• Title/Summary/Keyword: Buoyancy Flux

Search Result 59, Processing Time 0.025 seconds

A Study of Heat Transfer and Particle Deposition During Outside Vapor Deposition Process (외부증착(OVD)공정에 관한 열전달과 입자부착에 관한 연구)

  • 송영휘;최만수;강신형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.193-202
    • /
    • 1994
  • A study of heat transfer and particle deposition has been made numerically for outside vapor deposition process. Heat conduction through the two layer cylinder which consists of the target and the deposited layer is included together with heat transfer and gas jet flow onto the cylinder from the torch. Temperature and flow fields have been obtained by an iterative method and thermophoretic particle deposition has been studied. Of particlar interests are effects of the thickness of the deposited layer, the torch speed and the rotation speed of the cylinder on particle deposition flux and efficiency. Effects of buoyancy, variable properties and tube rotation are included.

Melting Heat Transfer of Liquid Ice in a Rectangular Vessel with Heated Top Wall (구형용기내 상부면가열에 의한 유동빙의 융해열전달)

  • 김명환;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.36-44
    • /
    • 1995
  • Melting characteristics of unrestrained liquid ice in a rectangular vessel with heated top wall were investigated experimentally. The liquid ice, a mixture of ice particles and ethylene-glycol aqueous solution, was adopted as a testing material. During the melting process the liquid ice was drawn by buoyancy to the heated top wall of the rectangular vessel where close-contact melting occured. The melting behavior and melting rate of the liquid ice as well as local/mean heat-transfer coefficient at the heated top wall were observed and measured under a variety of conditions of heat flux and various initial concentration of the aqueous binary solution. It was found that the heat transfer of the heated top wall is remarkably promoted by the close-contact melting, and that the dendritic frozen layer at the lower interface of the liquid ice is formed. Photographic evidence demonstrated that plumes containing solute-rich liquid issued from isolated chimneys within the liquid ice layer where segregation of interstitial channel took place.

  • PDF

A Numerical Study of Smoke Movement in Atrium Fires with Ceiling Hea Flux (천장에 열 유속을 갖는 대형 공간에서 화재 발생시 연기거동에 대한 수치해석적 연구)

  • 정진용;유홍선;김성찬;김충익
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.20-29
    • /
    • 1999
  • This paper describes the smoke filling process of a fire field model based on a self-developed SMEP(Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k- epsilon turbulence model with buoyancy term. Compressibility is assumed and the perfect gas law is used. The results of the calculated upper-layer average temperature and smoke layer interface height has shown reasonable agreement compared with the zone models. The zone models used are the CFAST developed at the Building and Fire Research Laboratory NIST U.S.A. and the NBTC one-room of FIRECALC developed at CSIRO, Australia. The smoke layer interface heights that are important in fire safety were not as sensitive as the smoke layer temperature to the nature of ceiling heat flux condition.

  • PDF

Case Study on the Mixed Layer Development using the UHF Radio Sounding (고도별 UHF 원격 관측을 이용한 혼합층 발달 사례 분석)

  • Kim, Sang-Jin;Kwon, Byung Hyuk;Kim, Kwang-Ho;Kim, Park Sa;Kim, Min-Seong;Jo, Won Gi;Yoon, Hong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.253-264
    • /
    • 2018
  • The GPS radiosonde is designed to conduct a full synoptic sounding to balloon burst using data generated from precision meteorological sensors and the GPS satellite network. The GPS radiosonde include proven, accurate temperature, humidity and capacitance aneroid pressure sensors. The atmospheric boundary layer was intensively observed in three islands of the west sea from 18 LST on March 9, 2016 to 06 LST on March 12, 2016. We investigated the restriction of nocturnal stable layer and rather the development of the mixed layer at night. On March 9, nocturnal mixed layer was developed by buoyancy heat flux. On the other hand, on March 10, the shear production was higher especially at 21 LST when the mixed layer height was the highest during the intensive observation period. The wind shear and the surface heat flux which produce the turbulent kinetic energy played an important role to grow the mixed layer even at night.

Flow of MHD Powell-Eyring nanofluid: Heat absorption and Cattaneo-Christov heat flux model

  • Sharif, Humaira;Khadimallah, Mohamed A.;Naeem, Muhammad Nawaz;Hussain, Muzamal;Hussain, Sajjad;Tounsi, Abdelouahed
    • Advances in nano research
    • /
    • v.10 no.3
    • /
    • pp.221-234
    • /
    • 2021
  • During the previous few years, phenomenon of bioconvection along with the use of nanoparticles showed large number of applications in technological and industrial field. This paper analyzed the bioconvection phenomenon in magnetohydrodynamic boundary layer flow of a Powell-Eyring nanoliquid past a stretchable cylinder with Cattaneo-Christov heat flux. In addition, the impacts of chemical reaction and heat generation/absorption parameter are considered. By the use of appropriate transformation, the governing PDEs (nonlinear) have been transformed and formulated into nonlinear ODEs. The resulting nonlinear ODEs subjected to relevant boundary conditions are solved analytically through homotopy analysis method which is programmed in Mathematica software. Graphical and numerical results versus physical quantities like velocity, temperature, concentration and motile microorganism are investigated under the impact of physical parameters. It is noted that velocity profile enhances as the curvature parameter A and Eyring-Powell fluid parameter M increases but a decline manner for large values of buoyancy ratio parameter Nr and bio-convection Rayleigh number Rb. In the presence of Prandtl number Pr, Eyring-Powell fluid parameter M and heat absorption parameter ��, temperature profile decreases. Nano particle concentration profile increases for increasing values of magnetic parameter Ha and thermophoresis parameter Nt. The motile density profile has revealed a decrement pattern for higher values of bio-convection Lewis number Lb and bio-convection peclet number Pe. This study may find uses in bio-nano coolant systems, advance nanomechanical bio-convection energy conversion equipment's, etc.

An experimental study on instability and control of co-flow diffusion flames (동축류 확산화염의 불안정성과 제어에 관한 실험적 연구)

  • Lee, Hyeon-Ho;Hwang, Jun-Yeong;Jeong, Seok-Ho;Lee, Won-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.153-164
    • /
    • 1997
  • Flame oscillation phenomena in a co-flow diffusion flame was experimentally studied with periodic fuel supply using a solenoid valve. The degree of excitation was controlled by changing the volume flux of fuel passing through the valve. Flame oscillation frequencies were measured utilizing a photodiode, a spectrum analyzer, video and high speed movies. Laser planar visualization was employed to study the correlation between the flame oscillation and the toroidal vortices. Observed are three regimes of flame oscillation, where the oscillation frequencies are for the multiples of excitation, the excitation itself and the flame natural oscillation. Both periods of natural oscillation and of excitation induced oscillation exist over one cycle of the excitation in the frequency multiplied regime. It is considered as an effect of balancing the influence of buoyancy driven vortex with that of excitation induced vortex near the excitation rate of 0.2. Flame shapes are become monotonous as increasing the excitation frequency to the range of over two fold of the natural oscillation. The flame oscillation can be modulated to the frequency of either multiples of excitation or excitation itself under certain conditions. This implies that the flame oscillation could be modulated to avoid the resonance frequency of the combustor, and shows the possibility of active control of the flame oscillation.

The Effect of Thermal Buoyancy on Air Flow and Temperature Distribution in a Slot-Ventilated Livestock Building (환기중(換氣中)인 축사(畜舍)의 열부력(熱浮力)이 공기유동 및 온도분포에 미치는 영향)

  • Choi, H.L.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.2
    • /
    • pp.144-157
    • /
    • 1993
  • 환기중인 실험축사내에서 가축의 현열과 환기공기의 온도차에 의한 열부력(熱浮力)(thermal buoyancy)이 공기유동 및 온도분포에 미치는 영향을 구명(究明)하기 위하여 TEACH 컴퓨터프로그램($k-{\varepsilon}$ 난류모형 및 SIMPLE계열 Algorithm)을 Curvilinear Coordinates에 맞게 변형하였다. 계산한 축사내 공기유통 및 온도분포의 유의성(有意性) 검증은 Boon(1978)의 실험결과를 이용하였다. 열부력의 크기에 따른 유동의 변화를 관찰하기 위하여 유입공기의 온도를 $17^{\circ}C$$10^{\circ}C$ 두 수준으로 입력하였으며, 가축의 현열플릭스(flux)는 실내온도에 따라 변화하므로 유압공기의 온도가 $17^{\circ}C$일 때는 130W/$m^2$, $10^{\circ}C$일 때는 170W/$m^2$을 경계조건으로 입력하였다. 예측한 공기유동의 형태는 실험값(Boon, 1978)과 비교하여 대체로 만족할만한 결과를 얻었다. 그러나 유입공기의 온도가 $10^{\circ}C$인 경우, 예측 공기유동은 실험 유동형태와 차이가 있었다. 즉, 실험에서는 수평슬롯으로 유입된 공기가 바로 아래로 굴절되어 유동(流動)하였으나, 계산의 결과는 일정 거리로 수평방향으로 유동하다가 아래로 굴절하였다. 이런 유동의 차이는 경험적으로 열부력(熱浮力)에 민감하게 반응하지 않는 k-${\varepsilon}$ 난류(亂流)모형의 적용이 원인이 되거나 실험의 부적절한 수행이 원인이 될 수도 있다. 이 유동(流動)의 Reynolds 수(數) (Re)는 약 3,300, 수정Ar수(修正Ar數)(Corrected Archimedes Number : $Ar_c$)64로써, $Ar_c$ <30 이거나 $Ar_c$ >75이면 유입공기의 제트는 수평유동한다는 Randall & Battams(1979)의 연구결과와는 일치하였다. 그러나 공기제트의 굴절은 유동의 특성이 같다하더라도 유체의 성질, 축사의 기하학적 형태에 따라서 매우 민감하게 반응하므로 실제 실험을 통한 재검정과정을 거쳐야 할 것으로 판단된다. Fig. 9와 Fig. 10의 기하학적 형태의 지점별 예측온도와 측정온도(Boon, 1978)와의 편차는 대부분의 지점에서는 $1^{\circ}C$ 미만으로 상당히 정확하였으며, 최대의 온도차는 Fig. 10의 지점 13에서 $1.7^{\circ}C$이었다.

  • PDF

A Comparative Study of 2-Dimensional Turbulence Models for Thermal Discharge (2차원 온배수 난류모형의 비교연구)

  • Choi, Hung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.3
    • /
    • pp.225-235
    • /
    • 1999
  • For a comparative evaluation of three turbulence models in the analyses of thermal discharge behavior into a crossflow, a 2-dimemsional near-field numerical model is developed. The selected models are k-$\varepsilon$ and k-ι turbulence models as a 2-equation turbulence model and a 4-equation turbulence model in which the transport equations for mean of the temperature fluctuation squared and its dissipation rate for the consideration of buoyancy production and turbulent heat flux terms are added to a k-$\varepsilon$ turbulence model. The developed models are applied to a steady flow in an open channel with simple geometry and the numerical results agree with the existing experimental data. Numerical results of buoyancy induced gravitational lateral spreading by 4-equation turbulence model agree with the experimental data better than those of 2-quation turbulence models. The flow patterns by 4 and 2-equation turbulence models are similar.

  • PDF

Unsteady laminar boundary layer over a heated circular cylinder started impulsively from rest (갑자기 출발하는 가열된 원통 주위의 비정상 충류경계층 유동에 관한 수치적 연구)

  • 김재수;장근식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.262-270
    • /
    • 1987
  • A numerical method is presented which can solve the unsteady momentum and thermal boundary layers, coupled through the agency of buoyancy force, over a heated circular cylinder impulsively started from rest. By linearizing the nonlinear finite difference equations without sacrificing accuracy, numerical solutions are obtained at each time step without iteration. To get rid of the requirement of excessive number of grid points in the region of reversed flow, special form of transformed variables are used, by which the computational boundary layer thickness is maintained almost constant. These numerical properties enable the method to easily handle the region of reversed flow and how the singularity develops in the interior of the boundary layer. In order to investigated the thermal effects on the skin friction, heat flux, displacement thickness and on the separation, we have successfully solved three different cases of the buoyancy parameter .alpha.(Gr/Re$^{2}$).

A Comparison of Various Governing Parameters on Hydrodynamic Stability in Interface on Small Solar Pond (소형태양수구내(小型太陽水構內) 중간경계면(中間境界面)에서 수력학적(水力學的) 안정(安定)에 관(關)한 각종(各種) 지배변수(支配變數)의 비교(比較))

  • Park, Ee-Dong
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.11-19
    • /
    • 1985
  • In this paper, the interface stability not to occur mixing and entrainment between the adjacent layers has been studied in the case of the selective withdrawal of a stratum and the injection in stratified fluid formed by the density difference in a small solar pond. There are stability parameter, Richardson number, Rayleigh number and Froude number as the parameters governing stability in order to measure the interface stability on the stratified fluid. The model which could measure the interface stability on the stratified fluid was the small solar pond composed by 1 meters wide, 2 meters high, and 5 meters long. In order to measure the interface stability on the stratified fluid at the inlet port, the middle section and the outlet port, Richardson number, Rayleigh number, and Froude number involved in the parameters governing the stability were calculated by means of the data resulted from the test of the study on hydrodynamic stability between the convective and nonconvective layers in that solar pond. Richardson number written by the ratio of inertia force to buoyancy force can be used in order to measure the stability on the stratified fluid related to the buoyancy force generated from the injection of fluid. Rayleigh number written by the product of Grashof number by Prandtl number can be used in order to measure the stability of the fluid related to the heat flux and diffusivity of viscosity. Froude number written by the ratio of gravity force to inertia force can be used in order to measure the stability of the nonhomogeneous fluid related to the density difference. As the result of calculating the parameters governing stability, the interface stability on the stratified fluid couldn't be identified below the 70cm height from the bottom of the solar pond, but it could be identified above the 70cm height from it at the inlet port, the middle section and the outlet port. When compared with such the three parameters as Richardson number, Rayleigh number, Froude number, the calculated result was in accord with them at inlet port, the middle section and the outlet port. Henceforth, it is learned that even though any of the three parameters is used for the purpose of measuring the interface stability on the stratified fluid, the result will be the same with them. It is concluded that all the use of Richardson number, Rayleigh number, and Froude number, is desirable and infallible to measure the interface stability on the stratified fluid in the case of considering the exist of the fluid flow and the heat flux like the model of the solar pond.

  • PDF