• Title/Summary/Keyword: CC평가

Search Result 421, Processing Time 0.025 seconds

Development of Security Metric of Network Access Control (네트워크 접근제어 시스템의 보안성 메트릭 개발)

  • Lee, Ha-Yong;Yang, Hyo-Sik
    • Journal of Digital Convergence
    • /
    • v.15 no.6
    • /
    • pp.219-227
    • /
    • 2017
  • Network access control should be able to effectively block security threats to the IT infrastructure, such as unauthorized access of unauthorized users and terminals, and illegal access of employees to internal servers. From this perspective, it is necessary to build metrics based on relevant standards to ensure that security is being met. Therefore, it is necessary to organize the method for security evaluation of NAC according to the related standards. Therefore, this study builds a model that combines the security evaluation part of ISO / IEC 15408 (CC: Common Criteria) and ISO 25000 series to develop security metric of network access control system. For this purpose, we analyzed the quality requirements of the network access control system and developed the convergence evaluation metric for security of the two international standards. It can be applied to standardization of evaluation method for network access control system in the future by constructing evaluation model of security quality level of network access control system.

Evaluation of the Biocompatibility of Cuttlebone in Mouse (쥐에서 오적골 생체적합성 평가)

  • Won, Sangcheol;Lee, Joo Myoung;Cheong, Jongtae;Park, Hyunjung;Seo, Jongpil
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.417-421
    • /
    • 2015
  • Bone grafting is widely used to bridge major bone defects or to promote bone union. Natural calcium carbonate (CC) has been used as a bone substitute material and used to scaffold for bone morphogenetic protein (BMP). The aims of this study is to evaluate the biocompatibility of cuttlebone (CB) and hydroxyapatite from CB (CBHA). Each material was shaped into disks (5 mm in diameter and 2 mm in thickness). To test biocompatibility, the disks were implanted into the dorsal subcutaneous tissue in mice. Fibrous capsule thickness around each disk was evaluated histologically at 2 and 4 weeks after implantation. Concerning biocompatibility, fibrous capsule thickness of CBHA was significantly thinner than that of CB and CHA (p < 0.05) at 2 and 4 weeks after implantation. Based on the clinical and histological results, CBHA would be a safe material for use inside the body and has more effective osteoconduction than CB.

국내 평가.인증 정책의 현황 및 향후 추진방향

  • Lee, Dae-Seob;Hong, Won-Soon
    • Review of KIISC
    • /
    • v.17 no.6
    • /
    • pp.20-24
    • /
    • 2007
  • 정보보호제품의 안전성 및 신뢰성이 검증된 제품의 공급 및 이용 촉진을 위해 운영되고 있는 정보보호제품 CC 인증제도, 암호제품에 대한 암호 검증제도, 공공기관 도입 정보보호제품에 대한 보안적합성 검증제도 등에 대한 현황 및 향후 추진방향을 살펴본다.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

Characterization and Evaluation of Worker s Exposure to Airborne Glass Fibers in Glass Wool Manufacturing Industry (유리섬유 단열재 제조업 근로자의 공기중 유리섬유 폭로 특성 및 평가 방법에 관한 연구)

  • 신용철;이광용;박천재;이나루;정동인;오세민
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.43-57
    • /
    • 1996
  • To characterize worker's exposure to glass fibers, to find the correlation between airborne total dust concentrations and fiber concentrations and to recommend an appropriate evaluation method for worker's exposure to fibrous dusts in glass wool industry, we carried out this study. Average respirable fiber levels at five factories were 0.013-0.056 f/cc, and fairly below the OSHA PEL, 1 f/cc. A factory showed the lowest airborne fiber level, 0.013 f/cc, which was different significantly from those of other factories of which average fiber concentration was 0.046 f/cc. The cutting and grinding operations of insulation products resulted in higher airborne fiber cocentrations than any other processes(p<0.05). To characterize airborne fiber dimension, fiber length and diamter were determined using phase contrast microscope. The geometric means of airborne fiber lengths were $42-105 \mu m$. One factory had airborne fibers whose length distribution(GM = $105 \mu m$) was different from those of other factories(GM = $42-50 \mu m$). The percentages of respirable fibers less thinner than 3 gm were 38.9-90.9% at four factories, and two factories of them had the higher percentages than others. The findings explain for variation of airborne fiber diameters between factories. On the other hand, between the processes were the difference of fiber-length distributions observed. The cutting and grinding operations showed shorter fiber-length distributions than the fiber forming one. However, fiber-diameter distributions or respirable fiber contents were similar in all processes. The airborne fiber concentrations and the dust concentrations had relatively weak correlation(r=0.25), thus number of fibers couldn't be expected reliably from dust amount. Fiber count is appropriate for assessing accurate exposures and health effects caused by fibrous dusts including glass fibers. Ministry of Labor have established occupational exposure limit to glass fibers as nuisiance dust, but should establish it on the basis of respirable fiber concentration to provide adequate protection for worker's health

  • PDF

Integrated Management System of Profile Based on CC/PP for Supporting Content Adaptation Services (콘텐츠 적응화 서비스 지원을 위한 CC/PP기반의 프로파일 통합 관리 시스템)

  • Kim, Kyung-Sik;Lee, Jae-Dong
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.8
    • /
    • pp.1078-1091
    • /
    • 2007
  • This paper proposes the system to manage profiles effectively that are necessary for content adaptation services. The proposed profiles for providing content adaptation services are used in the various services. However, currently, there are lack of the interoperability in profiles due to the different configuration, which is affected by different services. The service providers also spend a lot of operating costs by operating profiles respectively. To solve theses problems, the system which can integrate and manage the various kinds of the profiles is necessary. Based on profile services architecture and the previous profile research to the necessary functions for the proposed integrated management system of profile are derived. The proposed integrated management system of profile supports also the functions such as receiving, processing, saying, managing, providing and supports profiles that are made of RDF form and comply with the CC/PP specification. The metadata constitution technique and dynamic technique for effective content adaptation also are applied. As a result of performance evaluation the proposed techniques improve the performance 4% compared with the previous techniques.

  • PDF

Design and Implementation of a Systolic Architecture for Low Power Wireless Sensor Network (저 전력 무선 센서 네트워크를 위한 시스톨릭 구조 설계 및 구현)

  • Lee, Kyung-Hoon;Lee, Hak-Jai;Kim, Young-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.6
    • /
    • pp.749-756
    • /
    • 2015
  • In this paper, we propose a unique systolic structure and communication algorithm that maintains a solid link between nodes using synchronous digital communication and enables low power communication. This system was designed by using CC2500 RF transceiver, CC2590 RF front end and C8051F330 low power microcontroller. The measurement of power consumption in the network link shows below $400{\mu}W$ in data transfer rate 320bps. The system constitutes the base unit of low power wireless network that was composed of each seven link nodes having eight sensor nodes. Results of the experiments show that link nodes using a 4Ah battery could operate over 3 years without replacement.

Evaluation of the quality of Danhopak tzeam prepared with the Sous vide Cook-Chill System and Conventional Cook-Chill System (Sous vide Cook-Chill System과 Conventional Cook-Chill System으로 생산된 단호박찜의 미생물적 품질평가)

  • Ko, Sung-Hee;Kim, Heh-Young;Oh, Kyung-Sook
    • Korean journal of food and cookery science
    • /
    • v.22 no.4 s.94
    • /
    • pp.504-513
    • /
    • 2006
  • This study was performed to provide basic data for the operation of a safer cook-chill system by comparing and evaluating the quality of food prepared using the sous vide cook-chill(SVCC) and cook-chill(CC) systems, according to the preparation methods and storage temperature. When the effects of preparation methods and storage temperatures on the physicochemical and microbial qualities were analyzed, the following results were obtained. Firstly, the microbial risk was reduced and the food was raised when danhopark tzeam were prepared with SVCC compared with CC in which changes in pH and Aw and moisture content loss were less than with SVCC. Secondly, the storage period tested in this study was limited to only 10 days, which prevented any significant difference from being seen at 3$^{\circ}$C and 10$^{\circ}$C in the degradation of food quality when SVCC and CC were compared. However, the overall quality and safety as indicated by the physicochemical and microbial qualities at 10$^{\circ}$C were relatively low for and with CC, suggesting that SVCC is a more effective method, probably because vacuum packing eliminates oxygen in the food, thereby inhibiting bacterial growth.

An Objective Performance Analysis of Crosstalk Cancellation Scheme for Sound Rendering Systems Based on Listener Position Tracking (청취자 위치정보 기반 Sound Rendering 시스템 상호간섭 제거기법의 객관적 성능분석)

  • Lee, Jung-Hyuck;Kim, Yeong-Moon;Yoo, Seung-Soo;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2C
    • /
    • pp.112-118
    • /
    • 2011
  • In this paper, we conduct an objective performance analysis of the crosstalk cancellation scheme studied in [11]. While the conventional scheme is only applicable to a listener on the optimal listenable region (sweetspot), the space skew/crosstalk cancellation (SS/CC) scheme in [11] can mitigate crosstalk regardless of the listener's position by using listener position tracking (LPT) system. The SS/CC scheme is composed of two parts: LPT-based SS and CC parts. In this paper, the SS/CC scheme is evaluated by some criteria such as follows: condition number, and the balance characteristic, its root mean square error, and running average.

A Study on the Prediction of the Surface Drifter Trajectories in the Korean Strait (대한해협에서 표층 뜰개 이동 예측 연구)

  • Ha, Seung Yun;Yoon, Han-Sam;Kim, Young-Taeg
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • In order to improve the accuracy of particle tracking prediction techniques near the Korean Strait, this study compared and analyzed a particle tracking model based on a seawater flow numerical model and a machine learning based on a particle tracking model using field observation data. The data used in the study were the surface drifter buoy movement trajectory data observed in the Korea Strait, prediction data by machine learning (linear regression, decision tree) using the tide and wind data from three observation stations (Gageo Island, Geoje Island, Gyoboncho), and prediciton data by numerical models (ROMS, MOHID). The above three data were compared through three error evaluation methods (Correlation Coefficient (CC), Root Mean Square Errors (RMSE), and Normalized Cumulative Lagrangian Separation (NCLS)). As a final result, the decision tree model had the best prediction accuracy in CC and RMSE, and the MOHID model had the best prediction results in NCLS.