• Title/Summary/Keyword: C-scanner

Search Result 176, Processing Time 0.032 seconds

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

  • Kim, Min-Kyu;Son, KeunBaDa;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.361-368
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS. Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS. The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION. The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.

MRI의 현황과 전망

  • 전희국
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.125-130
    • /
    • 1988
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of $0.1^{\circ}C$ under the spatial resolution of lmrad, the image matrix size of $256 {\times} 240, $ and tile imaging time of 4 seconds.

  • PDF

A Study on the Influence of Stacking Sequences using CFRP Laminate Plates by Falling Weight Impact (탄소섬유복합평판에 낙추충격을 가할 때 적층구성에 미치는 영향에 관한 연구)

  • 임광희;박노식;양인영
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.106-109
    • /
    • 2000
  • Impact tester was build up to evaluate the characterization of CFRP laminate plates under the low velocity impact. The tests were conducted on several laminates of different ply orientation A system was budded for the impact strength of CFRP laminates in consideration of stress wave propagation theory using drop-weight impact tester as one of impact test. Results indicate that absorbed energy of quasi-isotropic specimen having four interfaces is higher than that of orthotropic laminates with two interfaces. Also the damage area was measured with ultrasonic C-scanner on some samples. In the specimens the relationship was linear between damaged area and absorbed energy to some degree. Absorbed energy in the specimen that ply number, interface number and fiber stacking sequences is same but having hybrid is higher than that of orthotropic laminates without hybrid.

  • PDF

High Resolution Elements Analysis in N-E Pacific Sediments using XRF Core Scanner (XRF 코어스캐너를 이용한 북동태평양 퇴적물 내 원소의 고해상분석)

  • Um, In-Kwon;Kim, Ji-Hoon;Nam, Seung-Il;Choi, Hun-Soo;Park, Ok-Boon
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.129-138
    • /
    • 2009
  • The XRF core scanner was used, to analyze high resolution chemical elements in deep sea sediment cores from Clarion-Clipperton fracture zone of the northeastern Pacific. Comparison of data estimated by the XRF core scanner with ICP-AES showed relatively weak correlation coefficients between elements (especially Ba, Pb, Sr, Zr) except for Mn contents ($r^2$ > 0.89). However down-core variations of most elements seemed to be well matched each other and furthermore, XRF core scanner data reflected changes of sedimentary facies characterized by sediment colors. Mn/Al ratio dramatically changed at boundaries of facies in BC08-02-05 and BC08-02-13 but progressive changes occured in BC08-02-02, BC08-02-09 and BC08-02-10 where the sediments have been affected by bioturbations. The difference of Mn/Al ratio in each facies (Facies I, Facies II, Facies III) has been caused by redox condition of depositional environment. Vertical change of Mn/Al ratio were divided into two types probably affected by activities of benthic organisms in the study area.

Estimating Dense Forest Canopy Structure Using Airborne Laser Scanner Data

  • Park J. H.;Jang K. C.;Ma J. L.;Lee K. S.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.638-641
    • /
    • 2004
  • Returned laser pulse has certain relationship with vegetation canopy structure (canopy closure, height, LAI, biomass). This study attempts to analyze the characteristics of airborne laser scanner data over very dense forest canopy. Discrete pulse laser scanner data were obtained on April 25, 2004 along with digital aerial color imagery. Using forest stand maps, 14 sample stands of 7 species groups were selected and the elevations from the first and last laser return were compared. From the preliminary analysis, we found that the difference between the first and last return was higher with deciduous forest stand than in coniferous stand. Although difference between the first and the last laser returns often corresponds to tree height, it would not be the case for the forest site having very dense canopy structure.

  • PDF

Analysis of the Vibration Characteristic for the Mine Detectable Test Platform (지뢰탐지 실험플랫폼의 진동 특성 해석)

  • Chang, YuShin;Kwak, NoJin;Han, SeungHoon;Ji, UnHo;Ji, ChangJin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.12
    • /
    • pp.927-934
    • /
    • 2014
  • In this paper, analysis of the vibration characteristic for the mine detectable test platform is described. The test platform system is the multi-sensor mine detectable vehicle. This multi-sensor mine detectable unit is more efficient detection performance than other conventional methods. The test platform system has five subsystems, the UWB(ultra wide band) sensor scanner, the MD(metal detector) sensor scanner, the ND(neutron detector) sensor scanner, and the detectable vehicle. We perform the vibration tests for the test platform and analyze the vibration characteristic, such as the max displacement, the max deformation and the max Von-Misses stress.

Measurement of Particle Deposition Velocity toward a Horizontal Semiconductor Wafer Using a Wafer Surface Scanner (Wafer Surface Scanner를 이용한 반도체 웨이퍼상의 입자 침착속도의 측정)

  • Bae, G.N.;Park, S.O.;Lee, C.S.;Myong, H.K.;Shin, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.130-140
    • /
    • 1993
  • Average particle deposition velocity toward a horizontal semiconductor wafer in vertical airflow is measured by a wafer surface scanner(PMS SAS-3600). Use of wafer surface scanner requires very short exposure time normally ranging from 10 to 30 minutes, and hence makes repetition of experiment much easier. Polystyrene latex (PSL) spheres of diameter between 0.2 and $1.0{\mu}m$ are used. The present range of particle sizes is very important in controlling particle deposition on a wafer surface in industrial applications. For the present experiment, convection, diffusion, and sedimentation comprise important agents for deposition mechanisms. To investigate confidence interval of experimental data, mean and standard deviation of average deposition velocities are obtained from more than ten data set for each PSL sphere size. It is found that the distribution of mean of average deposition velocities from the measurement agrees well with the predictions of Liu and Ahn(1987) and Emi et al.(1989).

  • PDF

Study of Servo Controller for Improving Position Accuracy of 3D Terrestrial Laser Scanner (지상용 3차원 레이저 스캐너의 측정 위치 정확도 향상을 위한 서보 제어기의 연구)

  • Yu, Jong-Wook;Jeong, Joong-Yeon;Kim, Tae-Hyung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.187-194
    • /
    • 2009
  • This study is to improve position accuracy by selecting proper a servo motor and applying FOC(Field Oriented Control) on developing a 3D terrestrial laser scanner. A 3D terrestrial laser scanner under developing has range of scanning of azimuth 360$^\circ$and elevation 270$^\circ$. It is implemented by precise controlling of a azimuth motor and a elevation motor. In the consequence of study, we have known that position accuracy of the motor can be able to be improved with constant torque of the motor by using FOC(Field Oriented Control). The control technic of the motor is possible to apply a 3D terrestrial laser scanner as well as a robotic total station.