• Title/Summary/Keyword: CABG

Search Result 229, Processing Time 0.024 seconds

The First 20 Cases of Cardiac Surgery Using the da $Vinci^{TM}$ Surgical System: A Single Center Experience (다빈치 수술로봇을 이용한 심장수술 20예 보고 - 단일 기관 보고 -)

  • Je, Hyoung-Gon;Lee, Yong-Jik;Jung, Sung-Ho;Jung, Jae-Seung;Kang, Pil-Je;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Background: The interest in robotic cardiac surgery has recently grown but there has not been much clinical research reported on this. The aim of this study is to examine our initial experience, since August 2007, with robotic cardiac surgery using the da $Vince^{TM}$ surgical system and to evaluate the feasibility and safety of it. Material and Method: Between August and December 2007, a total of 20 patients underwent robotic cardiac surgery using the da Vinci surgical system. For mitral valve repair (n=11), tricuspid valve repair (n=1), and ASD repair (n=1), cannulation, antegrade cardioplegia and transthoracic aortic cross-clamping were conducted for the right femoral vessels and the right internal jugular vein. For minimally invasive direct CABG (MIDCAB) (n=7), the internal thoracic artery (ITA) was harvested with the da Vinci surgical system. Result: The mean age of the patients was 50.1 (range: $26{\sim}78$) years. Three concomitant Maze procedures and one tricuspid annuloplasty were combined with mitral valve repair. The mean cardiopulmonary bypass time was $208.0{\pm}61.3$ minutes and the aortic cross clamp time was $158.8{\pm}40.6$ minutes. No patients showed more than mild mitral regurgitation after repair and the median hospital stay was 4 days. The robotic-harvested ITA was used for either left ITA (n=6) or bilateral ITA (n=1). The mean harvest time was $43.2{\pm}12.0$ minutes. The harvested ITA showed good flow and it was anastomosed under direct vision after left anterolateral thoracotomy. The patency of all the grafts was 100% (18/18) in MIDCAB. Conclusion: Robotic cardiac surgery using the da Vinci surgical system was variously adapted to areas such as mitral and tricuspid valve repair, ASD repair and ITA harvest for MIDCAB. The early results of the robotic cardiac surgery showed its safety and feasibility. With this primary report, we anticipate that clinical applications and further studies on robotic cardiac surgery using the da Vinci surgical system will be actively conducted in Korea.

Relationship of Hemodynamic Changes during Off-Pump Coronary Bypass Grafting and Their Effects on Postoperative Outcome (심폐바이패스 없이 시행하는 관상동맥 우회수술 중의 혈역학적 변수들의 변화양상 및 수술 후 결과에 미치는 영향)

  • 허재학;장지민;김욱성;장우익;이윤석;정철현
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.576-582
    • /
    • 2003
  • During the Off-Pump Coronary Arterial Bypass surgery (OPCAB), the manipulation of the heart can depress cardiac contractility and cause hemodynamic instability. In this study, hemodynamic parameters were measured during operation and the laboratory and clinical data were investigated to evaluate their effects on postoperative outcome. Material and Method: From March 2001 to August 2002, 50 consecutive patients who underwent OPCAB were included in this study. During the same period, total number of CABG was 71 The blood pressure, pulmonary artery pressure, mixed venous oxygen saturation, and cardiac index were measured before manipulation, after application of stabilizer, and at the end of anastomosis. Postoperatively, we measured the cardiac enzymes such as CK-MB, troponin 1 and checked the amount of inotropes required, chest tube drainage, the amount of transfusion, duration of ventilator support, and duration of ICU stay. Result: The number of mean distal anastomoses was 2.8$\pm$0.9 per patient. On elevation and stabilization of the heart, systolic blood pressure was depressed and pulmonary artery pressure was elevated significantly, but during each anastomosis no significant changes were detected. The peak level of cardiac markers was 29.2$\pm$46.7 for CK-MB, 0.69$\pm$0.86 for troponin 1 on postoperative day f. Among the intraoperative hemodynamic parameters, the ischemic change of EKG and bolus injection of inotropes significantly affected the posteroperative cardiac enzymes. But, no difference other than the level of cardiac enzymes between the two groups with or without the ischemic change of EKG and bolus injection of inotropes was noticed. Conclusion: The significant hemodynamic changes occurred when the heart was elevated and stabilized, however during anastomoses there were no significant changes. Serum cardiac enzymes rose significantly in the group that showed the ischemic charge of EKG or needed the bolus injection of inotropes for maintaining hemodynamic stability intraoperatively, but it did not affect the postoperative outcome. In conclusion, the ischemic change of EKG and the need for bolus injection of intropes during operation may be very indicative for probable ischemia.

Prognostic Implication of Normal Myocardial Perfusion Scintigraphy in Patients with Chest Pain (정상 심근관류신티그라피 소견을 보인 흉통환자의 예후)

  • Song, Ho-Cheon;Min, Jung-Jun;Kim, Ji-Yeul;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.67-72
    • /
    • 1997
  • Myocardial scintigraphy is a widely used noninvasive procedure with high sensitivity for the detection of patients with suspected coronary artery disease. The purpose of this study was to determine the prognostic value of a normal myocardial scintigraphy in 292 patients (150 males, 142 females, mean age $53{\pm}12$ years) with chest pain who were followed from 7 to 58 (mean 25) months. Myocardial SPECT was performed with Tc-99m MIBI in 173 patients, with Tc-99m tetrofosmin in 74 patients and with T1-201 in 45 patients. During the follow-up period, there were 2 cardiac deaths and 2 nonfatal myocardial infarctions resulting in cardiac event rate of 1.37% (0.66% Per Year). The cardiac event rate was not different in patients with angiographically normal coronary arteries (1/30, 3.3%) and in those who had significant coronary artery disease (2/27, 7.4%) (p=0.60). In conclusion, patients with chest pain and normal myocardial scintigraphy have a low cardiac event rate, and there was no significant difference of. cardiac event rates between patients with normal and abnormal coronary angiograms.

  • PDF

Coronary Angiography after Coronary artery Bypass Grafting (관상동맥 우회술후 관상동맥 조영검사 소견)

  • Choi, Jin-Ho;Park, Kay-Hyun;Jun, Tae-Gook;Lee, Young-Tak;Park, Pyo-Won;Chae, Hurn;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.182-187
    • /
    • 2002
  • Background: There have been many reports of coronary angiographic findings after coronary bypass grafting, most of which are focused on the graft patency rate of the bypass conduits. However, postoperative angiography can provide numerous informations other than patency rates that are useful for establishing operative strategy. Material and Method: We studied 73 patients in whom coronary angiography was done after more than 1 month of CABG. Mean interval from the operation to coronary angiography was 10.6 months and the reasons for coronary angiography follow up were residual or recurrent angina in 54 patients, abnormalities on myocardial perfusion scan or echocardiography in 13 patients, and for simple follow up in 6 patients. Result: Overall graft patency rate was 80.9% (internal thoracic artery 100%, saphenous vein 75.0%) in patients of simple follow up and 61.6%(internal thoracic artery 81.1%, saphenous vein 55.3%) in patients with ischemia. Progression of native coronary arterial disease proximal to the grafting site was found in 50 patients(68.5%). Among 201 coronary arterial branches that had not been completely occluded preoperatively, ninty five branches(47.3%) revealed progression of diameter stenosis by more than 20% on the follow up study. Among them, 64 branches(31.8%) progressed to total occlusion. The incidence of disease progression was highter in the coronary arteries with patent grafts(57.5%) than in those with occluded grafts(36.3%)(p<0.05), Comparing internal thoracic artery graft with saphenous vein graft, internal thoracic artery was superior to saphenous vein, not only in terms of patency(83.3% vs 56.6%), but also in terms of result of later percutaneous intervention success rate(100% vs 62%, p<0.05). Conclusion: Due to the considerable incidence of progression of native coronary artery stenosis in the early postoperative periods, bypass grafting of a vessel with borderline stenosis, especially with vein graft, must be done prudently. And it was confirmed again that revascularization of left anterior descending artery is most important and that internal thoracic artery was superior to saphenous vein.

Clinical Characteristics and Prognosis of Lymphocyte Dominant Exudative Pleural Effusion with Low ADA, Low CEA, Negative Cytology and Negative AFB Smear (항산균 도말 검사, 세포진 검사가 음성이고, ADA와 CEA가 낮은 림프구성 흉막 삼출증의 임상 양상과 예후)

  • Kang, Young Ae;Yoon, Young Soon;Lee, Sei Won;Choi, Chang Min;Kim, Deog Kyeom;Lee, Hee Seok;Ko, Dong Seok;Yoo, Chul Gyu;Kim, Young Whan;Han, Sung Koo;Shim, Young Soo;Yim, Jae Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.1
    • /
    • pp.5-10
    • /
    • 2005
  • Background : A pleural effusion is a common medical problem. Despite several diagnostic tests, 15-20% of pleural effusions go undiagnosed. The aim of this study was to evaluate the clinical characteristics and prognosis of a lymphocyte dominant exudative pleural effusion with a low adenosine deaminase (ADA), low carcinoembryonic antigen (CEA), negative cytology and negative acid fast bacilli (AFB) smear. Method : From Jan 2000 to Aug 2001, 43 patients with lymphocyte dominant exudative pleural effusions whose AFB smear and cytologic exam were negative, their pleural fluid ADA level was < 40 IU/L, and their CEA level was < 10 ng/mL were enrolled in this study. A retrospective analysis of the patients' medical records was carried out. Result : Among 31 of the 43 cases (72%), probable underlying diseases causing the pleural effusion were identified: 21cases of malignant diseases, 4 cases of liver cirrhosis, 2 cases of pulmonary tuberculosis, 1 case of end stage renal disease, 1 case of a chylothorax, 1 case of a post-CABG (coronary artery bypass graft) state, 1 case of a pulmonary embolism. No clinically suspected etiology was identified in the remaining 12 cases (28%). Of these 12 pleural effusions, 7 cases spontaneously resolved, 2 effusions resolved with antibiotics, and the other 2 cases were persistent. Conclusion : Lymphocyte dominant exudative pleural effusions with a low ADA, low CEA, negative cytological exam, and negative AFB smear, but without a definite cause might have a benign course and clinicians can observe them with attention.

Use of Intermittent Antegrade Warm Blood Cardioplegia in CABG (관상동맥 우회로조성술에서 간헐적 전방 온혈 심정지액의 이용)

  • 김정택;백완기;김영삼;윤용한;김혜숙;이춘수;임현경;김현태;김광호
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.828-833
    • /
    • 2003
  • Background: It has been reported that the recently developed intermittent antegrade warm blood cardioplegia (IAWBC) has better myocardial protective effects during coronary artery bypass surgery than cold blood cardioplegia or continuos retrograde cold blood cardioplegia. The aim of this study is to evaluate the safety and usefulness of IAWBC by comparing it retrospectively with intermittent retrograde cold blood cardioplegia (lRCBC). Material and Method: From April 2001 to Feb. 2003, fifty seven patients who underwent isolated coronary surgery were divided into two groups (IAWBC vs. IRCBC). The two group had similar demographic and angiographic characteristics. There were no statistical differences in age, sex, Canadian Cardiovascular Society Functional Classification for angina, ejection fraction, and number of grafts. Result: Aortic cross clamping time and total pump time in IAWBC (99$\pm$23 and vs. 126$\pm$32 min) were shorter than those of IRCBC (118$\pm$32 min. and 185$\pm$48 min.)(p<0.05). The reperfusion time (13$\pm$7 min) in IAWBC was shorter than that of IRCBC (62$\pm$109 min.)(p<0.05). CKMB at 12 hours and 24 hours (16$\pm$15 and 9$\pm$13) in IAWBC was lower than that of IRCBC (33$\pm$47 and 17$\pm$26)(p<0.05). The awakening time in IAWBC (2$\pm$1 hour) was shorter than that of IRCBC (4$\pm$3)(p<0.05). The number of spontaneous heart beat recovery in IAWBC (85%) was more than that of IRCBC (35%)(p<0.05). The cardiac index after discontinuing cardio-pulmonary bypass was significantly elevated in the IAWBC group. The prevalence of perioperative myocardial infarction in IAWBC (4%) was lower than that of IRCBC group (20%)(p<0.05). Conclusion: Intermittent antegrade warm blood cardioplegia is a safe, reliable, and effective technique for myocardial protection. It can also provide simpler and economic way than the retrograde cold cardioplegia by shortening of cardiopulmonary bypass time and avoiding retrograde cannulation for coronary sinus.

Effect of Magnesium Administration on Preventing Arrhythmias after Coronary Artery Bypass Graft (관상동맥 우회술 후 마그네슘 투여가 심 부정맥을 예방하는 효과)

  • Kim, Jun-Hyun;Song, Hyun;Kim, Yong-Hee;Lee, Eun-Sang;Lee, Jay-Won;Song, Myung-Kun
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.339-345
    • /
    • 1998
  • Arrhythmias are common after cardiac surgery and are multifactorial. Intravenous magnesium administration reduces the frequency of ventricular arrhythmias in patient with symptomatic heart failure or acute myocardial infarction. This study was designed to evaluate the role of magnesium in preventing PVCs(premature ventricular contractions) occurred frequently after coronary artery bypass graft(CABG). 50 consecutive patients were prospectively entered into a randomized trial to determine the efficacy of postoperative magnesium therapy on the incidence of cardiac arrhythmias after elective coronary artery bypass graft. The patients underwent coronary angiography, echocardiography, electrocardiography and clinical laboratory study preoperatively. Continuous electrocardiographic monitoring was done and magnesium level was checked 0, 3, 6, 12, 18, 24, 36, 48, 60 and 72 hours postoperatively. Study group of 25 patients were given 4g of magnesium continuously over the first 24 hours and then 2g/24hours from 25 to 72 hours. The clinical characteristics of both groups were similar(p<0.05). The preoperative mean serum magnesium concentration was similar in both study group, 1.59mg/dl and control group, 1.71mg/dl. The mean postoperative serum magnesium concentration in study group elevated significantly over postoperative 12hours through 36hours(p<0.05). The postoperative mean serum magnesium concentration in control group declined and remained significantly depressed over immediate postoperation through 72hours. The mean serum magnesium concentration was significantly greater in the study group compared with the control group over postoperative 3hours through 72hours(p<0.05). There was a significant decrease in the incidence of arrhythmias such as PVCs(p<0.01) which might jeopardize hemodynamics. There were no recognized adverse effects of magnesium Administration. In conclusion, prophylactic magnesium administration seems to lessen the incidence and severity of rrhythmias after coponary artery bypass graft.

  • PDF

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

Mid-Term Results of 292 cases of Coronary Artery Bypass Grafting (관상동맥 우회술 292례의 중기 성적)

  • 김태윤;김응중;이원용;지현근;신윤철;김건일
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.643-652
    • /
    • 2002
  • As the prevalence of coronay artery disease is increasing, the surgical treatment has been universalized and operative outcome has been improved. We analyzed the short and mid-term results of 292 CABGs performed in Kangdong Sacred Heart Hospital. Material and Method: From June 1994 to December 2001, 292 patients underwent coronary artery bypass grafting. There were 173 men and 119 women and their ages ranged from 39 to 84 years with a mean of $61.8{\pm}9.1$ years. We analyzed the preoperative risk factors, operative procedures and operative outcome. In addition, we analyzed the recurrence of symptoms, long-term mortality and complications via out-patient follow-up for discharged patients. Result: Preoperative clinical diagnoses were unstable angina in 137(46.9%), stable angina in 34(11.6%), acute myocardial infarction in 40(13.7%), non-Q myocardial infarction in 25(8.6%), postinfarction angina in 22(7.5%), cardiogenic shock in 30(10.3%) and PTCA failure in 4(1.4%) patients. Preoperative angiographic diagnoses were three-vessel disease in 157(53.8%), two-vessel disease in 35 (12.0%), one-vessel disease in 11(3.8%) and left main disease in 89(30.5%) patients. We used saphenous veins in 630, internal thoracic arteries in 257, radial arteries in 50, and right gastoepiploic arteries in 2 distal anastomoses. The mean number of distal anastomoses per patient was $3.2{\pm}1.0$ There were 18 concomitant procedures ; valve replacement in 8(2.7%), left main coronary artery angioplasty in 6(2.1%), patch closure of postinfarction ventricular septal defect(PMI-VSD) in 2(0.7%), replacement of ascending aorta in 1(0.3%) and coronary endarterectomy in 1(0.3%) patient. The mean ACC time was $96.6{\pm}35.3 $ minutes and the mean CPB time was $179.2{\pm}94.6$ minutes. Total early mortality was 8.6%, but it was 3.1% in elective operations. The most common cause of early mortality was low cardiac output syndrome in 6(2.1%) patients. The stastistically significant risk factors for early mortality were hypertension, old age($\geq$ 70 years), poor LV function(EF<40%), congestive heart failure, preoperative intraaortic balloon pump, emergency operation and chronic renal failure. The most common complication was arrhythmia in 52(17.8%) patients. The mean follow-up period was $39.0{\pm}27.0$ months. Most patients were free of symptoms during follow-up. Fourteen patients(5.8 %) had recurrent symptoms and 7 patients(2.9%) died during follow-up period. Follow-up coronary angiography was performed in 13 patients with recurrent symptoms and they were managed by surgical and medical treatment according to the coronary angiographic result. Conclusion: The operative and late results of CABG in our hospital, was acceptable. However, There should be more refinement in operative technique and postoperative management to improve the results.