• 제목/요약/키워드: CAD/CAM coping

검색결과 47건 처리시간 0.029초

치과용 Co-Cr sinter metal의 소결 후 변형비교 (Observation of Shape after sinter of Dental Co-Cr sinter metal)

  • 송준부;김갑진
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.127-133
    • /
    • 2016
  • Purpose: Currently advanced in Dental CAD/CAM technology increase a use of Co-Cr sinter metal block at Dental CAD/CAM part traditionally it has been being used with metal casting method. There is an advantage that can leave out a step of investment and casting as well as reducing a working time to compare with conventional casting method in a dry milling. Methods: In this research, compare a deformation of before and after sinter result of Co-Cr sinter metal block. Design a specimen figure by 3D CAD software and transformed it to a STL file can be used at Dental CAD/CAM. With a transformed STL file, milled a Co-Cr sinter metal specimen by using a Dental CAD/CAM dry milling machine. It arrived at the following conclusions after measuring an outer form and thickness of a machined specimen and then after sinter measure it again in a way of before sinter measurement method. Results: It is confirmed that there is no error while a 3D design figure specimen is transformed to a Dental CAD data. It is observed that there is no error at Co-Cr sinter metal specimen which consider a length of single coping and bridge. Conclusion: It is observed that there is no deformation at a specimen of AS05 and AB05 are made of 0,5mm thickness. On the other hand, the out of range of deformation is observed at a specimen of AS10 and AB10 which are made of 1mm thickness.

2대의 CCD 카메라를 이용한 3차원 위치측정과 코핑 (3D Position Measurement & Coping using 2 CCD Cameras)

  • 강원찬;신석두;김영동
    • 전기학회논문지P
    • /
    • 제51권2호
    • /
    • pp.87-93
    • /
    • 2002
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, especially for system design, manufacturing and inspection. Two-camera method keeps accuracy more than double than mechanical method. In this paper, a new method is studied to acquire 3D geometric data of the small object such as a die in stone model. When the devices, cameras, laser beam and object are in a perfect plane, the calculation is measured by position error 0.025[mm] within. But this paper shows that arbitrarily positioned system can also be used to obtain 3D data. Also, this paper present a method to generate coping surface data with which CAM system can do for milling work.

디지털 치의학의 과거와 현재 그리고 미래 (Digital Dentistry; Yesterday, Today, and the Future)

  • 김창환
    • 대한심미치과학회지
    • /
    • 제24권1호
    • /
    • pp.25-38
    • /
    • 2015
  • 치과계에서 캐드캠이 보급되면서 본격적으로 사용한 지 15년이 넘었다. 코핑 정도의 역할에서 구치부 전부관으로 확대되었고, 최근에는 전치부에서도 많이 사용하는 추세이다. 장비의 발전도 비약적이었지만 지르코니아 블록의 발전이 가장 많이 이루어졌다. 개개인의 능력이나 경험 차에 의해 차이는 있을 수 있겠지만, 도재를 올리지 않고 지르코니아에 컬러링만으로도 얼마든지 색을 표현 할 수 있다. 또한 캐드 디자인 만으로도 표면의 질감을 표현하는 것에 우리가 알고 있는 만큼 가능하다. 본 논문에서는 이러한 디지털 치과학의 변천과정을 정리해 보고자 한다.

Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.439-448
    • /
    • 2016
  • PURPOSE. The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND METHODS. Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a $5^{\circ}$ convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed. RESULTS. The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and $117{\mu}m$ and those from Zirkonzahn system were between 111 and $115{\mu}m$. Marginal discrepancies of copings made with Ceramil system were between 101 and $131{\mu}m$ and those from Zirkonzahn system were between 116 and $131{\mu}m$. CONCLUSION. Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.

CAD/CAM으로 제작된 지르코니아 코어의 지대치 형태에 따른 변연 및 내면 적합도에 관한 연구 (Marginal and internal fit according to the shape of the abutment of a zirconia core manufactured by computer-aided design/computer-aided manufacturing)

  • 김지수;류재경
    • 대한치위생과학회지
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2022
  • Background: In this study, zirconia copings were fabricated by setting clinically acceptable inner values for prostheses using computer-aided design/computer-aided manufacturing (CAD/CAM). The processed copings were evaluated for the marginal and internal fit of each abutment shape with a CAD program using the silicone replica technique. Methods A total of 20 copings was produced by selecting models commonly used in clinical practice. After injecting the sample, the minimum thickness, internal adhesion interval, and distance to the margin line were set to 0.5, 0.05, and 1.00 mm using a dental CAD program, respectively. It was measured using a 2D section function in a three-way program of the silicon replication technology. Although the positions and number of measurements of the anterior and posterior regions differed, nine parts of each pre-tube were designated and measured by referring to a previous study to compare the two samples. Results As a result, the average margin of the mesial, distal, and buccal (labial) surfaces was 59.90 ㎛ in the anterior region and 60.40 ㎛ in the posterior region. The mean axial wall margin was 67.25 ㎛ in the anterior region and 69.25 ㎛ in the posterior region. In occlusion, the anterior teeth (77.70 ㎛), posterior teeth (77.60 ㎛), and both anterior and posterior regions were within the clinically acceptable range. Conclusion The edge and inner fit of zirconia coping manufactured using the CAD/CAM system showed clinically applicable results. To reduce errors and increase accuracy, materials and machine errors that affect the manufacture of prosthetics should be investigated. Based on our results, the completeness of prosthetics could increase if the inner value and characteristics of the material are adjusted when applied in clinical practice.

서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성 (Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods)

  • 조영범;정재헌;김희중
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.366-376
    • /
    • 2013
  • 구강내 스캔(Group 1), 모델 광학 스캔(Group 2)과 모델 접촉식 스캔(Group 3)방식으로 각각 zirconia 코핑을 제작하여 광학 현미경으로 적합성을 관찰하였다. 측정항목은 변연오차(absolute marginal discrepancy;AMD), 변연간극(marginal gap; MG), 측방간격(gap of axial wall; GA), 선각간격(gap of line angle; GL)와 교합간격(gap of occusal surface; GO)이었으며, 결과는 아래와 같았다. 1. Group 1, Group 2, Group 3의 평균 AMD는 각 각 $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$이고, Group1, Group 2, Group 3의 MG는 각 각 $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$였다. AMD와 MG는 각 그룹에서 통계학적으로 유의한 차이를 보여주지 않았다(Anova test, P>0.05). 2. Group 2의 GA가 Group 1과 Group 3에 비해 통계학적으로 유의하게 적은 수치를 나타내었다(Anova test, P<0.05). 3. Group 1의 GL과 GO가 다른 그룹에 비해 통계학적으로 높은 수치를 나타내었다(Mann-whitney test(P<0.05). 세 가지 스캔 방식으로 제작된 zirconia 코핑은 세라믹 보철의 가장 중요한 평가 요소인 AMD와 MG에서 서로 통계학적 차이를 보이지 않았다.

두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교 (Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations)

  • 신호식;김석규
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.528-534
    • /
    • 2008
  • 연구목적: 변연적합도는 보철수복물의 성공을 좌우하는 중요한 요소 중의 하나이다. McLean과 von Fraunhofer등에 의하면 120 ${\mu}m$ 이하를 임상적으로 허용할 수 있다고 했는데, 이를 넘는 정확하지 않은 변연은 지각과민을 일으키거나 이차 우식을 일으키고, 치태 축적을 용이하게 하여 보철물의 수명을 단축시키게 된다. 이에 최근에 우리나라에 소개되어 임상적으로 사용되고 있는 CAD-CAM 전부도재 수복물 중 $LAVA^{(R)}$ 시스템 (3M ESPE, St. Paul, MN)과 $EVEREST^{(R)}$ 시스템 (KaVo Dental GmbH, Biberach, Germany)으로 제작한 지르코니아 전부 도재관들이 도재전장 금속주조 수복물과 비교해 보아 코핑 상태일 때와 도재축성 후 각각 변연적합도의 차이가 있는지를 살펴보고자 하였다. 재료와 방법: 상악 제1소구치 덴티폼 치아를 high speed diamond bur 로 교합면 2.0 mm, 순설면 1.0 mm, 그리고 변연은 chamfer margin을 6도 측면 경사 절삭 기계로 균일하게 제작해서 이를 인상 채득하여 금속 지대치를 제작하였다. 이를 덴티폼 모형상에 장착한 후 전악인상을 채득하여 $LAVA^{(R)}$ 수복물 코핑, $EVEREST^{(R)}$ 수복물 코핑, 그리고 도재전장 금속주조 수복물 코핑을 각각 8개씩 제작하였다. 이들 코핑을 염색제를 섞은 Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan)를 이용하여 금속 지대치에 접합시킨 뒤, $Microhiscope^{(R)}$ system (HIROX KH-1000 ING Plus, Seoul, Korea)을 이용하여 300배율로 관찰하면서 변연 간격을 ${\mu}m$단위로 측정하였다. 도재축성 후에도 마찬가지 방법으로 모든 수복물의 변연간격을 측정하여 통계 처리를 하였다. 결과: 코핑 상태에서의 평균 변연간격 값은 $EVEREST^{(R)}$ 에서 $52.00{\pm}11.94\;{\mu}m$, $LAVA^{(R)}$$ 56.97{\pm}10.00\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $97.38{\pm}18.54\;{\mu}m$를 보였고, 도재축성 후에 평균 변연 간격값은 $EVEREST^{(R)}$$61.69{\pm}19.33\;{\mu}m$, $LAVA^{(R)}$$70.81{\pm}12.99\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $115.25{\pm}23.86\;{\mu}m$를 보였다. 결론: 1. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물은 도재 전장 금속 주조 수복물과 비교하여 각각 코핑상태일 때와 도재 축성 후 모두 유의성 있는 (P < .05) 차이를 보이는 우수한 변연 적합도를 나타내었다. 2. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물 간의 평균 변연 간격 비교에서 코핑 상태일 때와 도재 축성 후에 모두 유의성 있는 차이는 없었다 (P > .05). 3. $LAVA^{(R)}$$EVEREST^{(R)}$ 그리고 PFM 은 각각 코어 상태일 때와 비교하여 도재 축성 후 변연 간격에서 약간 증가되었으나 유의성 있는 차이를 보이지는 않았다 (P > .05).

감정 및 정서상태 전이를 위한 감성 컨텐츠 추천 시스템 개발 (Development of Emotion Contents Recommender System for Improvement of Sentimental Status)

  • 박면웅;하성도;정도언;류인균;안승민
    • 감성과학
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 2007
  • 노인의 일상생활을 편안하고 즐겁게 지낼 수 있도록 도와주는 동반자 로봇의 기능 중 부정적인 감정/정서상태 개선을 위한 Infotainment Service를 소개한다. 노인의 일상생활 중에서 부정적인 감정/정서상태를 정의하고, 이들의 정서상태를 개선할 수 있는 방법들을 모색한다. 인지행동치료에서의 배경지식을 기반으로 노인의 부정적인 정서상태를 개선할 수 있는 애니메이션 클립들을 제작, 편집하여 검증해 보기로 한다. 또한, 검증된 애니메이션 클립들을 이용하여 바람직한 감정상태로의 전이를 위한 감성 컨텐츠를 제공하는 기능을 도출한다. 구체적으로 일련의 실험적 접근방법을 토대로 제작, 편집한 애니메이션 클립을 이용하여 영화의 감정요소를 분석할 수 있는 도구를 설계하고, 기존의 선호도를 고려한 영화추천 시스템을 확장한 감정요소를 고려한 영화 추천시스템을 제안한다.

  • PDF

시멘트 공간이 캐드캠 시스템으로 제작한 지르코니아 수복물의 변연과 내부 적합도에 미치는 효과 (Effect of cement space on the marginal and internal fit of zirconia restorations fabricated by CAD/CAM system)

  • 이정환;안재석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.235-242
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of zirconia copings fabricated by CAD/CAM system and to research the effect of cement space on the fit of zirconia prosthesis. Methods: Zirconia copings were designed using 3shape software and then milled from presintered zirconia blocks by Kavo dental milling machine. The cement space was set at $0{\mu}m$ around the margins for all groups, and additional cement space appling 1 mm above the finish lines of tooth. The samples were classified into 4 groups according to the cement space setting(Cs-0, Cs-40, Cs-80, Cs-120). Replica technique used to investigate marginal and internal gap. The silicone film thickness was recorded using a optical microscope with image software analysis system at 75${\times}$magnification. The assessment performed on the six points in bucco-lingual and mesio-distal sections(4 groups, 10 copings per group, 12 measuring points per coping). The data were statistically analyzed with one-way ANOVA followed by pair-wise Tukey's post hoc tests(${\alpha}$<0.05). Results: Better marginal and internal fit values were exhibited by $80{\mu}m$ cement space. The results showed that different cement space values had statistically significant effect on the marginal and internal gap of zirconia copings(p<0.001). The gap of margin and axial wall area was smaller than that the gap of occlusal area in all groups(p<0.001). Conclusion : Effect of different cement spaces on the marginal and internal gap of zirconia copings.

$Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구 (The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients)

  • 송영균;조인호;이종혁
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.470-478
    • /
    • 2008
  • 완전도재 수복물은 뛰어난 심미성을 가지고 있어, 환자들의 심미적 욕구를 충족시킬 수 있다. 이러한 도재관을 제작함에 있어 CAD/CAM 시스템을 이용하는 것은 시간과 비용을 절약할 수 있는 장점을 가지고 있으며, 정밀도 또한 점차 높아지고 있다. 특히 변연적합도는 수복물의 성공 여부에 중요한 요소이고, 이 분야에 대한 실험적 연구는 많이 보고되고 있으나 임상적인 연구는 아직 미흡한 실정이다. 본 연구에서는 CAD/CAM 시스템의 하나인 $Procera^{(R)}$ AllCeram 시스템의 변연적합도를 실제 환자의 수복물 상에서 측정함으로써 임상에 사용되는 CAD/CAM 시스템의 변연적합도를 연구하고자 하였다. 단국대학교 치과병원 보철과에 내원한 56명, 101개의 지대치에 대해 코핑 상태와 최종수복물의 변연오차를 입체광학현미경으로 측정하고 비교분석하여 다음과 같은 결과를 얻었다. 실험 결과, 코핑의 변연오차 ($53.84{\pm}38.83\;{\mu}m$)보다 최종 수복물에서의 변연오차 ($45.82{\pm}30.84\;{\mu}m$)가 더 낮은 값을 나타났으며, 이는 통계적으로 유의한 차이가 있었다 (P < .05). 각 측정 지점간 비교에서 역시 모든 변연에서 코핑 의 변연오차가 최종 수복물에서의 변연오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 구치부의 변연오차는 전치부의 변연오차보다 더 높은 값을 나타냈으나, 통계적으로 유의한 차이는 없었다. 설측 변연의 경우, 근심, 원심, 순측 변연의 오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 이상의 결과로 보아 $Procera^{(R)}$ 시스템의 Allceram 관의 변연적합도는 임상적 허용 범위 내에 있었으며, 특히 도재 축성후 변연적합도 는 더 우수해지는 것으로 나타났으며, 각 변연 중 설측 변연의 오차가 가장 큰 것은 주모형의 정보 입력시 순측 부위의 특성상 일어나는 오류로 사료된다. $Procera^{(R)}$ 시스템 Allceram 관 수복시 설측 변연에 더욱 주의를 기울이는 것이 좋은 변연적합을 얻는 데 도움이 될 것으로 사료되며, 앞으로 주모형 변연 부위의 변곡 정도에 따른 변연오차에 대한 연구가 필요할 것으로 사료된다.