• Title/Summary/Keyword: C V A

Search Result 10,477, Processing Time 0.037 seconds

Study on the Sublimatographic Characters of Sulfur (황의 Sublimatographic Characters에 관한 연구)

  • Sohn, Jin-Un;Kim, Joo-Bong
    • Elastomers and Composites
    • /
    • v.7 no.1
    • /
    • pp.53-58
    • /
    • 1972
  • Sublimatographic study on the method of test for sulfur in the petroleum and rubber products was as following results: (1) The relation between the heating temperature$(t_h)$ and the vacuum condensing point(V.C.P.) of sulfur at different degree of vacuum appeared as Fig.4. The results were in good agreement with those expected from the $t_h-V.C.P$ curves of sublimatographic separation of sulfur. (2) The relation between the degree of vacuum and the V.C.P. at different heating temperature of sulfur appeared as follows; $$tv.c.p.=\alpha+{\beta}logP_{va}$$ (3) The V.C.P of sulfur could be physical property comparing with melting point and boiling point. (4) The relation between the V.C.P. and the quantity of sublimation of sulfur becomes quantitative as Fig.7.

  • PDF

Characteristics of Ni/SiC Schottky Diodes Grown by ICP-CVD

  • Gil, Tae-Hyun;Kim, Han-Soo;Kim, Yong-Sang
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.111-116
    • /
    • 2004
  • The Ni/SiC Schottky diode was fabricated with the $\alpha$-SiC thin film grown by the ICP-CVD method on a (111) Si wafer. $\alpha$-SiC film has been grown on a carbonized Si layer in which the Si surface was chemically converted to a very thin SiC layer achieved using an ICP-CVD method at $700^{\circ}C$. To reduce defects between the Si and $\alpha$-SiC, the surface of the Si wafer was slightly carbonized. The film characteristics of $\alpha$-SiC were investigated by employing TEM (Transmission Electron Microscopy) and FT-IR (Fourier Transform Infrared Spectroscopy). Sputterd Ni thin film was used as the anode metal. The boundary status of the Ni/SiC contact was investigated by AES (Auger Electron Spectroscopy) as a function of the annealing temperature. It is shown that the ohmic contact could be acquired beyond a 100$0^{\circ}C$ annealing temperature. The forward voltage drop at 100A/cm was I.0V. The breakdown voltage of the Ni/$\alpha$-SiC Schottky diode was 545 V, which is five times larger than the ideal breakdown voltage of the silicon device. As well, the dependence of barrier height on temperature was observed. The barrier height from C- V characteristics was higher than those from I-V.

A Study on Effectiveness Analysis Methods for V-C System: Applying Effective Based Operation (EBO) Methodology (효과기반 작전 방법론을 적용한 V-C 연동체계에서 전투효과 분석방법 연구)

  • Kim, Young-In;Hong, Yoon-Gee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1337-1345
    • /
    • 2012
  • The principle of Effective Based Operation applied to the Korean Theater resulted in measurable effects to win the minimum battle. Based on the finding, this study recommends the effect analysis methodology under the V-C interoperability system to acquire a weapon system. This method is followed as below; to confirm the effect data on the organized weapon system, to set MOE, MOP and effect considering the purpose of the analysis, to apply the appropriate operational concept and scenario on the weapon system, and then the available C Model is after action reviewed, adjusted, and given feedback. The V-C interoperability system enables to perform the real-time combat experiment under the virtual synthesized battlefield circumstances. The defensive battle organization and displacement of the future anti-tank guided weapon system was considered in the modeling process. Scenario was written, which encompasses company-level units and the battalion-level operation. Then the available AWAM was embodied and effect-analyzed, which formed the foundation of SBA.

MUC1-C influences cell survival in lung adenocarcinoma Calu-3 cells after SARS-CoV-2 infection

  • Kim, Dongbum;Maharjan, Sony;Kim, Jinsoo;Park, Sangkyu;Park, Jeong-A;Park, Byoung Kwon;Lee, Younghee;Kwon, Hyung-Joo
    • BMB Reports
    • /
    • v.54 no.8
    • /
    • pp.425-430
    • /
    • 2021
  • Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) induces coronavirus disease 2019 (COVID-19) and may increase the risk of adverse outcomes in lung cancer patients. In this study, we investigated the expression and function of mucin 1 (MUC1) after SARS-CoV-2 infection in the lung epithelial cancer cell line Calu-3. MUC1 is a major constituent of the mucus layer in the respiratory tract and contributes to pathogen defense. SARS-CoV-2 infection induced MUC1 C-terminal subunit (MUC1-C) expression in a STAT3 activation-dependent manner. Inhibition of MUC1-C signaling increased apoptosis-related protein levels and reduced proliferation-related protein levels; however, SARS-CoV-2 replication was not affected. Together, these results suggest that increased MUC1-C expression in response to SARS-CoV-2 infection may trigger the growth of lung cancer cells, and COVID-19 may be a risk factor for lung cancer patients.

An experimental study on the biological safety and compatability of P.V.C. made in Korea (한국산 P.V.C.의 생물학적 안정도 및 적합성에 대한 실험적 고찰)

  • Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.157-166
    • /
    • 1984
  • These biologic test procedures are designed to test the suitability of P.V.C. made in Korea intended for parenteral preparation, which were based on the U.S. Pharmacopeia XIX "Biologic Test-Plastic Container", Official from July 1, 1975. Healthy adult human blood and rabbits weighing 2\ulcorner.2Kg were used for test materials. Sample P.V.C. were sampled from the medical equipments made in Korea randomly and Control P.V.C. were sampled from the standardized Cobe and Polystan P.V.C. tubes. P.V.C. extract was prepared from a homogeneous P.V.C. samples by incubating 60 square centimeters of the sample per 20 millimeters of sterile pyrogen-free saline at 70\ulcorner for 72 hours or autoclaving at 120\ulcorner for 1 hour. The Implantation Test was designed to evaluate the reaction of living tissue to the plastic by the method of the implantation of the Sample itself into animal tissue. The Systemic Injection Test, the Intracutaneous Test, and the remainders were designed to determine the biological response of animals to plastics by the single-dose injection of specific extracts prepared from a Sample. The results are as follows; 1.Implantation Test - No significant difference for reactions was noted between the Sample treated animal and the Control after 72 hours of implantation. 2.Systemic Toxicity Injection Test - No sign of toxicity and/or death immediately after injection and at 4, 24, 48 hours respectfully after injection. 3.Intracutaneous Test - None of the animals treated with the Sample showed a significantly greater reaction than the observed in the animals treated with Blank. 4.Pyrogen Assay-Only one animal treated with the Sample showed the maximal rise of rectal temperature about 0.2\ulcorner after 3 hours of injection, but remainders showed no change. 5.Hemolytic Index - The positive Control tube of distilled water exhibited complete hemolysis while the negative Control tube and P.V.C. extract were negative demonstrating no hemolysis. 6.Cell Morphology of Erythrocytes and Leukocytes on Stored, Heparinized Human Blood -- There was no significant difference in the morphology of either the Control or Sample extract. 7.Clotting Mechanism of Human Blood in vitro - After allowing to the P.V.C. extract at room temperature for 5 Hours and at 10\ulcorner for 24 hours, there was no appreciable difference in Prothrombin Time under these conditions. 8.Clotting Mechanism of Rabbit in vivo - At the termination of 5 days after intraperitoneal injection of the P.V.C. extract, no significant changes in Clotting Time were observed. According to the above results, it could be concluded that the P.V.C. made in Korea was acceptable for parenteral preparation, especially treated with physiologic saline and/or human blood.man blood.

  • PDF

The Spectroscopic Study on the Role of C-terminal Region of T4 endonuclease V in the Interaction with DNA: NMR and Fluorescence Experiment (DNA와 상호작용에서 T4 endonuclease V의 C-말단 부위의 역할에 관한 분광학적 연구: 핵자기공명과 형광 실험)

  • Yu, Jun-Seok;Lihm, Hyung-Mi;Ihm, Hu-Kang;Shin, Jung-Hyu;Lee, Bong-Jin
    • YAKHAK HOEJI
    • /
    • v.40 no.2
    • /
    • pp.193-201
    • /
    • 1996
  • In order to study the role of C-terminal aromatic region of T4 endonuclease V in the interaction with substrate DNA, NMR and Fluorescence spectrum were recorded. Analysis of flu orescence emission spectra showed that C-terminal region of T4 endonuclease V is in or very near the binding site. In the HSQC spectrum of $^{15}N$-Tyr-labeled T4 endonuclease V*DNA complex, the broadening of a peak was observed. It is presumed that this peak corresponds to one among three tyrosine residues which belong to the WYKYY segment of C-terminal region of T4 endonuclease V. Interactions of peptide fragments consisting of C-terminal residues of T4 endonuclease V with DNAs(TT-, T^T-DNA) were investigated by NMR and Fluorescence experiment. The results suggest that two peptide fragments themselves bind to DNAs and their binding pattern is not an intercalation mode.

  • PDF

A Study on Composition and Dosimetry of the $CaSO_4$ Phosphors ($CaSO_4$ 열형광체의 조성과 선량측정에 관한 연구)

  • Lee, Duek-Kyu
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.59-64
    • /
    • 1998
  • [ $CaSO_4$ ] thermoluminescent phosphors was made by sintring the $CaSO_4$ after doping the transition elements Tm, Pd, Dy, V, Mo, Zr. The maximum Peaks are found in the measured $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr) TL glow curve at $130^{\circ}C,\;110^{\circ}C,\;140^{\circ}C,\;100^{\circ}C$, and $120^{\circ}C$ when the heating rate is $5^{\circ}C/sec$. The activation energy of the main peak has been estimated by the peak shape method. The estimated activation energies are 1.02eV, 1.32eV, 1.12eV, 0.80eV, and 1.17eV, respectively. The thermoluminescence process in $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr)are found to the 2nd order when the main peak of the glow curve is analyzed by peak shape method. The dose responses of $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr) phosphors are linear within $4{\times}10^{-4}{\sim}1Gy$ of X-rays.

  • PDF

Physical and Chemical Evaluations of Refregerated Flatfish Treated with Organic Acids (유기산으로 처리한 냉장 광어의 이화학적 평가)

  • 김광현;김창렬
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.3
    • /
    • pp.334-339
    • /
    • 1998
  • Flatfish strips were treated with 0.5%(v/v) acetic acid(AA), 0.5%(v/v) lactic acid(LA), or 0.5%(v/w) citric acid(CA) for 5 min. All strips were individually placed in Whirl-Pak sample bags and stored at 4 or 10$^{\circ}C$. pH, TBA, color, and sensory quality of strips were evaluated after 0, 3, 6, 9, and 12 days of storage time. The pH of samples treated with AA for 5 min ranged from 5.39 to 6.64 for 12 days at 4$^{\circ}C$, which had a significantly (P<0.05) lower level compared to the controls during storage time. Acid treatments had a significantly (P<0.05) higher levels of TBA values compared to the controls for 12 days at 4$^{\circ}C$. All acid treatments had lower Hunter a and b color scores compared to the controls. Acid treatments were liked less by sensory panels than the fresh control due to acidic odor and flesh discoloration.

  • PDF

Integral C-V Converter for a Fully Differential Capacitive Pressure Sensor (완전차동용량형 압력센서를 위한 적분형 C-V 변환기)

  • Lee, Dae-Sung;Kim, Kyu-Chull;Park, Hyo-Derk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.9
    • /
    • pp.62-71
    • /
    • 2002
  • An intergral C-V converter is proposed to solve the nonlinearity problem of capacitive pressure sensors. The integral C-V converter consists of a switched-capacitor integrator and a switched-capacitor differential amplifier. It converts the sensor capacitance change which is inversely proportional to an applied pressure into a linear voltage output. Various PSPICE simulations prove that the convertor has excellent characteristics, such as low nonlinearity less than 0.01%/FS and low sensitivity to parallel offset capacitance and parasitic capacitance for the displacement range of sensor diaphragm set to 0 ${\sim}$ 90% of the initial distance between the electrodes in the simulation. We also show that the offset compensation and the gain trimming are easily achieved with the integral C-V converter.

미생물을 이용한 원유 및 원유제품의 분해 특성

  • O, Gyeong-Taek;Park, Gwi-Hwan;Lee, Jeong-Il;Lee, Jung-Gi;Kim, Seong-Jun;Motoki, Kubo;Jeong, Seon-Yong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.435-438
    • /
    • 2000
  • Crude oil-degrading microorganisms, Acinetobacter sp. A132, Pseudomonas aeruginosa F722, and Acinetobacter calcoaceticus OM1 were isolated from soil and sea. The optimal temperature of strain A132 and strain F722 on growth isolated from soil was $35^{\circ}C$ both, and also their growth were optimized at pH 8 and 9, respectively. The growth of the strains, A132 and F722, showed that crude oil of 2% (w/v) in culture broth in which crude oil was used as carbon and energy sources appeared to be an optimum. Optimal culture conditions of strain OM1 were different from those of the soil microorganisms except for temperature. The growth of strain OM1 was optimized at pH 7 and crude oil of 3.0% (w/v). The degradability to crude oil by strain A132 showed maximum $5.49g/\;l\;{\cdot}\;day$ under the conditions of $25^{\circ}C$, NaCl of 1.0% (w/v), and crude oil of 2.0% (w/v). The highest degradability of strain F722 to crude oil was $1.19g/\;l\;{\cdot}\;day$ under the culture conditions at $35^{\circ}C$, NaCl 1.0% (w/v), and crude oil of 2.0% (w/v). The degradation characteristics of kerosene $(nC_9-nC_{20})$ and diesel $(nC_9-nC_{28})$ by strain OM1, and F722 were analyzed by gas chromatography. Strain OM1 degraded more than 95% of kerosene and 75% of diesel for 7 days cultivation. Strain F722 showed degradation of more than 80% to kerosene in 10 days.

  • PDF