• Title/Summary/Keyword: C.V.

Search Result 13,350, Processing Time 0.038 seconds

A simulation study on the figure of merit optimization of a 1200V 4H-SiC DMOSFET (1200V급 4H-SiC DMOSFET 성능지수 최적화 설계 시뮬레이션)

  • Choi, Chang-Yong;Kang, Min-Suk;Bang, Wook;Kim, Sang-Chul;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.63-63
    • /
    • 2009
  • In this work, we demonstrate 800V 4H-SiC power DMOSFETs with several structural alterations to observe static DC characteristics, such as a threshold voltage ($V_{TH}$) and a figure of merit ($V_B^2/R_{SP,ON}$). To optimize the static DC characteristics, we consider four design parameters; (a) the doping concentration ($N_{CSL}$) of current spreading layer (CSL) beneath the p-base region, (b) the thickness of p-base ($t_{BASE}$), (c) the doping concentration ($N_J$) and width ($W_J$) of a JFET region, (d) the doping concentration ($N_{EPI}$) and thickness ($t_{EPI}$) of epi-layer. Design parameters are optimized using 2D numerical simulations and the 4H-SiC DMOSFET structure results in high figure of merit ($V_B^2/R_{SP,ON}$>~$340MW/cm^2$) for a power MOSFET in $V_B{\sim}1200V$ range.

  • PDF

Printing of Polyester and Cotton Blends using Diaminoanthraquinone Disperse Dye and Monochlorotriazinyl Reactive Dye Mixtures (디아미노안트라퀴논계 분산염료/모노클로로트리진형 반응염료에 의한 폴리에스테르/면 혼방 직물의 날염)

  • 강숙녀
    • Textile Coloration and Finishing
    • /
    • v.6 no.2
    • /
    • pp.30-39
    • /
    • 1994
  • To study the printing behaviors of Polyester and cotton(P/C) fabrics printed with disperse and reactive dyes, the effects of alkalis on the fixation of reactive dyes and the alkali-stability of disperse dyes in various methods of fixation were examined. The anthraquinone disperse dyes which have diamino derivatives as substituents without hydroxy group, such as C.I. Disperse Violet 1(D.V.1), C.I. Disperse Violet 28(D.V.28) and C.I.Disperse Blue 60(D.B.60) showed good results of fixation without regard to the concentration of NaHCO$_3$. In case of high temperature steaming(HTS) and unsaturated steaming(US)/HTS, D.V. 1 was alkali-stable and effective for P/C printing. A good result was obtained with D.V.1 and C.I.Reactive Orange 13(R.O.13) paste of 4% $K_{2}CO_{3}$. It was found that the unfixed D.V.28 bearing chloro group can hinder the fixation of monochlorotriaxinyl reactive dyes, and D.B.60 made little stain on 100% cotton. In thermosol(Tm), the dye uptake of D.V.1 was not decreased so much, but those of D.V.28 and D.B.60 were greatly decreased.

  • PDF

Electrical Characteristics of $Nb/Al-AlO_x/Nb$ Tunnel Junction fabricated with $I_c$ Values in the Range of $28 A/cm^2~ 940 A/cm^2$ ($28 A/cm^2~ 940 A/cm^2$의 임계전류밀도 범위로 제작된 $Nb/Al-AlO_x/Nb$ 터널접합의 전기적 특성)

  • 홍현권;김규태;박세일;김구현;남두우
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.4-7
    • /
    • 2002
  • Samples of $Nb/Al-AlO_x/Nb$ tunnel junction with the size of $50 ${\mu}{\textrm}{m}$ {\times} 50 ${\mu}{\textrm}{m}$$ were fabricated by using self-aligning and reactive ion etching technique In the high quality samples, the $V_m$ value (the product of the critical current and subgap resistance measured at 2 mV) was 34 mV at the critical current density of $J_c: 500 A/cm^2 and the V_g$ value (the gap voltage) was 2.8 mV. For the higher $J_c$ sample, voltage fluctuation at the gap voltage was observed. The $V_m and J_c$ values for this sample were 8 mV and 900 A/cm$^2$, respectively. Also, the relationship between critical current density $J_c$ and specific normal conductance $G_s$ of the junctions with $J_c$ in the range of 28 A/cm$^2$~940 A/cm$^2$was investigated.

A Study on the Improvement of Combustion Performance in Dump type Ram-combustor Equipped for Flame-holder (Flame-holder를 장착한 Dump Type Ram-combustor의 연소성능 향상에 관한 연구)

  • 이대웅;윤현진;문수연;손창현;이충원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.43-46
    • /
    • 2001
  • In the experiment of dump type Ram-combustor equipped for flame-holder which is designed for development of combustion performance, temperature of center of exit decreases in the case of short length($L_c$=300mm) of combustor while does not decrease in the case of $L_c$=500mm and flame still remains under the center of combustor. With V-gutter, temperature distribution of exit becomes uniform. In the case of $L_c$=300mm, combustion efficiency of combustor with V-gutter increases a few but the influence of V-gutter is small.

  • PDF

Structural and C-V characteristics of SrTiO$_3$ /PbTiO$_3$ thin film deposited on Si (Si 기판위에 증착한 SrTiO$_3$ /PbTiG$_3$ 고용체 박막의 구조적 특성 및 C-V 특성)

  • 이현숙;이광배;김윤정;박장우
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.71-74
    • /
    • 2000
  • Pt/Pb$TiO_3$/$SrTiO_3$/p-Si films were prepared by metallo-organic solution deposition(M0SD) method and investigated its structure and ferroelectric properties. Crystallinity of specimen as a funtions of post annealing temperature and the thickness of $SrTiO_3$(STO) buffer layer was studied using XRD and AFM. Based on C-V and P-E curve, $PbTiO_3$(PTO) capacitors showed good ferroelectric hysteresis arising from the polarization switching properties. When the thickness of ST0 buffer layer between PTO and Si substrate was 260 nrn and the post annealing temperature was $650^{\circ}C$, it was showed that production of the pyrochlore phase due to interdiffusion of Si into FTO was prevented. The dielectric constant of FTO thin films calculated from a maximum Cma in the accumulation region was 180 and the dielectric loss was 0.30 at 100 kHz frequency. The memory window in the C-V curve is 1.6V at a gate voltage of 5V.

  • PDF

Molecular Cloning, Bioinformatics Analysis and Expression Profiling of a Gene Encoding Vacuolar-type $H^+-ATP$ Synthetase (V-ATPase) c Subunit from Bombyx mori

  • Lu, Peng;Chen, Keping;Yao, Qin;Yang, Hua-Jun
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.15 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • As the genome of B.mori is available in GenBank and the EST database of B.mori is expanding, identification of novel genes of B.mori is conceivable by data-mining techniques. We used the in silico cloning method to get the vacuolar-type $H^+-ATP$ synthetase (V-ATPase) c subunit (16 kDa proteolipid subunit) gene of B.mori and analysed with bioinformatics tools. The result was confirmed by RT-PCR and sequencing. The V-ATPase c subunit cDNA contains a 468 bp ORF. The ORF encoded a 155-residue protein that showed extensive homology with V-ATPase c subunits from other 15 species and contained four membrane-spanning helices. Tissue expression pattern analysis revealed that V-ATPase c expressed strongly in Malpighian tubules, not in fat body. This gene has been registered in GenBank under the accession number EU082222.

Characteristics of Ni metallization on ICP-CVD SiG thin film and Ni/SiC Schottky diode (ICP-CVD로 성장된 SiC박막의 Ni 금속 접합과 Ni/SiC Schottky diode의 특성 분석)

  • Gil, Tae-Hyun;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.938-940
    • /
    • 1999
  • We have fabricated SiC Schottky diode for high temperature applications. SiC thin film for drift region has been deposited by ICP-CVD. In order to establish metallization conditions, we have extracted the device parameters of the Schottky diode from the forward I-V characteristics and the C-V characteristics as a function of temperature. The ideality factor was varied from 2.07 to 1.15 and the barrier height was also varied from 1.26eV to 1.92eV with increase of temperature. The reverse blocking voltage was 183 V.

  • PDF

Study on the Sublimatographic Characters of Sulfur (황의 Sublimatographic Characters에 관한 연구)

  • Sohn, Jin-Un;Kim, Joo-Bong
    • Elastomers and Composites
    • /
    • v.7 no.1
    • /
    • pp.53-58
    • /
    • 1972
  • Sublimatographic study on the method of test for sulfur in the petroleum and rubber products was as following results: (1) The relation between the heating temperature$(t_h)$ and the vacuum condensing point(V.C.P.) of sulfur at different degree of vacuum appeared as Fig.4. The results were in good agreement with those expected from the $t_h-V.C.P$ curves of sublimatographic separation of sulfur. (2) The relation between the degree of vacuum and the V.C.P. at different heating temperature of sulfur appeared as follows; $$tv.c.p.=\alpha+{\beta}logP_{va}$$ (3) The V.C.P of sulfur could be physical property comparing with melting point and boiling point. (4) The relation between the V.C.P. and the quantity of sublimation of sulfur becomes quantitative as Fig.7.

  • PDF

The Evaluation of Non-Coplanar Volumetric Modulated Arc Therapy for Brain stereotactic radiosurgery (뇌 정위적 방사선수술 시 Non-Coplanar Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Doo Sang;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.9-16
    • /
    • 2018
  • Purpose : Brain Stereotactic Radiosurgery can treat non-invasive diseases with high rates of complications due to surgical operations. However, brain stereotactic radiosurgery may be accompanied by radiation induced side effects such as fractionation radiation therapy because it uses radiation. The effects of Coplanar Volumetric Modulated Arc Therapy(C-VMAT) and Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT) on surrounding normal tissues were analyzed in order to reduce the side effects caused fractionation radiation therapy such as head and neck. But, brain stereotactic radiosurgery these contents were not analyzed. In this study, we evaluated the usefulness of NC-VMAT by comparing and analyzing C-VMAT and NC-VMAT in patients who underwent brain stereotactic radiosurgery. Methods and materials : With C-VMAT and NC-VMAT, 13 treatment plans for brain stereotactic radiosurgery were established. The Planning Target Volume ranged from a minimum of 0.78 cc to a maximum of 12.26 cc, Prescription doses were prescribed between 15 and 24 Gy. Treatment machine was TrueBeam STx (Varian Medical Systems, USA). The energy used in the treatment plan was 6 MV Flattening Filter Free (6FFF) X-ray. The C-VMAT treatment plan used a half 2 arc or full 2 arc treatment plan, and the NC-VMAT treatment plan used 3 to 7 Arc 40 to 190 degrees. The angle of the couch was planned to be 3-7 angles. Results : The mean value of the maximum dose was $105.1{\pm}1.37%$ in C-VMAT and $105.8{\pm}1.71%$ in NC-VMAT. Conformity index of C-VMAT was $1.08{\pm}0.08$ and homogeneity index was $1.03{\pm}0.01$. Conformity index of NC-VMAT was $1.17{\pm}0.1$ and homogeneity index was $1.04{\pm}0.01$. $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$ of the brain were $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$ and $4.03{\pm}3.43cc$ in the C-VMAT and $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$. Conclusions : The maximum dose, conformity index, and homogeneity index showed no significant difference between C-VMAT and NC-VMAT. $V_2$ to $V_{18}$ of the brain showed a difference of at least 0.5 % to 48 %. $V_{19}$ to $V_{24}$ of the brain showed a difference of at least 0.4 % to 4.8 %. When we compare the mean value of $V_{12}$ that Radione-crosis begins to generate, NC-VMAT has about 12.2 % less amount than C-VMAT. These results suggest that if NC-VMAT is used, the volume of $V_2$ to $V_{18}$ can be reduced, which can reduce Radionecrosis.

  • PDF

Effects of Aconiti Tuber on the Change of Interleukin-6 and $TNF-{\alpha}$ Level induced by LPS I.C.V. Injection in Mice (부자(附子)가 Lipopolysaccharide의 뇌실 주입으로 유발된 생쥐의 혈중 IL-6와 $TNF-{\alpha}$ 변화에 미치는 영향)

  • Koh Dong-Kyun;Yun Jeong-Moon;Lee Tae-Hee
    • Herbal Formula Science
    • /
    • v.12 no.1
    • /
    • pp.195-208
    • /
    • 2004
  • Objective: This study was conducted to investigate the effects of Aconiti Tuber on the plasma IL-6 and $TNF-{\alpha}$ level in mice stimulated by intracerebroventricular(I.C.V.) Injection of Lipopolysaccharide(LPS). Method: 6 mice were assigned to each of the normal group, the control group, and the experimental group. In the normal group only saline was administered intragastrically, and in the control group LPS was injected intracerebro-ventricularly 1 hr after intragastric administration of saline. In the experimental groups (Aconiti Tuber 0.5g/kg, Aconiti Tuber 1.0g/kg, Aconiti Tuber 3.0g/kg) each sample was administered intragastrically to mice 1 hr prior to the stimulation by LPS I.C.V. Injection. To measure the plasma IL-6 and $TNF-{\alpha}$ level of mice, their blood samples were collected from retro-orbital plexus, immediately centrifuged at $4^{\circ}C$, and plasma was removed and stored frozen at $-83^{\circ}C$ for later determination of plasma IL-6 and $TNF-{\alpha}$. Result : 1. LPS I.C.V. Injection increased plasma IL-6 level significantly in a dose-dependent manner compared with normal group(P<0.01). The plasma IL-6 concentration reached a significant maximal level about 1 hr after LPS I.C.V. Injection(P<0.001). LPS I.C.V. Injection increased plasma $TNF-{\alpha}$ level significantly in a dose-dependent manner(P<0.05). The plasma $TNF-{\alpha}$ concentration reached a significant maximal level about 1 hr after LPS I.C.V. Injection(P<0.001). 2. Sample A group to which Aconiti Tuber(0.5g/kg) was administered intragastrically 1 hr prior to the stimulation by LPS I.C.V. Injection showed insignificant lower plasma IL-6 level in 1 hr than control group(P<0.0635), and sample B group (Aconiti Tuber 1.0g/kg) showed significant lower plasma IL-6 level in 1 hr than control group(P〈0.05), and sample C group (Aconiti Tuber 3.0g/kg) showed significant lower IL-6 plasma level in 1 hr than control group(P<0.01). 3. sample A group to which Aconiti Tuber(0.5g/kg) was administered intragastrically 1 hr prior to the stimulation by LPS I.C.V. Injection showed insignificant lower plasma $TNF-{\alpha}$ level in 1 hr than control group(P>0.05), and Both sample B(1.0g/kg) and sample C(3.0g/kg) groups showed significant lower $TNF-{\alpha}$ plasma level in 1 hr than control group(P<0.01). These data revealed that Aconiti Tuber might have the anti inflammatory effect by reducing the plasma IL-6 and $TNF-{\alpha}$ level in a dose dependent manner in mice LPS I.C.V. Injection.

  • PDF