• Title/Summary/Keyword: Bulking Sludge

Search Result 50, Processing Time 0.025 seconds

Effect of Oyster Shell Addition on the Dissolved Air Flotation and Sedimentation of Bulking Sludge (팽화슬러지의 용존공기부상과 침전에 미치는 굴패각 첨가의 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.82-88
    • /
    • 2007
  • The objective of this study is to examine the effect of the waste oyster shell powder as the addition agent in bulking sludge thickening of paper manufacturing plant using DAF(Dissolved Air Flotation) and gravitational sedimentation. The effect of parameters such as dosage and size distribution of oyster shell were examined. The results showed that the optimum dosage of mixed oyster shell(size range : $\sim250{\mu}m$) was 0.8 g/L. The oyster shell addition of 5.0 g/L in sedimentation process was increased thickening concentration of 3.25 times. When 5.0 g/L of oyster shell was added in DAF process, water content of sludge was decreased from 95.5% to 82.7% in dewatering process using Buchner funnel test device. When size of oyster shell was divided four ranges($\sim53{\mu}m$, $53\sim106{\mu}m$, $106\sim150{\mu}m$, $150\sim250{\mu}m$), optimum size range for the flotation and dewatering was $53\sim106{\mu}m$.

Effects of Raw Materials and Bulking Agents on the Thermophilic Composting Process

  • Tang, Jing-Chun;Zhou, Qixing;Katayama, Arata
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.5
    • /
    • pp.925-934
    • /
    • 2010
  • Three typical biological solid wastes, namely, animal manure, garbage, and sewage sludge, were compared with regard to the composting process and the changes in microbial community structure. The effects of different bulking agents such as rice straw, vermiculite, sawdust, and waste paper were compared in manure compost. The differences in the microbial community were characterized by the quinone profile method. The highest mass reduction was found in garbage composting (56.8%), compared with manure and sludge (25% and 20.2%, respectively). A quinone content of $305.2\;{\mu}mol/kg$ was observed in the late stage of garbage composting, although the diversity index of the quinone profile was 9.7, lower than that in manure composting. The predominant quinone species was found to be MK-7, which corresponds to Gram-positive bacteria with a low G+C content, such as Bacillus. The predominance of MK-7 was especially found in the garbage and sludge composting process, and the increase in quinones with partially saturated long side-chains was shown in the late composting process of manure, which corresponded to the proliferation of Actinobacteria. The effects of different bulking agents on the composting process was much smaller than the effects of different raw materials. High organic matter content in the raw materials resulted in a higher microbial biomass and activity, which was connected to the high mass reduction rate.

Effect of Nutrient Composition and Air Regulation on Bulking in the Activated Sludge Process (활성오니공법에서 영양염류 조성비와 공기조절이 팽화발생에 미치는 영향)

  • 이장훈;권혁구;강병곤;정준오
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.7-14
    • /
    • 2004
  • The change in filamentous bacteria appearance was observed by adjusting factors such as organic and nurient concentration of feed wastewater and the aeration rate in the reactor. In case that COD:N:P and DO were 100:10:1 and 6.1 m1/1 respectively, the mean SVI was 122 ml/g and the filaments were developed normally in flocs. For the low DO con- dition, however, the SVI averaged 186 ml/g and the appearance of outgrowing filaments were more frequent. When the high organic was supplied into the reactor, the average SVI was 274 ml/g and the distinct filamentous bulking was observed. Meanwhile when COD:N:P was maintained at 100: 1 :0.5, the SVI was as low as 87 ml/g and the appearance of filaments were minimal and the size of flocs was small comparing other experimental conditions. For normal, low aeration and high organic concentration, predominant filaments in the early stage of experiments were commonly Type 021N,S. natans which were usually found in low DO condition. However, Type 041, Type 1851, Type 0961 became predominant as experiments extended. Meanwhile, in low nutrient condition, Type 0675, Type 1851, and Type 0961 were observed. The filamentous bacteria appearance for SVI< 150(ml/g), Type 0041, Type 0961 (usually low organic in feed wastewater) were predominantly observed and SVI > 150(ml/g), S. natans and Type 021N(usually low DO in aeration basin) was predominant.

Efficient Treatment of Sewage Sludge by Effective Microorganisms (유효미생물에 의한 하수슬러지의 효율적 처리)

  • Choi, Chung-Sig;Joo, Gil-Jae;Lee, Dong-Hoon;Choi, Choong-Lyeal;Rhee, In-Koo;Choi, Jyung
    • Current Research on Agriculture and Life Sciences
    • /
    • v.17
    • /
    • pp.45-52
    • /
    • 1999
  • This study was conducted to evaluate the effects of microbial inoculation on sewage sludge composting. The number and species of microorganisms in sewage sludge sampled on February were higher than those sampled on August. The composting of sewage sludge is inhibited by the polyacrylamide cation, which was used as a coagulant and known to repress the growth of microorganisms. The growth of all microorganisms was inhibited by the addition of the polyacrylamide cation at a concentration of more than 0.8%. The species and viable counts of microorganisms were observed to increase during composting sewage sludge by inoculation of the effective microorganisms and addition of the pine tree sawdust as a bulking agent, compared with those without inoculation. A variety of organisms in compost(sewage sludge plus sawdust) were observed after composting for 30 days, such as Fragilaria sp., Proales sp., Vorticella sp., Schizothrix sp., Anabaena sp., Zoothaminium sp., Epstylis sp., Arcella sp., Balantidium sp., Actinophrys sp., Synedra sp., Euglypha sp., Ulothrix sp., Anacystis sp., and Clostium sp.

  • PDF

Improvement of the Thickening Characteristics of Activated Sludge by Electroflotation (EF) (전해부상을 이용한 활성슬러지의 농축효율 향상)

  • Choi, Young Gyun;Chung, Tai Hak;Yeom, Ick Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.295-300
    • /
    • 2005
  • The performances of electroflotation (EF) on the thickening of activated sludge were investigated using laboratory scale batch flotation reactors. Four activated sludges including bulking sludges were tested. After 30minutes of EF operation, 57-84 % of sludge volume reduction could be achieved by EF, while only about 1.5-14% could be obtained by gravity thickening for the same period. After thickening the effluent water quality in terms of TCOD, SS, and turbidity was improved by EF operation for all sludge samples. It is induced that the air bubbles entrapped in the thickened sludge play a key role in the observed improvement of sludge thickening and effluent quality.

Study on Optimum Conditions for the Composting of Industrial Wastewater Sludge (공단 폐수 슬러지의 퇴비화 최적조건)

  • Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Su
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • To study the optimum conditions of composting with industrial wastewater sludge, the variations of temperature and $CO_2$ generation amount during the composting periods were investigated. The conditions were that industrial wastewater added to bulking agents such as sawdust and rice hull was used, and differently treated with microorganism seeding or not, initial C/N ratios, air flow rate and initial moisture contents, respectively. The results were summarized as follows : Seeding 5% of microorganism was higher the temperature than not seeding. And using sawdust as bulking agents, and adjusting 30~40 of Initial C/N ratio, 200ml/l.min. of k flow rate and 67~68% moisture contents were higher the temperature than any other conditions. Seeding 5% of microorganisms was higher $CO_2$ generation amount than not seeding. And that was much in the order of 7~40, 30~34 and 22~23 of initial C/N ratio. Judging from the results, it should be considered that the optimum conditions in the composting of industrial wastewater sludge were seeding of 5% microorganisms, and adjusting 30~34 of Initial C/N ratio, 200ml/l min. of air flow rate and 67~68% of Intitial moisture contents. The contents of inorganic matters and C/N ratio during the composting periods at optimum condition were a little Increased. and heavy metals contents after composting were lower than standard for fortllizer.

  • PDF

Hydraulic Shock Load Response of Activated Sludge Process (활성슬러지공정의 수리학적 충격부하 반응)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae;Cho, Chul Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.67-78
    • /
    • 1997
  • The objective of study was to examine to transient response of hydraulic shock loading in activated sludge process for treatment of municipal sewage. The general experiment approach was to operate the system under steady-state(pre-shock), then to apply step changes during 24hours in fourfold hydraulic shock loading at the same organic loading. Performance was assessed in both the transient state and the new steady-state(post-shock). Three bench scale activated sludge reactors were operated to investigate the effect of fourfold hydraulic shock loading on TSS and COD removal efficiency. In activated sludge reactors operated with 13hours and 7hours of HRT, effluent quality of all reactors was not changed for few effects, and also showed no foaming and no sludge bulking. Those results are the same as sludge withdrawn reactors. The effect of fourfold hydraulic shock loading on the activated sludge reactors operated with 3hours of HRT was most severe. The effluent quality was deteriorated significantly and generate foaming in reactors. Less than 24hours after the fourfold shock loading applied, the activated sludge system seemed to attain a new steady-state condition as show by effluent.

  • PDF

Study of membrane fouling in the crossflow MBR system (교차흐름 막결합형 생물반응기에서의 막오염 연구)

  • 최중구;김인철;최남석;홍서표;탁태문
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.150-152
    • /
    • 1998
  • Now the lack of water is serious problem all over the world because of the growth of population and expansion of industrial activities. So wastewater recycle and reuse is essential in many countries. One of the most popular wastewater treatment processes is conventional activated sludge system. In spite of significant degree of treatment rate the biological process has some operational difficulties and capital disadvantages. In conventional activated sludge process, sludge settling condition is getting worse in case of sludge bulking, it is common that overall process fails due to wash-out of biomass causing low concentration of MLSS in the aeration tank. Because of the absence of claifier the membrane bioreactor(MBR) process is less affected by such problems.

  • PDF

Construction of Resource Recovery System for Organic Wastes (유기성 폐기물의 자원화 체제구축에 관한 연구)

  • 양재경;최경민
    • Journal of Korea Technology Innovation Society
    • /
    • v.2 no.2
    • /
    • pp.290-308
    • /
    • 1999
  • In this study a system for the treatment or recyling of organic wastes from both urban and rural area was recommended. It was developed based on the resource recovery system regarding human being by four tectnologies; forage, methane production, high-grade composting and complete decomposition. High quality compost can be produced by combining several kind of wastes produced from urban and agricultural areas. High quality compost must possess not only general characteristics of ordinary compost, but also a superior ability to improve the soil properties and must contain more nutrients for plant. Cedar chips were recommended as the main bulking agent to adjust moisture contents and air permeability. Charcoal and zeolite can be used not only as the second bulking agent but also as fertilizer for improve the soil amendment. Complete decomposition of organic wastes is defined by organic matter being completely converted to $CO_2$ and water. All the input water was evaporated by the heat produced through the oxidation of organic matter, In the present study, the complete treatments were successfully achieved for Shochu wastewater, swine wastes, thickened excess sewage sludge, wastes produced by Chinese restaurant and anaerobic digested sludge. First of all, recycling center of organic wastes should be established for the protect the environments and effective recovery of organic resources. This may means the way to derive the recovery of human value.

  • PDF

The Optimum Design of Suspended Growth Systems (부유성 미생물을 이용한 생물처리법의 최적 설계)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1011-1019
    • /
    • 2000
  • The purpose of this study is to examine the basis of design condition of existing treatment processes, namely, Extended Aeration Process, Conventional Activated Process, High Rate Aeration Process and Modified Aeration Process, by clarifying the correlations of influent wastewater concentration, hydraulic retention time, food-to-microorganism ratio and sedimentation of sludge, as well as to ascertain the feasibility of design, regardless of the existing design condition. In particular, this study made a priority investigation of hydraulic retention time and sludge sedimentation, because sludge sedimentation is the main factor$^{1)}$ which determines the operating conditions of existing treatment processes. Therefore, it is generally known that in case exceeds the sphere of design presented for each treatment, sludge bulking may occur. The results of Lesperance's test$^{1)}$, which formed the basis of design, showed the sphere of loading without security of sludge sedimentation, as in Fig. 1. The reason for sludge bulking in a certain condition, as above, is due to failure in application of optimum loading corresponding to each retention time by employing a few operating condition, which proved to be consecutively workable after years of trials and failures by Lesperance, for test conditions. However, the result of this test showed that in case of proper maintenance of loading. sludge sedimentation can be ensured under 120 SVI. Therefore, this study suggested hydraulic retention time and its corresponding optimum loading, and identified the hydraulic retention time as a determinant of sludge sedimentation. And. on the basis of these findings, this study suggested the feasiblity of UHR(Ultra High Rate), a new operating process, exceeding several times the applicable loading value of High Rate Aeration Process under one hour retention time which has not yet applied to the existing treatment processes.

  • PDF