• Title/Summary/Keyword: C ratio)

Search Result 14,737, Processing Time 0.04 seconds

Combustion Characteristics of Model Gas Turbine Combustor -Radical Luminous Intensity and Local Equivalence Ratio Measurement- (모형 가스터빈 연소기의 연소특성 -라디칼 자발광강도와 국소당량비계측에 대하여-)

  • 최병륜;김태한
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.1064-1071
    • /
    • 1994
  • There are three active radicals which become to the scale of flame diagnostics at the flame front. They are OH, CH and $C_2$ radical. For this, optical measurement system which could monitor simultaneously the luminous waves of three radicals, was constructed. These were analyzed statistically into the cross correlation, coherence and phase. Through such an statistical treatment, combustion characteristics was investigated at the primary zone of gas turbine combustor. The local equivalence ratio was predicted with the ratio of luminuous intensity between CH and $C_2$ radical. This result was matched up to the equivalence ratio calculated from gas composition within 5% error. In general, equivalence ratio was said to be 1.0 at flame front, but it could be increased up to about 1.2 depending on the degree of swirl intensity in case of changing properly the air amount of primary zone.

Correlation between Longitudinal Wave Velocity and Strength of Early-aged Concrete (초기 재령 콘크리트의 종파 속도와 강도의 상관관계)

  • 이휘근;이광명;김동수
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.67-74
    • /
    • 2000
  • The usage of nondestructive testing on early-aged concrete leads to enhacned safty and allows effective scheduling of construction, thus making it possible to maximize the time and cost efficiencies. In this study, a reliable nondestructive strength evaluation method for early-aged concrete using the longitudinal wave velocity is proposed. Compression tests were performed to examine factors influencing the velocity-strength relationship of concrete, such as water-cement (w/c) ratio, fine aggregate ratio, curing temperature, and curing condition. The test results show that a change in the w/c ratio and curing temperature has minor effect on the velocity-strength relationship/ However, curing condition significantly influences the velocity-strength relationship of early-aged concrete. Moreover, the longitudinal wave velocity increases with decreasing fine aggregate ratio. It is concluded from this study that the strength evaluation of early-age concrete can be achieved by a nonlinear equation which considers the effects of curing condition and fine aggregate ratio.

Antimony Surfactant Effect on p-GaN growth by Metal Organic Chemical Vapor Deposition (MOCVD)

  • Lee, Yeong-Gon;Sadasivam, Karthikeyan Giri;Baek, Gwang-Seon;Kim, Bong-Jun;Kim, Hak-Jun;Lee, Jun-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.56.2-56.2
    • /
    • 2010
  • An improvement in the optical and structural properties of p-GaN was obtained by using antimony (Sb) as a surfactant during p-GaN growth. Two different growth temperatures of p-GaN such as $1030^{\circ}C$ and $900^{\circ}C$ were considered. Keeping the growth conditions for p-GaN constant, Sb was introduced during p-GaN growth while varying the [Sb]/([Ga]+[Mg]) flow ratio. [Sb]/([Ga]+[Mg]) flow ratio will be denoted as SGM ratio for convenience. SGM ratio of 0, 0.015 and 0.03% were considered for high temperature p-GaN growth. SGM ratio of 0, 0.005, 0.01 and 0.02% were considered for low temperature p-GaN growth. The analysis results suggest that using the optimum SGM ratio during p-GaN growth greatly improves the optical and structural properties of the p-GaN.

  • PDF

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment (전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술)

  • 정재갑;박영태;권성원
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

Effect of Forging Condition on the Microstructure and Mechanical Properties in Centrifugal Casted Heat Resistant Steel (원심주조된 내열강의 미세조직 및 기계적성질에 미치는 단조 조건의 영향)

  • Kang, C.Y.;Lee, S.M.;Jo, D.H.;Park, Y.T.;Lee, D.H.;Kim, Y.C.
    • Journal of Power System Engineering
    • /
    • v.13 no.3
    • /
    • pp.47-52
    • /
    • 2009
  • The effect of forging start temperature, forging ratio on the microstructure and mechanical properties of B7B4 steel ware investigated. Microstructure of centrifugal casted B7B4 steel consisted of martensite and ferrite phase. The volume fraction of ferrite increased with increase of forging start temperature and decreased with increase of forging ratio. Tensile strength and hardness decreased with higher of forging start temperature, while impact value and elongation increased with higher of forging start temperature. With increase of forging ratio, tensile strength rapidly increased up to the forging ratio of 30%, and then slowly increased, but elongation was decreased. Hardness and impact value rapidly increased with increase of forging ratio.

  • PDF

Development of The Standard Current Transformer with Wide Ratio Error and Its Application (광범위 비오차 표준 전류변성기의 개발 및 그 응용)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kim, Mun-Seog;Kim, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.302-307
    • /
    • 2006
  • Standard current transformer(CT) with the nominal ratio errors in the range of - 10 % to + 10 % has been developed. Linearity of the CT ratio error measuring system (CT comparator) has been tested by using wide ratio error standard current transformer(WRE CT). The developed WRE CT can be used to evaluate the linearity of the CT comparator by comparing both the theoretical values and experimental values of the WRE CT. The developed method has been successfully applied for calibration and correction in the CT comparator belonging to industry.

A Detection Scheme for GNSS Repeat-back Jamming Signal Using Correlation Ratio Test Metric of C-PRN Signal (통합의사잡음 신호의 상관비 실험을 이용한 GNSS 재방송재밍 신호 검출기법)

  • Yoo, Seungsoo;Yeom, Dong-Jin;Jee, Gyu-In;Kim, Sun Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.665-670
    • /
    • 2016
  • This paper proposes a repeat-back jamming signal detection scheme using a correlation ratio test metric of a combined pseudo-random noise signal for global navigation satellite systems. The correlation ratio test metric allows for the monitoring of possible distortions in the signal correlation. The proposed scheme is a modified version of the correlation ratio test metric to detect a repeat-back jamming signal in a multipath environment. Through a Monte-Carlo simulation, it is confirmed that the proposed scheme detects almost the whole case, which is received a repeat-back jamming signal under the 6 dB jamming to signal power ratio.

Analysis of Electronic Endoscopic Image of Intramucosal Gastric Carinoma by Using Homoglobin Index (혈색소지수를 이용한 점막내 위암의 전자내시경 영상 분석)

  • Kim Gwang-Ha;Lim Eun-Kyung;Kim Gwang-Baek
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2005.11a
    • /
    • pp.535-541
    • /
    • 2005
  • It has been suggested that the endoscopic color of intramucosal gastric carcinoma is correlated with mucosal vascularity within the carcinomatous tissue. The development of electronic endoscopy has made it possible to quantitatively measure the mucosal hemoglobin volume, using a hemoglobin index. The aim of this study was to make a software program to calculate the hemoglobin index (IHb) and then investigate whether the mucosal IHb determined from the electronic endoscopic data is a useful marker for evaluating the color of intramucosal gastric carcinoma, in particular with regard to its value for discriminating between the histologic type. The mean values of IHb for the carcinoma (IHb-C) and the mean values of IHb for the surrounding non-cancerous mucosa ( IHb-N) were calculated in 75 intestinal-type and 34 diffuse-type gastric carcinomas. Then, we analyzed the ratio of the IHb-C to IHb-N. The mean IHb-C/IHb-N ratio in the intestinal-type carcinoma group was higher than that in the diffuse-type carcinoma group ($1.28{\pm}0.19$ vs. $0.81{\pm}0.18$, respectively, p<0.001). When the cut-off point of the C/N ratio was set at 1.00, the accuracy rate, the sensitivity, the specificity, and the positive and negative predictive values of a C/N ratio below 1.00 for the differential diagnosis of diffuse-type carcinoma from intestinal-type carcinoma were $94.5\%$, $94.1\%$, $94.7\%$, $88.9\%$ and $97.3\%$, respectively. IHb is useful for quantitative measurement of the endoscopic color in intramucosal gastric carcinoma and the IHb-C/IHb-N ratio would be helpful in distinguishing diffuse-type carcinoma from intestinal -type carcinoma.

  • PDF

Study on Optimum Conditions for the Composting of Industrial Wastewater Sludge (공단 폐수 슬러지의 퇴비화 최적조건)

  • Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Su
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • To study the optimum conditions of composting with industrial wastewater sludge, the variations of temperature and $CO_2$ generation amount during the composting periods were investigated. The conditions were that industrial wastewater added to bulking agents such as sawdust and rice hull was used, and differently treated with microorganism seeding or not, initial C/N ratios, air flow rate and initial moisture contents, respectively. The results were summarized as follows : Seeding 5% of microorganism was higher the temperature than not seeding. And using sawdust as bulking agents, and adjusting 30~40 of Initial C/N ratio, 200ml/l.min. of k flow rate and 67~68% moisture contents were higher the temperature than any other conditions. Seeding 5% of microorganisms was higher $CO_2$ generation amount than not seeding. And that was much in the order of 7~40, 30~34 and 22~23 of initial C/N ratio. Judging from the results, it should be considered that the optimum conditions in the composting of industrial wastewater sludge were seeding of 5% microorganisms, and adjusting 30~34 of Initial C/N ratio, 200ml/l min. of air flow rate and 67~68% of Intitial moisture contents. The contents of inorganic matters and C/N ratio during the composting periods at optimum condition were a little Increased. and heavy metals contents after composting were lower than standard for fortllizer.

  • PDF

Determination of Mixing Ratio of Mixed Refrigerants and Performance Analysis of Natural Gas Liquefaction Processes (혼합냉매 혼합비에 따른 천연가스 액화공정 성능 비교)

  • Kim, Min Jin;Yi, Gyeong Beom;Liu, Jay
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.677-684
    • /
    • 2013
  • A mixed refrigerant cycle (MRC) has been widely used in liquefaction of natural gas because it is simple and easily operable with reasonable equipment costs. One of the important techniques in MRC is selection of a refrigerant mixture and decision of its optimum mixing ratio. In this work, it is examined whether mixture components (refrigerants) and their mixing ratio influence performance of general MRC processes. In doing this, mixture design and response surface method, which are well-known statistical techniques, are used to find optimal mixture refrigerants and their optimal mixing ratio that minimize total energy consumption of the entire liquefaction process. A MRC process using several refrigerants and various mixing ratios is simulated by Aspen HYSYS and mixture design and response surface method are implemented using Minitab. According to the results, methane ($C_1$), ethane ($C_2$), propane ($C_3$) and nitrogen ($N_2$) are selected as best mixture refrigerants and the determined mixture ratio (mole ration) can reduce total energy consumption by up to 50%.