• Title/Summary/Keyword: Bus operation

Search Result 624, Processing Time 0.033 seconds

Analysis of Traffic Characteristics for the Transportation Vulnerable (교통약자의 이동수단 이용특성 분석에 관한 연구 - 이동지수 산정 및 적용을 중심으로 -)

  • Jung, Hun Young;Lee, Sang Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.241-249
    • /
    • 2013
  • Since the enactment of "Mobility Promotion Law for Transportation Vulnerable", each municipality has been various efforts to improve the transportation vulnerable's the right of movement. However, the effectiveness of mobility promotion policy for the transportation vulnerable is awfully inadequate because circumstances which associated with operation of transportation of the handicapped such as local conditions and transport characteristics have not been considered. Thus, in this study investigated traffic characteristics of the transportation vulnerable through the data of regional slope, non-step buses and handicap vehicles operating conditions and so on in Busan Metropolitan. Also, we proposed to introduction of the 'mobility index' which is based on local condition analysis of Busan. And we suggested that how to improve the convenience of transportation vulnerable's movement.

Study on Fault Diagnosis Method of Train Communication Network applied to the prototype Korean High Speed Train

  • Cho, Chang-Hee;Park, Min-Kook;Kwon, Soon-Man;Kim, Yong-Ju;Kim, Sung-Shin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2169-2173
    • /
    • 2003
  • The development project of Korean High Speed Train (KHST) was started in 1996. As a national research project, the KHST project aims for a development of the next generation prototype train that has a maximum speed of 350 km/h. The development process of prototype KHST including 7 vehicles was completed last year and currently the prototype train is on its way of test running over the test track with gradually increased speed. The prototype KHST uses the real time network called TCN (Train Communication Network) for exchanging information between various onboard control equipments. After 10 years of development and modification period, TCN was confirmed as international standard (IEC61375-1) for the electrical railway equipment train bus. In the prototype KHST, all major control devices are connected by TCN and exchange their information. Such devices include SCU (Supervisory Control Unit), ATC (Automatic Train Control), TCU (Traction Control Unit), and so forth. For each device that sends and receives data using TCN, a device has to find out whether TCN is in normal or failure state before its data exchange. And also a device must have a proper method of data validation that was received in a normal TCN state. This is a one of the major important factors for devices using network. Some misleading information can lead the entire system to a catastrophic condition. This paper briefly explains how TCN was implemented in the prototype KHST train, and also shows what kind of the fault diagnosis method was adopted for a fail safe operation of TCN system

  • PDF

The National Standard Real Situation Conformance Test System for a Nation-wide Interoperable Transportation Card (전국호환 교통카드 국가 표준 실환경 적합성 평가)

  • Nam, Na-kyung;Lee, Soo-kyung;Lee, Ki-han
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.3
    • /
    • pp.68-76
    • /
    • 2016
  • The pre-paid nation-wide interoperable transportation card, which an pay fee of bus, subway, train, and highway with just one card, released in June. 2014. It has started and operated from Seoul, Gyeonggi, and major local metropolitan area. In this paper, after starting of service, we evaluate conformance and interoperability of nation-wide interoperable transportation card system in real situation. Through this, we check the status of its technical operation. For this, we choose 6 region included Seoul, Gyeonggi which are serviced by different transport vendors and check recognition and billing result from field of transportation card terminal. As a result, we can reach that the major nation-wide interoperable transportation card operate normally and deliver CONFIG DF query command. It means nation-wide interoperable transportation card system which use only one card stably adapt the public transport system and it can make user's public transport use convenience higher through the extension of service area.

Protection Strategies Against False Data Injection Attacks with Uncertain Information on Electric Power Grids

  • Bae, Junhyung;Lee, Seonghun;Kim, Young-Woo;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • False data injection attacks have recently been introduced as one of important issues related to cyber-attacks on electric power grids. These attacks aim to compromise the readings of multiple power meters in order to mislead the operation and control centers. Recent studies have shown that if a malicious attacker has complete knowledge of the power grid topology and branch admittances, s/he can adjust the false data injection attack such that the attack remains undetected and successfully passes the bad data detection tests that are used in power system state estimation. In this paper, we investigate that a practical false data injection attack is essentially a cyber-attack with uncertain information due to the attackers lack of knowledge with respect to the power grid parameters because the attacker has limited physical access to electric facilities and limited resources to compromise meters. We mathematically formulated a method of identifying the most vulnerable locations to false data injection attack. Furthermore, we suggest minimum topology changes or phasor measurement units (PMUs) installation in the given power grids for mitigating such attacks and indicate a new security metrics that can compare different power grid topologies. The proposed metrics for performance is verified in standard IEEE 30-bus system. We show that the robustness of grids can be improved dramatically with minimum topology changes and low cost.

The Study for Idle Fuel Consumption of a Hydrogen-Blended Natural Gas Engine (수소 혼합 천연가스 연료 엔진의 아이들 연비에 관한 연구)

  • Lee, Sun-Youp;Kim, Young-Min;Lee, Jang-Hee
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.171-176
    • /
    • 2010
  • Using a hydrogen blended compressed natural gas (HCNG) as a fuel for IC engines has a significant meaning in terms of achieving a reduction of automotive exhaust emissions as well as preparing for an upcoming hydrogen economy by constructing hydrogen infrastructure. In addition, a HCNG engine has higher thermal efficiency than a CNG engine, which is another advantage that makes HCNG fuel considered as a future alternative for natural gas. Therefore, in this study, idling operation of a 11 litre HCNG bus engine was investigated in terms of fuel consumption rate and emissions characteristics. The results show that fuel consumption rate was decreased more than 20% by use of HCNG and all the emissions were significantly reduced in idling condition.

Design of Fault Diagnostic and Fault Tolerant System for Induction Motors with Redundant Controller Area Network

  • Hong, Won-Pyo;Yoon, Chung-Sup;Kim, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.371-374
    • /
    • 2004
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Preventive maintenance of induction motors has been a topic great interest to industry because of their wide range application of industry. Since the use of mechanical sensors, such as vibration probes, strain gauges, and accelerometers is often impractical, the motor current signature analysis (MACA) techniques have gained murk popularity as diagnostic tool. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is independent of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module is checking stator current, voltage, temperatures, vibration and speed of the motor. The DSPs share information from each sensor or DSP through DPRAM with hardware implemented semaphore. And it communicates the motor status through field bus (CAN, RS485). From the designed system, we get primitive sensors data for the case of normal condition and two abnormal conditions of 3 phase induction motor control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using CAN protocol.

  • PDF

Bus Architecture Analysis for Hardware Implementation of Computer Generated Hologram (컴퓨터 생성 홀로그램의 하드웨어 구현을 위한 버스 구조 분석)

  • Seo, Yong-Ho;Kim, Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.713-720
    • /
    • 2012
  • Recently, holography has received much attention as the next generation visual technology. Hologram is obtained by the optical capturing, but in recent years it is mainly produced by the method using computer. This method is named by computer generated hologram (CGH). Since CGH requires huge computational amount, if it is implemented by S/W it can't work in real time. Therefore it should use FPGA or GPU for real time operation. If it is implemented in the type of H/W, it can't obtain the same quality as S/W due to the bit limitation of the internal system. In this paper, we analyze the bit width for minimizing the degradation of the hologram and reducing more hardware resources and propose guidelines for H/W implementation of CGH. To do this, we performs fixed-points simulations according to main internal variables and arithmetics, analyze the numerical and visual results, and present the optimal bit width according to application fields.

A harmonic reduction scheme for 12-pulse diode rectifiers by auxiliary voltage supply (보조전원장치에 의한 12-펄스정류기의 고조파 저감)

  • Kim, Sung-Hwan;Kim, Jong-Su;Oh, Sae-Gin;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.916-922
    • /
    • 2014
  • Diode rectifiers have been widely used for an AC to DC converter. But a big problem is that they include large harmonics components in the input currents. A 12-pulse configuration with phase shifting transformer is useful for reducing them. however, it still includes the ($12{\pm}1$)th (m; integer) harmonics in the input currents. In this paper, we propose a single-phase square wave auxiliary voltage supply which is inserted in the middle DC bus. It reduces harmonics especially the 11th and 13th and the harmonic characteristic becomes almost equivalent to a 24-pulse rectifier. Theoretical analysis of the combined 12-pulse diode rectifier with the auxiliary supply is presented and a control method of the auxiliary supply is proposed. The reduction in the input current harmonics is verified by simulation using software PSIM.

Design and Development of PCI-based 1553B Communication Software for Next Generation LEO On-Board Computer (차세대 저궤도 위성의 PCI 기반의 1553B 통신 소프트웨어 설계)

  • Choi, Jong-Wook;Jeong, Jae-Yeop;Yoo, Bum-Soo
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.65-71
    • /
    • 2016
  • Currently developing the OBC of the next-generation LEO satellite by Korea Aerospace Research Institute adopts the LEON2-FT/AT697F processor to achieve high performance. And various communication devices such as SpaceWire, MIL-STD-1553B, DMAUART and CAN Master are integrated to the separated standard communication FPGAs within the OBC, where they can be controlled by the processor and flight software (FSW) through PCI interface. The Actel 1553BRM IP core is used for the 1553B in the next-generation LEO OBC and the B1553BRM wrapper from Aeroflex Gaisler is used for connecting it to the AMBA bus in FPGA. This paper presents the design and development of PCI-based 1553B communication software, and describes the handling mechanism of 1553B operation in FSW task level. Also it shows the test results on real-hardware and simulator.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.