• Title/Summary/Keyword: C1-generic

Search Result 87, Processing Time 0.029 seconds

Digital Signature Schemes with Restriction on Signing Capability (서명 능력을 제한하는 전자 서명 스킴)

  • 황정연;이동훈;임종인
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.12 no.6
    • /
    • pp.81-92
    • /
    • 2002
  • In some practical circumstances, the ability of a signer should be restricted. In group signature schemes, a group member of a group may be allowed to generate signatures up to a certain number of times according to his/her position in the group. In proxy signature schemes, an original signer may want to allow a proxy signer to generate a certain number of signatures on behalf of the original signer. In the paper, we present signature schemes, called c-times signature schemes, that restrict the signing ability of a signer up to c times for pre-defined value c at set-up. The notion of c-times signature schemes are formally defined, and generic transformation from a signature scheme to a c-times signature scheme is suggested. The proposed scheme has a self-enforcement property such that if a signer generates c+1 or more signatures, his/her signature is forged. As a specific example, we present a secure c-times signature scheme $^c$DSA based on the DSA (Digital Signature Algorithm) by using a threshold scheme. Our transformation can be applied to other ElGamal-like signature schemes as well.

Bioequivalence of Sinil Atenolol Tablets to Tenormin Tablets (Atenolol 50 mg) (테놀민 정(아테놀올 50 mg)에 대한 신일아테놀올 정의 생물학적 동등성)

  • Gwak, Hye-Sun;Kang, Sung-Ha;Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.1
    • /
    • pp.51-53
    • /
    • 2003
  • This study was conducted to compare the bioavailability of a generic product of Sinil Atenolol Tablets (Sinil Pharmaceutical Co., Ltd., Korea) with the innovator product, $Tenormin^{\circledR}$ Tablets in 20 healthy Korean volunteers. The volunteers received a single 50 mg dose of each atenolol formulation according to a randomized, two-way crossover design. Plasma samples were obtained over a 24-hour interval, and atenolol concentrations were determined by HPLC with a fluorescence detector. From the plasma atenolol concentration vs time curves, the following parameters were compared: area under the plasma concentration-time curve (AUC), peak plasma concentration $(C_{max})$, time to reach peak plasma concentration $(T_{max})$, and terminal first order elimination half-life $(t_{1/2})$. No statistically significant difference was obtained between the $T_{max}$ values, and the logarithmic transformed AUC and $C_{max}$ values of the two products. The 90% confidence for the ratio of the logarithmically transformed AUC and $C_{max}$ values of Sinil Atenolol Tablets over those of $Tenormin^{\circledR}$ Tablets were calculated to be between 0.99 and 1.07, and 1.04 and 1.16, respectively; both were within the bioequivalence limit of 0.80-1.25. The mean of $T_{max}$ in $Tenormin^{\circledR}$ Tablet group was 3.68 hour, and that in Sinil Atenolol Tablet group was 3.65 hour. The values of $t_{1/2}$ between the two products were found comparable, and the mean $t_{1/2}$ values of $Tenormin^{\circledR}$ Tablets and Sinil Atenolol Tablets were 5.9 and 6.0 hour, respectively. Based on these results, it was concluded that Sinil Atenolol Tablets were comparable to $Tenormin^{\circledR}$ Tablets in both the rate and extent of absorption, indicating that Sinil Atenolol Tablets were bioequivalent to the reference product, $Tenormin^{\circledR}$ Tablets

Bioequivalence Evaluation of Two Atenolol Tablet Preparations in Korean Healthy Male Volunteers

  • Gwak, Hye-Sun;Chun, In-Koo
    • Biomolecules & Therapeutics
    • /
    • v.15 no.3
    • /
    • pp.187-191
    • /
    • 2007
  • This study was conducted to compare the bioavailability of two brands of atenolol (50 mg) tablets, which are a generic product of $Ditent^{\circledR}$ (Daewon Pharmaceutical Co., Ltd., Korea) and an innovator product $Tenormin^{\circledR}$ (Hyundai Pharm. Ind. Co., Ltd., Korea), in 20 healthy Korean male volunteers. The volunteers received a single 50 mg dose of each atenolol formulation according to a randomized, two-way cross-over design. The washout period between treatments was 1 week. Plasma samples were obtained over a 24-hour interval, and atenolol concentrations were determined by HPLC with a fluorescence detector. From the plasma atenolol concentration vs. time curves, the following parameters were compared: area under the plasma concentration-time curve ($AUC_{0-24}$), peak plasma concentration ($C_{max}$), time to reach peak plasma concentration ($T_{max}$), and terminal first order elimination half-life ($t_{1/2}$). No statistically significant difference was obtained between the $T_{max}$ values, and the logarithmic transformed $AUC_{0-24}$ and $C_{max}$ values of the two products. The 90% confidence interval for the ratio of the logarithmically transformed AUC and $C_{max}$ values of $Ditent^{\circledR}$ over those of $Tenormin^{\circledR}$ were calculated to be between 0.85 and 1.04, and 0.89 and 1.07, respectively; both were within the bioequivalence limit of 0.80-1.25. The mean of $T_{max}$ in $Tenormin^{\circledR}$ group was 3.1 hour, and that in Ditent$^{\circledR}$ group was 3.2 hour. The values of $t_{1/2}$ between the two products were found comparable, and the mean values were 5.2 hour in the both products. Based on these results, it was concluded that $Ditent^{\circledR}$ was comparable to $Tenormin^{\circledR}$ in both the rate and extent of absorption, indicating that $Ditent^{\circledR}$ was bioequivalent to the reference product, $Tenormin^{\circledR}$.

ViP: A Practical Approach to Platform-based System Modeling Methodology

  • Um, Jun-Hyung;Hong, Sung-Pack;Kim, Young-Taek;Chung, Eui-Young;Choi, Kyu-Myung;Kong, Jeong-Taek;Eo, Soo-Kwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.2
    • /
    • pp.89-101
    • /
    • 2005
  • Research on highly abstracted system modeling and simulation has received a great deal of attention as of the concept of platform based design is becoming ubiquitous. From a practical design point of view, such modeling and simulation must consider the following: (i) fast simulation speed and cycle accuracy, (ii) early availability for early stage software development, (iii) inter-operability with external tools for software development, and (iv) reusability of the models. Unfortunately, however, all of the previous works only partially addresses the requirements, due to the inherent conflicts among the requirements. The objective of this study is to develop a new system design methodology to effectively address the requirements mentioned above. We propose a new transaction-level system modeling methodology, called ViP (Virtual Platform). We propose a two-step approach in the ViP method. In phase 1, we create a ViP for early stage software development (before RTL freeze). The ViP created in this step provides high speed simulation, lower cycle accuracy with only minor modeling effort.(satisfying (ii)). In phase 2, we refine the ViP to increase the cycle accuracy for system performance analysis and software optimization (satisfying (i)). We also propose a systematic ViP modeling flow and unified interface scheme based on utilities developed for maximizing reusability and productivity (satisfying (ii) and (iv)) and finally, we demonstrate VChannel, a generic scheme to provide a connection between the ViP and the host-resident application software (satisfying (iii)). ViP had been applied to several System-on-a-chip (SoC) designs including mobile applications, enabling engineers to improve performance while reducing the software development time by 30% compared to traditional methods.

Evaluation of the Temperature Dependent Flow Stress Model for Thermoplastic Fiber Metal Laminates (열가소성 섬유금속적층판의 온도를 고려한 유동응력 예측에 대한 연구)

  • Park, E.T.;Lee, B.E.;Kang, D.S.;Kim, J.;Kang, B.S.;Song, W.J.
    • Transactions of Materials Processing
    • /
    • v.24 no.1
    • /
    • pp.52-61
    • /
    • 2015
  • Evaluation of the elevated temperature flow stress for thermoplastic fiber metal laminates(TFMLs) sheet, comprised of two aluminum sheets in the exterior layers and a self-reinforced polypropylene(SRPP) in the interior layer, was conducted. The flow stress as a function of temperature should be evaluated prior to the actual forming of these materials. The flow stress can be obtained experimentally by uniaxial tensile tests or analytically by deriving a flow stress model. However, the flow stress curve of TFMLs cannot be predicted properly by existing flow stress models because the deformation with temperature of these types of materials is different from that of a generic pure metallic material. Therefore, the flow stress model, which includes the effect of the temperature, should be carefully identified. In the current study, the flow stress of TFMLs were first predicted by using existing flow stress models such as Hollomon, Ludwik, and Johnson-Cook models. It is noted that these existing models could not effectively predict the flow stress. Flow stress models such as the modified Hollomon and modified Ludwik model were proposed with respect to temperatures of $23^{\circ}C$, $60^{\circ}C$, $90^{\circ}C$, $120^{\circ}C$. Then the stress-strain curves, which were predicted using the proposed flow stress models, were compared to the stress-strain curves obtained from experiments. It is confirmed that the proposed flow stress models can predict properly the temperature dependent flow stress of TFMLs.

Estimation of High-resolution Sea Wind in Coastal Areas Using Sentinel-1 SAR Images with Artificial Intelligence Technique (Sentinel-1 SAR 영상과 인공지능 기법을 이용한 연안해역의 고해상도 해상풍 산출)

  • Joh, Sung-uk;Ahn, Jihye;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1187-1198
    • /
    • 2021
  • Sea wind isrecently drawing attraction as one of the sources of renewable energy. Thisstudy describes a new method to produce a 10 m resolution sea wind field using Sentinel-1 images and low-resolution NWP (Numerical Weather Prediction) data with artificial intelligence technique. The experiment for the South East coast in Korea, 2015-2020,showed a 40% decreased MAE (Mean Absolute Error) than the generic CMOD (C-band Model) function, and the CC (correlation coefficient) of our method was 0.901 and 0.826, respectively, for the U and V wind components. We created 10m resolution sea wind maps for the study area, which showed a typical trend of wind distribution and a spatially detailed wind pattern as well. The proposed method can be applied to surveying for wind power and information service for coastal disaster prevention and leisure activities.

Free vibrations of anisotropic rectangular plates with holes and attached masses

  • Rossit, C.A.;Ciancio, P.M.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.1
    • /
    • pp.53-67
    • /
    • 2008
  • Anisotropic materials are increasingly required in modern technological applications. Certainly, civil, mechanical and naval engineers frequently deal with the situation of analyzing the dynamical behaviour of structural elements being composed of such materials. For example, panels of anisotropic materials must sometimes support electromechanical engines, and besides, holes are performed in them for operational reasons e.g., conduits, ducts or electrical connections. This study is concerned with the natural frequencies and normal modes of vibration of rectangular anisotropic plates supported by different combinations of the classical boundary conditions: clamped, simply - supported and free, and with additional complexities such holes of free boundaries and attached concentrated masses. A variational approach (the well known Ritz method) is used, where the displacement amplitude is approximated by a set of beam functions in each coordinate direction corresponding to the sides of the rectangular plate. Consequently each coordinate function satisfies the essential boundary conditions at the outer edge of the plate. The influence of the position and magnitude of both hole and mass, on the natural frequencies and modal shapes of vibration are studied for a generic anisotropic material. The classical Ritz method with beam functions as spatial approximation proved to be a suitable procedure to solve a problem of such analytical complexity.

Packet scheduling algorithm for guaranteed bound and firewall property of delay performance (지연의 상한 보장과 안정성을 고려한 패킷 스케쥴링 알고리즘)

  • 정대인
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.5C
    • /
    • pp.435-444
    • /
    • 2002
  • In this paper, a novel packet scheduling algorithm, so-called the CSL algorithm is discussed, whereby the firewall property as well as the deterministic delay bound guarantee are supported in session level. Lots of simulation studies validate those properties of the CSL algorithm. The CSL algorithm is distingushable from the well- known EDD scheme in terms of the firewall property. Regarding the implementation complexity, the CSL algorithm turns out to be of 0(1) besides the sorting overhead. Owing to the maintained generic fair queueing structure in the CSL algorithm, a various fair queueing schemes can be applied with minor modification. For the TCP/IP network which is vulnerable to the misbehaving traffic sources, the firewall property of the CSL algorithm is quite useful for the advanced quality of services.

Pharmacokinetic Study of Aceclofenac and its Metabolites, and Application to Bioequivalence Study (아세클로페낙과 그 대사체의 약물동태 연구 및 생물학적 동등성)

  • Ihm, Chun-Hwa;Hwang, In-Taek;Kim, Eun-Young;Kang, Won-Ku
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.1
    • /
    • pp.52-56
    • /
    • 2006
  • Aceclofenac, a nonsteroidal antiinflammatory agent of a phenylacetic acid type, has been used for rheumatoid arthritis and osteoarthrits. Although the metabolic pathway of aceclofenc is relatively well-known in vitro, pharmacokinetic profiles of its three major or metabolites are still unclear in human. The present study was designed to investigate pharmacokinetic profiles of the metabolites of aceclofenac, and to evaluate the bioequivalence of the generic preparation of aceclofenac 100 mg tablet. Blood samples were serially collected for a period of 12 hours following a single oral administration of 100 mg aceclofenac in 20 healthy human volunteers. A simple protein precipitation with acetonitrile was employed to purify those substances from plasma. Aceclofenac, diclofenac, 4'-hydroxyaceclofenac and 4'-hydroxy-diclofenac in heparinized plasma were simultaneously measured with flufenamic acid, an internal standard, using HPLC coupled to a tandem mass spectrometer. Time courses of 4'-hydroxydiclofenac, diclofenac and aceclofenac plasma concentrations were clearly revealed, and the pharmacokinetic properties were analyzed. The 90% confidence intervals for the ratios of test/reference for log-transformed AUC and $C_{max}$ lie within 0.80-1.25.

  • PDF

A Logic-compatible Embedded DRAM Utilizing Common-body Toggled Capacitive Cross-talk

  • Cheng, Weijie;Das, Hritom;Chung, Yeonbae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.781-792
    • /
    • 2016
  • This paper presents a new approach to enhance the data retention of logic-compatible embedded DRAMs. The memory bit-cell in this work consists of two logic transistors implemented in generic triple-well CMOS process. The key idea is to use the parasitic junction capacitance built between the common cell-body and the data storage node. For each write access, a voltage transition on the cell-body couples up the data storage levels. This technique enhances the data retention and the read performance without using additional cell devices. The technique also provides much strong immunity from the write disturbance in the nature. Measurement results from a 64-kbit eDRAM test chip implemented in a 130 nm logic CMOS technology demonstrate the effectiveness of the proposed circuit technique. The refresh period for 99.9% bit yield measures $600{\mu}s$ at 1.1 V and $85^{\circ}C$, enhancing by % over the conventional design approach.