• Title/Summary/Keyword: Bus Off

Search Result 114, Processing Time 0.025 seconds

Design and Implementation of the Lamp Control System in Underground Parking Place using Web (웹을 이용한 지하주차장 조명제어시스템의 설계 및 구현)

  • Shon, Hyung-Do;Shin, Dong-Uk;Kang, Seung-Chan
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.3
    • /
    • pp.42-50
    • /
    • 2002
  • In this paper, we have designed and implemented lamp control system in underground parking place using WWW. The proposed system consists of lamp control system which is connected by RS-485 communication bus and monitoring system (WebPL) which can provide web interface using the web server. The lamp control system is controlled through a user command within the monitoring system (WebPL), senses moving object and turns lamps in underground parking place on or off. The monitoring system displays the status values of on or off received from lamp control system on the web browser and can real-timely control lamps in underground parking place on the web browser. 

A New High Frequency Linked Soft-Switching PWM DC-DC Converter with High and Low Side DC Rail Active Edge Resonant Snubbers for High Performance Arc Welder

  • Kang, Ju-Sung;Fathy, Khairy;Hong, Doo-Sung;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.281-283
    • /
    • 2006
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. The effectiveness of these new DC-DC converters topologies is proved for low voltage and large current high efficiency DC-DC power supplies as TIG arc welding machine from a practical point of view.

  • PDF

Implementation of an Interleaved AC/DC Converter with a High Power Factor

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.377-386
    • /
    • 2012
  • An interleaved bridgeless buck-boost AC/DC converter is presented in this paper to achieve the characteristics of low conduction loss, a high power factor and low harmonic and ripple currents. There are only two power semiconductors in the line current path instead of the three power semiconductors in a conventional boost AC/DC converter. A buck-boost converter operated in the boundary conduction mode (BCM) is adopted to control the active switches to achieve the following characteristics: no diode reverse recovery problem, zero current switching (ZCS) turn-off of the rectifier diodes, ZCS turn-on of the power switches, and a low DC bus voltage to reduce the voltage stress of the MOSFETs in the second DC/DC converter. Interleaved pulse-width modulation (PWM) is used to control the switches such that the input and output ripple currents are reduced such that the output capacitance can be reduced. The voltage doubler topology is adopted to double the output voltage in order to extend the useable energy of the capacitor when the line voltage is off. The circuit configuration, principle operation, system analysis, and a design example are discussed and presented in detail. Finally, experiments on a 500W prototype are provided to demonstrate the performance of the proposed converter.

A Novel Soft-Switching PWM DC/DC Converter with DC Rail Series Switch-Parallel Capacitor Edge Resonant Snubber Assisted by High-Frequency Transformer Parasitic Components

  • Fathy, Khairy;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.377-382
    • /
    • 2005
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. One topology of proposed DC-DC converters is composed of a typical voltage source-fed full-bridge high frequency PWM inverter using DC busline side series power semiconductor switching devices with the aid of a parallel capacitive lossless snubber. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. It is proved that the more the switching frequency of full-bridge soft switching inverter increases, the more soft-switching PWM DC-DC converter with a hish frequency transformer link has remarkable advantages for its efficiency and power density as compared with the conventional hard-switching PWM inverter type DC-DC converter

  • PDF

Novel Power Bus Design Method for High-Speed Digital Boards (고속 디지털 보드를 위한 새로운 전압 버스 설계 방법)

  • Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.23-32
    • /
    • 2006
  • Fast and accurate power bus design (FAPUD) method for multi-layers high-speed digital boards is devised for the power supply network design tool for accurate and precise high speed board. FAPUD is constructed, based on two main algorithms of the PBEC (Path Based Equivalent Circuit) model and the network synthesis method. The PBEC model exploits simple arithmetic expressions of the lumped 1-D circuit model from the electrical parameters of a 2-D power distribution network. The circuit level design based on PBEC is carried with the proposed regional approach. The circuit level design directly calculates and determines the size of on-chip decoupling capacitors, the size and the location of off-chip decoupling capacitors, and the effective inductances of the package power bus. As a design output, a lumped circuit model and a pre-layout of the power bus including a whole decoupling capacitors are obtained after processing FAPUD. In the tuning procedure, the board re-optimization considering simultaneous switching noise (SSN) added by I/O switching can be carried out because the I/O switching effect on a power supply noise can be estimated over the operation frequency range with the lumped circuit model. Furthermore, if a design changes or needs to be tuned, FAPUD can modify design by replacing decoupling capacitors without consuming other design resources. Finally, FAPUD is accurate compared with conventional PEEC-based design tools, and its design time is 10 times faster than that of conventional PEEC-based design tools.

Evaluation of the Impact of Fuel Economy by Each of Driving Modes for Medium-Size Low-Floor Bus (중형저상버스의 개별주행모드에 따른 연료소비율 평가)

  • Jung, Jae-wook;Ro, Yun-sik;Ahn, Byong-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.133-140
    • /
    • 2016
  • The Ministry of Land, Infrastructure and Transport has introduced low-floor buses, which are convenient for passengers getting on and off the bus and for the handicapped. The standard bus model is 11 m long and uses compressed natural gas (CNG). However, this model has drawbacks in narrow rural road conditions such as those in farming and fishing villages and mountainous areas, as well as difficulty in refueling since CNG facilities are not readily available. In this study, running resistance values were obtained by coasting performance tests on actual roads using a Tata Daewoo LF-40 model with three different weight conditions: curb vehicle weight (CVW), half vehicle weight (HVW), and gross vehicle weight (GVW).The test methods include WHVC, NIER-06, and constant-speed driving at 60 km/h. These tests were used to measure the fuel economy of vehicles other than the target vehicles to obtain the combined fuel economy. The energy efficiency was highest in the case of CVW. In the WHVC mode, the fuel consumption rates of HVW and GVW were typically 3.5% and 12% higher than that of CVW, respectively. In constant-speed driving, the fuel efficiency of HVW was higher than that of CVW. Further research is required to analyze the exhaust gas data.

On-line token control of fieldbus for effective data service (효과적 데이터처리를 위한 필드버스의 온라인 토큰제어)

  • 이석원;남부희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.680-683
    • /
    • 1997
  • Fieldbus system should be designed by considering the number of sensors/actors(actuators+ controllers) and their sampling times. But the number of sensors/actors and which are connected to the network bus can be varied by addition and/or fault of the field devices. That variation decreases the efficiency of system which is off-line designed optimally. This paper proposes an algorithm that ensures transmission of cyclic data even though there is the number change in the field devices. We assign the different weight values to cyclic data and acyclic data. By simulation and experiment, the cyclic and acyclic data are processed via the proposed network, and the results are compared with those of the Profibus system. It is shown that the proposed algorithm is more robust with the uncertainties of the field devices of the control system.

  • PDF

Dynamic Characteristic Analysis of SSSC based on Multi-bridge PWM Inverter

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.718-722
    • /
    • 2001
  • This paper proposes an SSSC based on multi-bridge inverters in PWM scheme. The proposed system consists of 6 H-bridge inverter modules per phase. The dynamic characteristic of proposed system was analyzed by simulation with EMTP codes, assuming that the SSSC is inserted in the 154-kV transmission line of one-machine-infinite-bus power system. The feasibility of hardware implementation was verified through experimental works with a scaled-model. The proposed system can be directly inserted in the transmission line without coupling transformers, and has flexibility in expanding the operation voltage by increasing the number of H-bridges.

  • PDF

A Study of Payload Interface Unit Design for COMS (Communication Ocean & Meteorological Satellites) (통신해양기상위성의 탑재체 접속장치 설계에 관한 연구)

  • Cho, Young-Ho;Won, Joo-Ho;Choi, Jae-Dong;Yang, Koon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.369-370
    • /
    • 2008
  • The Payload Interface Unit (PIU) provides the interface between payload equipment (GOCI, MODCS and Ka Band P/L) and the SCU. The PIU is a MIL-STD-1553-Bus Remote Terminal (RT). The MPIU distributes commands to, acquires telemetry from and takes part in the thermal control of the payload equipment. When in ON mode, the PIU is completely observable and can be used for payload control. When in OFF mode, the PIU is non active except the thermal control electronics.

  • PDF

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.