• Title/Summary/Keyword: Bulk-fill composites

Search Result 19, Processing Time 0.025 seconds

Degree of Conversion and Polymerization Shrinkage of Low and High Viscosity Bulk-Fill Giomer-based and Resin-based composites (저점도 및 고점도 Bulk-fill Giomer 복합레진과 Bulk-fill 복합레진의 전환율과 중합수축)

  • Kim, Heera;Lee, Jaesik;Kim, Hyunjung;Kwon, Taeyub;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • The aim of this study was to compare the degree of conversion and polymerization shrinkage of low and high viscosity bulk-fill giomer-based and resin-based composites. Two bulk-fill giomer (Beautifil Bulk Restorative (BBR), Beautifil Bulk Flowable (BBF)), two bulk-fill (Tetric N-Ceram Bulk-fill (TBF), SureFil SDR flow (SDR)) and two conventional resin composites (Tetric N-Ceram (TN), Tetric N-flow (TF)) were selected for this study. The degree of conversion was measured by using Fourier transform infrared spectroscopy. Polymerization shrinkage was measured with the linometer. For all depth, BBR had the lowest degree of conversion and SDR had the highest. At 4 mm, the degree of conversion of low and high viscosity bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). At the depth between 2 mm and 4 mm, there were significant difference with TBF, TN and TF (p < 0.05), while no significant difference in the degree of conversion was measured for BBR, BBF and SDR. Polymerization shrinkage of six resin composites decreased in the following order: TF > SDR > BBF > TBF > TN and BBR (p < 0.05). Polymerization shrinkage of bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). From this study, it is found that the bulk-fill giomer resin composites and TBF were not sufficiently cured in 4 mm depth. The degree of conversion of low and high viscosity bulk-fill giomer resin composites was significantly lower than bulk-fill resin composites in both 2 mm and 4 mm depths. Therefore, such features of bulk-fill giomer resin composites should be carefully considered in clinical application.

Comparison of the Mechanical Properties between Bulk-fill and Conventional Composites (Bulk-fill 복합레진과 전통적 복합레진의 물성비교)

  • Noh, Taehwan;Song, Eunju;Park, Soyoung;Pyo, Aeri;Kwon, Yonghoon;Kim, Jiyeon;Kim, Shin;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.365-373
    • /
    • 2016
  • Composites are the most useful restorative material. However, composites have some disadvantages such as polymerization shrinkage, long working time, and susceptibility to water and contamination, which are stood out more especially when treating children. To solve these problems, bulk-fill composites have been developed. The aim of this study is to compare mechanical properties of bulk-fill and conventional composites. Bulk-fill composites (SureFil SDR flow (SDR), Tetric N-Ceram bulk fill (TBF)) and conventional composites (Filtek Z-350 (Z-350), Unifil Flow (UF), Unifil Loflo Plus (UL)) were used. The Vickers hardness tester was used to measure the microhardness of materials, and Fourier transform infrared spectroscopy was used to measure the degree of conversion. Polymerization shrinkage was measured by using a linometer. Flexural and compressive properties were measured by using the universal testing machine. Data were statistically analyzed by ANOVA and Scheffe's post hoc test. The level of significance was set to p < 0.05. Most conventional composites showed higher microhardness than bulk-fill composites. However, bulk-fill composites showed a higher top/bottom microhardness ratio than conventional composites. Bulk-fill composites showed a higher top/bottom degree of conversion ratio than conventional composites. The polymerization shrinkage was highest in UL and lowest in Z-350. The polymerization shrinkage of flowable composites was higher than that of non flowable composites. The compressive properties were highest in Z-350 and lowest in SDR and UL. In terms of flexural properties, Z-350 was the highest. However, none of the bulk-fill composites exhibited mechanical properties as good as those of conventional composites. Nonetheless, the ratio of microhardness and degree of conversion, which are important properties of bulk filling, were higher in bulk-fill composites. Therefore, the bulk-fill composites might be considered suitable restorative materials in pediatric dentistry.

Color Stability of Bulk-Fill Resin Composites after Immersion in Different Media (다양한 용액에 따른 Bulk-fill 복합레진의 색조안정성 평가)

  • Kang, Sungkyoon;Song, Jihyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.353-361
    • /
    • 2019
  • The aim of this study was to evaluate the color stability of bulk-fill and conventional resin composites with respect to different storage media and thickness of composites. Filtek™ Z250 and Filtek™ Z350XT were evaluated as conventional resin composites. Filtek™ Bulk-fill Posterior Restorative and Tetric® N-Ceram Bulk Fill were evaluated as bulk-fill resin composites. CIE L*a*b* values of baseline were measured after 24 hours of storage in distilled water, and each resin composite group was divided into three subgroups and stored in distilled water, red wine, and coffee media respectively. Again after 1, 7 and 28 days of immersion, color changes (ΔE*) were calculated using the CIE L*a*b* values. The greatest ΔE* was observed in red wine for all resin composites, and the mean color changes were ranked in the increasing order of distilled water, coffee, red wine. Filtek™ Z350XT exhibited the greatest color change in all media, followed by Filtek™ Bulk-fill Posterior Restorative. Filtek™ Z250 and Tetric® N-Ceram Bulk Fill followed with similar mean color change values. According to the 2 different thicknesses of 2 mm and 4 mm of bulk-fill resin composites, there was no thickness-related difference on color changes.

Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites

  • Kim, Eun-Ha;Jung, Kyoung-Hwa;Son, Sung-Ae;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.128-135
    • /
    • 2015
  • Objectives: This study evaluated the effects of the resin thickness on the microhardness and optical properties of bulk-fill resin composites. Materials and Methods: Four bulk-fill (Venus Bulk Fill, Heraeus Kulzer; SDR, Dentsply Caulk; Tetric N-Ceram Bulk Fill, Ivoclar vivadent; SonicFill, Kerr) and two regular resin composites (Charisma flow, Heraeus Kulzer; Tetric N-Ceram, Ivoclar vivadent) were used. Sixty acrylic cylindrical molds were prepared for each thickness (2, 3 and 4 mm). The molds were divided into six groups for resin composites. The microhardness was measured on the top and bottom surfaces, and the colors were measured using Commission Internationale d'Eclairage (CIE) $L^*a^*b^*$ system. Color differences according to the thickness and translucency parameters and the correlations between the microhardness and translucency parameter were analyzed. The microhardness and color differences were analyzed by ANOVA and Scheffe's post hoc test, and a student t-test, respectively. The level of significance was set to ${\alpha}=0.05$. Results: The microhardness decreased with increasing resin thickness. The bulk-fill resin composites showed a bottom/top hardness ratio of almost 80% or more in 4 mm thick specimens. The highest translucency parameter was observed in Venus Bulk Fill. All resin composites used in this study except for Venus Bulk Fill showed linear correlations between the microhardness and translucency parameter according to the thickness. Conclusions: Within the limitations of this study, the bulk-fill resin composites used in this study can be placed and cured properly in the 4 mm bulk.

Evaluation of Cavity Wall Adaptation of Bulk-fill Resin Composites in Class II Cavities of Primary Molar (유구치 2급 와동에서 bulk-fill 복합레진의 와동적합성 평가)

  • Bae, Youngeun;Shin, Jonghyun;Kim, Shin;Jeong, Taesung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.446-454
    • /
    • 2017
  • Recently, there have been many studies on bulk-fill resin composites. However, studies on the proper materials for pediatric patients are rare. The aim of this study was to compare the cavity wall adaptation of bulk-fill resin composites with conventional resin composite in class II cavities of primary molars using microcomputed tomography (micro-CT). Standardized class II slot cavities were prepared in 80 exfoliated primary molars and randomly divided into 4 groups. The control group was restored with conventional resin composite, Filtek Z-350 XT (FZ), and the three groups were restored with bulk-fill resin composites, Filtek bulk-fill posterior (FB), Tetric N-Ceram Bulk Fill (TNC), Filtek bulk-fill flowable (FBF). All specimens were thermocycled and then immersed in 50% silver nitrate ($AgNO_3$) solution. Micro-CT was used to measure the penetration volume of the total silver nitrate and the degree of cervical marginal leakage and the number, size, and position of the voids were evaluated. The results revealed that the volume of silver nitrate were significantly different between FB and FZ (p < 0.05). The results also revealed that the penetration length of silver nitrate FBF showed statistically lower than the FZ and FB (p < 0.05). There was no significant difference between the groups in number and size of voids. In conventional resin composite, most of the voids were present inside the restoration (83.3%), but the voids in the bulk-fill resin composites incidence were higher in the gingivoaxial angle. The cavity wall adaptation demonstrated in class II restorations of primary molar by new bulk fill resin composites was similar to conventional incremental technique. Bulk-fill resin composites might be an clinical option for a faster restoration in deciduous teeth.

Evaluation of Shear Bond Strength and Microleakage of Bulk-fill Resin Composites (Bulk-fill 복합레진의 상아질 전단결합강도 및 미세누출)

  • Lee, Hanbyeol;Seo, Hyunwoo;Lee, Juhyun;Park, Howon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.4
    • /
    • pp.281-290
    • /
    • 2015
  • The aim of this study was to evaluate shear bond strength (SBS) of bulk-fill resin composites (RCs) to dentin and their micro-leakage. One high-viscosity bulk-fill RC and 2 low-viscosity bulk-fill RCs were compared with 1 conventional RC. 7thgenerationbondingagentswereused. In order to evaluate SBS values, 40 permanent molars were selected and divided into 4 groups. The bulk-fill RCs were applied in 4 mm thickness, whereas the conventional RC was applied in 2 mm thickness. In order to evaluate micro-leakage, class I cavities ($5{\times}2{\times}4mm$) were prepared in 32 permanent molars. The teeth were divided into 4 groups and restored with resin composites in an increment of 4 mm for the bulk-fill RC and in 2 horizontal increments of 2 mm for the conventional RC. The mean SBS value of conventional RC showed no statistically significant difference when compared with those of low-viscosity bulk-fill RCs. However, the mean SBS value of high-viscosity bulk-fill RC was significantly lower than that of conventional RC (p < 0.05). There were no statistically significant differences in micro-leakage between the 4 groups. For SBS and micro-leakage, the use of low-viscosity bulk-fill RCs might help clinicians simplify the procedure.

Bulk-fill 복합레진, 믿고 사용해도 될까?

  • Koh, Kyeol;Park, Jeong-Won
    • The Journal of the Korean dental association
    • /
    • v.57 no.3
    • /
    • pp.162-168
    • /
    • 2019
  • Composite resin restorations in posterior teeth are increasing due to the aesthetic needs of patients and the development of materials. This trend will accelerate in line with domestic insurance policies. However, resin composites generate stresses due to their contraction during the polymerization process. To reduce the polymerization shrinkage stress of resin composites, incremental layering technique has been recommended for decades. This technique reduces stress at the cavity wall interface and allows a more efficient light curing of the material. Bulk-fill resin composites have been designed to simplify the restorative technique because they can be placed into cavities in a single increment of 4-5mm. The simplification of the operative procedures is desirable in clinical daily practice. In this context, bulk-fill resin composites are an attractive alternative for posterior restorations. However, a clearer understanding of the clinical performance of this relatively new class of materials in comparison to conventional resin composites is required. Based on previous studies, the aim of the current review was to present the clinical criteria for the use of bulk-fill composites in direct restorations of posterior teeth.

  • PDF

Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks

  • Koc-Vural, Uzay;Baltacioglu, Ismail;Altinci, Pinar
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.118-124
    • /
    • 2017
  • Objectives: This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods: Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between $5-55^{\circ}C$, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex ($Colt\grave{e}ne/Whaledent$), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at $37^{\circ}C$. The color differences (${\Delta}E$) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (${\alpha}=0.05$). Results: Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions: Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.

Comparison of mechanical properties of a new fiber reinforced composite and bulk filling composites

  • Abouelleil, Hazem;Pradelle, Nelly;Villat, Cyril;Attik, Nina;Colon, Pierre;Grosgogeat, Brigitte
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.4
    • /
    • pp.262-269
    • /
    • 2015
  • Objectives: The aim of this study was to evaluate the mechanical and physical properties of a newly developed fiber reinforced dental composite. Materials and Methods: Fiber reinforced composite EverX Posterior (EXP, GC EUROPE), and other commercially available bulk fill composites, including Filtek Bulk Fill (FB, 3M ESPE), SonicFill (SF, Kerr Corp.), SureFil (SDR, Dentsply), Venus Bulk Fill (VB, HerausKultzer), Tetric evoceram bulk fill (TECB, Ivoclar Vivadent), and Xtra Base (XB, Voco) were characterized. Composite samples light-cured with a LED device were evaluated in terms of flexural strength, flexural modulus (ISO 4049, n = 6), fracture toughness (n = 6), and Vickers hardness (0, 2, and 4 mm in depth at 24 hr, n = 5). The EXP samples and the fracture surface were observed under a scanning electron microscopy. Data were statistically analyzed using one-way ANOVA and unpaired t-test. Results: EXP, FB, and VB had significantly higher fracture toughness value compared to all the other bulk composite types. SF, EXP, and XB were not statistically different, and had significantly higher flexural strength values compared to other tested composite materials. EXP had the highest flexural modulus, VB had the lowest values. Vickers hardness values revealed SF, EXP, TECB, and XB were not statistically different, and had significantly higher values compared to other tested composite materials. SEM observations show well dispersed fibers working as a reinforcing phase. Conclusions: The addition of fibers to methacrylate-based matrix results in composites with either comparable or superior mechanical properties compared to the other bulk fill materials tested.

Comparison of Mechanical Properties between Bulk-fill and Conventional Composite Resin (Bulk-fill과 Conventional 복합레진의 물성비교)

  • Seok, Ujeong;Kim, Jongbin;Kim, Kiseob;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.427-434
    • /
    • 2016
  • The aim of this study was to compare the mechanical properties of high viscosity bulk-fill resin composites, $Filtek^{TM}$ Bulk Fill Posterior Restorative (FBF) and $Tetric^{(R)}$ N-Ceram Bulk Fill (TBF), with conventional composite ($Filtek^{TM}$ Z-350 XT, Z-350). The Vickers hardness test which indicates the degree of conversion was performed and the dye penetration test was performed to measure the microleakage which indicates polymerization shrinkage amount. To minimize experimental error, the standardized 3D-printed molds and the bovine teeth were used. Obtained data were analyzed by the Kruskal-Wallis test and Mann-Whitney test with the confidence interval of 95%. In the microhardness test within 1 hour of polymerization, lower surface of FBF and TBF showed significantly lower value than that of Z-350 (p < 0.05). But after 24 hours, the microhardness of FBF had increased and showed no significant difference with Z-350 (p > 0.05). In top and 2 mm depth surface, mean microhardness values were in the following order: Z-350 > FBF > TBF (p < 0.05). The mean microleakage value of TBF was significantly lower than others (p < 0.05). For clinical application of bulk-fill resin composites, caution for applying masticatory forces during 24 hours after polymerization is advised and further studies to decrease microleakage should be conducted.