• Title/Summary/Keyword: CAD-CAM technique

Search Result 180, Processing Time 0.03 seconds

Full mouth rehabilitation of a severely worn dentition using intraoral scanner and the CAD/CAM double scanning technique (중증도의 치아 마모 환자를 구내 스캐너와 이중스캔을 이용해 수복한 완전구강회복 증례)

  • Yoon, Se-Na;Han, Jung-Suk;Yeo, In-Sung;Yoon, Hyung-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • With the evolution of the computer-aided design/computer-aided manufacturing (CAD/CAM) technology, the intraoral scanners are playing an increasingly important role, as they are the first step towards a completely digital workflow. The CAD/CAM double scanning technique has been used to transfer the information from provisional restorations to definitive restorations. In this case, a 67-year-old male with esthetically compromised anterior teeth, generalized severe attrition of teeth, and reduced vertical dimension was treated with full mouth rehabilitation including a re-establishment of the lost vertical dimension of occlusion assisted by the crown lengthening procedure. The provisional restorations were fabricated using an intraoral scanner and the CAD/CAM double scanning technique. After the period of adaption, the definitive monolithic zirconia restorations were delivered. The CAD/CAM double scanning technique successfully transferred the occlusal and morphological characteristics, obtained from the provisional restorations, to the definitive restorations.

CAD/CAM/CAT Turmaround System for Precision Machining (정밀가공을 위한 CAD/CAM/CAT 일괄처리시스템)

  • 안중용;김승철;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.417-422
    • /
    • 1993
  • In order to minimize turnaround of machining in FMS lines, CAD/CAM/CAT integrated system called MascCAM was developed. Developing enhanced CAM and inspection modules in the MascCAM environment, 2D came, 2 $^{1}$2/ D prismatic parts and 3D free-formed surfaces were able to be automatically designed, manufactured and inspected on the machine tools by using AutoCAM and Z-map. Introducing Z-map technique, the MascCAM was able to be interfaceed with and CAD system. Developed QPPGT module generates a quick and fool-proof inspection work to users. A vertical and a horizontal machining center equipped with FANUC OMC were used for experiments. Performance of the system was confirmed by a large amount of experiments.

  • PDF

Development of a CAD/CAM System for Marine Propeller (프로펠러 가공 전용 CAD/CAM 시스템 개발)

  • Jeon, Yong-Tae;Yun, Jae-Ung;Park, Se-Hyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.53-61
    • /
    • 2000
  • The manufacture of a marine propeller typically requires long lead time to generate 5-axis tool path. Hence it may take several weeks to manufacture a satisfactory propeller with a general purpose CAD/CAM system. In this research a dedicated 5-axis CAD/CAM system for machining marine propellers has been developed, The system employs various methods to enhance the productivity : interference-free tool path generation employing check vectors and optimum cutter size determinants. In addition an iterative NURBS modeling technique is used to improve the accuracy of the modeled surface and effective cutting conditions are determined and recommended empirically to increase the productivity. The proposed CAD/CAM system has been implemented with C++ and OpenGL graphic library on the Windows system. The system validation and sample results are also given and discussed.

  • PDF

A case of digital maxillary complete denture and mandibular implant overdenture fabricated by CAD-CAM technique (완전 무치악 환자에서 CAD-CAM 기법을 이용한 상악 총의치 및 하악 임플란트 피개의치 수복: 증례 보고)

  • Kim, Kun Min;Oh, Kyung Chul;Kim, Sang Hyun;Han, Chol Gwan;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.442-450
    • /
    • 2021
  • The CAD-CAM technique is a rapidly developing field in the dental field and is applied to various fields of prosthetic treatment. Among them, the manufacturing of dentures using the milling technique classified as subtractive manufacturing is one of the commercialized digital full denture manufacturing methods. At the same time, it is possible to more efficiently manufacture a metal framework for implant overdenture by selective laser sintering or melting technique classified as an additive manufacturing method. The purpose of this article is to describe the fabrication of CAD-CAM maxillary complete denture and mandibular implant overdenture as well as its features.

Ceramic materials for chair side CAD/CAM (체어사이드 CAD/CAM에서 사용하는 세라믹 소재)

  • Kim, Heechul
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.16-26
    • /
    • 2014
  • Materials that can be use in CAD/CAM are composite, ceramic, hybrid and metal. Among the available materials, monolithic ceramic technique which is the manufacturing technique using one type of the materials is mainly used in a dental office. It is the technique where final tooth-shaped prostheses are made from the material block and used after polishing or applying heat and that does not require traditional ceramic build-up process. Although shot of esthetic quality, because manufactured within 1 hour the monolithic ceramic technique has advantages such as that treatment can be completed in one day and in one time visit, that stability of the material is high because there are low possibility of distort by not melting and phase transformation, and that it can be easily worked in the office with computer assisted devices. We classified the materials that can be used in this technique based on their generations from clinical stand point.

Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

  • Al-Fouzan, Afnan F.;Al-mejrad, Lamya A.;Albarrag, Ahmed M.
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.402-408
    • /
    • 2017
  • PURPOSE. The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION. The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

Internal evaluation of provisional restorations according to the dental CAD/CAM manufacturing method : Three-dimensional superimpositional analysis (치과 CAD/CAM 가공방식에 따른 임시보철물의 내면 적합도 : 3차원 중첩 분석)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the internal fit of two different temporary restorations fabricated by dental CAD/CAM system and to evaluate clinical effectiveness. Methods: Composite resin tooth of the maxillary first molar was prepared as occlusal reduction(2.0mm), axial reduction(1mm offset), vertical angle(6 degree) and chamfer margin for a temporary crown and duplicated epoxy die was fabricated. The epoxy dies were used to fabricate provisional restorations by CAD/CAM milling technique or 3D-printing technique. The inner data from all crowns were superimposed on the master die file in the 'best-fit alignment' method using 3D analysis software. Statistical analysis was performed using a Wilcoxon's rank sum test for differences between groups. Results: It showed that the internal RMS(Root Mean Square) values of the additive group were significantly larger than those of other group. No significant differences in internal discrepancies were observed in the temporary crowns among the 2 groups with different manufacturing method. Conclusion: All the groups had the internal fit within the clinical acceptable range (< $50{\mu}m$). The continuous research in the future to be applied clinically for the adaptation of additive manufacturing technique are needed.

Graphics-Oriented CAD Developmen of Kinematic Analysis And Simwlation of An Automatic Feeding System By A Curvilinear Cam. Part II : Graphics-Oriented CAD Development (곡선 캠을 이용한 자동 이송장치의 기구 해석 및 Simulation용 Graphic-Oriented CAD 개발 2)

  • 신중호;류갑상;김상진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.269-272
    • /
    • 1987
  • This paper is concerned on kinematic analysis and simulation of an automatic feeding mechanism subjected by the motion of a curvilinear inverse cam. The main objection is the development of computer-aided design (CAD) program for simulating the motion of the cam-feeding mechanism using computer-graphics. A computer program CACAFS (Computer-Aided Cam and Automatic Feeding System) is independent of computer hardware used. The program is also interactive using a menu-selection technique. As the second part of the paper for the motion simulation of the cam-feeding system, this paper discusses the state-of-art for CAD. The first part of the paper presents the algorithm to simulate the notion of the cam-feeding mechanism.

  • PDF

Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner (임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용)

  • Park, Ji-Manm;Park, Eun-Jin;Heo, Seong-Joo
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

Influence of surface treatments and repair materials on the shear bond strength of CAD/CAM provisional restorations

  • Jeong, Ki-Won;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.95-104
    • /
    • 2019
  • PURPOSE. To evaluate the effect of surface treatments and repair materials on the shear bond strength and to measure the fracture toughness of CAD/CAM provisional restoration materials. MATERIALS AND METHODS. Four CAD/CAM (3D printing: Nextdent C&B and ZMD-1000B Temporary, CAD/CAM resin block: Yamahachi PMMA disk and Huge PMMA block) and four conventional (monometacrylate: Jet and Alike, dimetacrylate: Luxatemp and Protemp 4) materials were selected to fabricate disk-shaped specimens and divided into six groups according to surface treatment (n=10). CAD/CAM materials were repaired with Jet or Luxatemp, while conventional materials were repaired with their own materials. The shear bond strength was measured by using universal testing machine. Ten rectangular column-shaped specimens for each material were fabricated to measure the fracture toughness by single edge v notched beam technique. Statistical analysis was performed by one-way ANOVA. RESULTS. The highest shear bond strength of CAD/CAM materials was achieved by SiC paper + sandblasting. It was also accomplished when repairing 3D printing materials with Luxatemp, and repairing CAD/CAM resin blocks with Jet. Yamahachi PMMA disk showed the highest fracture toughness. Nextdent C&B showed the lowest fracture toughness value but no statistically significant difference from Alike and Luxatemp (P>.05). CONCLUSION. In order to successfully repair the CAD/CAM provisional restoration, mechanical surface treatment and appropriate repair material according to the CAD/CAM material type should be selected. The CAD/CAM provisional materials have proper mechanical properties for clinical use as compared to conventional materials.