• Title/Summary/Keyword: CA therapy

Search Result 247, Processing Time 0.026 seconds

Menadione (Vitamin K3) Induces Apoptosis of Human Oral Cancer Cells and Reduces their Metastatic Potential by Modulating the Expression of Epithelial to Mesenchymal Transition Markers and Inhibiting Migration

  • Suresh, Shruthy;Raghu, Dinesh;Karunagaran, Devarajan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5461-5465
    • /
    • 2013
  • Oral cancer is one of the most commonly occurring cancers worldwide, decreasing the patient's survival rate due to tumor recurrence and metastasis. Menadione (Vitamin K3) is known to exhibit cytotoxicity in various cancer cells but the present study focused on its effects on viability, apoptosis, epithelial to mesenchymal transition (EMT), anchorage independent growth and migration of oral cancer cells. The results show that menadione is more cytotoxic to SAS (oral squamous carcinoma) cells but not to non-tumorigenic HEK293 and HaCaT cells. Menadione treatment increased the expression of pro-apoptotic proteins, Bax and p53, with a concurrent decrease in anti-apoptotic proteins, Bcl-2 and p65. Menadione induced the expression of E-cadherin but reduced the expression of EMT markers, vimentin and fibronectin. Menadione also inhibited anchorage independent growth and migration in SAS cells. These findings reveal and confirm that menadione is a potential candidate in oral cancer therapy as it exhibits cytotoxic, antineoplastic and antimigratory effects besides effectively blocking EMT in oral cancer cells.

Controversial Effect of Ethanol Irrespective of Kinases Inhibition on the Agonist-Dependant Vasoconstriction

  • Je, Hyun-Dong;Kim, Hyeong-Dong;Park, June-Hong
    • Biomolecules & Therapeutics
    • /
    • v.20 no.3
    • /
    • pp.352-356
    • /
    • 2012
  • The present study was undertaken to determine whether ethanol influences on the agonist-induced vascular smooth muscle contraction and, if so, to investigate the related mechanism. The measurement of isometric contractions using a computerized data acquisition system was combined with molecular experiments. Ethanol significantly inhibited thromboxane $A_2$ mimetic-induced contraction with intact endothelial function, but there was no relaxation on thromboxane $A_2$ mimetic U-46619-induced contraction irrespective of endothelium suggesting that the pathway such as Rho-kinase activation, $Ca^{2+}$ entry or thin filament regulation was not affected. In addition, ethanol didn't decrease thromboxane $A_2$ mimetic-induced increase of phospho-myosin phosphatase targeting subunit protein 1 (pMYPT1) or pERK1/2. Interestingly, ethanol didn't inhibit significantly phorbol ester-induced contraction in denuded muscles suggesting that thin filament regulation is less important on the ethanol-induced regulation in the muscle than endothelial NO synthesis. In conclusion, this study provides the evidence and possible related mechanism concerning the effect of ethanol on the agonist-dependent contraction in rat aortic rings with regard to endothelial function.

The Effect of the Forced Pulmonary Function of young female, by Changes in Lung function Related to Postures and by Transverse Abdominis Activation in Standing Position (자세에 따른 폐기능의 변화와 기립자세에서의 복횡근의 수축이 노력성 폐기능에 미치는 영향)

  • Lee, Byung-Ki
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.3
    • /
    • pp.267-274
    • /
    • 2012
  • Purpose : The purpose of this study was to investigate characteristics of the forced pulmonary function test effect by changes in lung function related to postures and by Transverse Abdominis(TrA). Contraction in standing position during forced inspiration and expiration with young female adults. Methods : 10 young female adults were recruited this study. pulmonary Function test was measured with a Master-screen Body (VIASYS Inc., CA, 미국). To check the changes in lung function with different postures, we tested pulmonary function in the standing and supine position each. In the standing position, while the transversus abdominis was activating, we compared the forced inspiration with the forced expiration. Statistical analysis was used Independent t-test to know difference between forced inspiration and expiration of activated TrA. Results : According to the study, the change of pulmonary function were statistically significant difference in the standing compared to the supine position. The contraction of the transversus abdominis causes decrease in the change of forced inspiration and increase in the change of forced expiration. Conclusion : These results indicate that spontaneous contraction of the TrA in standing position helps pulmonary function. And the selective contraction of the transversus abdominis at the end of forced inspiration makes increases in the forced expiration.

Acupuncture for Endometriosis; A Systemic Review (자궁내막증의 침치료 효과에 대한 체계적 문헌 고찰)

  • Kwon, Na-Yoen;Lee, Dong-Nyung
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.34 no.2
    • /
    • pp.48-61
    • /
    • 2021
  • Objectives: This study was aimed to review the effect of acupuncture on endometriosis related pain in patients. Methods: Researchers searched data through 6 online databases up to November 2020. The data was limited to randomized controlled trial studies on endometriosis patients diagnosed with laparoscopy. Results: 7 Randomized controlled trials were included in this study. All of studies were published in Chinese, in China. Intervention of treatment group were composed of simple acupuncture and electroacupuncture. Intervention of control group were made up with mifepristone, herbal medicine and acupuncture. Outcome measurements were effective rate, serum Cancer antigen-125 (CA-125), Visual analogue scale (VAS)/pain score, and recurrence rate in 1 year. In all outcome measurements, treatment group were more effective than control group and it was statistically significant. Conclusions: Acupuncture therapy is effective in decreasing endometriosis related pain and preventing recurrence. However, because endometriosis is easy to recur, additional long-term research is needed.

The Effect of a Home Visit Cognitive Training Program Using Tablet-Based Recognition Rehabilitation Application (Brain Doctor) on Local Elderly People's Cognitive Function and Depression (태블릿 PC형 전산화 인지재활 프로그램(Brain doctor)을 이용한 가정방문 인지훈련 프로그램이 지역사회 노인의 인지기능 및 우울감에 미치는 영향)

  • Kim, Minho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.49-58
    • /
    • 2020
  • Purpose : This study examined the effect of a home visit cognitive training program that uses a tablet-based digital recognition rehabilitation application, Brain Doctor, on local elderly people's cognitive function and depression. Methods : This study featured 20 elderly people living in Busan Metropolitan City, South Korea, who received a voucher for a home visit service to prevent dementia. The subjects were evenly divided into an intervention group provided with Brain Doctor and a control group provided with a conventional cognitive training program. Korean version of Mini Mental State Examination (MMSE-K) and Korean version of Montreal Cognitive Assessment (K-MoCA) were used to assess cognitive function in each group. Patient Health Questionnaire-9 (PHQ-9) was used to evaluate the depression levels. Results : The intervention group showed a significant change in cognitive function and depression after the intervention (p<.05). There was a statistically significant change in cognitive function and depression between the intervention and control groups (p<.05). Conclusion : This study confirmed that Brain Doctor had a positive effect on the cognitive function and depression of elderly people in the local community. It is expected to become a useful home visit program for dementia prevention in the future.

Glycine induces enhancement of bactericidal activity of neutrophils

  • Kang, Shin-Hae;Ham, Hwa-Yong;Hong, Chang-Won;Song, Dong-Keun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.26 no.4
    • /
    • pp.229-238
    • /
    • 2022
  • Severe bacterial infections are frequently accompanied by depressed neutrophil functions. Thus, agents that increase the microbicidal activity of neutrophils could add to a direct antimicrobial therapy. Lysophosphatidylcholine augments neutrophil bactericidal activity via the glycine (Gly)/glycine receptor (GlyR) α2/TRPM2/p38 mitogen-activated protein kinase (MAPK) pathway. However, the direct effect of glycine on neutrophil bactericidal activity was not reported. In this study, the effect of glycine on neutrophil bactericidal activity was examined. Glycine augmented bactericidal activity of human neutrophils (EC50 = 238 μM) in a strychnine (a GlyR antagonist)-sensitive manner. Glycine augmented bacterial clearance in mice, which was also blocked by strychnine (0.4 mg/kg, s.c.). Glycine enhanced NADPH oxidase-mediated reactive oxygen species (ROS) production and TRPM2-mediated [Ca2+]i increase in neutrophils that had taken up E. coli. Glycine augmented Lucifer yellow uptake (fluid-phase pinocytosis) and azurophil granule-phagosome fusion in neutrophils that had taken up E. coli in an SB203580 (a p38 MAPK inhibitor)-sensitive manner. These findings indicate that glycine augments neutrophil microbicidal activity by enhancing azurophil granule-phagosome fusion via the GlyRα2/ROS/calcium/p38 MAPK pathway. We suggest that glycine could be a useful agent for increasing neutrophil bacterial clearance.

A Case of Microscopic Polyangiitis with Pulmonary Hemorrhage and Rapidly Progressive Glomerulonephritis (폐출혈과 급속 진행성 사구체신염을 동반한 현미경적 다발성 동맥염 (Microscopic Polyangiitis) 1례)

  • Kwon Hae Sik;Lee Young-Mock;Kim Ji Hong;Kim Pyung-Kil;Kang Hae Youn;Hong Soon Won;Jeong Hyeon Joo
    • Childhood Kidney Diseases
    • /
    • v.5 no.2
    • /
    • pp.213-218
    • /
    • 2001
  • Microscopic Polyangiitis(MPA) belongs to a spectrum of systemic vasculits, and particularly antineutrophil cytoplasmic autoantibodies(ANCA)-associated small-vessel vasculitis which is characterized by involvement of the lung and kidney. The diagnosis of MPA is often difficult to make, and delayed because of the variability of the clinical presentation. Renal biopsies have a very important diagnostic and prognostic value in MPA. We experienced a case of microscopic polyangiits which was confirmed by renal biopsy and positive serum perinuclear ANCA, associated with alveolar hemorrhage and gastrointestinal bleeding. We began methylprednisolone pulse therapy, combined with a low dose of cyclophosphamide and plasmapheresis therapy. ACE inhibitor and Ca channel blocker were used when proteinuria and hypertention developed. On admission, the patient's lab findings showed BUN l17 mg/dL, Cr 2.3 mg/dL, while on the 60th hospital day BUN/Cr values fell to 20.8 mg/dL / 1.6 mg/dL and though proteinuria persisted, the patient's condition was tolerable and is currently under observation on an out-patient basis. The last lab values were BUN 26 mg/dL / Cr 1.6 mg/dL. (J. Korean Soc Pediatr Nephrol 2001 ; 5 : 213-18)

  • PDF

Planning Aspects of Volumetric Modulated Arc Therapy and Intensity Modulated Radio therapy in Carcinoma Left Breast - A Comparative Study

  • Ekambaram, Varadharajan;Velayudham, Ramasubramanian;Swaminathan, Shiyama;Loganathan, Padmanabhan;Swaminathan, Vijaya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1633-1636
    • /
    • 2015
  • Background: The advantages of Rapid Arc plans versus Intensity modulated radiotherapy plans for Carcinoma left breast were analyzed. Materials and Methods: In this study 20 Post mastectomy carcinoma left breast patients were analyzed. Both Intensity modulated Radiotherapy and Rapid Arc plans were generated for these patients. IMRT plans with 7 beams in an arc fashion and VMAT plans with two semi arcs were made to achieve 95% dose coverage to 100% volume. The plans were evaluated using Dose volume Histograms. Results: The mean Conformity and Homogeneity index in VMAT is found to be 1.05 and 0.065 respectively whereas in IMRT it was 1.07 and 0.069. The 20% volume of Heart received a mean dose of 960cGy in VMAT and 1300cGy in IMRT. The mean dose was 1236cGy in VMAT and 1870cGy in IMRT. The ipsilateral Lung received 3395cGy to 5% volume and 1840cGy to 20% volume on an average and the mean dose was 1205cGy in VMAT, while the same were found to be 3525cGy, 2012cGy and 1435cGy respectively in IMRT. The Contralateral Lung received a mean dose of 505cGy in VMAT and 553cGy in IMRT. The mean Monitor units in VMAT were 512MU and 1170MU in IMRT. The NTID in VMAT is $108.8{\times}10^5Gycm^3$ and $110.1{\times}10^5Gycm^3$ in IMRT. Conclusions: The target coverage, homogeneity and Conformity index were better in VMAT plans. The Ipsilateral Lung and heart dose were very less in VMAT plans. The Contralateral Lung dose and the Normal Tissue Integral Dose were also lesser in VMAT plans however the difference is not very appreciable. The MU in VMAT plans is almost 50% that of the IMRT plans which results in the reduction of treatment time. On the whole VMAT proves to be a better modality for treating Ca. Left Breast Patients.

Dosimetric effects of couch attenuation and air gaps on prone breast radiation therapy (Prone Breast Phantom을 이용한 couch 산란영향 평가)

  • Kim, Min Seok;Jeon, Soo Dong;Bae, Sun Myeong;Baek, Geum Mun;Song, Heung Gwon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the dosimetric effects of couch attenuation and air gaps using 3D phantom for prone breast radiation therapy. Materials and method: A 3D printer(Builder Extreme 1000) and computed tomography (CT) images of a breast cancer patient were used to manufacture the customized breast phantom. Eclipse External Beam Planning 13.6 (Varian Medical Systems Palo Alto, CA, USA) was used to create the treatment plan with a dose of 200 cGy per fraction with 6 MV energy. The Optically Stimulated Luminescence Detector(OSLD) was used to measure the skin dose at four points (Med 1, Med 2, Lat 1, Lat 2) on the 3D phantom and ion-chamber (FC65-G) were used to perform the in-vivo dosimetry at the two points (Anterior, Posterior). The Skin dose and in-vivo dosimetry were measured with reference air gap (3 cm) and increased air gaps (1, 2, 3, 4, 5, 6 cm) from reference distance between the couch and 3D phantom. Results: As a result, measurement for the skin dose at lateral point showed a similar value within ${\pm}4%$ compared to the plan. While the air gap increased, skin dose at medial 1 was reduced. And it was also reduced over 7 % when the air gap was more than 3 cm compared to radiation therapy plan. At medial 2 it was reduced over 4 % as well. The changes of dose from variety of the air gap showed similar value within ${\pm}1%$ at posterior. As the air gap was increased, the dose at anterior was also increased and it was increased by 1 % from the air gap distance more than 3 cm. Conclusion: Dosimetrical measurement using 3D phantom is very useful to evaluate the dosimetric effects of couch attenuation and air gaps for prone breast radiation therapy. And it is possible to reduce the skin dose and increase the accuracy of the radiation dose delivery by appling the optimized air gap.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.