• Title/Summary/Keyword: C3H

Search Result 25,067, Processing Time 0.069 seconds

Studies on the In Vitro Development of Cloned Embryos by Somatic Cell Nuclear Transfer in Korean Native Goats (재래산양의 체세포 핵이식에 의한 복제수정란의 체외발달에 관한 연구)

  • Park H. S.;Kim T. S.;Jung S. Y.;Lee Y. H.;Jung J. Y.
    • Journal of Embryo Transfer
    • /
    • v.20 no.2
    • /
    • pp.105-112
    • /
    • 2005
  • The present study was conducted to examine some factors affecting in vitro development of oocytes from somatic cell nuclear transfer (SCNT) in Korean native goats. Recipient oocytes were surgically collected after superovulation by using CIDR and FSH, PMSG, hCG and estrous synchronization in Korean Native goats. For nuclear transfer, the fibroblasts from caprine ear cells and fetal fibroblasts were surgically harvested and were cultured in vitro until cell confluency in serum-starvation condition (TCM-199 + $0.5\%$ FBS) for 3 to 5 days. The zona pellucidae of matured oocytes were partially drilled by laser irradiation. A single somatic cell was individually transferred into each enucleated oocyte. The reconstructed oocytes were then electrically fused and activated. Activated NT embryos were cultured in mSOF medium supplemented with $0.8\%\;BSA\;6\~7\;day\;at\;39^{\circ}C,\;5\%\;CO_2,\;5\%\;O_2,\;90\%\;N_2$ in air. There were no significant difference in the number of embryos cleaved and 4-cell development between the fibroblast nuclei from mature ear cells and fetal cells, but the rate of 8-cell development was higher (P<0.05) in ear cells $(40.5\%)$ than in fetal cells $(55.5\%)$. However, the embryo development to morula or blastocyst was not significantly different between both the groups$(6.7\%\;vs\;16.0\%)$, respectively. The number of embryo cleaved $(79.0\%)$ were higher (P<0.05) in the oocytes activated with ionomycin+6-DMAP than in the oocytes activated electrically $(9.5\%)$. The development of fused embryos to morula or blastocyst was found $15.6\%$ in ionomycin+6-DMAP, but no morula or blastocysts were developed in electrical stimulation. The development rate of SCNT embryos to morula or blastocyst was love. (P<0.05) in SCNT embryos $(19.0\%\;vs\;0.0\%)$ than that in parthenotes $(66.1\%\;vs\;59.1\%)$. In the parthenotes, the cleavage rate and development to morula or blastocyst were significantly higher (P<0.05) as $86.8\%\;and\;50.0\%$ in ovulated oocytes than in follicular oocytes $(69.0\%\;vs\;23.6\%)$, respectively. These results suggest that some factors Including superovulation treatment, oocyte source, maturation of follicular oocytes, activation method and culture condition may affect in vitro developmental capability of embryos produced by somatic cell nuclear transfer in Korean Native goats, and the fusion rate be greatly low compared with other species.

The Radioprotective Effect of Ginseng Extracts on the liver in Mice that was irradiated by radiation (방사선이 조사된 생쥐 간에서 인삼추출물이 방사선 방어효과에 미치는 영향)

  • Ko, In-Ho;Chang, Chae-Chul;Koh, Jeong-Sam
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.35-43
    • /
    • 2004
  • Radioprotective effects of ginseng extracts on liver damage induced by high energy x-ray were studied. To one group of ICR male mice were given white(50 mg/kg/day for 7days, orally) and fermenta ginseng extracts(500 mg/kg/day for 7days, orally) before irrdiation. To another group were irradiated by 5 Gy dose of high energy x-ray. Contrast group were given with saline(0.1 ml). This study also investigated the radioprotective effect between SOD, CAT, hydrogen peroxide and ginseng extracts on hepatic damage. This study measured the level of superoxide dismutase(SOD), catalase(CAT), hydrogen peroxide($H_2O_2$) in liver tissue. Administrating orally white (50 mg/kg/day for 7days, orally) and fermenta ginseng extracts(500 mg/kg/day), the activity of SOD, CAT were generally increased and the hydrogen peroxide($H_2O_2$) was decreased. After irradiation, the activity of SOD, CAT were generally decreased and the hydrogen peroxide($H_2O_2$) was increased. Therefore, ginseng extracts increased antioxidative enzyme activity. And We know that the antioxidatant effect of extracts from white and fermenta ginseng protect radiation damage by direct antioxidant effect involving SOD, CAT. It was included that ginseng can protect against radiation damage through its antioxidatant properties.

  • PDF

Changes of Quality Characteristics on the Bread added Chitosan (키토산 첨가에 따른 식빵의 품질 변화)

  • Lee, Hyun-Young;Kim, Seong-Mi;Kim, Jin-Young;Youn, Sun-Kyoung;Choi, Jung-Su;Park, Sun-Mee;Ahn, Dong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.449-453
    • /
    • 2002
  • This was studied to evaluate the quality characteristics of the bread added chitosan during storage at room temperature(Temp. $27^{\circ}C{\pm}2$, RH $75%{\pm}10$). The volume of the dough was increased depending on the larger molecular weight and the higer concentration of chitosan but was decreased at 0.50% of 120 kDa chitosan. The water activity was low depending on the larger molecular weight and the higher concentration of chitosan at the early storage, but maintained constantly during storage totally. The colors of the bread was hardly affected by 30 kDa of chitosan. Textural characteristics was improved at 30 kDa and 120 kDa of chitosan. Especially, the change of the hardness were maintained lower at 30 kDa, 120 kDa of chitosan during storage than that of standard. These results showed that the quality of the bread by added 30 kDa of chitosan was improved highly.

A Study on groundwater and pollutant recharge in urban area: use of hydrochemical data

  • Lee, Ju-Hee;Kwon, Jang-Soon;Yun, Seong-Taek;Chae, Gi-Tak;Park, Seong-Sook
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.119-120
    • /
    • 2004
  • Urban groundwater has a unique hydrologic system because of the complex surface and subsurface infrastructures such as deep foundation of many high buildings, subway systems, and sewers and public water supply systems. It generally has been considered that increased surface impermeability reduces the amount of groundwater recharge. On the other hand, leaks from sewers and public water supply systems may generate the large amounts of recharges. All of these urban facilities also may change the groundwater quality by the recharge of a myriad of contaminants. This study was performed to determine the factors controlling the recharge of deep groundwater in an urban area, based on the hydrogeochemical characteristics. The term ‘contamination’ in this study means any kind of inflow of shallow groundwater regardless of clean or contaminated. For this study, urban groundwater samples were collected from a total of 310 preexisting wells with the depth over 100 m. Random sampling method was used to select the wells for this study. Major cations together with Si, Al, Fe, Pb, Hg and Mn were analyzed by ICP-AES, and Cl, N $O_3$, N $H_4$, F, Br, S $O_4$and P $O_4$ were analyzed by IC. There are two groups of groundwater, based on hydrochemical characteristics. The first group is distributed broadly from Ca-HC $O_3$ type to Ca-C1+N $O_3$ type; the other group is the Na+K-HC $O_3$ type. The latter group is considered to represent the baseline quality of deep groundwater in the study area. Using the major ions data for the Na+K-HC $O_3$ type water, we evaluated the extent of groundwater contamination, assuming that if subtract the baseline composition from acquired data for a specific water, the remaining concentrations may indicate the degree of contamination. The remainder of each solute for each sample was simply averaged. The results showed that both Ca and HC $O_3$ represent the typical solutes which are quite enriched in urban groundwater. In particular, the P$CO_2$ values calculated using PHREEQC (version 2.8) showed a correlation with the concentrations of maior inorganic components (Na, Mg, Ca, N $O_3$, S $O_4$, etc.). The p$CO_2$ values for the first group waters widely ranged between about 10$^{-3.0}$ atm to 10$^{-1.0}$ atm and differed from those of the background water samples belonging to the Na+K-HC $O_3$ type (<10$^{-3.5}$ atm). Considering that the p$CO_2$ of soil water (near 10$^{-1.5}$ atm), this indicates that inflow of shallow water is very significant in deep groundwaters in the study area. Furthermore, the P$CO_2$ values can be used as an effective parameter to estimate the relative recharge of shallow water and thus the contamination susceptibility. The results of our present study suggest that down to considerable depth, urban groundwater in crystalline aquifer may be considerably affected by the recharge of shallow water (and pollutants) from an adjacent area. We also suggest that for such evaluation, careful examination of systematically collected hydrochemical data is requisite as an effective tool, in addition to hydrologic and hydrogeologic interpretation.ion.ion.

  • PDF

Quality Properties of the Refrigerated or Frozen Irradiated Beef Patty (방사선조사된 패티용 분쇄우육의 가열전 품질특성)

  • Jeon, Ki-Hong;Oh, Se-Wook;Lee, Nam-Hyouck;Kim, Yun-Ji;Park, Ki-Jae;Kim, Young-Ho
    • the MEAT Journal
    • /
    • s.36 summer
    • /
    • pp.72-86
    • /
    • 2009
  • Microbial reduction, physicochemical property, and sensory evaluation of irradiated beef patty were investigated. The microbial counts of refrigerated beef patty were reduced to below the number of 3 logs after irradiation at 3 kGy. But no viable microorganism was detected in frozen beef patty irradiated at 3 kGy. Food additives such as nitrite, salt, phosphate and ascorbic acid did not affect on the inactivation of microorganism by irradiation. The irradiation effect on the water holding capacity was not significant, but frozen irradiated beef patty showed higher water holding capacity than refrigerated beef patty. The drip loss of irradiated beef patty did not show significant differences according to irradiation doses. Considering the influence of food additives, the irradiated beef patty mixed with salt and phosphate showed lower drip loss than that without food additives. In refrigerated beef patty, TBARS values were increased with increase of irradiation doses and showed lower values in the beef patty mixed with food additives than that without food additives. The redness of refrigerated beef patty showed highest values at 3 kGy of irradiation and then decreased with increasing irradiation doses, while in the frozen beef patty did not show distinct tendency according to the irradiation doses or food additives. In sensory evaluation. the irradiated beef patty showed unpleasant smell as compared with the non irradiated beef patty, but showed somewhat higher score in smell at the sample contained ascorbic acid regardless of irradiation doses.

  • PDF

Effect of Feeding High Guality Hay on Performance and Physico-chemical Characteristics of Carcass of Hanwoo Steers (양질의 건초 급여가 한우 거세우의 비육성적 및 도체의 이화학적 특성에 미치는 영향)

  • Kim, S.I.;Jung, K.K.;Kim, J.Y.;Lee, S.W.;Baek, K.H.;Choi, C.B.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.6
    • /
    • pp.783-800
    • /
    • 2007
  • The current study was conducted to investigate the effect of high quality hay on the performance and carcass characteristics of Hanwoo steers. Twenty(20) Hanwoo(7 months old) were allocated into either Control(rice straw fed) or Treatment(timothy hay and rice straw fed) group(10 animals per group) and fed for 710 days until the animals reached at 30 months old. Concentrates were fed according to the feeding program composed with three(3) phases; growing, fattening, and finishing period. For the overall feeding period, final body weights were 761.3 and 799.6kg for the Control and Treatment groups, respectively, showing 38.3kg heavier body weight in Treatment group. ADG were 0.79 and 0.84kg for Control Treatment groups, respectively. These results might be because of the intake of high quality hay during growing phase and the effects persisted until the end of the experiment. Feed intake tended to be higher in Treatment group whereas feed conversion did not show significant difference between groups. Cold carcass weights were 451.0 and 475.3kg for Control and Treatment, There were no significant difference between groups in both yield and quality grade. There were no remarkable differences in physico-chemical characteristics fatty acid composition of carcasses between groups. In conclusion, it would be beneficial to feed high quality hay such as timothy during growing period of Hanwoo steers to produce high quality beef with heavier live and carcass weight.

Studies on the Nitrate Concentration, Sugar Content and Intake of Four Sorghum X Sudangrass Hybrids Grown under Application of Animal Manure (가축분 시용조건에서 4종 수수 X 수단그라 교잡종의 질산태질소 함량과 당도 및 채식률 비교 연구)

  • Seo, S.;Kim, J.G.;Chung, E.S.;Shin, D.E.;Lim, Y.C.;Yoon, S.H.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.22 no.2
    • /
    • pp.131-136
    • /
    • 2002
  • A field experiment was carried out to compare the nitrate nitrogen concentration, sugar content and animal intake of low $sorghum{\times}sudangrass$ hybrids (Sorghum bicolor (L.) Moench) grown under application of animal manure in 1995. The application amount of animal manure were 40MT in cattle manure, and 30MT/ha in swine and poultry manure. The four NLCF's recommended hybrids used in this study were Pioneer 988, TE-Haygrazer and NC+ 855 (heading type), and Jumbo(headless type). The nitrate nitrogen concentration of forage was 365mg/kg at 50~60cm of plant height, 501mg at 100~120cm, and 502mg at 200~220cm, regardless of animal manure type and cultivar. The nitrate nitrogen concentration of NC+ 855 and P 988 was 519 and 526mg, respectively, and were higher than that(317mg) of Jumbo(P<0.05). The nitrate nioogen concentration of stems was 376mg, and significantly higher than that(135mg) of leaves(P<0.05) regardless of cultivar, and lower parts of stems and leaves were higher than those of upper parts of plants. The sugar contents of four $sorghum{\times}sudangrass$ hybrids were ranged between 3.1 and $3.7^{\circ}$ in cattle manure, 2.9 and $3.3^{\circ}$ in swine manure, and 2.8 and $4.9^{\circ}$ in poultry manure. The sugar content of NC+ 855 was the highest as $3.9^{\circ}$, p 988 was second as $3.4^{\circ}$, and then TE-Haygrazer and Jumbo were lower as $3.2^{\circ}$ and $2.9^{\circ}$, respectively. Animal intake of sorghum ${\times}$ sudangrass hybrids P 988 and NC+ 855 were slightly higher than those of Jumbo and TE-Haygrazer grown under application of cattle manure. Also the average intake of P 988 was a little higher than that of Jumbo. However, there were no significant differences of forage intake among few recommended $sorghum{\times}sudangrass$ hybrids.

Establishment of an Analytical Method for Novobiocin in Livestock Products Using HPLC-UVD (HPLC-UVD를 이용한 축산식품 중 Novobiocin의 시험법 확립)

  • Park, Hee-Ra;Kwon, Chan-Hyeok;Lee, Jong-Goo;Kim, Hyung-Soo;Chae, Young-Sik;Oh, Jae-Ho;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • Novobiocin is a coumarin-containing antibiotic, and has a longer half-life in various animals than other veterinary medicines. A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in chicken, beef and milk has been developed and validated. The separation condition for HPLC/UVD was optimized by a MG II $C_{18}$ (4.6 mm $ID{\times}250$ mm, 5 ${\mu}m$) column with 0.1% formic acid in $H_2O$/0.1% formic acid in Acetonitrile (40/60, v/v) as the mobile phase at a flow rate of 1.0 mL/min and the detection wavelength was set at 340 nm. Residues were extracted from tissue by blending with methanol. After liquid-liquid partitioning, lipid materials were removed with n-hexane and purification as Silica (1 g, 6 mL) cartridge with 10 mL acetone/dichloromethane (10/90, v/v). Limit of quantification and linearity performed by the analytical method were 0.02 mg/kg and 0.999 ($r^2$), and the recovery range was $88.8{\pm}5.6-100.3{\pm}4.4$, $88.8{\pm}7.2-97.0{\pm}3.2$ and $88.1{\pm}4.3-92.8{\pm}3.6%$. It is expected that this analytical method with regards to novobiocin in chicken, beef and milk could be applied as an official method to administer food safety on veterinary medicines.

Quality Properties of the Refrigerated or Frozen Irradiated Beef Patty (방사선조사된 패티용 분쇄우육의 가열전 품질특성)

  • Jeon, Ki-Hong;Oh, Se-Wook;Lee, Nam-Hyouck;Kim, Yun-Ji;Park, Ki-Jae;Kim, Young-Ho
    • Food Science of Animal Resources
    • /
    • v.28 no.4
    • /
    • pp.437-444
    • /
    • 2008
  • Microbial reduction, physicochemical property, and sensory evaluation of irradiated beef patty were investigated. The microbial counts of refrigerated beef patty were reduced to below the number of 3 logs after irradiation at 3 kGy. But no viable microorganism was detected in frozen beef patty irradiated at 3 kGy. Food additives such as nitrite, salt, phosphate and ascorbic acid did not affect on the inactivation of microorganism by irradiation. The irradiation effect on the water holding capacity was not significant, but frozen irradiated beef patty showed higher water holding capacity than refrigerated beef patty. The drip loss of irradiated beef patty did not show significant differences according to irradiation doses. Considering the influence of food additives, the irradiated beef patty mixed with salt and phosphate showed lower drip loss than that without food additives. In refrigerated beef patty, TBARS values were increased with increase of irradiation doses and showed lower values in the beer patty mixed with food additives than that without food additives. The redness of refrigerated beef patty showed highest values at 3 kGy of irradiation and then decreased with increasing irradiation doses, while in the frozen beef patty did not show distinct tendency according to the irradiation doses or food additives. In sensory evaluation, the irradiated beef patty showed unpleasant smell as compared with the non irradiated beef patty, but showed some-what higher score in smell at the sample contained ascorbic acid regardless of irradiation doses.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF