• 제목/요약/키워드: Bus-only signal

검색결과 30건 처리시간 0.027초

대규모 전력계통의 미소신호 안정도 해석을 위한 선형해석 프로그램 개발 (Development Of Small Signal Stablility Linear Analysis Program for Large Scale Power System.)

  • 송성근;남해곤;심관식;김용구;김동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1054-1056
    • /
    • 1999
  • It is the most important in small signal stability analysis of large scale Power systems to compute only the dominant eigenvalues selectively with numerical stability and efficiency. In this Paper evoluted linear analysis program, transformed state matrix using Inverse transformation with complex shift and then Hessenberg process and iterative scheme are used to accelerate Hessenberg process, can calculate dominant eigenvalues. In this Paper, The accuracy of this Program has been validated against 4-machines 11-bus system and New England 10-machines 39-bus system. Also applied to KEPCO system - about 791-bus 250-machines 2500-branches, got 2568 order state matrix, and calculated two dominant modes. This analysis result equaled to result of EPRI's SSSP program to use commonly, and calculating time is faster.

  • PDF

UTIS를 활용한 수요 기반의 능동형 버스우선신호 제어 알고리즘에 관한 연구 (A Study on the Active Transit Signal Priority Control Algorithm based on Bus Demand using UTIS)

  • 홍경식;정준하;안계형;이영인
    • 대한교통학회지
    • /
    • 제29권6호
    • /
    • pp.107-116
    • /
    • 2011
  • 본 연구에서는 수도권을 중심으로 구축 운영 중인 UTIS를 활용하여 버스의 서비스 개선 및 운행 효율성을 증진함과 동시에 일반 차량의 지체를 최소화하기 위한 버스 수요 기반의 TSP 제어 알고리즘을 개발하였다. 이를 위해 버스의 수요를 기반으로 버스 우선신호의 우선권 강도를 조정하는 알고리즘을 제안하였으며, 주도로의 버스 우선권 제공으로 인한 부도로의 지체 증가를 막기 위해 부도로의 포화도에 따른 우선권 강도를 조정하는 보상 알고리즘을 제안하였다. 또한 연구 결과를 CORSIM RTE를 활용할 HILS 기반의 평가시스템을 통해 효과 분석하여 현장의 적용 가능성을 검증하였다. 시뮬레이션 결과 버스의 통행시간은 10% 정도 개선 효과가 있었으나, 이 경우 전체차량의 제어지체에는 큰 영향을 받지 않음을 확인하였다. 이러한 연구 결과는 국내의 대중교통 활성화 정책에 기여할 것으로 기대된다.

A Novel DC Bus Voltage Balancing of Cascaded H-Bridge Converters in D-SSSC Application

  • Saradarzadeh, Mehdi;Farhangi, Shahrokh;Schanen, Jean-Luc;Frey, David;Jeannin, Pierre-Olivier
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.567-577
    • /
    • 2012
  • This paper introduces a new scheme to balance the DC bus voltages of a cascaded H-bridge converter which is used as a Distribution Static Synchronous Series Compensator (D-SSSC) in electrical distribution network. The aim of D-SSSC is to control the power flow between two feeders from different substations. As a result of different cell losses and capacitors tolerance the cells DC bus voltage can deviate from their reference values. In the proposed scheme, by individually modifying the reference PWM signal for each cell, an effective balancing procedure is derived. The new balancing procedure needs only the line current sign and is independent of the main control strategy, which controls the total DC bus voltages of cascaded H-bridge. The effect of modulation index variation on the capacitor voltage is analytically derived for the proposed strategy. The proposed method takes advantages of phase shift carrier based modulation and can be applied for a cascaded H-bridge with any number of cells. Also the system is immune to loss of one cell and the presented procedure can keep balancing between the remaining cells. Simulation studies and experimental results validate the effectiveness of the proposed method in the balancing of DC bus voltages.

데이터 충돌을 고려한 네트워크형 분산 제어 시스템 (Network Type Distributed Control System with Considering Data Collision)

  • 최군호
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.113-120
    • /
    • 2015
  • Network type distributed control system uses a communication line which is named the BUS to exchange a data among the sub-systems. Usually, on the bus, only one data must be exited at one time, so the control algorithm to prevent collision or to manage a priority of data is important. Including CAN Protocol, many kind of FieldBus which are used for distributed control system, prevent data collision by controlling transmission time. But, a system which have to make a control signal or get a data from a sensor at fixed time will be met a problem when it is composed by using a network type distributed control structure. In this paper, some of these cases will be discussed and solutions be proposed for preventing a data collision. Also, using Arago Disk System which have a structure for inner loop control, the validity of the proposed methods will be verified.

대규모 전력계통의 미소신호 안정도 해석을 위한 Hessenberg법 (Hessenberg Method for Small Signal Stability Analysis of Large Power Systems)

  • 남해곤;송성근;심관식;문채주;김동준;문영환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.168-176
    • /
    • 2000
  • This paper presents the Hessenberg method, a new sparsity-based small signal stability analysis program for large interconnected power systems. The Hessenberg method as well as the Arnoldi method computes the partial eigen-solution of large systems. However, the Hessenberg method with pivoting is numerically very stable comparable to the Householder method and thus re-orthogonalization of the krylov vectors is not required. The fractional transformation with a complex shift is used to compute the modes around the shift point. If only the dominant electromechanical oscillation modes are of concern, the modes can be computed fast with the shift point determined by Fourier transforming the time simulation results for transient stability analysis, if available. The program has been successfully tested on the New England 10-machine 39-bus system and Korea Electric Power Co. (KEPCO) system in the year of 2000, which is comprised of 791-bus, 1575-branch, and 215-machines. The method is so efficient that CPU time for computing five eigenvalues of the KEPCO system is 3.4 sec by a PC with 400 MHz Pentium IIprocessor.

  • PDF

TCSC의 소신호 모형을 이용한 점호각 제어에 의한 저주파 진동 감쇠 효과 해석 및 제어 (Analysis and Control of Low Frequency Oscillation using TCSC Small Signal Model by Control of Firing Angles)

  • 김태현;서장철;박종근;문승일;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.120-124
    • /
    • 1995
  • TCSC can not only increase power flow but also damp low frequency oscillation by controlling firing angles of thyristors. But, a model considering voltage, current firing angles is not derived. This paper used a small signal model considirng these variables which was derived in paper [1]. TCSC model is combined with swing equation. Being related to rotor angles and firing angles of thyristors, current and synchronizing torque coefficient is reformulated. Because firing angles of thyristors can be controlled only twice within one period, swing equation is transformed to discrete time model. It is shown that low frequency oscillation can be damped by controlling firing angles in one machine infinite bus power system.

  • PDF

전력시스템을 위한 Active Damping Device (An Active Damping Device for a Distributed Power System)

  • 나재두
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.116-121
    • /
    • 2009
  • Distributed power systems (DPSs) has been widely used various industrial/military applications due to their various advantages. Furthermore, the "All electric" concept, in conjunction with DC DPS, appears to be more advanced and mature in the AEV(All-Electric Vehicular) industry. Generally, AEV carry many loads with varied functions. However, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, a converter with spilt capacitors and a simple adaptive controller is proposed as a active damping device to mitigate the voltage transients on the bus. The proposed converter allows the smaller capacitive storage. In addition, the proposed control approach has the advantage of requiring only one sensor and performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. The control algorithm has been implemented on a TMS320F2812 Digital Signal Processor (DSP). Simulation and experimental results are presented which verify the proposed control principle and demonstrate the practicality of the circuit topology.

Development of compact environment control system using eye-ball movement

  • Shin, Young-Kyun;Muhammad, Arif;Hikaru, Inooka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.77.4-77
    • /
    • 2002
  • Communicating devices for the seriously disabled using eye-ball movement or some body movement are proposed. The first one is a device to use image processing, whose input signal is eyeball movement, A feature of this device is that the device can be readily realized using a note-book computer with USB (Universal Serial Bus) interface bus. This device is incorporated with a word processing software called Nearly Ladder. The second one is an emergency call switch which is used by a patient who can move his finger slightly. The patients can switch on the emergency switch only by touching a switch with his finger. The essence of this sensor is a touch sensor. The sensor can be realized using onl...

  • PDF

개선된 변류기 보상알고리즘을 적용한 모선보호용 비율전류차동 계전방식 (A Percentage Current Differential Relaying Algorithm for Bus Protection Using an Advanced Compensating Algorithm of the CTs)

  • 강용철;윤재성;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.158-164
    • /
    • 2003
  • This paper proposes a percentage current differential relaying algorithm for bus protection using an advanced compensating algorithm of the secondary current of current transformers (CTs). The compensating algorithm estimates the core flux at the start of the first saturation based on the value of the second-difference of the secondary current. Then, it calculates the core flux and compensates distorted currents using the magnetization curve. The algorithm Is unaffected by a remanent flux. The simulation results indicate that the proposed algorithm can discriminate internal faults from external faults when the CT saturates. This paper concludes by implementing the algorithm into a TMS320C6701 digital signal processor. The results of hardware implementation are also satisfactory. The proposed algorithm can improve not only stability of the relay in the case of an external fault but sensitivity of the relay in the case of an internal fault.

도시부 4지 신호교차로 유턴 사고모형 개발 (Development of the U-turn Accident Model at 4-Legged Signalized Intersections in Urban Areas)

  • 강종호;김경환;하만복;김성문
    • 한국도로학회논문집
    • /
    • 제16권2호
    • /
    • pp.119-129
    • /
    • 2014
  • PURPOSES : The purpose of this study is to develop the U-turn accident model at 4-legged signalized intersections in urban areas. METHODS : In order to analyze the characteristics of the accidents which are associated with U-turn operation at 4-legged signalized intersections in urban areas and develop an U-turn accident model by regression analysis, the tests of overdispersion and zero-inflation are conducted about the dependent variables of number of accidents and EPDO (Equivalent Property Damage Only). RESULTS : As their results, the Poisson model fits best for number of accident and the ZIP (Zero Inflated Poisson) fits best for EPOD, the variables of conflict traffic, width of opposing road, traffic passing speed are adopted as independent variable for both models. The variables of number of bus berths and rate of U-turn signal time at which the U-turn is permitted are adopted as independent variable only for EPDO. CONCLUSIONS : These study results suggest that U-turn would be permitted at the intersection where the width of opposing road is wider than 11.9 meters, the passing vehicle speed is not high and U-turn operation is not hindered by the buses stopping at bus stops.