• Title/Summary/Keyword: CAD/CAM dental

Search Result 423, Processing Time 0.024 seconds

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

Effects of the Addition of Alumina on the Mechanical Properties of Cast Zirconia Sintered Body (주입성형한 지르코니아 소결체의 기계적 성질에 미치는 알루미나 첨가의 영향)

  • Lee, Dong-Yoon;Jo, Jun-Ho;Seo, Jeong-Il;Bae, Won-Tae
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.113-119
    • /
    • 2012
  • Purpose: Zirconia blocks for all ceramic dentures are divided into two groups. One is pre-heated block and the other is binder added block. In this study, the possibility of recycling the remained parts of binder added block after CAD/CAM machining with slip casting process was investigated. Methods: Owing to the binder added block contain large amount of organic matter, Binder burn-out was must be carried out before ball milling for preparing the casting slip. Binder burn-out was accomplished at $600^{\circ}C$ for 10 hours. Ball milling was performed with 5mm zirconia ball and 60mm polyethylene bottle. From 0% to 5% at 1% intervals of alumina was added to zirconia powder for preparing slip. Solid casting was achieved with plaster mold. Cast bodies were dried and sintered at $1,500^{\circ}C$ for 1 hour. Linear shrinkage, apparent porosity, water absorption, bulk density, and flexural strength were tested. Microstructures were observed by SEM, EDS and XRD analysis were executed. Results: Optimum slips for casting was prepared with 300g ball, 100g powder, and 180g distilled water. Cast body without alumina showed 26% of linear shrinkage, 6.07 of apparent density, and 470MPa of three point bend strength. On the other hand, as received zirconia block, which was sintered at the same conditions, showed 23% of linear shrinkage, 6.10 of apparent density, and 680MPa of three point bend strength. When 3% of alumina was added to zirconia, sintered body showed 23% of linear shrinkage, 6.10 of apparent density, and 780MPa of three point bend strength. SEM photomicrographs and EDS analysis showed alumina particles uniformly dispersed in zirconia matrix, and XRD analysis showed no phase transformation of tetragonal zirconia particles was occurred when alumina was added. Conclusion: According to the all of this experimental results, 3% of alumina added cast zirconia body showed excellent mechanical properties more than as received binder containing zirconia block.

Marginal Adaptation of Zirconium Dioxide Core according to the Abutment Teeth (지대치 형태에 따른 지르코니아 코어의 변연 적합도)

  • Kim, Ki-Baek;Kim, Seok-Hwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.15 no.1
    • /
    • pp.54-59
    • /
    • 2015
  • The present study investigated the influences of various abutment teeth shapes (maxillary right canine, pre-molar, molar) on the marginal adaptation of computer aided design/computer aided manufacturing-fabricated zirconia core. In vitro adaptation of zirconia cores manufactured by three different abutments were evaluated. Thirty zirconia cores were made per each models and the adaptation was evaluated through a silicone replica technique. The measurement of the adaptation was carried out using digital microscope. The mean and standard deviation of each reference point were analyzed using the one-way (ANOVA) and Tukey's honestly significant difference tests (${\alpha}=0.05$). The overall marginal fits of the zirconia cores were as follows: canine: $47.59{\mu}m$, pre-molar: $43.74{\mu}m$, molar: $40.36{\mu}m$. They were no statistically significant differences between groups for adaptation (p>0.05). This confirmed that the type of abutment teeth used does not determine the precision of fit of zirconia core.

A comparative study of the improvement after different self-assessment methods of tooth preparation (치아 삭제의 다른 자가 평가 방법 후 개선에 대한 비교 연구)

  • Kim, JungHan;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.220-227
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the degree of tooth preparation abilities of students according to three self-assessment methods. Materials and Methods: forty-eight sophomores in Kyungpook National University College of Dentistry were divided into three experimental groups. Students performed tooth preparation of the left mandibular first molar for full gold crown. They performed self-assessment using the three methods (visual, digital, and putty index self-assessment group), and reperformed tooth preparation. An intraoral scanner was used to scan each tooth model (prepared tooth and unprepared tooth), and data were acquired in standard tessellation language (STL) file format. The STL files of prepared tooth and unprepared tooth were superimposed using the 3-dimensional analysis software (Geomagic control X). And the reduction amount was measured. In the statistical analysis, all values of reduction amount were analyzed with the Wilcoxon signed rank test and Kruskal-Wallis test (α = 0.05). Results: The three self-assessment methods showed statistically significant differences (P < 0.001). The putty index self-assessment group showed the highest reduction in error than the digital self-assessment method. Conclusion: Within limitations of this study, students showed significant differences in improvement of tooth preparation ability according to the three self-evaluation methods.

Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach (디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례)

  • Jeong, Areum;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.283-292
    • /
    • 2022
  • For fixed prosthetic treatment using implants, implants must be placed in a suitable location for prosthetic treatment. During surgery, minimally invasive prosthetic restoration is possible using a flapless method using a surgical guide. The patient in this case was an 86-year-old male patient who wanted treatment due to discomfort when using conventional dentures. Due to systemic disease, the patient had difficulty using removable local dentures, so full dentures for the maxilla and fixed implants for the mandible were restored. Because there is a high risk of bleeding due to systemic disease, the implant was placed in a flapless method using a surgical guide. Finally, prostheses were fabricated with maxillary full denture and mandibular screw-retained zirconia, and this report shows satisfactory esthetic and functional recovery.

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

Effect of fabrication method and surface polishing on the surface roughness and microbial adhesion of provisional restoration (임시 수복물의 제작 방식과 표면 연마가 표면 거칠기와 세균 부착에 미치는 영향)

  • Yeon-Ho Jung;Hyun-Jun Kong;Yu-Lee Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.149-158
    • /
    • 2024
  • Purpose: This study aims to investigate the effects of provisional restoration fabrication methods and surface polishing on surface roughness and microbial adhesion through in vitro experiments. Materials and Methods: 120 cylindrical provisional restoration resin blocks (10 × 10 × 2.5 mm) were manufactured according to four fabrication methods, and 30 specimens were assigned to each group. Afterwards, they were divided into non-polishing group, #400 grit SiC polishing group, and #800 grit SiC polishing group and polished to a 10 × 10 × 2 mm specimen size (n = 10). The surface roughness Ra and Ry of the specimen was measured using a Surface Roughness Tester. Three specimens were extracted from each group and were coated with artificial saliva, and then Streptococcus mutans were cultured on the specimens at 37℃ for 4 hours. The cultured specimens were fixed to fixatives and photographed using a scanning electron microscope. For statistical analysis, the two way of ANOVA was performed for surface roughness Ra and Ry, respectively, and the surface roughness was tested post-mortem with a Scheffe test. Results: The fabrication method and the degree of surface polishing of the provisional restorations had a significant effect on both surface roughness Ra and Ry, and had an interaction effect. There was no significant difference in Ra and Ry values in all polishing groups in DLP and LCD groups. Conclusion: The fabrication method and surface polishing of the provisional restoration had a significant effect on surface roughness and showed different adhesion patterns for S. mutans adhesion.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

Effect of coloring agent dryness on zirconia color (치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Hae-Jung;Moon, Yun Hee;Kim, Woong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.176-182
    • /
    • 2018
  • One of the most important factor of esthetic prosthesis is the color of the teeth. Zirconia is produced in the process of design, milling, coloring, drying, and sintering. The effect of the drying degree of zirconia colorant on the color tone is examined. For the experiment, a total of 45 zirconia specimens(15 for each) were fabricated by using cad/cam system. The zirconia specimens(L block(LAZOR), Z block(Zircos-E block posterior), A block(AlphaZ)) were then subjected to zirconia sintering in accordance with the manufacturer's instructions, using a chemical coloring agent to Non-drying(0sec), intermediate (10sec), and completely dried (10min) temperature holding times. The color tone was measured using a spectrophotometer. The results were analyzed with a One-way analysis of variance and the Tukey post-hoc test (${\alpha}=.05$) The $L^*$ values of L, A specimens, $a^*$ values of A specimens, and $b^*$ values of Z specimens were not statistically different according to the degree of drying (p>0.05), While the $L^*$ value of Z specimen, $a^*$ value of L, Z specimen, $b^*$ values of L, A specimens were statistically different according to the degree of drying(p <0.05). In conclusion, the drying of zirconia colourants improves zirconia brightness and increases the optical properties of the enamel.

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.