• 제목/요약/키워드: C2 laminar screw

검색결과 6건 처리시간 0.019초

Modified Trajectory of C2 Laminar Screw-Double Bicortical Purchase of the Inferiorly Crossing Screw

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권2호
    • /
    • pp.119-122
    • /
    • 2008
  • The crossing laminar screw fixation might be the most recently developed approach among various fixation techniques for C2. The new construct has stability comparable to transarticular or transpedicular screw fixation without risk of vertebral artery injury. Quantitative anatomical studies about C2 vertebra suggest significant variation in the thickness of C2 lamina as well as cross sectional area of junction of lamina and spinous process. We present an elderly patient who underwent an occipito-cervical stabilization incorporating crossed C2 laminar screw fixation. We preoperatively recognized that she had low profiles of C2 lamina, and thus made a modification of trajectory for the inferiorly crossing screw. We introduce a simple modification of crossing C2 laminar screw technique to improve stability in patients with low laminar profiles.

Posterior Atlantoaxial Fixation with a Combination of Pedicle Screws and a Laminar Screw in the Axis for a Unilateral High-riding Vertebral Artery

  • Kim, Sei-Yoon;Jang, Jee-Soo;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.141-144
    • /
    • 2007
  • A vertebral arte [VA] injury presents a difficult problem in atlantoaxial fixation. Recent technical reports described posterior C2 fixation using bilateral, crossing C2 laminar screws. The translaminar screw technique has the advantages of producing little risk of VA injury and the unconstrained screw placement. In addition, biomechanical studies have demonstrated the potential of the translaminar screw technique to provide a firmer construct that is equivalent to methods currently used. We report the successful treatment of C1-2 instability with a left-side high-riding VA. Because of the potential risk of VA injury, we performed a posterior C1-2 fixation with a combination of pedicle screws and a laminar screw in C2. We first placed bilateral C1 lateral mass screws and a right-side C2 pedicle screw. However, placement of the left- side C2 pedicle screw was technically difficult due to a narrow isthmus and pedicle. A laminar screw was inserted instead and authors believe that this posterior C1-C2 fixation with a combination of pedicle screws and a laminar screw in C2 can be a useful alternative technique for the treatment of C1-C2 instability in the presence of a unilateral high-riding VA.

Computerized Tomographic Measurements of Morphometric Parameters of the C2 for the Feasibility of Laminar Screw Fixation in Korean Population

  • Kim, Young-June;Rhee, Woo-Tack;Lee, Sang-Bok;You, Seung-Hoon;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권1호
    • /
    • pp.15-18
    • /
    • 2008
  • Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (${\pm}1.0$) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was $43.2^{\circ}$ and mean slope angle was $32.9^{\circ}$. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.

Feasibility of Bilateral Crossing C7 Intralaminar Screws : A Cadaveric Study

  • Baek, Tae-Hyun;Kim, Ilsup;Hong, Jae-Taek;Kim, Daniel H.;Shin, Dongsuk;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.5-10
    • /
    • 2014
  • Objective : When the pedicle screw insertion technique is failed or not applicable, C7 intralaminar screw insertion method has been used as an alternative or salvage fixation method recently. However, profound understanding of anatomy is required for safe application of the bilaterally crossing laminar screw at C7 in clinic. In this cadaveric study, we evaluated the anatomic feasibility of the bilateral crossing intralaminar screw insertion and especially focused on determination of proper screw entry point. Methods : The C7 vertebrae from 18 adult specimens were studied. Morphometric measurements of the mid-laminar height, the minimum laminar thickness, the maximal screw length, and spino-laminar angle were performed and cross-sectioned vertically at the screw entry point (spino-laminar junction). The sectioned surface was equally divided into 3 parts and maximal thickness and surface area of the parts were measured. All measurements were obtained bilaterally. Results : The mean mid-laminar height was 13.7 mm, mean minimal laminar thickness was 6.6 mm, mean maximal screw length was 24.6 mm, and mean spinolaminar angle was $50.8{\pm}4.7^{\circ}$. Based on the measured laminar thickness, the feasibility of 3.5 mm diameter intralaminar screw application was 83.3% (30 sides laminae out of total 36) when assuming a tolerance of 1 mm on each side. Cross-sectional measurement results showed that the mean maximal thickness of upper, middle, and lower thirds was 5.0 mm, 7.5 mm, and 7.3 mm, respectively, and mean surface area for each part was $21.2mm^2$, $46.8mm^2$, and $34.7mm^2$, respectively. Fourteen (38.9%) sides of laminae would be feasible for 3.5 mm intralaminar screw insertion when upper thirds of C7 spino-laminar junction is the screw entry point. In case of middle and lower thirds of C7 spino-laminar junction, 32 (88.9%) and 28 (77.8%) sides of laminae were feasible for 3.5 mm screw insertion, respectively. Conclusion : The vertical cross-sectioned area of middle thirds at C7 spinolaminar junction was the largest area and 3.5 mm screw can be accommodated with 77.8 % of feasibility when lower thirds were the screw entry point. Thus, selection of middle and lower thirds for each side of screw entry point in spino-laminar junction would be the safest way to place bilateral crossing laminar screw within the entire lamina. This anatomic study result will help surgeons to place the screw safely and accurately.

C7 Posterior Fixation Using Intralaminar Screws : Early Clinical and Radiographic Outcome

  • Jang, Sang-Hoon;Hong, Jae-Taek;Kim, Il-Sup;Yeo, In-Sung;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권2호
    • /
    • pp.129-133
    • /
    • 2010
  • Objective : The use of segmental instrumentation technique using pedicle screw has been increasingly popular in recent years owing to its biomechanical stability. Recently, intralaminar screws have been used as a potentially safer alternative to traditional fusion constructs involving fixation of C2 and the cervicothoracic junction including C7. However, to date, there have been few clinical series of C7 laminar screw fixation in the literature. Thus, the purpose of this study is to report our clinical experiences using C7 laminar screw and the early clinical outcome of this rather new fixation technique. Methods : Thirteen patients underwent C7 intralaminar fixation to treat lesions from trauma or degenerative disease. Seventeen intralaminar screws were placed at C7. The patients were assessed both clinically and radiographically with postoperative computed tomographic scans. Results : There was no violation of the screw into the spinal canal during the procedure and no neurological worsening or vascular injury from screw placement. The mean clinical and radiographic follow up was about 19 months, at which time there were no cases of screw pull-out, screw fracture or non-union. Complications included two cases of dorsal breech of intralaminar screw and one case of postoperative infection. Conclusion : Intralaminar screws can be potentially safe alternative technique for C7 fixation. Even though this technique cannot be used in the cases of C7 laminar fracture, large margin of safety and the ease of screw placement create a niche for this technique in the armamentarium of spine surgeons.

Anatomic Consideration of the C1 Laminar Arch for Lateral Mass Screw Fixation via C1 Lateral Lamina : A Landmark between the Lateral and Posterior Lamina of the C1

  • Kim, Jung-Hwan;Kwak, Dai-Soon;Han, Seung-Ho;Cho, Sung-Min;You, Seung-Hoon;Kim, Moon-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권1호
    • /
    • pp.25-29
    • /
    • 2013
  • Objective : To clarify the landmark for deciding the entry point for C1 lateral mass screws via the posterior arch by using 3-dimensional (3D) computed images. Methods : Resnick insisted that the C1 posterior arch could be divided into pure posterior and lateral lamina (C1 pedicle). Authors studied where this transition point (TP) is located between the posterior lamina and the C1 pedicle and how it can be recognized. The 3D computed images of 86 cadaver C1s (M : F=45 : 41) were used in this study. Results : The superior ridge of the C1 posterior arch had 2 types of orientation. One was in the vertical direction in the C1 posterior lamina and the other was in the horizontal direction in the C1 pedicle. The TP was located at the border between the 2 areas, the same site as the posterior end of the groove of the vertebral artery. On posterior-anterior projection, the posterior arch was sharpened abruptly at TP. We were unable to identify the TP in 6.4% of specimens due to complete or partial osseous bridges. A total of 93.8% of the TP were located between the most enlarged point of the spinal canal and the medial wall of the vertebral artery. Conclusion : The anatomic entry zone of C1 lateral laminar screws was clarified and identified based on the TP by using preoperative 3D computed images.