alfalfa Yield by Yield Prediction Model (수량예측모델을 통한 Alfalfa 수량에 영향을 미치는 기후요인 및 토양요인의 기여도 평가)

  • Kim, Ji Yung;Kim, Moon Ju;Jo, Hyun Wook;Lee, Bae Hun;Jo, Mu Hwan;Kim, Byong Wan;Sung, Kyung Il
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.41 no.1
    • /
    • pp.47-55
    • /
    • 2021
  • The objective of this study was to access the effect of climate and soil factors on alfalfa dry matter yield (DMY) by the contribution through constructing the yield prediction model in a general linear model considering climate and soil physical variables. The processes of constructing the yield prediction model for alfalfa was performed in sequence of data collection of alfalfa yield, meteorological and soil, preparation, statistical analysis, and model construction. The alfalfa yield prediction model used a multiple regression analysis to select the climate variables which are quantitative data and a general linear model considering the selected climate variables and soil physical variables which are qualitative data. As a result, the growth degree days(GDD) and growing days(GD), and the clay content(CC) were selected as the climate and soil physical variables that affect alfalfa DMY, respectively. The contributions of climate and soil factors affecting alfalfa DMY were 32% (GDD, 21%, GD 11%) and 63%, respectively. Therefore, this study indicates that the soil factor more contributes to alfalfa DMY than climate factor. However, for examming the correct contribution, the factors such as other climate and soil factors, and the cultivation technology factors which were not treated in this study should be considered as a factor in the model for future study.

Spatial Gap-filling of GK-2A/AMI Hourly AOD Products Using Meteorological Data and Machine Learning (기상모델자료와 기계학습을 이용한 GK-2A/AMI Hourly AOD 산출물의 결측화소 복원)

  • Youn, Youjeong;Kang, Jonggu;Kim, Geunah;Park, Ganghyun;Choi, Soyeon;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_3
    • /
    • pp.953-966
    • /
    • 2022
  • Since aerosols adversely affect human health, such as deteriorating air quality, quantitative observation of the distribution and characteristics of aerosols is essential. Recently, satellite-based Aerosol Optical Depth (AOD) data is used in various studies as periodic and quantitative information acquisition means on the global scale, but optical sensor-based satellite AOD images are missing in some areas with cloud conditions. In this study, we produced gap-free GeoKompsat 2A (GK-2A) Advanced Meteorological Imager (AMI) AOD hourly images after generating a Random Forest based gap-filling model using grid meteorological and geographic elements as input variables. The accuracy of the model is Mean Bias Error (MBE) of -0.002 and Root Mean Square Error (RMSE) of 0.145, which is higher than the target accuracy of the original data and considering that the target object is an atmospheric variable with Correlation Coefficient (CC) of 0.714, it is a model with sufficient explanatory power. The high temporal resolution of geostationary satellites is suitable for diurnal variation observation and is an important model for other research such as input for atmospheric correction, estimation of ground PM, analysis of small fires or pollutants.