방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구 (Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy)

  • 나수경
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

고차표면 경사자계코일을 이용한 새로운 공간 선택 방법 (A New Spatial Localization Technique Using High-Order Surface Gradient Coils (SGC))

  • 이종권;양윤정;정성택;이윤;조장희;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.43-46
    • /
    • 1994
  • A new spatial localization technique using high-order surface gradient coil (SGC) is proposed. Although the Spatial Selection with High-Order gradient (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient produced by cylindrical-shape coils has not been clinically useful for clinical systems due to the large minimum selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useful 1-4 cm in diameter by applying stronger radial gradient with much less gradient driving power. A 40 cm-by-40 cm $r^{2}$ SGC has been designed and constructed, and phantom and volunteer studies have been performed. Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

Vacuum Cushion 사용시 표면선량과 투과율 평가 (Surface Dose and Transmission Factor for Vacuum Cushion)

  • 김미화;이병용;전미선
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.74-78
    • /
    • 2002
  • 환자 치료시 환자의 위치고정과 매번 치료에서 환자 치료 자세의 재현을 위해 사용하는 고정물(immobilizer)중 Vacuum cushion을 사용시 Vacuum cushion으로 인해 예상되는 표면선량 또는, 투과량의 변화들을 측정하여 Vacuum cushion의 특성을 평가하였다. 광자선 에너지 4 MV (Varian 4/100, 미국), 6MV, 15 MV (Varian CL2100C/D, 미국)에 대해서 조사면의 크기를 5$\times$5, 10$\times$10, 20$\times$20, 30$\times$30, 40$\times$40 $\textrm{cm}^2$로, Vacuum cushion의 두께는 12, 32, 48 mm, 그리고 스티로폼이 없이 진공 봉지만 있는 경우로 변화해가며 Vacuum cushion에 대해 팬톰 표면에서 d$_{max}$까지의 선량을 측정하였다. 그 결과 vacuum cushion 두께에 대한 투과율은 0.9953-1.0043의 분포로 거의 차이가 없었다. 그리고 vacuum cushion의 두께가 두꺼워질수록, 환자가 받는 표면 선량은 증가하였다. 에너지, 조사면 크기에 대해 Vacuum cushion의 두께에 따라 표면 선량의 변화가 있었으나 6 MV와 15 MV에 대해 알려진 aquaplast의 데이타와 가장 두꺼운(48mm) vacuum cushion의 표면선량 증가율을 비교시 aquaplast보다 대략 16, 12% 낮아 임상에 적용하는데 무리가 있을 만큼 심각한 문제가 아니었다.

  • PDF

광중성자 발생으로 인한 전립샘암 환자의 유전적 위험과 발암의 확률에 관한 연구 (A Study on the Genetic Risk and Carcinogenesis Probability of Prostate Cancer Patients Due to Photoneutron Generation)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.473-479
    • /
    • 2023
  • 본 연구에서는 고 에너지를 이용한 전립샘암의 방사선 치료 시 발생되는 광중성자의 선량을 광자극발광선량계를 사용하여 측정하였다. 이에 따른 복부에 발생되는 유효선량에 의한 유전적 위험확률을 연구하고자 하였다. 15 MV 에너지 발생이 가능한 의료용 선형가속기 True Beam STx(Varian Medical Systems, USA)와 방사선 치료 계획 시스템(Eclipse, Varian Medical System, USA)을 사용하였다. 선형가속기 Couch 위에 인체팬텀을 설치하고, 광중성자 선량의 측정은 Albedo Neutron Optical Stimulation Luminescence Neutron Detector(Landauer Inc., IL, USA)를 사용하였다. VMAT과 3C-CRT 의 복부에서 광중성자 선량값은 VMAT이 3D-CRT에 비하여 2배 이상 높은 52.8 mSv 였다. 전립샘암의 방사선 치료 시, 광중성자 선량으로 인한 복부에 발생되는 유효선량에 의한 유전적 위험확률은 VMAT는 1,000명 당 3.2명, 3D-CRT는 1.4명이 발생률임을 산출하였다. 전립샘암의 방사선 치료 시 발생할 수 있는 큰 부작용이 있는 복부를 연구함으로써 전립샘암 환자들의 삶의 질과 확률적 영향을 연구하는데에 의미 있는 연구로 활용되어지길 기대한다.

초음파 치료의 효율성 향상을 위한 초음파 온열 시뮬레이터 개발 (The Development of Ultrasonic Hyperthermia Simulator to Improve the Efficiency of Ultrasonic Therapy)

  • 유우진;노시철;정동환;박재현;최민주;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권5호
    • /
    • pp.418-427
    • /
    • 2009
  • As many people are westernizing their life style and food consumption habits, a number of patients who have malignant tumors which grow very rapidly and hazardously destroy the human body are increasing. Ultrasonic hyperthermia is not only one of the tumor treatment methods which employs the non-radioactive ultrasonic waves to increase the temperature at the tumor region up to $40\sim45^{\circ}C$ to destroy and suppress tumor cells but also has been proved by many studies. Due to the rapid development of High Intensity Focused Ultrasound(HIFU), the ultrasound hyperthemia extensively boosts its applications in clinical field. For those reasons, Computed simulation factor should be needed before inspection to patients. To prove efficiency of ultrasonic hyperthermia, precise acoustic field measurement considering tissue characteristics and a heating experiment with tissue mimicking material phantom were conducted for effectiveness of simulation program. Finally, in this study, the computer simulation program verified the anticipated temperature effects induced by ultrasound hyperthermia. In the near future, it is hoped that this simulation program could be utilized to improve the efficiency of ultrasound hyperthermia.

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.19-24
    • /
    • 1996
  • 이 논문의 목적은 Target field approach방법을 사용하여 2차원적인 공간선택을 할 수 있는 고차 평면 경사 자계코일(High-Order SGC: High-Order Surface Gradient Coil)을 설계하는 것이다. 지금까지 쓰이던 원통형의 고차경사자제코일을 이용한 2차원적 원형 선택방법은 한 개의 RF Pulse로 2차원적인 공간 선택을 할 수 있는 장점이 있었으나 선택되어지는 체적의 지름이 6 ~ 8cm로 너무 크다는 단점이 있었다. 이 논문에서는 이와 같은 단점을 극복하기 위해 영상을 얻고자하는 부분에 코일을 좀 더 가까이 붙일 수 있어서 적은 전력으로 선택되어지는 체적의 지름을 1 ~ 4cm까지 줄일 수 있는 표면 고차자계코일을 Target field approach방법을 이용하여 설계하였으며 Phantom과 인체영상을 통해 제작된 코일의 성능을 확인해 보았다. 이전의 Field component 방법을 이용하여 설계한 코일에 의해서 선택되어지는 체적은 타원에 가까운 모양이 되었으나, Target field approach 방법을 이용하여 설계한 코일에 의해서 선택되어지는 체적은 이상적인 원에 가까운 모양이 되었다.

  • PDF

3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가 (Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT))

  • 김진수;이재성;이병일;이동수;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.318-324
    • /
    • 2004
  • 목적: Philips GEMINI PET/CT 스캐너는 GSO 섬광결정을 사용해 제작된 전신용 PET/CT 스캐너이다. 이 연구에서는 NEMA에서 새롭게 제안한 NEMA NU2-2001에 따라 GEMINI PET/CT 스캐너의 공간분해능, 민감도, 산란분획, NECR 등을 평가하고 그 결과를 BGO, LSO등의 섬광결정의 특성과 비교하였다. 대상 및 방법: GEMINI는 Philips ALLEGRO PET과 MX8000 D multi-slice CT 스캐너를 결합한 PET/CT 스캐너로서 검출기는 GSO 섬광결정 ($4{\times}6{\times}20mm^3$)을 사용하였고 축방향 시야는 18 cm이다. 공간분해능. 민감도, 산란분획, NECR 등을 평가하기 위하여 PET 데이터를 획득하였다(동시계수창: 8 ns, 에너지창: $409{\sim}664$ keV). 공간분해능 측정을 위하여 축횡단면의 중심에서 1 cm, 10 cm 떨어진 지점의 각 3지점((a) x=0, y=1, (b)x=10, y=0, (c)x=0, y=10)에서 영상을 획득한 다음 여과후역투사방법(램프필터 사용)과 3D RAMLA를 이용하여 영상재구성을 하고 FWHM을 구하였다. 민감도 측정을 위하여 선선원(F-18)을 축횡단면의 중심과 중심에서 10 cm 벗어난 지점에서 5개의 알루미늄관을 차례로 씌워 매질감쇠에 따라 달라지는 참계수를 구하고 이 값을 회귀분석하여 감쇠매질이 없는 이상적인 상황에서의 민감도를 측정하였다(랜덤계수가 참계수의 1%이내). 산란분획과 NECR을 측정하기 위하여 F-18 선선원(1110 MBq)을 산란팬텀에 주입하여 7반감기동안 계수를 획득하였다. SSRB을 사용하여 3D 데이터를 재구성한 다음 랜덤계수율이 참계수율이 1% 미만인 영역에서 산란분획을 구하고 각 횡단면의 값을 평균하여 전체 산란분획을 얻었다. 이 값을 기초로 각 프레임, 각 횡단면에 대한 랜덤계수율, 산란계수율, NECR을 구하였다. 결과: 스캐너의 중심에서 1 cm 벗어난 지점에서 횡축방향, 축방향 공간분해능은 (1) 5.3, 6.5 mm (FBP), (2) 5.1, 5.9 mm (3D RAMLA)이었다. 횡단면의 중심에서 10 cm 벗어난 지점에서 횡축반경방향, 횡축접선방향, 축방향 공간분해능은 (1) 5.7, 5.7, 7.0 mm (FBP), (2) 5.4, 5.4, 6.4 mm (3D RAMLA)이었다. 감쇠매질이 없는 이상적인 상황에서의 민감도는 횡단면의 중심에서 3,620 counts/sec/MBq, 횡단면의 중심에서 10 cm 벗어난 지점에서 4,324 counts/sec/MBq이었다. 산란분획은 40.6%, 최대 참계수율과 최대 NECR은 각각 88.9 kcps @ 12.9 kBq/mL, 34.3 kcps @ 8.84 kBq/mL이었다. 결론: 이 실험에서 NEMA NU2-2001을 이용해 GSO 섬광결정을 사용해 제작된 PET/CT에 대한 성능 평가를 실시하였다. 이는 BGO, LSO 섬광결정을 사용해 제작된 PET 스캐너의 특성과 비교할 수 있는 자료를 제공하며 PET 영상 획득 시 객관적 평가와 분석에 유용하였다.

전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교 (Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus)

  • 김병수;박주영;박병석;송용민;박병수;송기원
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.163-170
    • /
    • 2014
  • 목 적 : 표재성 종양 치료를 위하여 선택한 전자선은 bolus와 동시에 사용할 경우 표면선량에 급격한 변화를 보이게 되며 이는 치료결과의 중요한 변수로 작용할 수 있다. 이에 본 논문에서는 전자선 치료에서 bolus가 적용될 경우 표면선량을 좌우할 수 있는 4 가지 변수에 따른 치료계획시스템(Treatment Planning System, TPS)의 표면선량 계산 값과 실제 측정값을 비교 분석하였다. 대상 및 방법 : 치료계획시스템(Pinnacle 9.2, philips, USA)과 실제 측정값을 비교하기 위하여 실제 치료 시 주로 발생되는 4가지 변수(A: bolus 두께 - 3, 5, 10 mm, B: 조사야 크기 - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: 에너지 - 6, 9, 12 MeV, D: 겐트리 각도 - 0, $15^{\circ}$)를 설정하였다. 16 cm 두께의 solid water phantom을 이용하여 bolus(Action Products, USA) 없이 전산화단층촬영(lightspeed ultra 16, General Electric, USA)을 시행하였고 치료 계획은 TPS 상에서 각각 3, 5, 10 mm bolus를 생성하여 A, B, C, D를 조합한 총 54개의 beam으로 계획하였다. 이때 SSD 100 cm, 300 MU를 조사하였고 TPS와 실제 측정값을 비교 분석하기 위해 EBT3 film(International Specialty Products, NJ, USA)을 이용해 iso-center에 위치시켜 2회 반복 측정하였다. 측정된 film은 디지털 평판 스캐너(Expression 10000XL, EPSON, USA)와 선량 농도 분석시스템(Complete Version 6.1, RIT, USA)을 사용하여 각각의 평균값과 표준편차 값으로 분석하였다. 결 과 : bolus 두께에 따른 값은 3, 5, 10 mm에서 실제 측정된 값이 TPS의 계산 값보다 각각 101.41%, 99.58%, 101.28%, 표준편차는 각각 0.0219, 0.0115, 0.0190 으로 나타났다. 조사야 크기에 따른 실제 측정값은 $6{\time}6$, $10{\time}10$, $15{\time}15cm2$ 각각 계산 값에 비해 99.63%, 101.40%, 101.24%, 표준편차는 0.0138, 0.0176, 0.0220 으로 나타났다. 에너지에 따른 값은 상대적으로 6, 9, 12 MeV 각각 99.72%, 100.60%, 101.96%, 표준편차는 0.0200, 0.0160, 0.0164로 나타났다. 빔 각도에 따른 실제 측정값은 계산된 값에 비하여 0, $15^{\circ}$에서 각각 100.45%, 101.07%, 표준편차는 0.0199, 0.0190 으로써 $15^{\circ}$에서 $0^{\circ}$보다 0.62% 높게 측정되었다. 결 론 : 본 논문에서 사용한 변수에 따른 계산 값과 측정값을 분석한 결과 5 mm bolus, $6{\time}6cm2$ 조사야, 저 에너지 전자선, $0^{\circ}$ 겐트리 각도에서 TPS로 계산한 값이 측정값에 더 가까웠지만 다른 변수를 적용한 비교에서도 최대 2% 오차범위 내에 포함되는 결과를 보였다. 전자선과 bolus를 동시에 사용하는 경우 본 논문에서 선택된 변수의 범위를 벗어난다면 각각의 변수에 따라 실제 측정값이 TPS와 달라질 수 있기 때문에 정확한 표면선량에 대한 QA를 반드시 실시해야 한다.

3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램 (A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling)

  • ;;;조민형;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.107-119
    • /
    • 2014
  • 목적: 실제 촬영 결과와 전자기 모의실험 결과를 시각적으로 비교함으로써 위상배열코일을 이루는 모든 코일 요소의 감도를 효과적으로 검증할 수 있는 소프트웨어를 개발하였다. 대상과 방법: 위상배열코일검증기(PACE)라 불리는 프로그램을 MATLAB과 C언어를 이용해 구현하였다. 위상배열 코일검증기는 코일 소자의 3차원 형상 모델 구축, FDTD 모의실험 결과의 수용, 보통의 직각좌표계 및 코일면에 기준하는 직각좌표계 상에서 각기 코일 소자 감도를 도시하는 기능을 가지고 있다. 위상배열코일의 3차원 형상 모델을 구축하기 위해 바늘침 모양의 3차원 전자기 위치추적기를 사용하였다. 3차원 형상 모델을 만든 뒤, 이 형상 모델 데이터를 FDTD 모의실험 장치에 보낼 수 있게 하였다. 결과: 3차원 전자기 위치추적기를 이용해 실제 실험에 사용된 위상배열코일과 FDTD 모의실험에 사용된 위상배열코일 모델을 정확하게 일치시킴으로써, 각기 코일 소자의 공간적 감도를 평가할 때 모의실험 결과와 촬영실험 결과 사이 정확한 비교가 가능하게 되었다. 모의실험과 실제 촬영실험에는 36 채널의 헬멧형 위상배열코일을 사용하였다. MRI 촬영 대상체로는 FDTD 모의실험의 모델과 같은 크기와 형상을 가진 원통형 팬텀을 사용하였다. 개발한 프로그램에서는 위상배열코일의 성능을 편리하게 평가하기 위해 관심 코일 소자를 쉽게 선택할 수 있게 하였다. 결론: 개발한 위상배열코일 성능 검증 프로그램은 위상배열코일의 개발 및 정기적인 유지보수에 사용될 수 있을 것으로 기대한다.

인체 표면 통신을 위한 TM31 고차 모드 반원-링 인체 부착형 마이크로스트립 패치 안테나 설계 (Design of a TM31 Higher Order Mode Half Circular-Ring Microstrip Patch Antenna for On-Body Communications)

  • 탁진필;전재성;김선우;최재훈
    • 한국전자파학회논문지
    • /
    • 제25권5호
    • /
    • pp.491-503
    • /
    • 2014
  • 본 논문에서는 모노폴과 같은 방사특성을 갖고 인체 표면 간 통신을 위한 $TM_{31}$ 고차 모드 반원-링 마이크로스트립 패치 안테나를 제안하였다. 제안된 안테나는 단락 핀을 이용하여 $TM_{31}$ 고차 공진 모드를 형성하였고, 평면형임에도 불구하고 모노폴과 같은 방사특성을 갖는다. 패치안테나의 좁은 대역폭을 확장하기 위해 $TM_{31}$ 모드 C-형 반링 패치를 반원 패치에 인접시켰으며, 소형화를 위해 half mode를 사용하였다. 인체 착용환경을 고려하여 마이크로스트립 라인을 이용하여 급전하였다. 제안된 안테나는 ISM(Industrial, Scientific, and Medical) 2.45 GHz 대역(2.4~2.485 GHz)에서 $0.25{\lambda}_0{\times}0.46{\lambda}_0{\times}0.025{\lambda}_0$의 크기를 갖고, 2.38~2.49 GHz에서 4.24 %의 10-dB 반사손실 대역폭을 갖는다. 인체의 영향을 고려하기 위해 2/3 근육-등가 반고체형 모의인체를 제작하고, 이를 이용하여 안테나에 미치는 인체의 영향을 분석, 검증하였다. 또한, 실제 인체 상황에서 제안된 안테나를 통해 인체 표면 간 링크의 통신 성능 분석을 위한 실험을 수행하였다.