• 제목/요약/키워드: CAD/CAM zirconia all-ceramic restoration

검색결과 16건 처리시간 0.022초

치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구 (A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems)

  • 정창섭;박종경
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.

CAD/CAM Zirconia All Ceramic Restoration and Red-White Esthetics

  • 조종만
    • 대한심미치과학회지
    • /
    • 제13권1호
    • /
    • pp.31-39
    • /
    • 2004
  • For the prosthodontic results which are compatible with esthetics to be fulfilled, the first prerequisite would be periodontal intervention and stability, the second one may be functional competency and the ultimate goal should be ascribed to esthetic considerations. Other words, esthetic dentistry is a whole entity which encompasses the biological stability of the periodontium, physical accuracy of the prosthodontic structure and finally, the beauty which can be found in natural dentition. It also implies the harmonized lip line which reveals the well-balanced tooth morphology and health gum profiles (Red-White Esthetics). Largely, there lie some differences in the input system of the 3-dimentional data from the prepared abutments between respective computer-assisted systems available now. But the manufacturing systems (CAM) are very similar between them, to say, comprise numeric control systems with whole 3-dimensional milling units according to the restorations to be made. Now the author is going to present CAD/CAM Zirconia All Ceramic Restoration on the topics for the Red-White Esthetics, periodontal control and maintenance, treatment for the discolored teeth, post & core build-up works for the devitalized teeth, characteristics of the Zirconium oxide All Ceramics, fabrication procedures, clinical considerations and its application to diverse clinical situations.

  • PDF

Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns

  • Pak, Hyun-Soon;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.33-38
    • /
    • 2010
  • PURPOSE. Marginal fit is a very important factor considering the restoration's long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system). MATERIALS AND METHODS. 20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test. RESULTS. The means and standard deviations of the marginal fit were $61.52{\pm}2.88{\mu}m$ for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and $83.15{\pm}3.51{\mu}m$ after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of $62.22{\pm}1.78{\mu}m$ before porcelain veneering and $82.03{\pm}1.85{\mu}m$ after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well. CONCLUSION. The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

치과용 지르코니아로 제작된 심미보철물의 임상적 예후에 관한 문헌고찰 (Review of clinical studies applying yttrium tetragonal zirconia polycrystal-based esthetic dental restoration)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.307-312
    • /
    • 2020
  • Application of ceramic materials for fabrication of dental restoration materials has been a focus of interest in the field of esthetic dentistry. The ceramic materials of choice are glass ceramics, spinel, alumina, and zirconia. The development of yttrium tetragonal zirconia polycrystal (YTZP)-based systems is a recent addition to all-ceramic systems that have high strength and are used for crowns and fixed partial dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-produced, YTZP-based systems are popular with respect to their esthetic appeal for use in stress-bearing regions. The highly esthetic nature of zirconia and its superior physical properties and biocompatibility have enabled the development of restorative systems that meet the demands of today's patients. Many in vitro trials have been performed on the use of zirconia; however, relatively fewer long-term clinical studies have been published on this subject. The use of zirconia frameworks for long-span fixed partial dentures is currently being evaluated; in the future, more in vivo research and long-term clinical studies are required to provide scientific evidence for drawing solid guidelines. Further clinical and in vitro studies are required to obtain data regarding the long-term clinical use of zirconia-based restorations.

지르코니아 전부 도재관을 이용한 구강 완전 회복 증례 (A full-mouth rehabilitation using zirconia all-ceramic crowns: a case report)

  • 최인선;김동운;이정진;김경아;서재민
    • 구강회복응용과학지
    • /
    • 제31권3호
    • /
    • pp.231-241
    • /
    • 2015
  • 환자의 심미적 요구가 증가함에 따라 전치뿐만 아니라 구치부에서도 자연치아와 유사한 색조와 외형을 재현한 보철물에 대한 필요성이 증가하고 있다. 단일 지르코니아와 CAD/CAM 시스템을 통해 이러한 환자의 요구를 만족시키는 보철물 제작이 가능해졌다. 본 증례는 70세 여자환자로 전치부 보철물이 깨져서 보기 싫고 하악 구치부가 없어서 저작이 불편하다는 주소로 내원하였다. 하악 구치의 상실로 교합평면이 붕괴되었으며 과도한 치아 마모 및 수직고경 상실이 관찰되어 치아 상실 부위에 임플란트를 식립하고 수직고경 증가와 함께 지르코니아 고정성 보철물을 이용한 전악 수복 치료를 진행하였다. 치료 후 3년 간 이상적인 교합이 잘 유지되고 기능적, 심미적으로 만족한 결과를 얻었기에 이를 보고하는 바이다.

How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materials

  • Hasanzade, Mahya;Moharrami, Mohammad;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.344-350
    • /
    • 2020
  • PURPOSE. Recently introduced hybrid and reinforced glass ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials have been used for full-coverage restorations. However; the effect of adjustment and type of materials on internal and marginal adaptation are unknown. This study aimed to evaluate and compare the marginal and internal adaptations of crowns made of three different CAD/CAM materials before and after adjustment. MATERIALS AND METHODS. One acrylic resin maxillary first molar was prepared and served as the master die. Thirty-six restorations were fabricated using CAD/CAM system (CEREC Omnicam, MCXL) with three materials including lithium disilicate (IPS e.max CAD), zirconia-reinforced lithium silicate (Suprinity), and hybrid ceramic (Enamic). Internal and marginal adaptations were evaluated with the reference point matching technique before and after adjustment. The data were analyzed using mixed ANOVA considering α=.05 as the significance level. RESULTS. The effect of adjustment and its interaction with the restoration material were significant for marginal, absolute marginal, and occlusal discrepancies (P<.05). Before adjustment, Suprinity had lower marginal discrepancies than IPS e.max CAD (P=.18) and Enamic (P=.021); though no significant differences existed after adjustment. CONCLUSION. Within the limitations of this study, crowns fabricated from IPS e.max CAD and Suprinity resulted in slightly better adaptation compared with Enamic crowns before adjustment. However, marginal, axial, and occlusal discrepancies were similar among all materials after the adjustment.

Influence of heat treatment on the microstructure and the physical and mechanical properties of dental highly translucent zirconia

  • Dimitriadis, Konstantinos;Sfikas, Athanasios Konstantinou;Kamnis, Spyros;Tsolka, Pepie;Agathopoulos, Simeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.96-107
    • /
    • 2022
  • PURPOSE. Microstructural and physico-mechanical characterization of highly translucent zirconia, prepared by milling technology (CAD-CAM) and repeated firing cycles, was the main aim of this in vitro study. MATERIALS AND METHODS. Two groups of samples of two commercial highly-translucent yttria-stabilized dental zirconia, VITA YZ-HTWhite (Group A) and Zolid HT + White (Group B), with dimensions according to the ISO 6872 "Dentistry - Ceramic materials", were prepared. The specimens of each group were divided into two subgroups. The specimens of the first subgroups (Group A1 and Group B1) were merely the sintered specimens. The specimens of the second subgroups (Group A2 and Group B2) were subjected to 4 heat treatment cycles. The microstructural features (microstructure, density, grain size, crystalline phases, and crystallite size) and four mechanical properties (flexural strength, modulus of elasticity, Vickers hardness, and fracture toughness) of the subgroups (i.e. before and after heat treatment) were compared. The statistical significance between the subgroups (A1/A2, and B1/B2) was evaluated by the t-test. In all tests, P values smaller than 5% were considered statistically significant. RESULTS. A homogenous microstructure, with no residual porosity and grains sized between 500 and 450 nm for group A and B, respectively, was observed. Crystalline yttria-stabilized tetragonal zirconia was exclusively registered in the X-ray diffractograms. The mechanical properties decreased after the heat treatment procedure, but the differences were not statistically significant. CONCLUSION. The produced zirconia ceramic materials can be safely (i.e., according to the ISO 6872) used in extensive fixed prosthetic restorations, such as substructure ceramics for three-unit prostheses involving the molar restoration and substructure ceramics for prostheses involving four or more units. Consequently, milling technology is an effective manufacturing technology for producing zirconia substructures for dental fixed all-ceramic prosthetic restorations.

CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도 (Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems)

  • 강후원;김희진;김장주;고명원
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).

Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례 (Full-mouth rehabilitation with pressed ceramic technique using provisional restorations)

  • 노현식;우이형;배아란
    • 대한치과보철학회지
    • /
    • 제51권1호
    • /
    • pp.47-51
    • /
    • 2013
  • 골유착성 임플란트의 등장으로 결손치의 수복이 가능하게 되어 전통적인 고정성 또는 가철성 국소의치가 임플란트로 대체되어가고 있는 추세이다. 특히 젊은 환자의 경우 보철물의 수명과 함께 심미적인 결과를 고려해야 한다. 임플란트는 장기간의 성공적인 치료 결과와 함께 기능적인 회복을 이룰 수 있으나, 치은 퇴축으로 인한 변연부 노출, 치간 유두 상실로 인한 비심미적인 연조직, 금속 지대주, 상부 도재관의 투명도 감소 등은 임플란트 수복 시 정상적인 저작 기능 회복은 이룰 수 있으나 심미적으로는 불리한 결과를 보일 수 있다. 최근 CAD/CAM technology를 이용한 지르코니아는 충분한 강도와 파절 저항성을 가져 정상적인 저작 기능이 가능하고, 뛰어난 굴곡강도로 고정성 보철물, 가철성 의치 보철물에 다양하게 응용되며, 생체 적합성이 뛰어나고, 색조 재현성에서도 금속에 비해 심미적인 결과를 보이며 전치부와 구치부의 보철 치료에 이용되고 있다. 그리고 pressed ceramic technique을 이용한 전부 도재 보철 수복은 기존의 전통적인 도재 축성 과정보다 우수한 파절 저항성을 보인다. Pressed ceramic technique 은 상부의 도재 축성 과정이 왁스업을 통해 용융, 주조 되어 최종 보철물의 형태를 왁스업 단계에서 조절할 수 있는 장점이 있다. 임플란트를 포함한 본 증례의 보철 수복은 임시 보철물의 치경부 형태를 조절하여 심미적인 연조직을 재현하고자 하였고, 임시 보철물의 형태를 왁스업으로 복제하여 원하는 형태의 최종 보철물을 제작하였다. 본 증례에서는 임플란트 치료에 있어서 지르코니아와 pressed ceramic technique을 적용하여 기능적이고 심미적으로 양호한 결과를 얻었다.