• Title/Summary/Keyword: CC평가

Search Result 423, Processing Time 0.031 seconds

Economic Evaluation for Korea Type of 300 MW IGCC Demonstration Plant Technology Development Project (실물옵션을 활용한 한국형 300 MW급 IGCC 실증플랜트 기술개발사업의 경제성 분석)

  • Eom, Su-Jeong;Nam, Young-Sik
    • Journal of Climate Change Research
    • /
    • v.3 no.4
    • /
    • pp.271-280
    • /
    • 2012
  • The study aims to analyze economic viability of Integrated Gasification Combined Cycle, an innovative technology to utilize clean coal effectively and efficiently in the era of energy crisis. The study is conducted to evaluate business value of 300 MW IGCC demonstration plant technology development based on binomial option, in consideration of uncertainty of fuel price. Binomial option is one of the real option valuation methods, which is ideally suited to irreversible decision making under uncertainty. With this analysis, it shows that investment value is higher compared with economic evaluation based on discounted cash flow, since this method can measure quantity. As a result, this study is proved to be economically feasible, which have a positive impact on the next generation of IGCC and the connection with Carbon Capture and Storage.

Asbestos Exposure and Health Risk Assessment for the Residents Near the Abandoned Mining Area in Chungbuk, Korea (충북지역 폐석면광산 인근주민의 석면노출과 건강위해도 평가)

  • Shin, Jin-Ho;Oh, Seok-Ryul;Hwang, Soon-Yong;Chung, Sook-Nye;Kim, Ji-Hui;Nam, Eun-Jung;Lee, Jin-Hyo;Choi, Hee-Jin;Eom, Seok-Won;Chae, Young-Zoo;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.345-350
    • /
    • 2012
  • To investigate the exposure and health risk assessment for the residents near the D-asbestos mine in Chungbuk, Korea. We analyzed asbestos in the 20 ambient air and 23 activity based samples near the mine. The airborne sample results are showed that 8 of 20 samples ranged between 0.0025 to 0.0029 f/cc (fiber per cubic centimeter) and the others were below the detection limit by phase contrast microscopy (PCM). In addition, asbestos fibers were under the detection limit or not being by transmission electron microscopy (TEM). Based on interview and survey targeting the local residents, we made the activity based sampling (ABS) scenarios fit to the conditions of field. At the same time, we calculated the excess lifetime cancer risk (ELCR) of these ABS scenarios according to the ELCR average value and 95% upper confidence limit (UCL). At the case of weed whacking, soil digging and sweeping yard scenario, 95% UCL of ELCR exceeded the $1{\times}10^{-4}$, acceptable risk range for exposure. Based on our study results, it is necessary safety measures such as risk communication, abatement or management of naturally occurring asbestos (NOA).

An Experimental Evaluation of AEB Equipped Passenger Vehicle for the Pedestrian Collision Situations (AEB 장착 승용차의 보행자 충돌상황에 관한 실험적 평가에 관한 연구)

  • Shim, Jaekwi;Lee, Sangsoo;Sun, Chisung;Nam, Doohee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.202-210
    • /
    • 2019
  • This paper evaluated the performance of passenger vehicles with an AEB(Autonomous Emergency Braking) for various pedestrian-vehicle collision situations. The experiment was conducted at a speed of 30-60km/h on a 2017 3,000cc vehicle using a range of collision scenarios. The results showed that the test vehicle stopped before crashing a pedestrian dummy under all scenarios at 30km/h. The test vehicle reduced the speed but crashed the pedestrian dummy in all scenarios at 40-60km/h. From the paired t-test, there was a speed difference from the AEB system at a significant level of 0.05. In addition, the percentage of speed reduction was quite different for each scenario tested. It was concluded that the current AEB system can prevent pedestrian collisions at speed of 30km/h, but cannot prevent collisions with pedestrians at speed of 40-60 km/h.

Calibration of Discharge Coefficient of Sonic Nozzle Using CVFM (정적형 유량계를 이용한 소닉노즐 유출계수 교정 방법에 관한 연구)

  • Shin, J.H.;Kang, S.B.;Park, K.A.;Lim, J.Y.;Cheung, W.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.243-248
    • /
    • 2010
  • Sonic nozzles have been a standard device for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two sonic nozzles of diameter ${\Phi}$ 0.03 mm and ${\Phi}$ 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter(CVFM), readily set up in the Vacuum center of KRISS. was used to calibrate the discharge coefficients of both nozzles. The calibration results were shown to determine them within the 3% expanded measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process in the ranges of 0.6~1,800 cc/min. Those flow conditions are equivalent to the fine gas flow with Reynolds numbers of 26~12,100. Those encouraging results confirm that calibrated sonic nozzles enable precision measurement of extremely low gas flow encountered very often in th vacuum processes. Both calibrated sonic nozzles are proven to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of vacuum pumps in the semiconductor and flat display processes. Furthermore, they can provide other applications to flow control devices in vacuum, such as MFC, etc.

Novel two-stage hybrid paradigm combining data pre-processing approaches to predict biochemical oxygen demand concentration (생물화학적 산소요구량 농도예측을 위하여 데이터 전처리 접근법을 결합한 새로운 이단계 하이브리드 패러다임)

  • Kim, Sungwon;Seo, Youngmin;Zakhrouf, Mousaab;Malik, Anurag
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1037-1051
    • /
    • 2021
  • Biochemical oxygen demand (BOD) concentration, one of important water quality indicators, is treated as the measuring item for the ecological chapter in lakes and rivers. This investigation employed novel two-stage hybrid paradigm (i.e., wavelet-based gated recurrent unit, wavelet-based generalized regression neural networks, and wavelet-based random forests) to predict BOD concentration in the Dosan and Hwangji stations, South Korea. These models were assessed with the corresponding independent models (i.e., gated recurrent unit, generalized regression neural networks, and random forests). Diverse water quality and quantity indicators were implemented for developing independent and two-stage hybrid models based on several input combinations (i.e., Divisions 1-5). The addressed models were evaluated using three statistical indices including the root mean square error (RMSE), Nash-Sutcliffe efficiency (NSE), and correlation coefficient (CC). It can be found from results that the two-stage hybrid models cannot always enhance the predictive precision of independent models confidently. Results showed that the DWT-RF5 (RMSE = 0.108 mg/L) model provided more accurate prediction of BOD concentration compared to other optimal models in Dosan station, and the DWT-GRNN4 (RMSE = 0.132 mg/L) model was the best for predicting BOD concentration in Hwangji station, South Korea.

Fluid Structure Interaction Analysis of Membrane Type LNG CCS Experiencing the Sloshing Impact by Impinging Jet Model (멤브레인형 LNG 화물창의 강도평가를 위해 적용된 분사모델을 이용한 유체구조 연성해석에 관한 연구)

  • Hwang, Se Yun;Lee, Jang Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.71-78
    • /
    • 2015
  • The reliable sloshing assessment methods for LNG CCS(cargo containment system) are important to satisfy the structural strength of the systems. Multiphase fluid flow of LNG and Gas Compressibility may have a large effect on excited pressures and structural response. Impinging jet model has been introduced to simulate the impact of the LNG sloshing and analyze structural response of LNG CCS as a practical FSI(fluid structure interaction) method. The practical method based on fluid structure interaction analysis is employed in order to evaluate the structural strength in actual scale for Mark III CCS. The numerical model is based on an Euler model that employs the CVFEM(control volume based finite element method). It includes the particle motion of gas to simulate not only the interphase interaction between LNG liquid and gas and the impact load on the LNG insulation box. The analysis results by proposed method are evaluated and discussed for an effectiveness of FSI analysis method.

Mechanical Characteristics of Dredged and Reclaimed Ground with Low Plasticity from Western Coastal Site (서해안 저소성 준설매립 지반의 역학적 특성)

  • Jeong, Sang Guk
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.97-104
    • /
    • 2015
  • When carrying out design for soft ground improvement before reclamation of dredged soil, it is very important to appropriately evaluate design parameters such as compression index and undrained strength in order to estimate optimum construction cost. In this study, consolidation and strength parameters were estimated by the samples obtained from the similar reclaimed land. Water content and compression index of dredged soil reclaimed by hydraulic fill method were quite decreased in comparison with those of in-situ conditions at Incheon site. Relationships between compression index(Cc) and water content (wn), and between undrained strength (su) and water content (wn) for dredged soil were obtained by field vane test and oedometer test, respectively. Applicability of Schmertmann correction method (compression index) for low plasticity silty soil was discussed according to comparison with designed and measured settlements.

Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement (저전도율 유체 측정에서 소형 전자기유량계의 신호 특성)

  • Lim, Ki Won;Jung, Sung Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.613-620
    • /
    • 2016
  • In order to scrutinize the fluid conductivity effects on the electromagnetic flowmeter(EMF) characteristics, a small scale EMF was designed and fabricated. The measuring tube has a $3mm{\times}4mm$ rectangular cross-section, 9 mm length, and a $2mm{\times}3mm$ plate electrode and a ${\Phi}1.5mm$ point electrode. The design parameters, such as the magnetizing frequency and the number of coil turns, and the diameter were optimized. The EMF was tested with a gravimetric calibrator and showed good linearity in the range of 0 to $1.17{\times}10^{-5}m^3/s$. The fluid conductivity was varied between 3 and $11{\mu}S/cm$, and the magnitude of the flow signal was proportional to the fluid conductivity and the wetted area of the electrode. The design information and the test results provide flow measurement techniques for very low flowrate.

Corrosion and Mechanical characteristics for 9Cr-1MoVNb Steel under SO2 gas environment (SO2 가스 환경 하에서 9Cr 템퍼드-마르텐사이트강의 부식 및 기계적 특성)

  • Jeong, Gwang-Hu;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.109-109
    • /
    • 2018
  • Cr-Mo 합금강은 고온 환경 하에서 높은 크리이프 강도와 우수한 내식성 때문에 발전설비, 석유 화학, 그리고 해양산업과 같은 여러 산업분야에서 널리 사용되고 있다. 특히, Cr-Mo 강의 내식성은 합금 내 Cr 함량에 크게 의존한다. 이는 고온에서 Cr과 O가 화학적 반응을 일으킴에 따라 보호성의 Cr 산화스케일을 형성하기 때문이다. 그러나 화석연료를 사용하는 발전설비의 경우, $SO_2$가 포함된 강한 부식성의 연소 가스가 배출되며, 이에 노출된 금속의 표면에서는 산화와 황화가 동시에 발생한다. 황화스케일은 산화스케일에 비해 매우 빠르게 성장하며, 그 특성이 매우 취약하기 때문에 황화 환경에서 금속의 내식성 및 기계적 물성치는 보다 크게 저하된다. 따라서 본 연구에서는 화력 발전소의 증기발생용 튜브 재료인 9Cr-1MoVNb 강을 선정하였으며, $SO_2$ 가스 환경 하에서의 부식 및 기계적 물성치 저하 특성을 평가하고자 하였다. 본 연구에서 사용된 9Cr-1MoVNb강의 화학 성분 조성은 0.1 C, 0.38 Si, 0.46 Mn, 0.25 Ni, 8.38 Cr, 0.93 Mo, 0.18 V, 0.09 Nb, 그리고 나머지는 Fe이다. 부식시험은 가공된 미소시험편과 인장시험편을 전기열처리로에 장입한 후, $650^{\circ}C$에서 $N_2+O_2+O_2+SO_2$ 조성의 가스를 분당 50 CC로 흘려주었다. 제작된 시험편에 대한 부식거동은 무게 증가량, optical microscope, scanning electron microsope, 그리고 energy dispersive x-ray spectrum을 통해 평가하였다. 그리고 기계적 물성치 평가를 위한 인장시험은 분당 2mm 변위제어를 통해 실시하였다. 그 결과, 9Cr-1MoVNb 강은 $SO_2$ 가스 환경 하에서 비 보호적인 Fe-풍부상의 산화 스케일층이 두껍게 형성됨에 따라 열악한 내식성을 나타냈다. 그에 따라 기계적 물성치는 저하되는 경향을 나타내었다.

  • PDF

Evaluation of Land Use Change Impact on Stream Drying Phenomena Using a Grid-Based Continuous Hydrologic Model (격자기반 수문 모델을 이용한 토지이용변화에 따른 하천건천화 영향 평가)

  • Jung, Chung Gil;Lee, Yong Gwan;Jang, Sun Sook;Kim, Seong Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.102-102
    • /
    • 2015
  • 최근 중소규모 하천은 하천수 및 하천변 지하수 이용의 증가와 토지이용변화 등 유역 내 수문인자의 특성 변화로 인해 하천의 건천화가 점증하고 있어 하천 환경이 악화되고 있는 실정이다. 본 연구에서는 격자기반의 분포형 장기수문 모델(PGA-CC)을 이용하여 과거 수십년동안 토지이용변화에 따른 하천 건천화 영향을 평가하였다. 실제 건천화가 진행되고 있는 삽교천 상류유역($358.8km^2$)을 선정하였고 토지이용변화분석을 위해 과거 1975년 토지이용도(Past), 현재 2008년 토지이용도(Present)를 구축하였다. 각각의 토지이용 항목 중 변화율이 가장 높은 도시비율은 과거 토지이용도에서는 2.6 %였으며 현재 토지이용도에서는 11.3 %로 8.7 %가 증가하였다. 모델 검보정은 최근 7년(2005-2011)동안 최종유역출구지점에서 유출 검보정을 실시하였다. 그 결과 NSE (Nash-Sutcliffe model efficiency)은 평균 0.71로 유출량의 모의값과 실측값이 유효한 것으로 나타났다. 건천화를 평가하기 위해 시험유역에서의 5 WPs (Watching Points)를 선정하여 과거 및 현재 토지이용조건을 모의하고 유황분석을 통한 갈수 변화량 분석을 실시하였다. 건천화 빈도분석을 위해 GEV (Generalized Extreme Value) 갈수빈도분석을 실시하여 과거 토지이용 모의결과 산정된 평균 갈수량($m^3/s$) 이하로 낮아지는 유출량 일수를 계산하였다. 최종유역출구에서 과거 및 현재 토지이용도에서 모의된 평균갈수량은 각각 $3.27m^3/s$$3.11m^3/s$로 나타났다. GEV 갈수빈도분석결과 과거 토지이용조건에서의 평균갈수량은 $3.20m^3/s$(재현기간 2.33년)으로 나타났다. 도시증가에 따른 인구증가는 지하수 사용량에 증가를 가져온다. 이는, 건천화에 영향을 미치며 본 연구에서는 지하수이용량 자료(1998-2011)를 이용하여 도시면적과 지하수이용량의 선형회귀분석을 실시하여 과거 22년 지하수 사용량을 예측하였다. 그 결과 지하수사용량 증가는 토지이용변화와 복합적으로 상류유역에 하천의 변화를 가속시키는 것으로 나타냈다.

  • PDF