• Title/Summary/Keyword: C.G.TECH

Search Result 209, Processing Time 0.022 seconds

Growth of Sapphire Crystals by Verneuil Method (Verneuil법에 의한 Sapphire단결정 성장)

  • Joo, K.;Bae, S.Y.;Choi, J.K.;Orr, K.K.;Son, S.K.;Beun, Y.J.;Chun, H.T.
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.5
    • /
    • pp.495-501
    • /
    • 1988
  • Verneuil method uses oxyhydrogen flame for its heat source. This method was used to grow corundum monocrystals. Parametersof this method are feeding rate, gas pressure, lowering rate and growth axis. These parameters were examined. Crystals's qualities and shapes are affected by these parameters. Crystals having good qualities and shape were grown under the conditions that feeding rate, 0.2∼0.5g/min, lowering rate, 10∼20mm/hr ; gas pressure, 3∼4psi ; growth axis was shifted 60 degrees from c axis.

  • PDF

Multi-aging Test Technology for Estimating Long Time Performance of Polymer Insulators (폴리머 절연물 장기성능 평가를 위한 복합열화 시험기술)

  • Cho, H.G.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2332-2334
    • /
    • 1999
  • This paper presents the results of multi-stress chamber experiments done to examine the tracking and erosion performance of polymer insulator. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs including the nature of interfaces in insulation design. Therefore, multi-stress testing is believed to a suitable test for evaluating the aging performance of polymer insulator designs. We have investigated IEC 61109 Annex C for estimating long time performance of polymer insulator.

  • PDF

Development of Built-on PC UPS Using MICOM and GUI (마이컴과 GUI를 이용한 컴퓨터 내장형 무정전 전원장치의 개발)

  • Kim, D.W.;Woo, J.I.;Nam, G.R.;Gung, J.Y.;Shin, D.R.;Kim, H.S.;Park, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2259-2261
    • /
    • 2003
  • 본 연구에서는 전원선로의 정전시나 입력 전원에 이상 상태가 발생했을 때 정상적인 전원을 컴퓨터에 공급하는 Power Supply 내장용 무정전 전원장치(Uninterruptible Power System : UPS)의 개발하였다. 본 연구에서 개발한 내장형 무정전 전원장치는 마이컴(PIC16C74A)을 이용하여 컴퓨터 Power Supply 내부에 장착하였으며, 사용자가 편리하도록 하기 위해서 내장형 무정전 전원장치의 그래픽 사용자 인터페이스를 구현하였다.

  • PDF

A fault location algorithm for distribution feeder systems (배전선로 고장점 표정 알고리즘)

  • Lee, D.S.;Jin, B.G.;Lee, S.J.;Kang, S.H.;Choi, M.S.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.251-253
    • /
    • 2001
  • This paper presents a fault location algorithm for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the symmetrical components and admittance load model.

  • PDF

An Exper System for Dignosis of Fault Location on Electric Power Distribution System (배전 계통에서의 고장점 진단 전문가 시스템 개발)

  • Jin, B.G.;Lee, D.S.;Lee, S.J.;Kang, S.H.;Choi, M.S.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.319-321
    • /
    • 2001
  • When the fault occurred at distribution system, the restoration was late. There are 2 reasons The one is the error of fault location the other is multiple possible candidates of fault location. This paper presents two of new techniques for diagnosing fault regions. The proposed diagnosis scheme is capable of accurately identifying the location of fault upon its occurrence. based on the integration of information available from protective devices and measured load current change at the substation. In this paper expert system for real fault region is presented using these facts. Testing of the developed system using EMTP Simulation Model has demonstrated.

  • PDF

A fault location algorithm using current distribution factors for D/S (전류분배계수를 이용한 배전계통 고장점 표정 알고리즘)

  • Lee, D.S.;Jin, B.G.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.275-277
    • /
    • 2001
  • This paper presents a fault location algorithm using current distribution factors for distribution feeder systems. When a fault occurs in distribution system, an accurate fault distance is important for fast fault restoration. The proposed algorithm achieves a high accuracy using negative sequence circuit with various fault conditions.

  • PDF

A fault location algorithm using iterative method at unbalance conditions for distribution feeder systems (불평형시 반복추정기법을 이용한 배전계통 고장점 표정 알고리즘)

  • Lee, D.S.;Jin, B.G.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.121-123
    • /
    • 2001
  • This paper presents a fault location algorithm using iterative method at unbalance condition for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the phase components and admittance load model.

  • PDF

An Expert System Using Current Waveform for Dignosis of Fault Location on Electric Power Distribution System (전류 파형을 이용한 배전계통에서의 고장점 진단 전문가 시스템)

  • Jin, B.G.;Lee, D.S.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.278-281
    • /
    • 2001
  • Identifying the fault location has to deal with multiple possible candidates. It presents a new technique to diagnosis a fault region. The proposed diagnosis scheme identifies accurately the location based on the protective device operations and load current change at the substation. An Expert system is presented using these facts.

  • PDF

Performance Analysis of Switched Reluctance Motor with considering pole shoe (Pole shoe의 영향을 고려한 스위치드 릴럭턴스 전동기의 특성 해석)

  • Jang, S.M.;Park, P.I.;Lee, S.H.;Sung, S.Y.;Lee, J.H.;Choi, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.672-674
    • /
    • 2000
  • The paper presents design procedure and characteristics of Switched Reluctance Motor(SRM). SRM is capable of application to various field because of its constructional advantages. In design procedures, pole shoe will be considered. First step, overall design will be accomplished using PC-SRD. Then, inductance and torque characteristics is inspected with motor geometries by FEA.

  • PDF

Optimization of Algerian Thymus fontanesii Boiss. & Reut Essential Oil Extraction by Electromagnetic Induction Heating

  • Ali, Lamia Sid;Brada, Moussa;Fauconnier, Marie-Laure;Kenne, Tierry
    • Natural Product Sciences
    • /
    • v.24 no.1
    • /
    • pp.71-78
    • /
    • 2018
  • The present study deals with the determination of optimal values of operating parameters such as the temperature of heating, the mass of the plant material and the volume of water leading to the best yield of electromagnetic induction (EMI) heating extraction of Algerian Thymus fontanesii essential oil. After an appropriate choice of the three critical variables, eight experiments leaded to a mathematical model as a first-degree polynomial presenting the response function (yield) in the relation to the operating parameters. From the retained model, we were able to calculate the average response, the different effects and their interactions. The maximum of essential oil recovery percentage relative to the initial mass of plant material was 1.69%, and was obtained at ($140^{\circ}C$, 250 g and 4.5 L). The chemical composition of the Algerian T. fontanesii essential oil under the obtained optimal conditions ($140^{\circ}C$, 250 g and 4.5 L), determined by GC/MS and GC/FID, reveled of the presence of major components such as: carvacrol ($70.6{\pm}0.1%$), followed by p-cymene ($8.2{\pm}0.2%$).