고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화 (A study on the effect on indoor air quality by ventilation system operation in buses)

  • 안선민;이정섭;심인근;김호현
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.

차량용 공조시스템의 현황 및 고속버스의 실내 공기 환경 측정 (The Assessing the HVAC system and Measurements of Indoor Air Quality of Highway Bus)

  • 유호천;노경환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2009
  • The current focus of domestic car industry is moving from technological development to reducing greenhouse gas. This study investigates and measures the HVAC system and indoor air condition of highway buses, which is conducted to develop a HVAC system using natural energy in the future. The measurements show that thermal balance is not fulfilled because heating sources are randomly placed, and relative humidity is in the 20 percent range both in HVAC and non-HVAC systems, which is far below 40%, or the highest thermal comfort level. CO2 concentration was found to be an average of 1500 ppm, but not more than 2522 ppm with 15 persons on board, and with 29 persons on board, an average of 2053 ppm, but not more than 3066 ppm, both of which far exceed allowed CO2 concentration level, or 1000 ppm. Generally, highway buses drop by rest stops and open doors for 15 to 20 minutes for getting in fresh air. But its air improvement effect is temporary, and it exacerbates indoor air condition.

  • PDF

다중이용시설의 위생상태에 관한 조사연구 (A Study on the Sanitation Condition of Public Facility)

  • 김종오;정용택
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.47-55
    • /
    • 2009
  • Indoor air Quality in public facility same as bus terminal and subway station is very important for civil health. The purpose of this study was to investigate the concentration and distribution of PM10 and falling microorganism at the 5 subway stations and bus terminals from Summer 2003 to Summer 2005 in Kyunggi Province. The results were as follows. 1. The highest concentration of PM10 was $187ug/m^3$ at Bucheon Bus Terminal in 2005 while the lowest concentration of PM10 was $78ug/m^3$ at Suwon Bus Terminal in 2003. The year variation of PM10 concentration at the bus terminals in Kyunggi Province was in order of 2005 > 2004 > 2003. The average concentration of PM10 at the five Bus Terminal was $127ug/m^3$. 2. The highest concentration of PM10 was $225ug/m^3$ at Euijungbu Station l in 2004 while the lowest concentration of PM10 was $115ug/m^3$ at Suwon Station in 2003. The year variation of PM10 at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003. The average concentration of PM10 at the five subway stations was $164ug/m^3$. 3. The average amount of falling microoganism at the five bus terminal in Kyunggi Provinc was 201CFU/plate. The minimum is 124 CFU/plate at Seongnam Bus Terminal in 2004 while the maximum is 268CFU/plate at Euijungbu Bus Terminal in summer 2005. The higher concentration of PM10 was 206CFU/plate in 2004 than 199CFU/plate in 2003 and 2005. 4. The minimum is 107CFU/plate at Anyang station in 2003 while the maximum was 263CFU/plate at Euijungbu station in 2003. The average amount of falling microoganism at the five subway stations in Kyunggi Province was 179 CFU/plate. The year variation of falling microorganism at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003.