• Title/Summary/Keyword: CC-data

Search Result 499, Processing Time 0.033 seconds

The -765G>C Polymorphism in the Cyclooxygenase-2 Gene and Digestive System Cancer: a Meta-analysis

  • Zhao, Fen;Cao, Yue;Zhu, Hong;Huang, Min;Yi, Cheng;Huang, Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8301-8310
    • /
    • 2014
  • Background: Published data regarding associations between the -765G>C polymorphism in cyclooxygenase-2 (COX-2) gene and digestive system cancer risk have been inconclusive. The aim of this study was to comprehensively evaluate the genetic risk of the -765G>C polymorphism in the COX-2 gene for digestive system cancer. Materials and Methods: A search was performed in Pubmed, Medline (Ovid), Embase, CNKI, Weipu, Wanfang and CBM databases, covering all studies until Feb 10, 2014. Statistical analysis was performed using Revman5.2. Results: A total of 10,814 cases and 16,174 controls in 38 case-control studies were included in this meta-analysis. The results indicated that C allele carriers (GC+CC) had a 20% increased risk of digestive system cancer when compared with the homozygote GG (odds ratio (OR)=1.20, 95% confidence interval (CI), 1.00-1.44 for GC+CC vs GG). In the subgroup analysis by ethnicity, significant elevated risks were associated with C allele carriers (GC+CC) in Asians (OR = 1.46, 95% CI=1.07-2.01, and p=0.02) and Africans (OR=2.12, 95% CI=1.57-2.87, and p< 0.00001), but not among Caucasians, Americans and mixed groups. For subgroup analysis by cancer type (GC+CC vs GG), significant associations were found between the -765G>C polymorphism and higher risk for gastric cancer (OR=1.64, 95% CI=1.03-2.61, and p=0.04), but not for colorectal cancer, oral cancer, esophageal cancer, and others. Regarding study design (GC+CC vs GG), no significant associations were found in then population-based case-control (PCC), hospital-based case-control (HCC) and family-based case-control (FCC) studies. Conclusions: This meta-analysis suggested that the -765G>C polymorphism of the COX-2 gene is a potential risk factor for digestive system cancer in Asians and Africans and gastric cancer overall.

The Odor Discriminents Analysis and the Comparison of Flavor Components in Korean and Chinese Sesame Oils (한국산 및 중국산 참기름의 향기성분 비교 및 전자코 장치를 이용한 Odor 판별 분석)

  • 권영주;이재곤;등개야;이규희;오만진
    • Food Science and Preservation
    • /
    • v.6 no.2
    • /
    • pp.200-205
    • /
    • 1999
  • This experiment was carried out to search mm reasonable and scientific method to distinguish Korean sesame with Chinese sesame. Sesame samples used in this study were Korean variety cultivated in Chochiwon City of Korea (KvKc), Chinese variety cultivated in Jilin Province of China (CvCc), Chinese variety cultivated in Chochiwon city of Korea (CvKc) and Korean variety cultivated in Jilin Province of China (KvCc). In volatile flavor components analysis, 41 component were identified from KvKc and 39 components from CvCc. Major flavor components were pyrazines and furans. Pyrazines compositions of KvKc and CvCc were 55.4% and 56.8%, respectively while furans compositions of KvKc and CvCc were 27.0% and 20.4%, respectively. Other flavor components pattern showed no difference. When the headspace volatiles of sesame oils were analyzed using Electronic Nose System and the obtained data were interpreted using statistical method of MANOVA and Discriminant analysis, characteristic patterns of sesame oil odors were different from each other according to variety as well as cultivated area. These results suggest that Korean sesame oils may be distinguished from Chinese sesame oils by using Electronic Nose System.

  • PDF

ZNF492 and GPR149 methylation patterns as prognostic markers for clear cell renal cell carcinoma: Array-based DNA methylation profiling

  • Yong‑June Kim;Wooyeong Jang;Xuan‑Mei Piao;Hyung‑Yoon Yoon;Young Joon Byun;Ji Sang Kim;Sung Min Kim;Sang Keun Lee;Sung Pil Seo;Ho Won Kang;Won Tae Kim;Seok Joong Yun;Ho Sun Shon;Keun Ho Ryu;Sang Won Kim;Yun‑Sok Ha;Ghil Suk Yoon;Sang‑Cheol Lee;Tae Gyun Kwon;Wun‑Jae Kim
    • Oncology Letters
    • /
    • v.42 no.1
    • /
    • pp.453-460
    • /
    • 2019
  • The present study aimed to identify novel methylation markers of clear cell renal cell carcinoma (ccRCC) using microarray methylation analysis and evaluate their prognostic relevance in patient samples. To identify cancer-specific methylated biomarkers, microarray profiling of ccRCC samples from our institute (n=12) and The Cancer Genome Atlas (TCGA) database (n=160) were utilized, and the prognostic relevance of candidate genes were investigated in another TCGA dataset (n=153). For validation, pyrosequencing analyses with ccRCC samples from our institute (n=164) and another (n=117) were performed and the potential clinical application of selected biomarkers was examined. We identified 22 CpG island loci that were commonly hypermethylated in ccRCC. Kaplan-Meier analysis of TCGA data indicated that only 4/22 loci were significantly associated with disease progression. In the internal validation set, Kaplan-Meier analysis revealed that hypermethylation of two loci, zinc finger protein 492 (ZNF492) and G protein-coupled receptor 149 (GPR149), was significantly associated with shorter time-to-progression. Multivariate Cox regression models revealed that hypermethylation of ZNF492 [hazard ratio (HR), 5.44; P=0.001] and GPR149 (HR, 7.07; P<0.001) may be independent predictors of tumor progression. Similarly, the methylation status of these two genes was significantly associated with poor outcomes in the independent external validation cohort. Collectively, the present study proposed that the novel methylation markers ZNF492 and GPR149 could be independent prognostic indicators in patients with ccRCC.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF

Diagnosis and Monitoring of Chronic Myeloid Leukemia: Chiang Mai University Experience

  • Tantiworawit, Adisak;Kongjarern, Supanat;Rattarittamrong, Ekarat;Lekawanvijit, Suree;Bumroongkit, Kanokkan;Boonma, Nonglak;Rattanathammethee, Thanawat;Hantrakool, Sasinee;Chai-Adisaksopha, Chatree;Norasetthada, Lalita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2159-2164
    • /
    • 2016
  • Background: A diagnosis of chronic myeloid leukemia (CML) is made on discovery of the presence of a Philadelphia (Ph) chromosome. The success of the treatment of this form of leukemia with tyrosine kinase inhibitor (TKI) is monitored by reduction of the Ph chromosome. Objective: To compare the role of conventional cytogenetic (CC) methods with a real time quantitative polymerase chain reaction (RQ-PCR) and fluorescence in situ hybridization (FISH) for diagnosis and treatment monitoring of CML patients. The secondary outcome was to analyze the treatment responses to TKI in CML patients. Materials and Methods: This was a retrospective study of CML patients who attended the Hematology clinic at Chiang Mai University Hospital from 2005-2010. Medical records were reviewed for demographic data, risk score, treatment response and the results of CC methods, FISH and RQ-PCR. Results: One hundred and twenty three cases were included in the study, 57.7% of whom were male with a mean age of 46.9 years. Most of the patients registered as intermediate to high risk on the Sokal score. At diagnosis, 121 patients were tested using the CC method and 118 (95.9%) were identified as positive. Five patients failed to be diagnosed by CC methods but were positive for BCR-ABL1 using the FISH method. Imatinib was the first-line treatment used in 120 patients (97.6%). In most patients (108 out of 122, 88.5%), a complete cytogenetic response (CCyR) was achieved after TKI therapy and in 86 patients (70.5%) CCyR was achieved long term by the CC method. Five out of the 35 analyzed patients in which CCyR was achieved by the CC method had a positive FISH result. Out of the 76 patients in which CCyR was achieved, RQ-PCR classified patients to only CCyR in 17 patients (22.4%) with a deeper major molecular response (MMR) in 4 patients (5.3%) and complete molecular response (CMR) in 55 patients (72.4%). In the case of initial therapy, CCyR was achieved in 95 patients (79.1%) who received imatinib and in both patients who received dasatinib (100%). For the second line treatment, nilotinib were used in 30 patients and in 19 of them (63.3%) CCyR was achieved. In half of the 6 patients (50%) who received dasatinib as second line or third line treatment CCyR was also achieved. Conclusions: CML patients had a good response to TKI treatment. FISH could be useful for diagnosis in cases where CC analysis failed to detect the Ph chromosome. RQ-PCR was helpful in detecting any residual disease and determining the depth of the treatment response at levels greater than the CC methods.

Comparison of geometrical methods to identify CME 3-D structures

  • Lee, Harim;Moon, Yong-Jae;Na, Hyeonock;Jang, Soojeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.73-73
    • /
    • 2014
  • Several geometrical models (e.g., cone and flux rope models) have been suggested to infer 3-D parameters of CMEs using multi-view observations (STEREO/SECCHI) and single-view observations (SOHO/LASCO). To prepare for when only single view observations are available, we have made a test whether the cone model parameters from single-view observations are consistent with those from multi-view ones. For this test, we select 35 CMEs which are identified as CMEs, whose angular widths are larger than 180 degrees, by one spacecraft and as limb CMEs by the other ones. For this we use SOHO/LASCO and STEREO/SECCHI data during the period from 2010 December to 2011 July when two spacecraft were separated by $90{\pm}10$ degrees. In this study, we compare 3-D parameters of these CMEs from three different methods: (1) a triangulation method using the STEREO/SECCHI and SOHO/LASCO data, (2) a Graduated Cylindrical Shell (GCS) flux rope model using the STEREO/SECCHI data, and (3) an ice cream cone model using the SOHO/LASCO data. The parameters used for comparison are radial velocities, angular widths and source location (angle ${\gamma}$ between the propagation direction and the plan of the sky). We find that the radial velocities and the ${\gamma}$-values from three methods are well correlated with one another (CC > 0.8). However, angular widths from the three methods are somewhat different. The correlation coefficients are relatively not good (CC > 0.4). We also find that the correlation coefficients between the locations from the three methods and the active region locations are larger than 0.9, implying that most of the CMEs are radially ejected.

  • PDF

Performance Comparison and Optimal Selection of Computing Techniques for Corridor Surveillance (회랑감시를 위한 컴퓨팅 기법의 성능 비교와 최적 선택 연구)

  • Gyeong-rae Jo;Seok-min Hong;Won-hyuck Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.770-775
    • /
    • 2023
  • Recently, as the amount of digital data increases exponentially, the importance of data processing systems is being emphasized. In this situation, the selection and construction of data processing systems are becoming more important. In this study, the performance of cloud computing (CC), edge computing (EC), and UAV-based intelligent edge computing (UEC) was compared as a way to solve this problem. The characteristics, strengths, and weaknesses of each method were analyzed. In particular, this study focused on real-time large-capacity data processing situations such as corridor monitoring. When conducting the experiment, a specific scenario was assumed and a penalty was given to the infrastructure. In this way, it was possible to evaluate performance in real situations more accurately. In addition, the effectiveness and limitations of each computing method were more clearly understood, and through this, the help was provided to enable more effective system selection.

Development of a Storage Level and Capacity Monitoring and Forecasting Techniques in Yongdam Dam Basin Using High Resolution Satellite Image (고해상도 위성자료를 이용한 용담댐 유역 저수위/저수량 모니터링 및 예측 기술 개발)

  • Yoon, Sunkwon;Lee, Seongkyu;Park, Kyungwon;Jang, Sangmin;Rhee, Jinyung
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1041-1053
    • /
    • 2018
  • In this study, a real-time storage level and capacity monitoring and forecasting system for Yongdam Dam watershed was developed using high resolution satellite image. The drought indices such as Standardized Precipitation Index (SPI) from satellite data were used for storage level monitoring in case of drought. Moreover, to predict storage volume we used a statistical method based on Principle Component Analysis (PCA) of Singular Spectrum Analysis (SSA). According to this study, correlation coefficient between storage level and SPI (3) was highly calculated with CC=0.78, and the monitoring and predictability of storage level was diagnosed using the drought index calculated from satellite data. As a result of analysis of principal component analysis by SSA, correlation between SPI (3) and each Reconstructed Components (RCs) data were highly correlated with CC=0.87 to 0.99. And also, the correlations of RC data with Normalized Water Surface Level (N-W.S.L.) were confirmed that has highly correlated with CC=0.83 to 0.97. In terms of high resolution satellite image we developed a water detection algorithm by applying an exponential method to monitor the change of storage level by using Multi-Spectral Instrument (MSI) sensor of Sentinel-2 satellite. The materials of satellite image for water surface area detection in Yongdam dam watershed was considered from 2016 to 2018, respectively. Based on this, we proposed the possibility of real-time drought monitoring system using high resolution water surface area detection by Sentinel-2 satellite image. The results of this study can be applied to estimate of the reservoir volume calculated from various satellite observations, which can be used for monitoring and estimating hydrological droughts in an unmeasured area.

Association of a miR-502-Binding Site Single Nucleotide Polymorphism in the 3'-Untranslated Region of SET8 and the TP53 Codon 72 Polymorphism with Cervical Cancer in the Chinese Population

  • Yang, Shao-Di;Cai, Yan-Lin;Jiang, Pei;Li, Wen;Tang, Jian-Xin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6505-6510
    • /
    • 2014
  • Objective: This study was conducted to identify whether polymorphic variants of set domain-containing protein 8 (SET8) and tumor protein p53 (TP53) codon 72, either independently or jointly, might be associated with increased risk for cervical cancer. Methods: We genotyped SET8 and TP53 codon 72 polymorphisms of peripheral blood DNA from 114 cervical cancer patients and 200 controls using the polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and direct DNA sequencing. Results: The frequency of SET8 CC (odds ratios (OR) = 2.717, 95% CI=1.436-5.141) or TP53 GG (OR=2.168, 95% CI=1.149-4.089) genotype was associated with an increased risk of cervical cancer on comparison with the SET8 TT or TP53 CC genotypes, respectively. In additional, interaction between the SET8 and TP53 polymorphisms increased the risk of cervical cancer in a synergistic manner, with the OR being 9.913 (95% CI=2.028-48.459) for subjects carrying both SET8 CC and TP53 GG genotypes. Conclusion: These data suggest that there are significant associations between the miR-502-binding site SNP in the 3'-UTR of SET8 and the TP53 codon 72 polymorphism with cervical cancer in Chinese, and there is a gene-gene interaction.