• Title/Summary/Keyword: Bypass circuit

Search Result 75, Processing Time 0.023 seconds

Effect of Pulsatile Versus Nonpulsatile Blood Flow on Renal Tissue Perfusion in Extracorporeal Circulation (체외순환에서 박동 혈류와 비박동 혈류가 신장의 조직관류에 미치는 영향)

  • Kim Hyun Koo;Son Ho Sung;Fang Yang Hu;Park Sung Young;Kim Kwang Taik;Kim Hark Jei;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.1 s.246
    • /
    • pp.13-22
    • /
    • 2005
  • It has been known that pulsatile flow is physiologic and more favorable to tissue perfusion than nonpulsatile flow. The purpose of this study is to directly compare the effect of pulsatile versus nonpulsatile blood flow to renal tissue perfusion in extracorporeal circulation by using a tissue perfusion measurement system. Material and Method: Total cardiopulmonary bypass circuit was constructed to twelve Yorkshire swines, weighing 20$\~ $30 kg. Animals were randomly assigned to group 1 (n=6, non pulsatile centrifugal pump) or group 2 (n=6, pulsatile T-PLS pump). A probe of the tissue perfusion measurement system $(QFlow^{TM}-500)$ was inserted into the renal pa­renchymal tissue. Extracorporeal circulation was maintained for an hour at a pump flow of 2 L/min after aortic cross-clamping. Tissue perfusion flow of the kidney was measured at baseline (before bypass) and every 10 minutes after bypass. Serologic parameters were collected at baseline and 60 minutes after bypass. Result: Baseline parameters were not different between the groups. Renal tissue perfusion flow was substantially higher in the pulsatile group throughout the bypass (ranged 48.5$\~$ 64 in group 1 vs. 65.8$\~$88.3 mL/min/100 g in group 2, p=0.026$\~$ 0.45) The difference was significant at 30 minutes bypass $(47.5{\pm}18.3\;in\;group\;1\;vs.\;83.4{\pm}28.5$ mL/min/100 g in group 2, p=0.026). Serologic parameters including plasma free hemoglobin, blood urea nitrogen, and creatinine showed no differences between the groups at 60 minutes after bypass (p=NS). Conclusion: Pulsatile flow is more beneficial to tissue perfusion of the kidney in short-term extracorporeal circulation. Further study is suggested to observe the effects to other vital organs or long-term significance.

The Effects of Heparin-Coated Circuit on the Total Amount of Heparin During Cardiopulmonary Bypass (심폐기 사용 중에 HCC가 총 Heparin사용량에 미치는 영향)

  • 이현우;이재웅;박철현;박국양
    • Journal of Chest Surgery
    • /
    • v.33 no.12
    • /
    • pp.954-958
    • /
    • 2000
  • 배경: 헤파린표면처리 도관(Heparin-coated circuit: HCC)이 도관과 혈액사이의 반응(Blood-marterial reaction)을 줄여주어서 보체활성화(complement activation), 백혈구활성화(leukocyte activation)와 사이토킨 분비(cytokinerelease)등을 감소시켜 준다. 그러나 HCC가 수술 후에 출혈 양을 줄여주고 헌혈 필요량을 감소시켜 준다는 임상적 효과에 대해서는 인정된 부분이 많으나 아직까지 그 기전은 대부분은 미지의 상태로 남아있는 것이 사실이다. 본 연구는 HCC를 사용한 군(Group H)과 사용하지 않은 군(Group C)간에 심폐기 사용기간(Pumptime), 활성화 응고시간(activated clotting time: ACT)과 헤파린 사용량을 비교 분석해 봄으로서 두 군간에 존재할 수 있는 헤파린 사용량을 비교 분석해 본으로서 두 군간에 존재할 수 있는 헤파린 사용량 차이에 대하여 알아보려고 하게되었다. 대상 및 방법: 본원에서 1999년 5월 1일부터 동년 12월 31일 사이에 연령이 16세 이상인 환자에서 HCC를 사용했던 16명(Group H)과 사용하지 않았던 19명(Group C)을 대상으로 하였다. 모든 환자에서 수술 전 체중, 신장, 체표면적, 심폐기 사용시간(pumptime), 수술 중 최저체온, 대동맥 차단시간(Aortic cross clamping time. ACC time), ACT, 헤파린 및 프로타민 사용 양 등을 조사하였다. 결과: 연구대상 환자의 연령, 체중, 신장, 체표면적, 대동맥차단 시간, 체온 등은 HCC를 사용한 군(H 군)과 사용하지 않은 군(C군)간에 의미 있는 차이가 없었다(p<0.05). 헤파린 공급 전, 공급 후 20분, 40분, 60분과 프로타민 공급 후 20분에 측정한 ACT는 두 군간에 의미 있는 차이가 없었다. 두 군간의 처음에 공급한 헤파린 양과 총 프로타민 사용량은 차이가 없었으나(p>0.05), 추가 공급한 헤파린 양(11$\pm$30 versus 67$\pm$49mg, p<0.05)과 총 헤파린 사용량(176$\pm$44 versus 239$\pm$70mg, p<0.05)은 H군에서 의미 있게 적게 나왔다. 두 군간에서 심폐기 사용시간에는 차이가 없었으면서 H군에서 약 38%정도의 헤파린을 적게 사용하였다. 결론: 결론적으로 HCC의 사용으로 심폐기 사용 시간과 상관없이 추가하는 헤파린 양을 줄임으로서 총 헤파린 사용량을 줄여 줄 수 있었으며 이것이 HCC의 임상적 효과를 나타나게 하는 하나의 요소로 작용할 수 있다고 생각된다.

  • PDF

Single-phase Uninterruptible Power Supply employing Superconducting Magnet Energy Storage Unit

  • Kang, Feel-Soon
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.362-368
    • /
    • 2007
  • A single-phase uninterruptible power supply system equipped with a superconducting magnet energy storage unit is proposed to achieve a simple circuit configuration and higher system reliability. It reduces a number of switching devices by applying a common-arm scheme. Removing some switches or substituting passive elements for active switches can increase the sophistication and reduces degree of freedom in control strategy. However, high-performance DSP controller can execute the complicated control task with no additional cost. Operational principles to normal, stored-energy, and bypass mode are discussed in detail. The validity of the proposed system is verified by experimental results.

A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting (착상을 수반한 멀티 가변속 열펌프의 동특성)

  • ;;Shigeru Koyama
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.

A Family of Non-Isolated Photovoltaic Grid Connected Inverters without Leakage Current Issues

  • Ji, Baojian;Wang, Jianhua;Hong, Feng;Huang, Shengming
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.920-928
    • /
    • 2015
  • Transformerless solar inverters have a higher efficiency than those with an isolation link. However, they suffer from a leakage current issue. This paper proposes a family of single phase six-switch transformerless inverter topologies with an ac bypass circuit to solve the leakage current problem. These circuits embed two unidirectional freewheeling current units into the midpoint of a full bridge inverter, to obtain a freewheeling current path, which separates the solar panel from the grid in the freewheeling state. The freewheeling current path contains significantly fewer devices and poor performance body diodes are not involved, leading to a higher efficiency. Meanwhile, it is not necessary to add a voltage balancing control method when compared with the half bridge inverter. Simulation and experiments are provided to validate the proposed topologies.

Development of Simulation Program for Multi-Air conditioner (멀티에어컨의 성능해석 프로그램 개발)

  • Jeong, B.Y.;Koh, J.Y.;Park, B.D.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.63-72
    • /
    • 2000
  • In this study, theoretical simulation method for the steady state characteristics of a refrigeration cycle which consists of one condenser and multi-evaporator (Multi-air conditioner) is presented. The simulation was performed for a typical multi-air conditioning system consisted one outdoor unit with air-cooled condenser, compressor, linear electric expansion valve and bypass circuit and connected three-evaporators (three indoor units). The simulation results are good agreement with those of experiments within 5 $\sim$ 10% at the given system operation conditions which are condensing pressure, evaporating pressure, sub-cooled degree of condenser, superheated degree, discharge temperature of compressor and pulse of linear electric expansion valve.

  • PDF

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

Short-Circuit Test of ITER CS AC/DC Converter (ITER CS AC/DC 컨버터 단락시험)

  • Kim, B.C.;Oh, J.S.;Choi, J.W.;Suh, J.H;Jo, S.M
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.107-108
    • /
    • 2018
  • ITER AC/DC 컨버터는 토카막 시스템의 안전성 확보를 위하여 단락 조건에서의 높은 내구성이 요구된다. 단락시험은 크게 컨버터 출력단 단락시험과 컨버터 내부 단락시험으로 구분된다. 컨버터 출력단 단락시험은 단락시험 조건에서의 전력장치의 내구성과 브릿지 스위치의 전류 분배특성 및 Bypass 스위치 동작 특성을 확인하기 위한 것이며, 컨버터 내부 단락시험은 기계적 구조물 안전성 검증을 위한 것이다. ITER CS AC/DC 컨버터의 단락시험은 전기연구원에서 시행되었으며 본 논문에서는 컨버터 출력단 단락시험 결과를 소개하고자 한다.

  • PDF

An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities (정보통신설비용 뇌서지 보호장치의 효과적인 설치기법)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.90-96
    • /
    • 2002
  • The AC power lines and signal lines of info-communication networks are muted on overhead poles and are exposed to lightning strikes. Due to the potential difference between groundings of the AC power lines and telecommunication lines, the electronic equipments connected to the telecommunication lines can easily be damaged by lightning surges. In this work, in order to develop the reliable ways to protect information and communication facilities from lightning surges, the reliability and performance of surge protective devices were experimentally investigated in actual-sized test circuit. The operation behaviors of surge protective devices against lightning surges from the AC power lines and telecommunication lines and the coordination effects of SPD installation method were evaluated. As a consequence, it was confirmed that the bypass arrester and common grounding system is very effective.

Development of Boost Chopper with Built New Renewable Energy in Grid-Connected Distributed Power System (승압 초퍼 기능이 내장된 새로운 태양광 발전용 파워컨디셔너의 개발)

  • Mun, Sang-Pil;Lee, Su-Haeng;Kim, Young-Mun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.361-367
    • /
    • 2014
  • This paper is related to a new solar power conditioner for a built-in step-up chopper function. In the first step-up chopper proposed solar PV power conditioner for mutually connected in series with the input voltage of the bypass diodes are respectively connected to the positive terminal should install the mutual boosting chopper diode connected in series with the boost chopper switching element between the two power supply and at the same time the first and the second was connected to a second diode and a resonance inductor and a snubber capacitor in series with each other. And the common connection point between the bypass diode and the step-up chopper and the step-up chopper diode common connection point of the switching elements of the input voltage was set to the boost inductor for storing energy. In addition, between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point of the first auxiliary diode and the second common connection point of the auxiliary diode was provided, the resonance capacitor. Between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point and the common connection point of the resonance inductor snubber capacitor and connecting the third secondary diode, between two power supply lines is characterized by configuring the DC link capacitor bus lines in parallel. Therefore, it is possible to suppress the switching loss through, DC link bus lines, as well as there could seek miniaturization and weight reduction of the power conditioner itself by using a common capacitor of the non-polar non-polar electrolytic capacitor having a capacitor, the service life of the circuit can be extended and it is possible to greatly reduce the loss can be greatly improve the reliability of the product and the operation of the product itself.