• Title/Summary/Keyword: CAN Bus

Search Result 1,326, Processing Time 0.024 seconds

The Comparison of Two Control Algorithm for a Voltage Bus Conditioner in a DC Power Distribution System (DC 전력시스템에서의 Voltage Bus Conditioner의 제어기법 비교)

  • La, Jae-Du;Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • A Voltage Bus Conditioner (VBC) is used to mitigate the voltage transients on a common power distribution bus. The VBC described here utilises inductive storage and unlike its counter part with capacitive storage, it can employ the entire stored energy towards transients' mitigation. The performances of adaptive duty ratio control and sliding mode control have been compared. The simulation results (with the package SABER) indicate that the sliding mode control results in the shortest and the smallest bus voltage excursions.

IoT Bus System for Passenger Safety and Convenience Service Improvement (승객 안전과 편의 서비스 개선을 위한 IoT 버스 시스템)

  • Heo, Seong Su;Heo, Tae Sung;Park, Yoo Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.10
    • /
    • pp.1203-1210
    • /
    • 2018
  • As the use of public transportation is increasing, a service considering the convenience of passengers is being launched utilizing the Internet (IoT) data collected through the bus information system. However, the bus information system only provides limited information such as the current location of the bus (GPS) and the expected arrival time at the stop. Additional IoT sensor information is needed to provide various services for the safety and convenience of passengers. In this paper, to improve the safety and convenience of passengers, we have added the boarding doors imaging sensor, temperature and humidity sensors, and sensor for measuring the number of passengers. The proposed IoT bus system can attach various sensors to buses to provide high-quality safety services to passengers.

Load Center Concept Equivalent by T/L Loss Identification (부하 중심점 개념의 전력 시스템 정태 등가 축약)

  • Baek, Soo-Youl;Kim, Jung-Hun;Shim, Keon-Bo;Lee, Bong-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.149-152
    • /
    • 1992
  • A simple and practial equivalent technique has been presented in this study. Arbitrary number of bus system can be aggregated to the equivalent one-bus system, equivalents are totel real, and reactive bus powers and T/L losses viewing form boundary buses. Variables to be determined are line impedance between boundary buses and the equivalent bus, voltage and angle of that bus. IEEE 14 bus system is used to demonstrate the proposed method. even in contingency cases very good results have been obtained

  • PDF

On Installation of Bus Trunk System for Wind Tower (풍력타워용 부스닥트 포설시스템 개발)

  • Lee, Joon-Keun;Kim, Bong-Seok;Park, Seong-Hee;Ahn, Hyung-Joon;Lee, Hee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.330-335
    • /
    • 2012
  • A Bus Trunk System for Wind Tower is introduced. A marine cable has been widely used in wind tower or other offshore structure. However, as the electric load capacity is getting increased, the large number of cable lines should be used to cover such a huge amount of electric capacities, which makes the installation make quite difficult due to the heavy weight and volume of the present cables. On the other hand, by using a single bus trunk system line, the power capacity amount of 16 number of cable can be delivered with significant compactness. However, unlike flexible cable, the bus trunk is relatively stiff which could arise resonance phenomenon in the operating condition of wind tower, therefore, the vibration characteristics of bus trunk should be investigated and verify its long-term reliability during the life time of the wind tower.

  • PDF

An Improved Adaptive Control Technique for the Voltage Bus Conditioner with the Reduced Capacitive Storage (축소된 캐패시터 스토리지를 갖는 Voltage Bus Conditioner의 향상된 적응제어)

  • La, Jae-Du;Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.13-18
    • /
    • 2011
  • More and all-electric aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, a converter with spilt capacitors and an improved adaptive controller is used as the Voltage Bus Conditioner (VBC) with the reduced capacitive storage to mitigate the voltage transients on the bus. The proposed converter allows the smaller capacitive storage. Also, the proposed controller has the advantage of requiring only one sensor and performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. Experimental results are presented which verify the control principles and demonstrate the practicality of the approach.

Current Sensorless Control of the Voltage Bus Conditioner for a DC Power System with Parallel Pulsed Power Loads (병렬 펄스 부하를 갖는 직류 전력시스템을 위한 Voltage Bus Conditioner의 전류 센서 없는 제어)

  • Lee, Byung-Hun;Chang, Han-Sol;La, Jae-Du;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1617-1624
    • /
    • 2012
  • A DC power system has many loads with varied functions. Also, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, Voltage Bus Conditioner(VBC) without any current sensors is proposed to damp the bus voltage transients by parallel pulsed loads. The proposed control approach requires only one voltage sensor and carries out both the functions of damping the bus voltage transients and maintaining the level of energy stored. The proposed control technique has been implemented on a TMS320F2812 Digital Signal Processor(DSP). Simulated results by a Matlab Simulink and experimental results are presented which verify the control principles and demonstrate the practicalty of the approach.

Configuration of Actuator and Sensor Interface Bus Network using PLC

  • Luu, Hoang-Minh;Park, Young-San
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.3
    • /
    • pp.318-322
    • /
    • 2014
  • A kind of field bus called Actuator and Sensor interface bus(AS-i) was designed in this paper. The configuration of AS-i network system used Application Specific Integrated Circuit(ASIC) SAP5S chip and PLC S7-200 station, which included CPU 224 and AS-i master module CP 243-2. We also created an example program for PLC S7-200 to control AS-i network. The fire and smoke detection system was made with AS-i network system that was designed. This system had got more advantages than other system such as number of stations, easy installation, wide working area, etc. And designed system can be used as a partner network for higher level field bus networks.

An improvement strategy of metropolitan commuter railways according to the reformation of bus system on a metropolitan area (대도시권 버스개편추세에 따른 통근전철의 대응 전략)

  • Han Woo-jin
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1601-1606
    • /
    • 2004
  • Nowadays, the bus system of a metropolitan area is improving very fast. According to the bus, commuter railways increase their competitive power. For this, trains get the mobility increasing, effective transferring system and unified information service. For the mobility increasing, commuting railway must be faster by flexible train diagram and facilities improvement. And finally, optimal commuter train, 'Liner' is needful. And for effective transferring system, it is necessary that railway station and transferring center of a city be merged. And it is needful that direct management bus by railway company and unification fare system on metropolitan region. Next, for information service system improving, the commuting railway station must be regional transportation hub at first. And it is needful that unified line map of trunk line transportation systems and regionally collective transportation system information book. Therefore, metropolitan commuting railways compete with trunk line bus and cooperate with feeder line bus, and can make optimal metropolitan public transportation systems.

  • PDF

A New Calculation of Generator Penality Factors through transposition of System Angle Reference (위상각기준의 이동을 통한 새로운 패널티 계수의 계산방법)

  • Lee, Sang-Joong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • In this paper, a new method for calculating the penalty factors of all generators including the slack bus is presented. A simple transposition of the angle reference, from the conventional slack bus to another bus where no generation exists, enables the derivation of the loss sensitivity of the slack bus. Penalty factors are obtained without any physical assumption through a simple substitution of the bus loss sensitivities. Penalty factors calculated by proposed method are not dependent on reference bus and can also be directly substituted into the general ELD equation for computing the optimal dispatch. Equations for loss sensitivities, Penalty factors and ELD are calculated simultaneously in normal power flow computation. A case study on a test system has proved the effectiveness of the proposed' angle reference transposition' method.

  • PDF

Application of Neural Networks to the Bus Separation in a Substation (신경회로망을 이용한 변전소 모선분리 방안 연구)

  • Lee, K.H.;Hwang, S.Y.;Choo, J.B.;Youn, Y.B.;Jeon, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.757-759
    • /
    • 1996
  • This paper proposes an application of artificial neural networks to the bus-bar separation in a substation for radial network operation. For the effective bus-bar operation, the insecurity index of transmission line load is introduced. For the radial network operation. the constraints of bus-bar switch is formulated in the performance function with the insecurity index. The determination of bus-bar switching is to find the states of 0 or 1 in the circuit breakers. In this paper, it is tested that the bus-bar separation of binary optimization problem can be solved by Hopfield networks with adequate manipulations.

  • PDF