• Title/Summary/Keyword: Bulb

Search Result 841, Processing Time 0.029 seconds

A Front-side Dry-Etched Thermopile Detector with 3-5 $\mu m$ Infrared Absorber and Its Application to Novel NDIR $CO_2$ Gas Sensors (3-5 $\mu m$ 적외선 흡수체를 가진 전면 건식 식각된 서모파일과 NDIR $CO_2$ 가스 센서의 응용)

  • Yoo, Kum-Pyo;Kim, Si-Dong;Choi, Woo-Seok;Singh, V.R.;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1470-1471
    • /
    • 2008
  • We present a front-side micromachined thermopile with high sensitivity in the 3-5${\mu}m$ window, and discuss its application to a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. The micromachined thermopile shows a measured sensitivity of 30 mV/W and a $D^*$ of $0.3{\times}10^8cm^{\surd}Hz/W$. Using this newly fabricated thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

A Case of Recurrent Liver Abscess Due to Choledochoduodenal Fistula (재발하는 간농양에서 총담관-십이지장 누공의 내시경적 치료 1예)

  • Hur, Jun Ho;Choi, Sun Taek;Sohn, Min Su;Lee, Ji Eun;Chung, In Hee;Ki, Sung Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.1
    • /
    • pp.39-42
    • /
    • 2013
  • Cholelithiasis, duodenal ulcer, duodenal perforation and tumor invasion may lead to choledochoduodenal fistula (CDF). CDF often has no specific symptoms and may be incidentally detected in an upper gastrointestinal radiographic study or endoscopy; but in some cases, it may be accompanied by recurrent cholangitis and liver abscess. In this paper, a case of recurrent liver abscess caused by CDF is reported. A 62-year-old female was admitted to the authors' hospital because of right upper quadrant pain and fever. The abdominal computed tomography showed a liver abscess in the right lobe. A duodenal fistulous orifice was detected with endoscopy, and a contrast was injected through the duodenal orifice using a catheter under fluoroscopy. The injection of the contrast revealed a fistulous track between the duodenal bulb and the common hepatic duct. In fistulas complicated by recurrent liver abscess, surgery or medical management may be needed. The CDF in this case study was treated via endoscopic clipping.

A Case of Duodenal Brunner's Gland Adenoma Treated by Endoscopic Rescetion (내시경으로 절제한 십이지장 Brunner선 선종 1예)

  • Kim, Sung-Joon;Gu, Min-Geun;Park, Jun-Suk;Kim, Kyeong-Ok;Lee, Si-Hyung;Kim, Tae-Nyeun;Choi, Jun-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.28 no.1
    • /
    • pp.84-89
    • /
    • 2011
  • Brunneroma, also known as Brunner's gland adenoma or harmatoma, is a very rare benign tumor of the duodenum, which is usually asymptomatic, and is discovered incidentally during endoscopic exam. These lesions are most commonly located in the duodenal bulb and clinical manifestations are variable. We report on a case of a large Brunner's gland adenoma in a 54-year-old man, which was successfully removed by endoscopic resection without complications, such as bleeding or perforation. Microscopically, it was composed entirely of variable Brunner's gland.

  • PDF

An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube (베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구)

  • Jun, Chul-Ho;Lee, Ho-Saeng;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

A study on Applicability through Comparison of Weather Data based on Micro-climate with existing Weather Data for Building Performative Design (건물 성능디자인을 위한 미기후 기반 기상데이터의 기존 기상데이터와 비교를 통한 활용 가능성 연구)

  • Kim, Eon-Yong;Jun, Han-Jong
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.101-108
    • /
    • 2011
  • The weather data has important role for performative building design. If the data location is close to building site, the result of performative design can be accurate. The data which have used nowadays in Korea are from U.S. Department of Energy (DOE) and Korea Solar Energy Society (KSES) but they cover only several locations in Korea which are 4 in DOE and 11 in KSES and there are opinions which it could be served building design efficiently even if the data are not enough. However the weather data for micro-climate are exist which are Green Building Studio Virtual Weather Station (GBS VWS) and Meteonorm weather data. Each weather data has different generation methods which are TMY2, TRY, MM5, and extrapolation. In this research, the weather date for climate are compared with DOE and KSES to check correlation. The result shows the value of correlation in Dry Bulb Temp. and Dew Point Temp. is around 0.9 so they have high correlation in both but in Wind Speed case the correlation(around 0.2) is not exist. In overall result, the data has correlation with DOE and KSES as the value of correlation 0.648 of GBS VW and 0.656 of Meteonorm. Even if the correlation value is not high enough, the patterns of difference in each weather element are similar in scatter plot.

A human case of Echinostoma hortense (Trematoda: Echinostomatidae) infection diagnosed by gastroduodenal endoscopy in Korea

  • Cho, Chang-Min;Tak, Won-Young;Kweon, Young-Oh;Kim, Sung-Kook;Choi, Yong-Hwan;Kong, Hyun-Hee;Chung, Dong-Il
    • Parasites, Hosts and Diseases
    • /
    • v.41 no.2
    • /
    • pp.117-120
    • /
    • 2003
  • A human Echinostoma hortense infection was diagnosed by gastroduodenoscopy. An 81-year-old Korean male, living in Yeongcheon-shi, Gyeongsangbuk-do and with epigastric discomfort of several days duration, was subjected to upper gastrointestinal endoscopy. He was in the habit of eating fresh water fish. Two live worms were found in the duodenal bulb area and were removed using an endoscopic forcep. Based on their morphological characteristics, the worms were identified as E. hortense. The patient was treated with praziquantel 10 mg/kg as a single dose. The source of the infection in this case remains unclear, but the fresh water fish consumed, including the loach, may have been the source. This is the second case of E. hortense infection diagnosed by endoscopy in Korea.

Analysis of Heat and Mass Transfer in an Evaporative Cooler with Fully Wetted Channel (채널이 수막으로 완전히 덮여 있는 증발식 냉각기에서의 열 및 물질전달 해석)

  • Song, Chan-Ho;Lee, Dae-Yeong;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1766-1775
    • /
    • 2001
  • A theoretical analysis on the heat and mass transfer in an evaporative cooler is presented in this work. The evaporative cooler is modeled as a channel filled with porous media the interstitial surface of which is covered by thin water film. Assuming that the Lewis number is unity and the water vapor saturation curve is linear, exact solutions to the energy and vapor concentration equations are obtained. Based on the exact solutions, the characteristics of the heat and mass transfer in the evaporative cooler are investigated. The comparison of the cooling performance between the evaporative cooler and the usual sensible heat exchanger is also carried out. Obviously, the evaporative heat exchanger shows better cooling performance than the sensible heat exchanger. This is due to the latent heat of water vaporization, which results in apparent increases both in the interstitial heat transfer coefficient and the specific heat of the air stream in the evaporative cooler.

An Experimental Study on the Effects of Afterbody Appendages and Hull Form on the Manoeuvrability of a Container Carrier (컨테이너 운반선의 조종성능에 미치는 선미 부가물과 선미형상의 효과에 관한 실험적 연구)

  • Ho-Young Lee;Deuk-Joon Yun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.3
    • /
    • pp.38-45
    • /
    • 1998
  • In this parer, the effects of a skeg, rudder and stern hull form on the manoeuvrability of a container carrier with small length to draft ratio have been investigated through a series of model test. Rudder open water tests and PMM tests were carried out with varying rudder area, afterbody appendages and stern hull form to investigate their effects on the manoeuvrability. The MMG model developed in Japan was used for the manoeuvring simulation with experimentally obtained hydrodynamic coefficients. The result showed that the effects by the variation of stern profile and the skeg below stern bulb are much larger than those by any other types of appendages in improving directional stability of the vessel.

  • PDF

Reverse Transcription Polymerase Chain Reaction-based System for Simultaneous Detection of Multiple Lily-infecting Viruses

  • Kwon, Ji Yeon;Ryu, Ki Hyun;Choi, Sun Hee
    • The Plant Pathology Journal
    • /
    • v.29 no.3
    • /
    • pp.338-343
    • /
    • 2013
  • A detection system based on a multiplex reverse transcription (RT) polymerase chain reaction (PCR) was developed to simultaneously identify multiple viruses in the lily plant. The most common viruses infecting lily plants are the cucumber mosaic virus (CMV), lily mottle virus (LMoV), lily symptomless virus (LSV). Leaf samples were collected at lily-cultivation facilities located in the Kangwon province of Korea and used to evaluate the detection system. Simplex and multiplex RT-PCR were performed using virus-specific primers to detect single- or mixed viral infections in lily plants. Our results demonstrate the selective detection of 3 different viruses (CMV, LMoV and LSV) by using specific primers as well as the potential of simultaneously detecting 2 or 3 different viruses in lily plants with mixed infections. Three sets of primers for each target virus, and one set of internal control primers were used to evaluate the detection system for efficiency, reliability, and reproducibility.

A Study of Hydrocarbon Reduction with Photocatalysts (광촉매를 이용한 탄화수소 저감 연구)

  • 손건석;고성혁;김대중;이귀영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.47-53
    • /
    • 2000
  • To overcome the shortage of conventional TWC that is activated at high temperature, higher than 25$0^{\circ}C$, photocatalyst is considered as an new technology. Because the photocatalytic reaction of photocatalyst is not a thermo mechanical reaction, it is necessary to heat the system to start the reaction. It can be activated just by ultra violet light that includes wavelengths shorter than 400 nanometers even at ambient temperature. In this study photocatalytic reduction of hydrocarbon was investigated with a model gas test. To understand the effects of co-existence gases on the hydrocarbon reduction by photoreaction, CO and NO, $O_2, H_2O$ gases those are components of exhaust gases of gasoline engine are supplied with C3H8/N2 to a photoreactor. The photoreactor contains $TiO_2$ photocatalyst powders and a UV bulb. The results show that oxygen is the most important factor to reduce HC emission with photocatalyst. Photocatalyst seems to have a good probability for automotive application to reduce cold start HC emissions.

  • PDF