• Title/Summary/Keyword: C.C.M system

Search Result 6,087, Processing Time 0.052 seconds

Development of a Ginseng Surface Washing System (인삼 표면세척 시스템 개발)

  • Lee, Hyun-Seok;Jeong, Jin-Woong;Kim, Byeong-Sam;Kwon, Ki-Hyun
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.541-548
    • /
    • 2009
  • We developed a surface washing system for ginseng. The washing system was developed using different treatments and conditions and characterized in terms of product hardness, weight loss, and change in temperature and color. Optimal results were obtained using a surface washing system involving a washing conveyor speed of 1.0 L/min, a water pressure of $35\;kg/cm^2$, a washing nozzle angle of $40^{\circ}$, a washing height of 5 cm, a 1-sec reciprocating washing nozzle cycle, a dehydration wind velocity of 30 m/sec, and an internal drying temperature of $30-33^{\circ}C$. A surface washing system using a washing conveyor speed of0.8 L/min, a water pressure of $40\;kg/cm^2$, a washing nozzle angle of $40^{\circ}$, a washing height of 3 cm, a 1-sec reciprocating washing nozzle cycle, a dehydration wind velocity of 30 m/sec, and an internal drying temperature of $30-33^{\circ}C$ resulted in ginseng that was stained yellow.

PREGNANCY RATE AND SURVIVAL IN CULTURE OF IN VITRO FERTILIZED BOVINE EMBRYOS FROZEN IN VARIOUS CRYYOPROTECTANTS AND THAWED USING A ONE-STEP SYSTEM

  • Suzuki, T.;Takagi, M.;Yamamoto, M.;Boediono, A.;Saha, S.;Sakakibara, H.;Oe, M.
    • Proceedings of the Korean Society of Embryo Transfer Conference
    • /
    • 1997.05a
    • /
    • pp.27-34
    • /
    • 1997
  • Bovine oocytes surrounded with compact cumulus cells were cultured for 20 to 22 hours($38^{\circ}C$, 5% $CO_2$) in modified TCM-199 medium supplemented with 5% superovulated cow serum(SCS) and inseminated by in vitro capacitated spermatozoa. Day 7 to 8 embryos were equilibrated for 10 minutes in 1.3M methyl cellosolve(MC) <1.1M diethylene glycol(DEG), 1.8M ethylene glycol(EG), 1.6M propylene glycol(PG) and 1.1 M 1,3-butylene glycol(BG) solutions. They were then loaded into 0.25ml straws, placed into an alcohol bath freezer at $0^{\circ}C$, cooled from $0^{\circ}C$ to $-6^{\circ}C$ at $-1^{\circ}C$/minute, seeded, held for 10 minutes, and stored in liquid nitrogen. After thawing in $30^{\circ}C$ water, the embryos wee rehydrated in TCM-199 medium and then cultured for 48 hours in TCM-199 plus 5% SCS. Embryos were considered viable if they progressed to later developmental stages with a good morphology. Some of the embryos frozen in each cryoprotectant were thawed and transferred non-surgically without removing the cryoprotectant. Hatched embryos survived freezing and one-step dilution as follows : EG(50.0%), MC(53.6%), DEG(56.9%), PG(58.0%) and BG(11.5%). The survival rate of embryos cooled at -0.3^{\circ}C$ vs. $-0.5^{\circ}C$/minute was not significantly different(P<0.05), however, blastocysts hatched most often (P<0.01) in vitro when cooled at a rate of $0.3^{\circ}C$/minute(64.6%), 31/48) than at $-0.5^{\circ}C$/minute(22.6%, 12/53). Pregnancy rates resulting from embryos frozen in the different cryoprotectants were as follows : MC(48%, 10/21); DEG(30%, 3/10); EG(74%, 20/27); and PG(40%, 4/10). These results indicate that MC, DEG, EG and PG have utility as cryoprotectants for the freezing and thawing of IVF Bovine embryos.

  • PDF

Development of High Efficiency Dehumidifiers in low temperature (저온에서 고효율 제습기 개발)

  • Kim, Jong-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.206-211
    • /
    • 2016
  • Various applications require dry air at low temperature, such automation equipment, semiconductor manufacturing, chemical production lines, and coating processes for the shipbuilding industry. Four evaporators for low temperature (below $0^{\circ}C$) were installed for a dehumidification system. Moist air is cooled sequentially over three evaporators. The first evaporator has an evaporation temperature of $13^{\circ}C$, that of the second evaporator is $5^{\circ}C$, and that of the third evaporator is maintained at $-1.3^{\circ}C$. In the fourth evaporator implantation thereby the moisture contained in the moisture air. A pressure regulator (CPCE 12) is used at this point and is defrosted when the vapor pressure is below a set value. The non-implantation moisture of the air is a heating system that uses the waste heat of a condenser with high temperature. It develops the cooling type's dehumidifier, which is important equipment that prevents the destruction of protein and measures the temperature and humidity at each interval by changing the front air velocity from 1.0 m/s to 4.0 m/s. The cooling capacity was also calculated. The greatest cooling capacity was 1.77 kcal/h for a front air velocity of 2.0 m/s

Analysis of Temperature Changes in Greenhouses with Recirculated Water Curtain System (순환식 수막하우스의 수온에 따른 플라스틱 온실 내 온도변화 분석)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Pyo, Hee-Young;Jeong, Jae-Woan;Kim, Yong-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.93-99
    • /
    • 2015
  • The purpose of this study was to determine the appropriate temperature for water curtain in greenhouses equipped with recirculated water curtain system. The study analyzed the changes in air temperature in non-heated greenhouses for strawberry cultivation based on outdoor temperature, water curtain temperature and night time. Three greenhouse units were used for this study: The first unit was assigned as a control (no water curtain system), two other greenhouses were equipped with recirculated water curtain system with water curtain temperatures of $10^{\circ}C$ and $15^{\circ}C$, respectively. Analysis showed that the indoor temperatures were directly correlated with the outdoor temperature in all experimental greenhouses. Heat insulating effect of $15^{\circ}C$ water curtain was increased by $1.3^{\circ}C$ compared to that in $10^{\circ}C$ water curtain system. The $15^{\circ}C$ water curtain treatment showed the highest average temperature and less temperature variation in comparison with control and $10^{\circ}C$ water curtain treatment. To maintain indoor temperature at $5^{\circ}C$, water curtain temperature of $10^{\circ}C$ was suitable when outdoor minimum and average temperatures were -1.3 and $1.5^{\circ}C$, and water curtain temperature of $15^{\circ}C$ was suitable when outdoor minimum and average temperatures were -4.7 and $-0.2^{\circ}C$, respectively. The highest temperature in greenhouses according to measurements in different periods of night time was observed after sunset (18:30-20:30), and the lowest temperature before sunrise (05:00-07:00). Water curtain maintained a target indoor temperature by acting as a layer of heat transfer insulator which decreased heat loss from greenhouses. Therefore, water temperature in recirculating water curtain systems should be determined by considering outdoor temperatures, changes in temperature at different periods of night time, and cultivated crop.

Development of the Preventive Diagnostic System for Substation (변전소 예방진단시스템 데이터 취득장치 개발)

  • Shim, J.T.;Sim, S.M.;Kweon, D.J.;Choi, I.H.;Jung, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.428-430
    • /
    • 2001
  • This paper describes development of a preventive diagnostic system for the substation equipments. Data acquisition system, communication control unit and computer systems have been developed in the recent 2 years. The developed system is operating in 345kV U-Ryung substation for performance and environment tests.

  • PDF

Performance Analysis of M-ayy PPM Ultra-wideband Multiple Access Systems Using Gaussian Monopulse (가우시안 모노펄스를 이용하는 M-ary PPM 초광대역 다중접속시스템의 성능해석)

  • Kwak, Jae-Min;Lee, Sung-Chul;Cho, Sarm-Goo;Cho, Sung-Joon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.229-233
    • /
    • 2003
  • In this paper we theoretically analyze the probability of error for M-ary pulse position modulation (PPM) ultra-wideband (UWB) multiple access system using Gaussian monopulse. The optimum detection of UWB signals using M-ary orthogonal PPM in additive white Gaussian noise (AWGN) and multiple access interference (MAI) is considered, then receiver signal to noise power ratio (SNR) and upper bound fur the bit error rate (BER) are derived. Numerical results considering some practical parameters are presented.

  • PDF

COMPLEX SUBMANIFOLDS IN REAL HYPERSURFACES

  • Han, Chong-Kyu;Tomassini, Giuseppe
    • Journal of the Korean Mathematical Society
    • /
    • v.47 no.5
    • /
    • pp.1001-1015
    • /
    • 2010
  • Let M be a $C^{\infty}$ real hypersurface in $\mathbb{C}^{n+1}$, $n\;{\geq}\;1$, locally given as the zero locus of a $C^{\infty}$ real valued function r that is defined on a neighborhood of the reference point $P\;{\in}\;M$. For each k = 1,..., n we present a necessary and sufficient condition for there to exist a complex manifold of dimension k through P that is contained in M, assuming the Levi form has rank n - k at P. The problem is to find an integral manifold of the real 1-form $i{\partial}r$ on M whose tangent bundle is invariant under the complex structure tensor J. We present generalized versions of the Frobenius theorem and make use of them to prove the existence of complex submanifolds.

A Study on the Design and Implementation of SDLA for C-Band Application (C-Band용 SDLA의 설계 및 구현에 관한 연구)

  • 임경택;윤기방;조홍구
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.11a
    • /
    • pp.711-727
    • /
    • 2000
  • In this paper, the design of the successive detection logarithmic amplifier(SDLA) is reviewed for radar and EW system, and implemented in hybrid MIC. The SDLA operates over the 5 to 7㎓ frequency range. the unit has a dynamic range of -80㏈m to 0㏈m, a logging accuracy of ±1.4㏈, a legging slope 19.2㎷/㏈, and a gain flatness of ± 1.2㏈. Input VSWR of less than 2, noise figure of 2㏈, video impedance of 900Ω and output voltage range of 0 to 1.53V DC have been obtained over 80㏈ of dynamic range.

  • PDF

Reactive Dyeing in Immiscible Two-phase System of Water/Organic Solvent (II) - The Dyeing of Silk with C. I. Reactive Blue 203 - (물/유기용매 불혼합 이성분계에서의 반응염색(II) - C. I. Reactive Blue 203을 이용한 견섬유의 염색 -)

  • 김태경;김미경;임용진;조광호
    • Textile Coloration and Finishing
    • /
    • v.13 no.2
    • /
    • pp.128-134
    • /
    • 2001
  • Following the prior studs regarding that 1.0g of cotton fabric round be dyed uniformly with a reactive dye in the solvent mixture of $2m\ell$ of water and $23m\ell$ of dichloromethane, silk fabric was dyed with C. I. Reactive Blue 203 in the water/dichloromethane two-phase immiscible solvent media. In order to minimize dye loss due to its hydrolysis, the reactive dyeing was carried out in dichloromethane containing a small amount of water. With only $3m\ell$ of water in $22m\ell$ of dichloromethane, 1.0g of silk fabric could be dyed perfectly. The uptake ratio was increased greatly, compared wish that of normal reactive dyeing in a water medium. It would seem that the one of hydrophobic solvents, dichloromethane, can assist the Even dyeing as it disperses a small amount of dye-dissolved phase and conveys this water phase to the fabric entirely and uniformly.

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF