• 제목/요약/키워드: Burst Test

검색결과 198건 처리시간 0.028초

Burst capacity of pipe under corrosion defects and repaired with thermosetting liner

  • Akram, Ali;Mustaffa, Zahiraniza;Albarody, Thar M. Badri
    • Steel and Composite Structures
    • /
    • 제35권2호
    • /
    • pp.171-186
    • /
    • 2020
  • This paper aims at providing insights on the use of thermosetting liner for the repair of offshore pipelines exposed to corrosion and leakage. The work which covers both experimental and numerical approaches were aspired due to the high cost of repair for pipelines, limitations of thermoplastic material and limited study of reinforced thermosetting liner. The experiment involves a destruction test called the burst test, carried out on an API 5L X42 carbon steel pipe under four case studies, namely (i) intact pipe, (ii) pipe with corrosion defect, (iii) pipe with corrosion defect and repaired with thermosetting liner and (iv) pipe with leakage and repaired with thermosetting liner. The numerical simulation was developed to first validate the experimental results and later to optimize the design of the thermosetting liner in terms of the number of layers required to restore the original strength of the pipe. The burst test shows an improvement in 23% of the burst capacity for the pipe with corrosion defects, after being repaired with a three-layer thermosetting liner. The parametric studies conducted showed that with an addition of thermosetting layers, the burst capacity improves by an average of 1.85 MPa. In conclusions, the improvement in strength can be further increased with increasing thickness of the thermosetting liner. The thermosetting liner was also determined to fail first inside the host pipe.

원전 배관 손상압력 평가를 위한 파열시험 및 유한요소해석 (Burst Test and Finite Element Analysis for Failure Pressure Evaluation of Nuclear Power Plant Pipes)

  • 윤민수;김성환;김태순
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.144-149
    • /
    • 2015
  • This study aims to quantitatively evaluate failure pressure of wall-thinned elbow under combined load along with internal pressure, by conducting real-scale burst test and finite element analysis together. For quantitative evaluation, failure pressure data was extracted from the real-scale burst test first, and then finite element analysis was carried out to compare with the test result. For the test, the wall-thinning defect of the extrados or intrados inside the center of 90-degree elbow was considered and the loading modes to open or close the specimen maintaining a certain load or displacement were applied. Internal pressure was applied until failure occurred. As a result, when the bending load was applied under the load control condition, the intrados of the defect was more affected by failure pressure than the extrados, and the opening mode was more vulnerable to failure pressure than the closing mode. When the bending load was applied under the displacement control, it was hardly affected by failure pressure though it was slightly different from the defect position. The result of the finite element analysis showed a similar aspect with the test. Moreover, when major factors such as material properties and pipeline thickness were calibrated to accurate values, the analytical results was more similar to the test results.

증기발생기 축방향 부분관통균열 전열관의 파열 압력 시험 (Burst pressure tests of axial part-through-wall steam generator tubes)

  • 이국희;김홍덕;강용석;남민우;조남철
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.56-63
    • /
    • 2014
  • In this research, burst tests for axial notched steam generator tubes were conducted. To measure the burst pressure of notched tubes, a burst testing system was manufactured. The tests were conducted under internal pressure at room temperature. Part-through-wall and through-wall notches which have various geometries with different depths and lengths were machined by electro-discharged-machined(EDM) method. The burst pressure decreased exponentially with increasing notch length and decreased almost linearly with increasing notch depth. A comparison of the burst pressure with existing burst pressure solutions for cracked tube show that the existing solution agree well with the test results.

실제크기 배관의 파열시험을 통한 가스배관의 파괴거동 평가 (The Evaluation of Remaining Strength for Corroded Pipeline by Full Scale Burst Test)

  • 김영표;백종현;김우식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.339-344
    • /
    • 2001
  • The transmission pipeline industry spends many millions of dollars annually performing inline inspections, excavating sites of possible corrosion, and repairing or replacing damaged sections of pipe. New criteria for evaluation the integrity of corroded pipe have been developed in recent years to help in controlling these costs. These new criteria vary widely in their estimates of integrity and the most appropriate criterion for a given pipeline is not always clear. This paper presents an overview, comparison and evaluation of acceptability criteria for corrosion defects in pipelines. By full scale burst tests, this paper have assessed the relative accuracy of each of theses criteria in predicting failure and remaining strength. Many of the criteria appear to be excessively conservative and indicate that defects must be repaired when none is needed, based upon burst test data.

  • PDF

Analytical criteria for fuel fragmentation and burst FGR during a LOCA

  • Khvostov, G.
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2402-2409
    • /
    • 2020
  • Analytical criteria for the onset of fuel fragmentation and Burst Fission Gas Release in fuel rods with ballooned claddings are formulated. On that basis, the GRSW-A model integrated with a fuel behaviour code is updated. After modification, the updated code is successfully applied to simulation of the Halden LOCA test IFA-650.12. Specifically, the calculation with Burst Fission Gas Release during the test resulted in prediction of cladding failure, whereas it could not be predicted at the test planning, before new models were implemented. A good agreement of the current model with experimental data for transient Fission Gas Release in the tests IFA-650.12 and IFA-650.14 is shown, as well.

필라멘트 와인딩으로 제작된 킥모터 연소관의 파열 성능 시험 (Burst Performance Test of Filament Wound Kick Motor Case)

  • 이무근;길경섭;조인현;박재성;김중석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.183-186
    • /
    • 2008
  • 필라멘트 와인딩으로 제작된 고체 모터 연소관의 파열특성을 확인하기 위한 해석 및 수압시험을 수행하였다. 본 연소관의 파손 요구조건으로서 운용 중 최대 예상압력(MEOP)의 1.5배 이상의 압력에서 실린더 파손이 일어나야함을 제시하였다. 해석 결과 연소관 내부의 압력이 2088psig 일 때 실린더 파손이 일어나는 것으로 나타났으며 수압시험을 수행하여 2200psig 수준에서 실린더가 파열됨을 검증하였다. 두 결과를 통하여 파열 요구조건을 만족하는 것을 알 수 있다.

  • PDF

Measurement Technique for Sea Height of Burst Using Image Recognition

  • Park, Ju-Ho;Hong, Sung-Soo;Kang, Kyu-Chang;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제2권1호
    • /
    • pp.76-83
    • /
    • 2000
  • A measurement technique of a sea height of burst is introduced for a proximate test using the image recognition of video cameras. In the burst of fuse on the ocean, the burst center of fuse, the sea surface level and the height of calibration poles are measured by the process of image obtained from cameras. Finally, the height of burst of fuse can be computed by Hough transform algorithm. The error compensation algorithms are proposed to eliminate the errors caused by camera level and environmental parameters. As a result of experiment, it has been proved that the proposed measurement system shows the recognition of the center point of the burst image with ${\pm}$0.5m error.

  • PDF

Deep neural network based prediction of burst parameters for Zircaloy-4 fuel cladding during loss-of-coolant accident

  • Suman, Siddharth
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2565-2571
    • /
    • 2020
  • Background: Understanding the behaviour of nuclear fuel claddings by conducting burst test on single cladding tube under simulated loss-of-coolant accident conditions and developing theoretical cum empirical predictive computer codes have been the focus of several investigations. The developed burst criterion (a) assumes symmetrical deformation of cladding tube in contrast to experimental observation (b) interpolates the properties of Zircaloy-4 cladding in mixed α+β phase (c) does not account for azimuthal temperature variations. In order to overcome all these drawbacks of burst criterion, it is reasoned that artificial intelligence technique may be a better option to predict the burst parameters. Methods: Artificial neural network models based on feedforward backpropagation algorithm with logsig transfer function are developed. Results: Neural network architecture of 2-4-4-3, that is model with two hidden layers having four nodes in each layer is found to be the most suitable. The mean, maximum, and minimum prediction errors for this optimised model are 0.82%, 19.62%, and 0.004%, respectively. Conclusion: The burst stress, burst temperature, and burst strain obtained from burst criterion have average deviation of 19%, 12%, and 53% respectively whereas the developed neural network model predicted these parameters with average deviation of 6%, 2%, and 8%, respectively.

도시가스용 D3507 및 D3631 강관의 파괴특성 (Fracture Characteristics of D 3507 and D 3631 City Gas Steel Pipes)

  • 박재학;김한국;신규인;김만원
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 2001
  • It is noted that KS D 3507 pipe steel has several problems when it is used as a city gas pipe at medium pressure. So new pipe steel, KS D 3631, was developed in order to be used as a pipe for medium and low pressure and now it is being substituted for D 3507. In this study, several mechanical tests, such as tensile test, microhardness test, and Charpy impact test were conducted to get material properties of D 3507 and D 3631 pipe steels. And also microstructures at the weld and heat affected zones were observed for the two materials. From the Charpy test results $K_{IC}/$ was estimated for the upper and lower shelf and the critical crack length is calculated for supposed axial semi-elliptical surface cracks. And the burst pressure is estimated as a function of wear depth for a defective D 3631 pipe by using the finite element method. The burst pressure is also calculated for pipes with an axial crack by using the published equations.

  • PDF

원통형 복합재료 압력 용기의 기계적 물성 평가를 위한 세그먼트 형 링 버스트 시험 방법 분석 (Analysis of the Segment-type Ring Burst Test Method for the Mechanical Property Evaluation of Cylindrical Composite Pressure Vessel)

  • 김외태;김성수
    • Composites Research
    • /
    • 제34권4호
    • /
    • pp.257-263
    • /
    • 2021
  • 복합재료는 높은 비 강성 및 비 강도 특성으로 인해 기체 혹은 액체 연료를 저장하기 위한 압력 용기의 설계 및 제작에 널리 활용되고 있다. 이에 따라, 압력용기의 파열압력 또는 파단 변형률의 기계적 특성의 보다 정확한 측정은 상용화 전에 필수적 요소이다. 그러나, 기존의 시험방법을 활용한 복합재료 압력 용기의 안전성 검증은 하중 전달 매체의 변형으로 인한 추가적인 에너지 손실의 발생과, 불필요한 하중 및 모멘트의 발생 등의 한계가 있다. 따라서 본 연구에서는 수직기둥의 이론적인 하중전달 정도와 적용 가능한 수직방향 변위를 고려하여 세그먼트형 링 버스트 시험장치를 설계하였다. 또한, 세그먼트 형 링 버스트 시험장치의 균일한 압력분포를 검증하기 위해 수치해석을 활용하였고, 수압 시험방법과 링 시편의 원주방향 응력 및 변형률 분포를 비교하였다. 복합재료 압력용기의 파괴 거동을 모사하기 위해 Hashin 파손 기준을 적용하였고, 실험적으로 파단 변형률을 측정하여 이를 수치해석 결과와 비교하였다.