• Title/Summary/Keyword: CAM Software

Search Result 283, Processing Time 0.026 seconds

Surface Type Detection and Parameter Estimation in Point Cloud by Using Orthogonal Distance Fitting (최단거리 최소제곱법을 이용한 측정점군으로부터의 곡면 자동탐색)

  • Ahn, Sung-Joon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.1
    • /
    • pp.10-17
    • /
    • 2009
  • Surface detection and parameter estimation in point cloud is a relevant subject in CAD/CAM, reverse engineering, computer vision, coordinate metrology and digital factory. In this paper we present a software for a fully automatic surface detection and parameter estimation in unordered, incomplete and error-contaminated point cloud with a large number of data points. The software consists of three algorithmic modules each for object identification, point segmentation, and model fitting, which work interactively. Our newly developed algorithms for orthogonal distance fitting(ODF) play a fundamental role in each of the three modules. The ODF algorithms estimate the model parameters by minimizing the square sum of the shortest distances between the model feature and the measurement points. We demonstrate the performance of the software on a variety of point clouds generated by laser radar, computer tomography, and stripe-projection method.

Product data model for PLM system

  • Li, Yumei;Wan, Li;Xiong, Tifan
    • International Journal of CAD/CAM
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Product lifecycle management (PLM) is a new business strategy for enterprise's product R&D. A PLM system holds and maintaining the integrity of the product data produced throughout its entire lifecycle. There is, therefore, a need to build a safe and effective product data model to support PLM system. The paper proposes a domain-based product data model for PLM. The domain modeling method is introduced, including the domain concept and its defining standard along the product evolution process. The product data model in every domain is explained, and the mapping rules among these models are discussed. Mapped successively among these models, product data can be successfully realized the dynamic evolution and the historical traceability in PLM system.

  • PDF

Total joint reconstruction using computer-assisted surgery with stock prostheses for a patient with bilateral TMJ ankylosis

  • Rhee, Seung-Hyun;Baek, Seung-Hak;Park, Sang-Hun;Kim, Jong-Cheol;Jeong, Chun-Gi;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.41.1-41.6
    • /
    • 2019
  • Backgrounds: The purpose of this study is to discuss the total joint reconstruction surgery for a patient with recurrent ankylosis in bilateral temporomandibular joints (TMJs) using three-dimensional (3D) virtual surgical planning, computer-aided manufacturing (CAD/CAM)-fabricated surgical guides, and stock TMJ prostheses. Case presentation: A 66-year-old female patient, who had a history of multiple TMJ surgeries, complained of severe difficulty in eating and trismus. The 3D virtual surgery was performed with a virtual surgery software (FACEGIDE, MegaGen implant, Daegu, South Korea). After confirmation of the location of the upper margin for resection of the root of the zygoma and the lower margin for resection of the ankylosed condyle, and the position of the fossa and condyle components of stock TMJ prosthesis (Biomet, Jacksonville, FL, USA), the surgical guides were fabricated with CAD/CAM technology. Under general anesthesia, osteotomy and placement of the stock TMJ prosthesis (Biomet) were carried out according to the surgical planning. At 2 months after the operation, the patient was able to open her mouth up to 30 mm without complication. Conclusion: For a patient who has recurrent ankylosis in bilateral TMJs, total joint reconstruction surgery using 3D virtual surgical planning, CAD/CAM-fabricated surgical guides, and stock TMJ prostheses may be an effective surgical treatment option.

Fixed Prosthetic Restoration in an Edentulous Patient with NobelGuideTM System (양악 무치악 환자에서 NobelGuideTM 시스템을 이용한 고정성 임플란트 보철수복)

  • Shin, Hyoung-Joo;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.243-253
    • /
    • 2009
  • This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.

Nursing Students' Subjectivity of Complementary and Alternative Medicine (보완대체의학에 대한 간호학과 학생의 주관성 연구)

  • Park, Eun-Young;Lee, Eun-Nam;Kang, Ji-Yeon;Ju, Hyeon-Ok;Kim, Sam-Sook;Choi, Eun-Jung;Kim, Hack-Sun
    • Journal of East-West Nursing Research
    • /
    • v.17 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: The purpose of this study was to grasp the subjectivity of the nursing students toward CAM and put the outcomes into use as basic facts and figures in developing and applying a curriculum associated with CAM. Methods: Q methodology was employed to explore the nursing students' subjectivity from their rank-order statements. For the Q population, individual in-depth interviews and literature research were conducted. Finally, 30 participants completed 40 Q statements. The data were analyzed using the QUANL software package. Results: The current survey that probed into the subjectivity of the nursing students relative to CAM abstracted four categories, namely, practical and convinced type, keep-under-control/wait-and-see type, merit acknowledging type and limitedly accepting type. Conclusion: It is recommended that various educational programs should be developed to shift the awareness of CAM on the part of the nursing students, based on the findings set forth in the current study.

A Study on the Optimum Clearance Selection of Fuel Pump Journal Bearing with Elasto-hydrodynamic Lubrication Analysis (탄성유체윤활해석에 의한 연료 펌프 저널베어링 최적간극 선정 연구)

  • An, Sung Chan;Lee, Sang Don;Son, Jung Ho;Cho, Yong Joo
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • The electric controlled marine diesel engine has fuel pump generating the high pressurized fuel for fuel injection to combustion chamber via a common rail. Fuel pump consists of a cam-roller system. Journal bearing installed between a roller and a cam-roller pin is subjected to fluctuating heavy and instant loads by cam lift. First, Kinematic analysis is carried out to predict bearing loads during one cycle acting on the journal bearing. Second, flexible multi-body dynamic analysis and transient elasto-hydrodynamic(EHD) lubrication analysis for journal bearing considering elastic deformation of cam-roller pin, roller and bearing are conducted using AVL EXCITE/PU software to predict lubrication performance. The clearance ratio and journal groove shape providing lubrication oil are important parameter in bearing design having good performance and can be changed easier than other design parameters such as diameter, width, oil supply pressure and bearing material grade. Generally, journal bearing performance is represented by the minimum oil film thickness(MOFT) and peak oil film pressure(POFP). As well as the traditional design parameters(MOFT, POFP), in this study, temperature rise of lubrication oil is also evaluated through the side leakage flow of supplied oil. By the evaluating MOFT, POFP and temperature rise, the optimum bearing clearance ratio is decided.

Development of Advanced Rendering Library for CAD/CAM Moduler (CAD/CAM 모델러용 고급 렌더링 라이브러리의 개발)

  • Choe, Hun-Gyu;Lee, Tae-Hyeon;Han, Hun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.5 no.4
    • /
    • pp.385-394
    • /
    • 1999
  • 제품을 설계하는 디자이너나 엔지니어는 많은 시간과 노력을 들이지 않고서 그들이 설계한 3차원 제품 모델에 대한 사실적인 이미지를 원한다. 디자인 프로세스의 초기인 개념 설계에서부터 설계검증, 그리고 가공 과정에서 사실적인 이미지가 매우 유용하므로, 대부분의 주요 CAD 제작사는 그들의 CAD 소프트웨어에 고급 렌더링 기능을 추가하고 있다. 상용의 CAD/CAM 모델러에서는 NURB 곡면을 기초로 모델링을 수행하므로, NURB 곡면을 렌더링할 수 있는 패키지가 필요하다. VIF(Visual InterFace) 렌더링 라이브러리는 A-buffer 방식과 Ray tracing 방식의 두 가지 고급 렌더링 모드를 제공한다. 다각형은 물론 NURB 곡면을 입력으로 받아 사용자가 설정한 표면의 각종 계수, 원하는 view와 설정된 광원에 따라 이미지를 만들고 다양한 형태로 출력시킬 수 있는 다양한 기능을 제공한다. 본 논문에서는 VIF 렌더링 라이브러리에 대한 구조와 기능별로 분류된 함수에 대하여 설명하며, 실제로 CAD/CAM 시스템과 통합되어 구상설계에서부터 3차원 설계 모델링에 이르기까지의 제조공정에서 설계검증 툴로써 어떻게 활용되고 있는가에 대하여 기술한다.Abstract Engineers and industrial designers want to produce a realistic-looking images of a 3D model without spending a lot of time and money. Photo-realistic images are so useful from the conceptual design, through its verification, to the machining, that most major CAD venders offer built-in as well as add-on photo-realistic rendering capability to their core CAD software. Since 3D model is consists of a set of NURB surfaces in commercial CAD packages, we need a renderer which handles NURB surface as well as other primitives.A new rendering library called VIF (Visual InterFace) provides two photo-realistic rendering modes: A-buffer and Ray tracing. As an input data it takes NURB surfaces as well as polygonal data and produces images in accordance with the surface parameters, view and lights set by user and outputs image with different formats. This paper describes the overall architecture of VIF and its library functions classified by their functionalities, and discusses how VIF is used as a graphical verification tool in manufacturing processes from the conceptual design to 3D modeling.

Comparative evaluation of repeatability of scanning abutment tooth stone model and impression : Applied assessment of CAD/CAM ISO standard in dentistry (치과 캐드캠 ISO평가 기준에 준한 지대치 경석고 모형 및 인상체 스캐닝의 반복측정안정성 비교 평가)

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Chong-Myeong;Kim, Dong-Yeon;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Purpose: The purpose of this in vitro study compared to evaluation of repeatability of scanning abutment tooth stone model and impression applied CAD/CAM ISO standard in dentistry. Methods: To evaluate repeatability of scanning abutment tooth stone model, were repeatedly scanned to obtain 11 data via 3D stereolithography (STL) files. 10 data (STL files) were compared with the first 3D data (STL file), and the error sizes were measured by using 3D superimposing software(n=10). Also, the repeatability of scanning abutment tooth impression was evaluated with the same procedure. Independent t test was performed to evaluate the repeatability of scanning abutment tooth stone model versus impression through root mean square(RMS) and standard deviation(SD)(${\alpha}=0.05$). Results: $RMS{\pm}SD$ with regard to repeatability were $14.7{\pm}2.5{\mu}m$, $17.1{\pm}4.0{\mu}m$, respectively, with scanning abutment tooth stone model and impression(p=0.129). Conclusion: This study results showed a little different repeatability of scanning abutment tooth stone model and impression applied CAD/CAM ISO standard in dentistry, will suggest futures good studies and clinical advantages.

A Framework for the Geometric Modeler with Open Architecture (개방형 형상모델러의 시스템 설계)

  • S.H. Han;G.H. Choi;S.H. Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.9-18
    • /
    • 1995
  • The use of CAD/CAM systems is growing fast in the shipbuilding industry. To develope a geometric modeler, the existing CAD/CAM systems have been analysed. Because existing systems have closed architectures, it is not easy to investigate the internal structures. However, new trends in the software engineering, open architectured systems, pose some possibility to develope the geometric modeler. Several geometric modelers are analysed to extract component functions and modules. ACIS of the Spatial Technology, AIS of the CAM-I consortium, the STEP part for the geometry and topology, CAD*I of the ESPRIT project, and domestic modelers are investigated. Based on this analysis, a reference model which shows the framework of the modeler is proposed. With the data structure supporting non-manifold topologies, the reference model can be used to encourage a cooperative development program.

  • PDF

Development of CAE Service Platform Based on Cloud Computing Concept (클라우드 컴퓨팅기반 CAE서비스 플랫폼 개발)

  • Cho, Sang-Hyun
    • Journal of Korea Foundry Society
    • /
    • v.31 no.4
    • /
    • pp.218-223
    • /
    • 2011
  • Computer Aided Engineering (CAE) is very helpful field for every manufacturing industry including foundry. It covers CAD, CAM, and simulation technology also, and becomes as common sense in developing new products and processes. In South Korea, more than 600 foundries exist, and their average employee number is less than 40. Moreover, average age of them becomes higher. To break out these situations of foundry, software tools can be effective, and many commercial software tools had already been introduced. But their high costs and risks of investment act as difficulties in introducing the software tools to SMEs (Small and Medium size Enterprise). So we had developed cloud computing platform to propagate the CAE technologies to foundries. It includes HPC (High Performance Computing), platforms and software. So that users can try, enjoy, and utilize CAE software at cyber space without any investment. In addition, we also developed platform APIs (Application Programming Interface) to import not only our own CAE codes but also 3rd-party's packages to our cloud-computing platforms. As a result, CAE developers can upload their products on cloud platforms and distribute them through internet.