• Title/Summary/Keyword: C.C.M system

Search Result 6,087, Processing Time 0.047 seconds

Unified design approach for single- and 3-phase input air conditioning systems using SiC devices

  • Kim, Simon;Balasubramaniasarma, Swaminathan;Ma, Kwokwai;Chung, Daewoong
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.205-208
    • /
    • 2020
  • This paper examines the approach, enabled by using SiC power devices, to unify the inverter design for central air conditioning (CAC) system for both single- and 3-phase input, and reduce the PFC inductor size to be PCB-mountable. By using SiC-instead of Si-diode in PFC stage, it is possible to increase the switching frequency from 16kHz to 60kHz to reduce the required PFC inductance from 0.93mH to 0.25mH, thus enable PCB-mounting of inductor. With the next step of using 1200V SiC MOSFET instead of Si-IGBT, the DC link voltage can be boosted from 311Vdc to 550Vdc in PFC stage, allowing the inverter and compressor used in 3-phase input CAC be used for single-phase input as well. Furthermore, using SiC MOSFET in inverter stage can further reduce total loss system total loss to 200.8 W. Simulation and experimental results are presented in the paper.

  • PDF

Design and Implementation of Digital Contract System on the Mobile Environment : M-XContract (모바일 환경에서 전자 계약 시스템의 설계 및 구현 : M-XContract)

  • Hwang, Ki-Tae;Kim, Nam-Yun
    • The KIPS Transactions:PartC
    • /
    • v.10C no.5
    • /
    • pp.575-584
    • /
    • 2003
  • Due to hardware resource limit and system incompatibility of the mobile device, and low bandwidth of wireless communication, there are a few difficulties in introducing the digital contract system based on wired communication to M-Commerce. To get over the difficulties, this paper defines a digital contract based upon XML and then addresses the design and implementation of M-XContract, a digital contract system for the mobile environment. M-XContract system has been constructed with the digital contract server, M-ESign module which contracts with the customer on the PDA and transfers the contract digitally signed to the server, M-EDecoder module which shows the contract to the customer from the server, and X-Auth which is a contract authoring tool. To evaluate the run-time performance of the M-XContract, we measured the digital signature generation time and transfer time to the server. The evaluation results show that the M-Xcontract is an efficient model for the mobile contract system.

Improvement of Radiosynthesis Yield of [11C]acetate ([11C]아세트산의 방사화학적 수율 증가를 위한 연구)

  • Park, Jun Young;Son, Jeongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.74-78
    • /
    • 2018
  • Purpose $[^{11}C]$acetate has been proved useful in detecting the myocardial oxygen metabolism and various malignancies including prostate cancer, hepatocellular carcinoma, renal cell carcinoma and brain tumors. The purpose of study was to improve the radiosynthesis yield of $[^{11}C]$acetate on a automated radiosynthesis module. Materials and Methods $[^{11}C]$acetate was prepared by carboxylation of grignard reagent, methylmagnesium chloride, with $[^{11}C]$$CO_2$ gas, followed by hydrolysis with 1 mM acetic acid and purification using solid phase extraction cartridges. The effect of the reaction temperature ($0^{\circ}C$, $10^{\circ}C$, $-55^{\circ}C$) and cyclotron beam time (10 min, 15 min, 20 min, 25 min) on the radiosynthesis yield were investigated in the $[^{11}C]$acetate labeling reaction. Results The maximum radiosynthesis yield was obtained at $-10^{\circ}C$ of reaction temperature. The radioactivities of $[^{11}C]$acetate acquired at $-10^{\circ}C$ reaction temperature was 2.4 times higher than those of $[^{11}C]$acetate acquired at $-55^{\circ}C$. Radiosynthesis yield of $[^{11}C]$acetate increased with increasing cyclotron beam time. Conclusion This study shows that radiosynthesis yield of $[^{11}C]$acetate highly dependent on reaction temperature. The best radiosynthesis yield was obtained in reaction of grignard reagent with $[^{11}C]$$CO_2$ at $-10^{\circ}C$. This radiolabeling conditions will be ideal for routine clinical application.

Microbiological Changes of Marinated Broiler Drumsticks Treated with the Lactoperoxidase System and with or without Thermal Treatment

  • Tan, Fa-Jui;Ockerman, Herbert W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.1
    • /
    • pp.109-112
    • /
    • 2006
  • The objective of this study was to evaluate the combined effects of lactoperoxidase system (LPS), thermal treatment and storage time on total microflora and psychrotrophs counts of the marinated broiler drumsticks. A marinade that contained acetic acid (1%) and salt (3%) with pH adjusted to 4 was developed as a standardized marinade. Drumsticks were marinated with various LPS levels, combined with thermal treatment (4 or $58^{\circ}C$ for 2 min), and then stored at $4^{\circ}C$ for 18 h. The microbial counts of the samples were measured after 0, 2, 4 and 7 days of storage for drumsticks held at $4^{\circ}C$. The results indicate that adding LPS at the level of 1 unit ($1{\mu}g/ml$ LP, 5.9 mM KSCN, and 2.5 mM $H_2O_2$) significantly (p<0.05) decreased the total microflora and psychrotrophs counts of the marinated broiler drumsticks. In addition, samples treated with a thermal treatment ($58^{\circ}C$ for 2 min) had significantly (p<0.05) lower microbial counts when compared with the control.

A Case Study on the Seasonal Temperature Variations in Depth of a Vertically-installed Geothermal Heat Exchange Pipe (계절별 운전조건에 따른 수직형 지열교환기의 깊이별 지중온도 변화에 대한 사례 연구)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.45-50
    • /
    • 2009
  • To estimate the operating performances of the geothermal heat exchange pipe(GHEX), GHEXs of 400RT geothermal system were measured and analyzed through a year. The followings are the results. The temperature of 2 GHEXs installed 4m apart was fluctuated very similarly. When the geothermal system is nor operating or is operating as heating mode, the temperature of G.L.-170m was always higher than G.L.-70m's. But it reversed when the geothermal system is operating as cooling mode. And through a year, it has been observed that the temperature of G.L.-170m is increased approximately $1.5^{\circ}C$. With previously mentioned results, the heat transfer capacity of G.L.-70m's geological stratum is estimated as higher than that of the G.L.-170m.

Development New Inverter System for Linkage Control of Punching M/C (Punching M/C의 연동 제어를 위한 새로운 Inverter System개발)

  • 조현섭
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.212-214
    • /
    • 2002
  • 본 논문에서는 기존 공정 Line중 TG Feed Back방식을 이용한 Control System은 매우 고가(高價)인 외산 TG임에도 불구하고 구동 Motor의 발열로 인하여 전압 검출부 Cabon Brush의 잦은 마모로 인한 오동작으로 작업의 문제점이 표출되어 생산성이 저하되고 품질 불만 및 불량품 발생으로 생산성에 큰 손실을 입고 있다. 이러한 문제점을 해결하기 위하여 본 연구에서는 새로운 Inverter Control System을 개발하였다. 여기에 따른 파급 효과는 제품의 생산성 향상과 소모성 부품의 수입 대처 및 부분적 제어시스템의 국산화 효과를 확보 할 수 있다.

Geothermal Effects on the Underground Water Conveyance Pipe System from Han River (한강수계 광역상수도 원수관의 지열 영향 조사)

  • Cho, Yong;Park, Jin-Hoon;Park, Tae Jin;Kim, Youngjoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.171.2-171.2
    • /
    • 2010
  • Geothermal effects on the underground water conveyance pipe system have been investigated through the multiregional water supply system from Paldang water intake station. To make an investigation of raw water thermal energy, temperature sensors are installed the surface of the pipes of metropolitan area water supply system. In 2009 winter and early spring seasons, the monthly averaged temperatures at Paldang 2 intake stations are $1.94^{\circ}C$ in February, $4.96^{\circ}C$ in March, and $10.56^{\circ}C$ in April. After the transfer in 26.0 km distance of tunnel and buried pipe, the raw water temperatures are raised to $3.13^{\circ}C$, $6.04^{\circ}C$, and $11.39^{\circ}C$ respectively. As the temperature difference between the raw water and the air reduces, the temperature increasement is reduced by $1.19^{\circ}C$ in Feb., $1.08^{\circ}C$ in Mar., and $0.83^{\circ}C$ in Apr. Since the flowrate is over 1,150,000 $m^3$/day, it is estimated that the water exchanges a huge amount of heat over 1.0 Tcal a day with the ground.

  • PDF

A Study on the Cycling Effects and the Hydrogen Absorption-Desorption Characteristics Of Metal Hydrides (DiNi5-H2 system) (금속수소화물(DiNi5-H2 system)의 수소 흡수-방출 특성과 반복 효과에 관한 연구)

  • Kim, Youn-Sang;Zhoh, Choon-Koo
    • Applied Chemistry for Engineering
    • /
    • v.1 no.1
    • /
    • pp.30-34
    • /
    • 1990
  • This paper summarizes fundamental research on a metal hydrides for the development of new energy. We made a study of the characteristics of the hydrogen absorption-desorption of $DiNi_5$ alloys. As a result, we found that the maximum amount of the hydrogen absorption of $DiNi_5$ alloys (the maximum in the absorption equilibrium pressure section) was H/M=1.04 at $30^{\circ}C$. The hysteresis was the smallest at $30^{\circ}C$. The capability of the hydrogen absorption-desorption was excellent. The number of cycles of the hydrogen absorption-desorption was about 9000 times at $30^{\circ}C$. We found also that the rate of the hydrogen desorption was the largest at $40^{\circ}C$.

  • PDF

Extraction of Alkali Metal Cation with Crown Ethers and HDEHP (Crown Ether와 HDEHP에 의한 알칼리금속이온의 추출)

  • Ihn Chong Lee;Si Joong Kim;Chul Lee
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.359-368
    • /
    • 1986
  • Solvent extraction equilibria of alkali metal cation with crown ether (DC18C6, DC24C8) and HDEHP have been studied. The extraction equilibrium constants increase in the order of, in the DC18C6 system, $Na^+, and in the DC24C8 system, $Rb^+. The species extracted to organic phase are $M_1(crown ether)_1\;(HDEHP)_1$. The magnitude of extraction equilibrium constant is determined by the distribution ratio of crown ether between organic and aqueous phase, and stability constant of crown ether-alkali metal complex.

  • PDF

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF