• Title/Summary/Keyword: C/R

Search Result 18,346, Processing Time 0.043 seconds

Effects of Specimen Size and Side-groove on the Results of J-R Fracture Toughness Test for LBB Evaluation (LBB 평가를 위한 J-R 파괴인성시험 결과에 미치는 시편 형상과 측면 홈의 영향)

  • Kim, Jin Weon;Choi, Myung Rak;Oh, Young Jin;Park, Heung Bae;Kim, Kyung Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.7
    • /
    • pp.729-736
    • /
    • 2015
  • In this study, the effects of specimen size and side-groove on the results of the J-R test for leak-before-break (LBB) evaluation were investigated. A series of J-R tests were conducted at both RT and $316^{\circ}C$, using three different sizes of compact tension (CT) specimens machined from SA508 Gr.1a piping material: 12.7 mm-thick 1T-CT, 25.4 mm-thick 1T-CT, and 25.4 mm-thick 2T-CT with and without side-groove. The results showed that side-grooving reduced the J-R curve for all specimens and the effect of side-grooving was more significant at $316^{\circ}C$ than at RT. As the thickness of the specimens decreased and the width of the specimens increased, the J-R curve slightly decreased at RT but it increased at $316^{\circ}C$. However, the variation in the J-R curve of SA508 Gr.1a with the thickness and width of CT specimen was insignificant.

Functional Analysis and Selection of Second-site Revertant of Escherichia coli 16S rRNA of C770G (Escherichia coli 16S rRNA 상의 770 위치에 염기치환을 가진 변이체 리보솜의 단백질 합성 능력을 회복시키는 이차복귀돌연변이체의 발췌)

  • Ha, Hye-Jeong;Ryou, Sang-Mi;Lee, Kang-Seok;Jeon, Che-Ok
    • Microbiology and Biotechnology Letters
    • /
    • v.39 no.1
    • /
    • pp.93-96
    • /
    • 2011
  • It has been shown that a nucleotide substitution at position 770 in Escherichia coli 16S rRNA, which is implicated in forming the evolutionary conserved B2c intersubunit bridge, has a detrimental effect on ribosome function. In order to isolate second-site revertants that complement ribosomes containing C770G, we performed a random mutagenesis of the 16S rRNA gene and selected clones that could produce more CAT protein translated by specialized ribosome. One of the clones contained two nucleotide substitutions at positions 569 and 904 (C569G and U904C) and these mutations partially complemented the loss of protein-synthesis ability caused by C770G. Further studies using the isolated revertant will provide information about which part of 16S rRNA is interacting with C770 and the consequence of the structure formed by these interactions in the process of protein synthesis.

Comparison of Exergy in a Refrigerating System using R404A and R134a for a Refrigeration Truck with Operating Conditions (운전조건에 따른 R404A와 R134a를 적용한 냉동탑차용 냉장시스템의 엑서지 비교)

  • Shin, Yunchan;Kim, Taejung;Cho, Honghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.497-503
    • /
    • 2014
  • The performances of refrigeration truck systems using R404A and R134a were investigated by experimental testing, and compared. The optimal COPs of the R404A and R134a systems were 2.96 and 3.42, when the refrigerant charge amount was 1.3 kg and 1.4 kg, respectively. When the indoor side air temperature increased from $5^{\circ}C$ to $9^{\circ}C$, the total exergy destruction rate of the R404A system was on average 39.1% higher than that of the R134a system. In addition, the exergy efficiency of the R404A system was 12.9% higher than that of R134a system, for various indoor air temperatures. When the outdoor side air temperature increased from $25^{\circ}C$ to $35^{\circ}C$, the total exergy destruction rate of the R404A and R134a systems decreased by 18.9% and 19.5%, respectively. In addition, the exergy efficiency of the R404A and R134a systems increased by 25.2% and 30.7%, respectively. As the compressor rotating speed increased, the COP of the R404A and R134a systems decreased by 23.6% and 18.4%. The total exergy destruction rate and exergy efficiency of the R404A system were 27.2% and 15.7% higher than those of R134a system, respectively. Compared to the R404A system, the R134a system showed a higher COP and a lower exergy destruction rate; thus it can be concluded that the R134a system has the better performance.

Di- and Triorganotin(IV) Complexes of Sulfur-containing Ylidenemalonates

  • Jung, Ok-Sang;Lee, Young-A;Hong, Jong-Ki;Jeong, Jong-Hwa;Sohn, Youn-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.6
    • /
    • pp.722-726
    • /
    • 1993
  • Organotin(IV) complexes of ylidenemalonates $(R_xSn)_{x-1}(O_2C)_2C=C(SR')_2\;(R=n-C_4H_9,\;C_6H_5,\;cyclo-C_6H_{11},\;CH_3OOCCH_2CH_2;\;x=2,3;\;R'=CH_3,\;R_2'=-CHCH-,\;-CH_2CH_{2^-})$ have been synthesized and characterized by means of various spectroscopic methods. The X-ray crystal structure of $(Ph_3Sn)_2(O_2C)_2C=C(SCH_3)_2$ has been determined (Pi; a= 9.704(2) ${\AA}$, b= 14.412(1) ${\AA}$, c= 14.760(3) ${\AA}$, ${alpha}$=74.26(1)$^{\circ}$, ${beta}$=99.38(l)$^{\circ}$, ${\gamma}$=79.09(1)$^{\circ}$, $V= 1950.7(7){\AA}^3$) and refined to R= 0.045. The crystal structure discloses a discrete molecule with bidentate-like carboxylate ligand. For diorganotin analogues, the structures are discussed in terms of IR, $^1H-NMR,\;^{13}C-NMR$, and FAB mass spectrometry. The mass spectrum indicates that the diorganotin complexes of ylidenemalonates are dimeric.

Automatic Construction of SHACL Schemas for RDF Knowledge Graphs Generated by R2RML Mappings

  • Choi, Ji-Woong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.8
    • /
    • pp.9-21
    • /
    • 2020
  • With the proliferation of RDF knowledge graphs(KGs), there arose a need of a standardized schema representation of the graph model for effective data interchangeability and interoperability. The need resulted in the development of SHACL specification to describe and validate RDF graph's structure by W3C. Relational databases(RDBs) are one of major sources for acquiring structured knowledge. The standard for automatic generation of RDF KGs from RDBs is R2RML, which is also developed by W3C. Since R2RML is designed to generate only RDF data graphs from RDBs, additional manual tasks are required to create the schemas for the graphs. In this paper we propose an approach to automatically generate SHACL schemas for RDF KGs populated by R2RML mappings. The key of our approach is that the SHACL shemas are built only from R2RML documents. We describe an implementation of our appraoch. Then, we show the validity of our approach with R2RML test cases designed by W3C.

ON Φ-FLAT MODULES AND Φ-PRÜFER RINGS

  • Zhao, Wei
    • Journal of the Korean Mathematical Society
    • /
    • v.55 no.5
    • /
    • pp.1221-1233
    • /
    • 2018
  • Let R be a commutative ring with non-zero identity and let NN(R) = {I | I is a nonnil ideal of R}. Let M be an R-module and let ${\phi}-tor(M)=\{x{\in}M{\mid}Ix=0\text{ for some }I{\in}NN(R)\}$. If ${\phi}or(M)=M$, then M is called a ${\phi}$-torsion module. An R-module M is said to be ${\phi}$-flat, if $0{\rightarrow}{A{\otimes}_R}\;{M{\rightarrow}B{\otimes}_R}\;{M{\rightarrow}C{\otimes}_R}\;M{\rightarrow}0$ is an exact R-sequence, for any exact sequence of R-modules $0{\rightarrow}A{\rightarrow}B{\rightarrow}C{\rightarrow}0$, where C is ${\phi}$-torsion. In this paper, the concepts of NRD-submodules and NP-submodules are introduced, and the ${\phi}$-flat modules over a ${\phi}-Pr{\ddot{u}}fer$ ring are investigated.

Performance of a room air conditioner using R410A according to the variation of outdoor temperature (실외온도 변화에 따른 R410A 적용 에어콘 시스템의 성능)

  • 김병순;이승홍
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.537-541
    • /
    • 1999
  • The system performance of a room air conditioner using R410A was experimentally evaluated and compared with that of R22 system. The results indicated that the cooling EER(energy efficiency ratio) of R410A was 1% higher than that of R22 at the outdoor temperature of $35^{\circ}C$. As outdoor temperature increases above $35^{\circ}C$ ambient, EER of the R410A system decreased more substantially compared with R22 system. R410A showed higher compressor discharge temperature than that of R22 system at the outdoor temperature of higher than $50^{\circ}C$.

  • PDF

Euler-Maruyama Numerical solution of some stochastic functional differential equations

  • Ahmed, Hamdy M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.11 no.1
    • /
    • pp.13-30
    • /
    • 2007
  • In this paper we study the numerical solutions of the stochastic functional differential equations of the following form $$du(x,\;t)\;=\;f(x,\;t,\;u_t)dt\;+\;g(x,\;t,\;u_t)dB(t),\;t\;>\;0$$ with initial data $u(x,\;0)\;=\;u_0(x)\;=\;{\xi}\;{\in}\;L^p_{F_0}\;([-{\tau},0];\;R^n)$. Here $x\;{\in}\;R^n$, ($R^n$ is the ${\nu}\;-\;dimenional$ Euclidean space), $f\;:\;C([-{\tau},\;0];\;R^n)\;{\times}\;R^{{\nu}+1}\;{\rightarrow}\;R^n,\;g\;:\;C([-{\tau},\;0];\;R^n)\;{\times}\;R^{{\nu}+1}\;{\rightarrow}\;R^{n{\times}m},\;u(x,\;t)\;{\in}\;R^n$ for each $t,\;u_t\;=\;u(x,\;t\;+\;{\theta})\;:\;-{\tau}\;{\leq}\;{\theta}\;{\leq}\;0\;{\in}\;C([-{\tau},\;0];\;R^n)$, and B(t) is an m-dimensional Brownian motion.

  • PDF

Evaluation of Norudia® HbA1c Kit for Glycohemoglobin Assay (당화혈색소 측정을 위한 Norudia® HbA1c 키트의 평가)

  • Hong, Seung-Bok;Kim, Eun-Joong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.37-41
    • /
    • 2009
  • Measurement of hemoglobin A1c is used as an objective indicator of long-term blood glucose control in diabetic patients. We evaluated recently introduced Norudia$^{(R)}$ HbA1c (Daiichi Pure Chemical Co. Ltd, Tokyo, Japan) test reagent using enzyme method for HbA1c assay. Linearity, precision and correlation with VARIANT$^{TM}$ II Turbo HbA1c analyzer (BIO-RAD, Hercules, CA, USA) were evaluated. The reference range was determined from 201 healthy subjects. The Norudia$^{(R)}$ HbA1c test reagent was founded to be linear in a range of 5.6% to 14.0% ($r^2=0.9885$). The within-run and between-day precision were 0.954% and 1.03% for low level (HbA1c 5.24%), 0.67% and 1.28% for high level (HbA1c 9.01%), respectively. Comparison study between Norudia$^{(R)}$ HbA1c test reagent and VARIANT$^{TM}$ II Turbo showed good correlation with a slope of 1.0489. an intercept at -0.9717, and coefficient of correlation was 0.9907. The reference range of HbA1c obtained from this reagent was 4.07-5.50%. The Norudia$^{(R)}$ HbA1c test reagent showed good linearity, precision and correlation with HbA1c analyzer with HPLC method. In addition, the exclusive analyzer is not required for assay and then this kit may be useful for HbA1c assay in clinical laboratory.

  • PDF