• Title/Summary/Keyword: CC V2.3

Search Result 105, Processing Time 0.036 seconds

Effect of Low Intensity Pulsed Electric Field on Ethanol Fermentation and Chemical Component Variation in a Winemaking Culture

  • Min, He-Ryeon;Jeon, Bo-Young;Seo, Ha-Na;Kim, Min-Ju;Kim, Jun-Cheol;Kim, Joon-Kuk;Park, Doo-Hyun
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1358-1364
    • /
    • 2009
  • Electric polarity of working electrode and counter electrode was periodically switched at the intervals of 30 sec. Electric current generated by anodic and cathodic reaction of working electrode was reached to +30 and -12 mA in low intensity pulsed electric field (LIPEF). The yeast growth, ethanol production, and malate consumption in the initial cultivation time were more activated in the LIPEF than the conventional condition (CC). Polyphenol, total phenolic contents (TPC), and total flavonols (TF) were gradually decreased in all cultivation conditions during incubation for 2 weeks but antioxidation activity was not. TF was significantly lower in 3 and 4 V of LIPEF than CC and 2 V of LIPEF; however, the polyphenol, TPC, and antioxidation activity were a little influenced by the LIPEF. After ripening of the winemaking culture for 15 days, polyphenol, TPC, and TF were a little increased but the antioxidation activity was not.

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

A High Efficiency Bidirectional Resonant Converter With Auxilary LC Circuit for V2G System (V2G 시스템을 위한 보조 LC 회로를 가진 고효율 양방향 공진형 컨버터)

  • Tranand, Duc-Hung;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.323-324
    • /
    • 2016
  • In this paper a high efficiency bidirectional resonant converterfor Vehicle-to-Grid applications (V2G) is proposed.The proposed converter has adopted an LC auxiliary circuit in the third winding of the transformer. With the proposed method full softswitching can be ensured in all switches over a wide range of loadsand the secondary ringing can be removed with no additional snubber or clamp circuitry.In addition, since the proposed resonant converter is able to operate at an almost constant resonant frequencyregardless of the load, CC/CV charge of the battery can be simply implemented with high efficiency. A 3.3 kW bidirectional converter for On-Board Charger of Electric Vehicle is implemented to verify the validity of the proposed method. The experimental results show the high efficiency characteristics of the proposed converter over the wide range of load in both charge and discharge mode. The maximum efficiency of the proposed system was 98.13 % at 2.3 kW during the constant voltage mode charge operation.

  • PDF

Emission spectroscopic diagnostics of argon arc Plasma in Plasma focus device for advanced lithography light source (차세대 리소그래피 빛샘 발생을 위한 플라스마 집속장치의 아르곤 아크 플라스마의 방출 스펙트럼 진단)

  • Hong, Y.J.;Moon, M.W.;Lee, S.B.;Oh, P.Y.;Song, K.B.;Hong, B.H.;Seo, Y.H.;Yi, W.J.;Shin, H.M.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.581-586
    • /
    • 2006
  • We have generated the argon plasma in the diode chamber based on the established coaxial electrode type and investigated the emitted visible light for emission spectroscopy. We applied various voltages $2\sim3.5kV$ to the device by 0.5kV, and obtained the emission spectrum data for the focused plasma in the diode chamber on the argon pressure of 330 mTorr. The Ar I and Ar II emission line are observed. The electron temperature and ion density have been measured by the Boltzmann plot and Saha equation from assumption of local thermodynamic equilibrium (LTE) The Ar I and Ar II ion densities have been calculated to be $\sim10^{15}/cc\;and\;~10^{13}/cc$, respectively, from Saha equation.

The Changes of Cuff Pressure from Endotracheal Intubation for Long-term Mechanical Ventilation (장기간 기계호흡 환자에서 기관내 관의 기낭압의 변화)

  • Jung, Bock-Hyun;Park, Whan;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.156-165
    • /
    • 2002
  • Background: A tracheal stenosis is caused by mucosal ischemic injury related to a high cuff pressure ($P_{cuff}$) of the endotracheal tube. In contrast, aspiration of the upper airway secretion and impaired gas exchange due to cuff leakage is related to a low $P_{cuff}$. To prevent these complications, the $P_{cuff}$ should be kept appropriately because the appropriate $P_{cuff}$ appears to change according to the patient's daily respiratory mechanics. However, the constant cuff volume($V_{cuff}$) has frequently been instilled to the cuff balloon on a daily basis to maintain the optimal $P_{cuff}$ instead of monitoring the $P_{cuff}$ directly at the patients' bedside. To address the necessity of continuous $P_{cuff}$ monitoring, the change in the $P_{cuff}$ was evaluated at various $V_{cuff}$ levels on a daily basis in patients with long-term mechanical ventilation. The utility of mercury column sphygmomanometer for the continuous monitoring $P_{cuff}$ was also investigated. Method: The change in $P_{cuff}$ according to the increase in $V_{cuff}$ was observed in 17 patients with prolonged endotracheal intubation for mechanical ventilation for 2 week or more. This maneuver measured the change in $P_{cuff}$ daily during the mechanical ventilation days. In addition, the $P_{cuff}$ measured by mercury column sphygmomanometer was compared with the $P_{cuff}$ measured by an automatic cuff pressure manager. Results : There were no statistically significant changes of $P_{cuff}$ during more than 14 days of intubation for mechanical ventilation. However the $V_{cuff}$ required to maintain the appropriate $P_{cuff}$ varied from 1.9 cc to 9.6 cc. In addition, the intra-individual variation of the $P_{cuff}$ was observed from 10 $cmH_2O$ to 46 $cmH_2O$ at constant 3 cc $V_{cuff}$. The $P_{cuff}$ measured by the bedside mercury column sphygmomanometer is well coincident with that measured by the automatic cuff pressure manager. Conclusion: Continuous monitoring and management of the $P_{cuff}$ to maintain the appropriate $P_{cuff}$ level in order to prevent cuff related problems during long-term mechanical ventilation is recommended. For this purpose, mercury column sphygmomanometer may replace the specific cuff pressure monitoring equipment.

Physicochemical Properties of Various Blends of Peatmoss and Perlite and the Selection of Rooting Media for Different Growing Seasons (다양한 종류의 피트모스와 펄라이트 혼합에 따른 물리·화학성 변화와 계절별 육묘를 위한 상토 선발)

  • Shim, Chang Yong;Kim, Chang Hyeon;Park, In Sook;Choi, Jong Myung
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.886-897
    • /
    • 2016
  • The physical properties of rooting media for the establishment of plugs in a greenhouse are modified according to variations in the greenhouse environment throughout the season. In this study, we established a standard for rooting media for the production of plug seedlings for each growing season (summer, winter and spring fall). Eight types of peatmoss (PM) and 4 types of perlite (PL) commonly used in Korea were collected and blended with the ratio of 7 parts PM to 3 parts PL (v/v) to make 32 different rooting media blends. We determined the total porosity (TP), container capacity (CC), air-filled porosity (AFP), pH, and electrical conductivity (EC) of the 32 media blends, and 6 media blends were selected for seasonal use. We also conducted additional analyses for plant easily available water (EAW), buffering water (BW), cation exchange capacity (CEC), and nutrient contents in the 6 media blends. The TP, CC, and AFP of the 32 media blends ranged from 64.7 to 96.0%, 42.9 to 90.1%, and 1.3 to 27.8%, respectively, indicating that the physical properties were strongly influenced by the type of PM and PL. The pH and EC of the PMs ranged from 2.96 to 3.81 and 0.08 to $0.47dS{\cdot}m^{-1}$, respectively. However, after blending the PM with the PL the pH was raised and the EC was lowered The media blends selected for the summer growing season were Blonde Golden peatmoss (BG) + No. 1 perlite size < 1 mm (PE1) and Latagro 0-10 mm (L1) + No. 2 perlite size 1-2 mm (PE2). These two media blends had 89.8-90.9% of TP, 80.8-81.3% of CC, and 9.0-9.7% of AFP. The media blends selected for the winter growing season were Sfagnumi Turvas (ST) + PE2 and Latagro 20-40 mm (L3) + PE2. These media blends had 79.9-86.7% of TP, 60.4-74.9% of CC, and 11.8-19.6% of AFP. The TP, CC, and AFP of two media blends, BG + No.3 perlite 2-5 mm (PE3) and Orange peatmoss (O) + PE3, selected for the spring and fall growing seasons, respectively, were 85.2-87.3%, 77.9%, and 7.4-9.4%, respectively. The percentage of EAW of the media blends selected for the spring, summer, and winter growing seasons ranged from 24.2-24.9%, 22.0-28.6%, and 18.0-21.8%, respectively, but the percentages of BW were not significantly different among the selected root media blends. The pH, EC, and CEC of the 6 selected media blends ranged from 3.11-3.97, $0.06-0.26dS{\cdot}m^{-1}$, and $97-119meq{\cdot}100g^{-1}$, respectively.

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF

Dose comparison between prescription methods according to anatomical variations in intracavitary brachytherapy for cervical cancer

  • Choi, Euncheol;Kim, Jae Ho;Kim, Ok Bae;Byun, Sang Jun;Kim, Jin Hee;Oh, Young Kee
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.227-234
    • /
    • 2018
  • Purpose: We compared how doses delivered via two-dimensional (2D) intracavitary brachytherapy (ICBT) and three-dimensional (3D) ICBT varied anatomically. Materials and Methods: A total of 50 patients who received 30 Gy of 3D ICBT after external radiotherapy (RT) were enrolled. We compared the doses of the actual 3D and 2D ICBT plans among patients grouped according to six anatomical variations: differences in a small-bowel V2Gy, small bowel circumference, the direction of bladder distension, bladder volume, sigmoid V3.5Gy, and sigmoid circumference. Seven dose parameters were measured in line with the EMBRACE recommendations. Results: In terms of bladder volume, the bladder and small-bowel D2cc values were lower in the 150-250 mL bladder volume subgroup; and the rectum, sigmoid, and bladder D2mL values were all lower in the >250 mL subgroup, for 3D vs. 2D ICBT. In the sigmoid V3.5Gy >2 mL subgroup, the sigmoid and bladder D2mL values were significantly lower for 3D than 2D ICBT. The bladder D2mL value was also significantly lower for 3D ICBT, as reflected by the sigmoid circumference. In patients with a small bowel V2.0Gy >10 mL or small bowel circumference >15%, most dose parameters were significantly lower for 3D than 2D ICBT. The bladder distension direction did not significantly affect the doses. Conclusion: Compared to 2D ICBT, a greater bladder volume can reduce the internal 3D ICBT organ dose without affecting the target dose.

A study on dosimetric comparison of craniospinal irradiation using tomotherpy and reproducibility of position (토모테라피를 이용한 뇌척수조사의 선량적 비교와 자세 재현성에 대한 고찰)

  • Lee, Heejeong;Kim, Jooho;Lee, Sangkyu;Yoon, Jongwon;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: The purpose of this study was to verify dosimetric results and reproducibility of position during craniospinal irradiation (CSI) using tomotherapy (Accuray Incorporated, USA). Also, by comparing with conventional CSI Technique, we confirmed the efficiency of using a Tomotherapy. Materials and Methods: 10 CSI patients who get tomotherapy participate. Patient-specific quality assurances (QA) for each patient are conducted before treatment. When treating, we took Megavoltage Computed Tomography (MVCT) that range of head and neck before treatment, L spine area after treatment. Also we conducted in-vivo dosimetry to check a scalp dose. Finally, we made a 3D conventional radiation therapy(3D-CRT) of those patients to compare dosimetric differences with tomotherapy treatment planning. Results: V107, V95 of brain is 0 %, 97.2 % in tomotherapy, and 0.3 %, 95.1 % in 3D-CRT. In spine, value of V107, V95 is 0.2 %, 18.6 % in tomotherapy and 89.6 %, 69.9 % in 3D-CRT. Except kidney and lung, tomotherapy reduced normal organ doses than 3D-CRT. The maximum positioning error value of X, Y, Z was 10.2 mm, -8.9 mm, -11.9 mm. Through in-vivo dosimetry, the average of scalp dose was 67.8 % of prescription dose. All patient-specific QA were passed by tolerance value. Conclusion: CSI using tomotherapy had a risk of parallel organ such as lung and kidney because of integral dose in low dose area. However, it demonstrated dosimetric superiority at a target and saved normal organ to reduce high dose. Also results of reproducibility were not exceeded margins that estimated treatment planning and invivo dosimetry showed to reduce scalp dose. Therefore, CSI using tomotherapy is considered to efficient method to make up for 3D-CRT.

  • PDF

TTA 시험$cdot$인증 서비스 - 네트워크분야 -

  • 배성용;장웅
    • TTA Journal
    • /
    • s.92
    • /
    • pp.131-137
    • /
    • 2004
  • TTA(한국정보통신기술협회)는 2004년 2월 17일 엔텔테크놀로지㈜(http://www.ntel21.com/) VoIP Gateway(모델명: NT-301)의 기능 및 성능 시험을 수행하여 TTA Verified 인증서(번호: TTA-V-N-04-001)를 발급하였다. 또한 2004년 3월 10일 HS 텔리안㈜(http://www.hsteliann.com/) VoIP Gateway(모델명: Telimax414)의 시험을 수행하여 TTA Verified 인증서(번호: TTA-V-N-04-003)를 발급하였다. 위의 두 장비는 FXS 포트 및 PSTN 백업 포트 그리고 이더넷 포트가 장착된 장비로서, TTA가 위의 두 장비에 대하여 수행한 시험은 기능 확인 및 성능 평가를 측정하는 것이었다. 본 고에서는 TTA가 마련한 소용량 VoIP Gateway에 대한 인증기준(TTA-V-N-03-009-CC12)을 바탕으로 위의 두 장비에 대해 수행한 기능 및 성능 시험결과를 소개한다.

  • PDF