• 제목/요약/키워드: Bulk storage

검색결과 186건 처리시간 0.028초

미곡(米穀)의 산물유통(散物流通)을 위한 모델시스템 연구(硏究) (Study on the Model Systems for the Rice Post-Harvest Bulk System)

  • 장동일
    • Journal of Biosystems Engineering
    • /
    • 제12권2호
    • /
    • pp.44-59
    • /
    • 1987
  • The objectives of this study were to analyze and develop the model systems of rice post-harvest systems from drying to processing, and to develop a bulk system among them which requires minimum system cost and less operating time. The significance of this study was the development of a computer program (PPSARR). The PPSARR makes it possible to evaluate quantitatively the performance and economics of the rice post-harvest systems. The results show that the rice post-harvest bulk system requires less time and cost such as 37-60% and 46-59% of those of the sack system, respectively. Also, the former requires less manpower than the latter. For not more than 1,800 ton of rough rice production, the bulk system which is "drying & storage by IBDS-transport-milling" is recommended, and for more than 1,800 ton, the one which is "drying & storage by IBDS - transport - storing at flat storage improved - transport - processing by RPC" is recommended.

  • PDF

저온저장고 내부의 균일한 온도분포를 위한 3차원 공기유동 분석 (3-D Simulation of Air Flow in Cold Storage Room for Uniform Temperature Distribution)

  • 성제중;고학균;조성인;양길모
    • Journal of Biosystems Engineering
    • /
    • 제25권4호
    • /
    • pp.279-286
    • /
    • 2000
  • Most of the domestic cold storage rooms are inefficient for agricultural products because of temperature gradients inside the storage rooms. Temperature gradients are developed mainly by improper airflow pattern inside the storage room, which is a main cause of the spoilage of the agricultural products. There proper airflow pattern is essential to minimize these temperature gradients and the spoilage. The performance and characteristics of a cold storage room were determined as a function of airflow pattern and temperature distribution in forced circulation cold storage room. A commercial CFD(computational fluid dynamics) code was used to simulate 3-D airflow in the cold storage room. Solving the flow equations for the storage room, a standard k-$\varepsilon$ turbulent model was implemented to calculate steady state turbulent velocity distribution. The CFD prediction results were compared with temperature measurements inside the cold storage room. In case of pallet storage, Temperature gradients inside pallet storage was reduced because the contact area of cold air expanded through an alley of airflow in storage. But is case of bulk storage, the last temperature of storage considerably rose more than the initial temperature of storage. The reason was that bulk storage didn't include any alley of airflow in storage.

  • PDF

사암의 입자 체적계수 측정 방법에 대한 실험적 연구 (An Experimental Study on Measurement Method for Grain Bulk Modulus of Sandstone)

  • 김민준;박의섭;박찬;최준형
    • 터널과지하공간
    • /
    • 제33권2호
    • /
    • pp.71-82
    • /
    • 2023
  • 본 연구에서는 암반 수리-역학적 관계의 기본모델 입력인자인 암석 입자 체적계수에 대하여 직접적인 측정 실험법을 제시하고, 실험을 수행함으로써 암석 입자 체적계수를 도출하였다. 또한, 서로 다른 기하학적 특성을 가진 암석에 대하여 암석 입자 체적계수를 비교함으로써 입자 체적계수에 영향을 미치는 요인에 대해 살펴보았다. 실험 결과 이론적으로 추정하는 암석 입자 체적계수의 값이 실제보다 과대예측 하고 있음을 확인하였으며, 이에 대해 암체 입자 구조에 따른 암석 내부 고립돼있는 공극의 존재로 인한 가능성을 고찰하였다. 최종적으로, 본 연구에서 제시한 직접적인 측정방법이 사암의 입자 체적계수를 신뢰성 있게 예측할 수 있음을 확인하였다.

Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks

  • Koc-Vural, Uzay;Baltacioglu, Ismail;Altinci, Pinar
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.118-124
    • /
    • 2017
  • Objectives: This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods: Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between $5-55^{\circ}C$, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex ($Colt\grave{e}ne/Whaledent$), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at $37^{\circ}C$. The color differences (${\Delta}E$) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (${\alpha}=0.05$). Results: Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions: Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.

Prediction of Air Movement and Temperature Distribution at Different Store Methods Using 3-D CFD Simulation in Forced-Air Cooling Facility

  • Yang, G.M.;Koh, H.K.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.65-72
    • /
    • 2002
  • Temperature is the most influential environment parameter which affects the quality change of agricultural products in cold storage. Therefore, it is essential to keep the uniform temperature distribution in the storage room. This study was performed to analyze the air movement and temperature distribution in the forced recirculating cold storage facility and to simulate optimum storage method of green groceries using 3-D CFD(three dimensional computational fluid dynamics) computer simulation which applied the standard $textsc{k}$-$\varepsilon$ turbulence model and FVM(finite volume method). The simulation was validated by the experimental results for onion storage and the simulation model was used to simulate the temperature and velocity distribution in the storage room with reference to the change of storage method such as location of storage, no stores, bulk storage, and pallet storage. In case of no stores, internal airflow was circulated without stagnation and consequently air movement and temperature distribution were uniform. In case of bulk storage, air movement was stagnated so much and temperature distribution of onion was not uniform. Furthermore, the inner temperature of onion roses more than the initial temperature of storage. In case of pallet storage, air movement and temperature distribution of onion were so uniform that the danger of quality change was decreased.

  • PDF

The polymerization efficiency of a bulk-fill composite based on matrix-modification technology

  • Elshazly, Tarek M.;Bourauel, Christoph;Aboushelib, Moustafa N.;Sherief, Dalia I.;El-Korashy, Dalia I.
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.32.1-32.12
    • /
    • 2020
  • Objectives: To evaluate the polymerization efficiency of a matrix-modified bulk-fill composite, and compare it to a conventional composite which has a similar filler system. The degree of conversion (DC%) and monomer elution were measured over different storage periods. Additionally, fillers' content was examined. Materials and Methods: Cylindrical specimens were prepared, in bulk and incrementally, from Filtek Bulk Fill (B) and Filtek Supreme XTE (S) composites using a Teflon mold, for each test (n = 6). Using attenuated total reflection method of Fourier transformation infrared spectroscopy, DC% was measured after 24 hours, 7 days, and 30 days. Using high-performance liquid chromatography, elution of hydroxyethyl methacrylate, triethylene glycol dimethacrylate, urethane dimethacrylate, and bisphenol-A glycidyl dimethacrylate was measured after 24 hours, 7 days and 30 days. Filler content was examined by scanning electron microscopy (SEM). Data were analyzed using 2-way mixed-model analysis of variance (α = 0.05). Results: There was no significant difference in DC% over different storage periods between B-bulk and S-incremental. Higher monomer elution was detected significantly from S than B. The elution quantity and rate varied significantly over storage periods and between different monomers. SEM images showed differences in fillers' sizes and agglomeration between both materials. Conclusions: Matrix-modified bulk-fill composites could be packed and cured in bulk with polymerization efficiency similar to conventional composites.

톤백 및 와이어철제파렛트 이용에 따른 양파의 수확후관리 효율성 증대와 경제성 평가 (Beneficial effects of ton-bag and wire-steel pallet on postharvest handling of onion and the cost evaluation)

  • 권영득
    • 한국식품저장유통학회지
    • /
    • 제24권7호
    • /
    • pp.915-922
    • /
    • 2017
  • 양파의 관행 수확과 저장 방식을 개선하여 벌크 상태로 수확하여 수송, 하역, 보관 및 저장할 수 있도록 톤백 및 와이어철제파렛트를 개발한 후 관행저장 방식과 벌크저장 후 저장성을 비교하고 그에 따른 노동투입시간 및 소요비용을 비교하여 양파의 산지물류비 절감 효과를 비교 분석하고자 하였다. 본 연구를 통해 개발된 톤백이 관행 톤백보다 길이방향 인장강도가 16% 높았으며, 개발한 와이어철제파렛트가 관행철제파렛트보다 약 10% 더 저장가능하고 차량 적재 효율도 2배 이상 향상되었다. 개발된 500 kg용 와이어 철제파렛트의 벌크저장과 관행 그물망 저장의 감모율에는 차이가 없었으나, 1,000 kg 이상 많은 양을 저장할 경우 와이어철제파렛트 벌크저장은 관행저장보다 감모율이 3.7% 높아 적합하지 않는 것으로 나타났다. 톤백을 이용한 벌크 수확이 관행 망 수확보다 노동시간이 50.1% 그리고 총 투입비용은 46.1% 감소할 수 있는 것으로 나타났다. 와이어철제파렛트를 적용한 벌크저장이 관행저장보다 총 저장비용이 28.8% 감소하였으며, 2016년 양파생산량(1,298,749톤)의 30%를 와이어철제파렛트 벌크저장으로 대체할 경우 연간 183억 원을 절감할 것으로 추정된다. 따라서 현재 산지업체들의 와이어철제파렛트를 조기 도입하여 정착시키면 전국적으로 노동력 및 비용 절감에 상당한 효과가 있을 것으로 판단된다.

Electronic structure and magnetism of catalytic material Pt3Ni surfaces: Density-functional study

  • Sharma, Bharat Kumar;Kwon, Oryong;Odkhuu, Dorj;Hong, Soon Cheol
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2012년도 자성 및 자성재료 국제학술대회
    • /
    • pp.172-172
    • /
    • 2012
  • A Pt-skin $Pt_3Ni$(111) surface was reported to show high catalytic activity. In this study, we investigated the magnetic properties and electronic structures of the various oriented surfaces of bulk-terminated and Pt-segregated $Pt_3Ni$ by using a first-principles calculation method. The magnetic moments of Pt and Ni are appreciably enhanced at the bulk-terminated surfaces compared to the corresponding bulk values, whereas the magnetic moment of Pt on the Pt-segregated $Pt_3Ni$(111) surface is just slightly enhanced because of the reduced number of Ni neighboring atoms. Spin-decomposed density of states shows that the dz2 orbital plays a dominant role in determining the magnetic moments of Pt atoms in the different orientations. The lowering of the d-band center energy (-2.22 eV to -2.46 eV to -2.51 eV to -2.65 eV) in the sequence of bulk-terminated (100), (110), (111), and Pt-segregated (111) may explain the observed dependence of catalytic activity on surface orientation. Our d-band center calculation suggests that an observed enhanced catalytic activity of a $Pt_3Ni$(111) surface originates from the Pt-segregation.

  • PDF

투과형 홀로그램과 반사형 홀로그램에서의 Bragg detuning 현상에 대한 연구 (Study for the Bragg Detuning Effects on the Transmission Holograms and the Reflection Holograms)

  • 권윤영;김근율;박주연
    • 정보저장시스템학회논문집
    • /
    • 제2권3호
    • /
    • pp.189-195
    • /
    • 2006
  • Bragg detuning effect if, one of the serious problems if the photopolymer is used for the recording material of holography memories. And the critical reasons of that are known as the bulk refractive index change and shrinkage of recording material. However, the trials for analyzing the effect are mainly on the K-sphere and biased on the transmission hologram. So, we approached Bragg detuning effect numerically and applied the method to the transmission holograms and the reflection holograms all together. We simulated it with MATLAB. As a result, the bulk refractive index change causes+Bragg detuning effect on the transmission holograms and the reflection holograms. But the shrinkage leads to+Bragg detuning effect on the transmission hologram and-Bragg detuning effect on the reflective hologram. Compared to experimental result, the bulk refractive index change(${\fallingdotseq}4{\times}10^{-4}$) and the ratio of shrinkage to the thickness of the material(${\fallingdotseq}1.67{\times}10^{-3}$) could be matched with Bragg detuning effect on the transmission hologram and the reflection hologram.

  • PDF

Changes in Water Content Affect the Post-Milling Quality of Paddy Rice Stored at Low Temperature

  • Kim, Young-Keun;Hong, Seong-Gi;Lee, Sun-Ho;Park, Jong-Ryul;Choe, Jung-Seob
    • Journal of Biosystems Engineering
    • /
    • 제39권4호
    • /
    • pp.336-344
    • /
    • 2014
  • Purpose: In this study, the effect of milling on paddy rice stored at low temperature, the changes in grain temperature of bulk storage bags exposed at room temperature, the post-milling water content of paddy rice, the whiteness of rice, and the rate of pest incidence were investigated and data were analyzed. Methods: Changes in temperature inside the bulk storage bags kept at low temperature and grain temperature after exposure to room temperature were measured. Experiments were conducted for identifying the reasons of post-milling quality changes in paddy rice stored at low temperature. Results: It was determined that a short-term increase of water content in paddy rice was directly related to surface condensation, and that rice should be milled at least 72 h after removal from low-temperature storage, in order to completely eliminate surface condensation of paddy rice kept in bulk storage bags. It was observed that post-milling quality of rice changed, but water content was maintained at high levels for more than 18 d in rice that was milled when condensation occurred, regardless of paper or vinyl packaging. Rice whiteness rapidly decreased in rice that was milled when condensation occurred, regardless of packaging, while rice that was milled 72 h or more after removal from low temperature storage did not show any significant changes in whiteness. No pest incidence was observed up to 12 d after removal from low temperature storage, regardless of packaging. Starting at 18 d, after removal from low temperature storage, rice that was milled when condensation occurred, was affected by pests, while 24 d after removal from low temperature storage, all portions of rice were affected by pests. Conclusions: Our results suggest that changes in post-milling quality of rice could be significantly reduced by exposing paddy rice to room temperature for at least 72 h before milling, in order to allow the increase of grain temperature and prevent surface condensation.